• Title/Summary/Keyword: Flow-Field

Search Result 5,938, Processing Time 0.029 seconds

A Study on the Flow Analysis According to Impeller Speed for City Water Supply Measuring Valve (상수도용 계량 밸브 임펠러 회전수에 따른 유동해석에 관한 연구)

  • Tea-Joon Kim;Chung-Seob Yi;Chi-Woo Lee
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.2_2
    • /
    • pp.307-313
    • /
    • 2023
  • This study conducts the flow analysis on the basis of the impeller RPM of water metering valve. The software used for the flow analysis is STAR-CCM+. In terms of the structure of the metering valve, it has an impeller installed inside, and a metering chamber has inlet and outlet holes. The flow analysis on the water metering valve drew the following conclusions: Regarding the flow field in the valve, the impeller had the highest velocity distribution, and complex flow field was generated in the metering chamber. In particular, since the path between the inlet and outlet holes in the metering chamber and the valve body was narrow, there was a section that had flow field interference. The flow rate and flow coefficient distribution according to the impeller RPM were on the linear increase. Given that, it showed the feature of the valve used for water metering on the basis of the impeller RPM.

A Study on the Flow Analysis of Impeller type Measuring Valve according to Differential Pressure at Inlet and Outlet (임펠러 타입 계량 밸브 입·출구 차압에 따른 유동해석에 관한 연구)

  • Tea-Joon Kim;Chung-Seob Yi;Chi-Woo Lee
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.3
    • /
    • pp.381-387
    • /
    • 2023
  • This study conducts the flow analysis on the basis of the impeller RPM of water measuring valve and differential pressure at valve inlet and outlet. The software used for the flow analysis is STAR-CCM+. In terms of the structure of the measuring valve, it has an impeller installed inside, and a metering chamber has inlet and outlet holes. The flow analysis on the water measuring valve drew the following conclusions: The flow rate and flow coefficient distribution according to the impeller RPM and differential pressure were on the linear increase. Regarding the flow field in the valve, the increased differential pressure had the highest velocity distribution, and complex flow field was generated in the measuring chamber. In particular, since the path between the inlet and outlet holes in the measuring chamber and the valve body was narrow, there was a section that had flow field interference. Given that, it showed the feature of the valve used for water measuring on the basis of the impeller RPM.

Flow Field Analysis of a Centrifugal Fan (원심형 팬의 유동해석에 관한 연구)

  • Im, Jongsoo;Kim, Changseong;Shin, Dongshin;Rho, Ohyun;Lee, Soogab
    • 유체기계공업학회:학술대회논문집
    • /
    • 1998.12a
    • /
    • pp.105-114
    • /
    • 1998
  • Flow field and near-field noise of a centrifugal fan has been studied with an efrcient compressible method and STAR-CD. The flow field of the centrifugal fan is assumed two-dimensional. Most of the compressible studies has been done by inviscid solver because viscous simulation shows little difference. The near field noise is estimated in term s of sound pressure level in frequency domain transformed from the computed pressure fluctuations using FFT. The simulation has been done on various design elements such as impeller blade shapes, the number of blades and cut-off clearance. The comparison shows that the number of blades has a significant effect on near-field noise without losing aerodynamic performance.

  • PDF

Flow Field Analysis of a Centrifugal Fan (원심형 홴의 유동해석에 관한 연구)

  • Shin, Dong-Shin;Im, Jong-Soo;Kim, Chang-Seong;Rho, O-Hyun;Lee, Soo-Gab
    • The KSFM Journal of Fluid Machinery
    • /
    • v.2 no.1 s.2
    • /
    • pp.43-49
    • /
    • 1999
  • Flow field and near-field noise of a centrifugal fan has been studied with an efficient compressible method and STAR-CD. The flow field of the centrifugal fan is assumed to be two-dimensional. Most of the compressible studies have been done by inviscid solver because viscous simulation shows little difference. The near field noise is estimated in terms of sound pressure level in frequency domain transformed from the computed pressure fluctuations using FFT. The simulation has been done on various design elements such as impeller blade shapes, the number of blades and cut-off clearance. The comparison shows that the number of blades has a significant effect on near-field noise without losing aerodynamic performance.

  • PDF

An Analysis of the Flow and Sound Field of a Ducted Axial Fan (덕트가 있는 축류홴의 유동 및 음향장 해석)

  • Jeon, Wan Ho;Chung, Ki Hoon;Lee, Duck Joo
    • The KSFM Journal of Fluid Machinery
    • /
    • v.3 no.2 s.7
    • /
    • pp.15-23
    • /
    • 2000
  • The present work describes the prediction method for the unsteady flow field and the acoustic pressure field of a ducted axial fan. The prediction method is comprised of time-marching free-wake method, acoustic analogy, and the Kirchhoff-Helmholtz BEM. The predicted sound signal of a rotor is similar to the experiment one. We assume that the rotor rotates with a constant angular velocity and the flow field around the rotor is incompressible and inviscid. Then, a time-marching free-wake method is used to model the fan and to calculate the flow field. The force of each element on the blade is calculated by the unsteady Bernoulli equation. Lowson's method is used to predict the acoustic source. The newly developed Helmholtz-Kirchhoff BEM lot thin body is used to calculate tile sound field of the ducted fan. The ducted fan with 6 blades is analysed and the sound field around the duct is calculated.

