• Title/Summary/Keyword: Flow rate coolant

Search Result 241, Processing Time 0.03 seconds

냉매 과냉각을 이용한 열펌프 시스템의 성능 특성 (The Performance Characteristics of Heat Pump Using the Refrigerant Subcooling)

  • 노건상;손창효
    • 한국수소및신에너지학회논문집
    • /
    • 제18권4호
    • /
    • pp.413-421
    • /
    • 2007
  • In this paper, the performance characteristics of heat pump system using a new refrigerant subcooling system designed for the study, are introduced. The new heat pump system have the ice storage tank at the outlet of condenser. The experimental apparatus is a well-instrumented water/water heat pump which consisted of working fluid loop, coolant loop, and ice storage tank. The experiment parameters of subcooling ranged as the evaporating temperature from $-5^{\circ}C$ to $8^{\circ}C$, the condensing temperature from $30^{\circ}C$ to $35^{\circ}C$. The test of the ice storage was carried out at evaporating temperature of $-10^{\circ}C$ and the ice storage mode is Ice-On-Coil type. The working fluid was R-22 and the storage materials were city-water. The test results obtained were as follows; The refrigerant mass flow rate and compressor shaft power were unchanged by the degrees of subcooling, that is, they were independent of degrees of subcooling. The cooling capacity of the new heat pump system increase as the evaporating temperature and subcooling degrees increase and is higher by $25{\sim}30%$, compared to the normal heat pump system. The COP of the new heat pump system increases as the degrees of subcooling and evaporating temperature increase and is higher by 28% than that of the normal heat pump system.

온도에 따른 집광형 태양전지의 성능에 관한 실험적 연구 (An Experimental Study on the Performance of a Concentrating Photovoltaic Cell as a Function of Temperature)

  • 신재혁;이승신;김상민;부준홍
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.96-101
    • /
    • 2012
  • An experimental study was conducted to investigate the performance of a concentrating photovoltaic cell (CPV) against temperature. It is know that a high efficiency of a CPV can be achieved only with proper cell temperature as well as high concentration ratio (CR). This study is concerned with appropriate cooling condition for a liquid-convection cooler for the best performance of a specific CPV. A series of experiments was conducted in a range of cell temperatures as a result of varying cooling conditions, while the concentration ratio was 390 and the solar irradiation flux was higher than 900 $W/m^2$ in outdoor environment. The CPV had a planar dimension of 10 by 10 mm. A Fresnel lens was used as a concentrator, of which the dimension was 221 mm(W) ${\times}$ 221 mm(L) ${\times}$ 3 mm(t) and the transmissivity was known to be 0.8. The cooler was attached to the bottom side of the CPV and had a contact area of 21 mm(W) ${\times}$ 26 mm(L), which was identical to the size of the base plate of the CPV. The coolant temperature was controlled by an isothermal bath and the flow rate was controlled and measured by a flowmeter. The experimental results showed that the average of power efficiency of the CPV decreased from 28.6 % to 24.7 % as the cell temperature increased from $36^{\circ}C$ to $97^{\circ}C$. An appropriate cooling method of a CPV might increase the power conversion efficiency by about 4% for the same concentration ratio. Discussion is included from the viewpoint of the combined efficiency in addition to the power efficiency.

  • PDF

최적계산코드를 이용한 대형 냉각재상실사고시 유량조절기 성능평가에 관한 연구 (Computational Study for the Performance of Fludic Device during LBLOCA using TRAC-M)

  • 전우청;이재훈;이상종
    • 에너지공학
    • /
    • 제14권1호
    • /
    • pp.54-61
    • /
    • 2005
  • 한국형 신형원자로1400(APR1400)은 3983MWt급의 2×4 루프 개량형 가압경수로(PWR)로서 대형 냉각재상실사고 발생시 안전주입수의 원자로용기 직접주입(DVI) 방식을 채택하고 있으며, 안전주입수탱크(SIT) 내부에 유량조절기(Fluidic Device, FD)를 장착하고 있다. 본 연구에서는 신형원자로 1400의 안전주입계통에 새로이 적용된 주요 특징 중 하나인 유량조절기에 대하여 최적안전해석코드인 TRAC-M/F90, 3.782버전을 이용한 성능평가 및 민감도 분석을 수행하였다. 연구결과 유량조절기가 안전주입수의 원자로 유입을 적절하게 조절하고 있음을 확인하였으며, 안전주입수탱크 내부의 압축질소체적 감소가 안전 주입수체적 감소에 비하여 노심의 급냉 완료 시점을 빠르게 하였다. 또한 안전주입계통의 전체 저항계수(K factor)가 최소 또는 최대일 때 노심의 급냉 완료 시점은 평균값인 경우보다 다소 늦어졌으나, 피복재 최고온도(PCT)는 상대적으로 큰 차이가 발생하지 않았다.

엔진 폐열 회수를 위한 랭킨 스팀 사이클 설계 및 HT Boiler의 성능 평가 (Design of Rankine Steam Cycle and Performance Evaluation of HT Boiler for Engine Waste Heat Recovery)

  • 허형석;배석정;이동혁;이헌균;김태진
    • 한국자동차공학회논문집
    • /
    • 제20권2호
    • /
    • pp.21-29
    • /
    • 2012
  • A dual loop waste heat recovery system with Rankine steam cycles for the improvement of fuel efficiency of gasoline vehicles has been investigated. A high temperature loop (HT loop) only recovers the heat of the exhaust gas. A low temperature loop (LT loop) recovers the residual heat from the HT loop, the coolant heat and the remaining exhaust gas heat. The two separate loops are coupled with a heat exchanger. This paper has dealt with a layout of the dual loop system, the review of the working fluids, and the design of the cycle. The design point and the target heat recovery of the HT boiler, a core part of a HT loop, have been presented. The prototype of the HT boiler was evaluated by experiment. For the performance evaluation of the HT boiler, inlet temperature of the HT boiler working fluid was set equal to the temperature degree of sub-cool of $5^{\circ}C$ at the condensing pressure. The exit condition was the degree of super-heat set at $5^{\circ}C$. The characteristics of the HT boiler such as heat recovery and pressure drops of fluids were evaluated with varying flow rates and inlet temperatures of exhaust gas under various evaporating pressure conditions.

냉매 과냉각 시스템을 이용한 열펌프의 성능향상에 관한 연구 (Performance Enhancement of the Heat Pump Using the Refrigerant Subcooling System)

  • 손창효;윤찬일;박승준;이동건;오후규
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2001년도 춘계학술대회 논문집
    • /
    • pp.106-111
    • /
    • 2001
  • The performance characteristics of heat pump system using the new refrigerant subcooling system were investigated. The new heat pump system has the ice storage tank to accumulate the latent heat of the refrigerant during the night-time. The heat is released to subcool the saturated refrigerant liquid at the outlet of a condenser in the daytime. The experimental apparatus is a well-instrumented heat pump which consisted of a refrigerant loop and a coolant loop. The test sections(condenser and evaporator) were made of tube-in-tube heat exchanger with the horizontal copper tube of 12.7[mm] outer diameter and 9.5[mm] inner diameter. The evaporating temperatures ranged from $-5[^{\circ}C]$ to $0[^{\circ}C]$ and the subcooling degrees of the refrigerant varied from $15[^{\circ}C]$ to $25[^{\circ}C]$. The test of the ice storage was carried out at evaporating temperature of $-10[^{\