  • PDF

FSI Analysis on a Floating Cylinder by 3D Flow-Structure Interaction (FSI) Measurement System (유동-구조상관(FSI) 3차원 측정시스템에 의한 부유식 실린더 연동운동해석)

  • Doh, D.H.;Sang, J.W.;Hwang, T.G.;Pyeon, Y.B.;Baek, T.S.
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1574-1579
    • /
    • 2004
  • A simultaneous measurement system that can analyze the flow-structure interactions(FSI) has been constructed and analyses on the flow field and the motion field of a floating cylinder was made. The three-dimensional vector fields around the cylinder are measured by 3D-PTV technique while the motion of the cylinder forced by the flow field is measured simultaneously with a newly developed motion tracking algorithm(bidirectional tracking algorithm). The cylinder is pendant in the working fluid of a water channel and the surface of the working fluid is forced sinusoidal to make the cylinder bounced. The interaction between the flow fields and the cylinder motion is examined quantitatively.

  • PDF

Unsteady Performance Analysis of Accelerating Compressor Cascade (가속되는 압축기 익렬의 비정상 성능해석)

  • Kim M.-H.;Choi J.-Y.;Kim K. S.;Lee G. S.;Kim Y. I.;Lim J. S.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2001.05a
    • /
    • pp.121-126
    • /
    • 2001
  • An accelerating flow field through a compressor cascade is studied numerically by unsteady computational simulation. The two-dimensional Navier-Stokes equations for compressible flow is used for the study of unsteady high incidence angle flow, with preconditioning scheme to cover the wide range of Mach number and $\kappa-\omega$ model for the turbulent viscous flow analysis. A DCA(double circular arc) compressor blade is accelerated artificially in this study to understand the unsteady effect by comparing the present results with the existing steady-state experimental and computational results. Also, the accelerating flow field during the starting phase of gas turbine is studied with actual experimental data for the understanding of flow field and performance characteristics at off-design condition.

  • PDF

Measurement of Flow Field through a Staggered Tube Bundle using Particle Image Velocimetry (PIV기법에 의한 엇갈린 관군 배열 내부의 유동장 측정)

  • 김경천;최득관;박재동
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.7
    • /
    • pp.595-601
    • /
    • 2001
  • We applied PIV method to obtain instantaneous and ensemble averaged velocity fields from the first row to the fifth row of a staggered tube bundle. The Reynolds number based on the tube diameter and the maximum velocity was set to be 4,000. Remarkably different natures are observed in the developing bundle flow. Such differences are depicted in the mean recirculating bubble length and the vorticity distributions. The jet-like flow seems to be a dominant feature after the second row and usually skew. However, the ensemble averaged fields show symmetric profiles and the flow characteristics between the third and fourth measuring planes are not so different. comparison between the PIV data and the RANS simulation yields severe disagreement in spite of the same Reynolds number. It can be explained that the distinct jet-like unsteady motions are not to be accounted in th steady numerical analysis.

  • PDF

Optimization of the Mixing Flow in an Agitated Tank

  • Yoo, Dal-Hyun;Yang, Si-Young;Choi, Youn-Kyu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.151-157
    • /
    • 2005
  • In the chemical, mineral and electronics industries, mechanically stirred tanks are widely used for complex liquid and particle mixing processes. In order to understand the complex phenomena that occur in such tanks, it is necessary to investigate flow field in the vessel. Most difficulty on the numerical analysis of stirred tank flow field focused particularly on free surface analysis. In order to decrease the dead zone and improve the flow efficiency of a system with free surface, this paper presents a new method that overcomes free surface effects by properly combining the benefits of using experiment and 3-D CFD. This method is applied to study the mixing flow in an agitated tank. From the results of experimental studies using the PIV (particle image velocimetry) system, the distribution of mixing flow including free surface are obtained. And these values that are expressed as a velocity vector field have been patched for simulating the free surface. The results of velocity distribution obtained by 3-D CFD are compared with those of experimental results. The experimental data and the simulation results are in good agreement.

  • PDF

Analysis of flow and heat transfer in internally finned tube (내부 핀이 부착된 열교환기의 유동장해석)

  • Jeong Ho-Eyoul;Jeong Jae-Tack;Ko Hyung-Jong
    • 한국전산유체공학회:학술대회논문집
    • /
    • 1999.11a
    • /
    • pp.139-144
    • /
    • 1999
  • There have been many studies for heat transfer enhancement. Particularly, the study of flow in heat exchangers which have fin device has been main theme in heat transfer area. Practically, the circular tube which has internal fins is widely used for developing heat transfer rate. In this study, flow and heat transfer analysis of the circular tube with fins are investigated. The height and the number of fins are arbitrary. The flow field is assumed to be laminar. The conformal mapping is used for analytic solution of the laminar flow field. Discretization of governing equation, namely, FDM was used for numerical analysis. The velocity field, flow rate and shear stress are calculated for some numbers of fins in circular tube and for some heights of fin. Temperature fields are plotted along the tube length. It can be shown that the numerical solution agrees with the analytical solution.

  • PDF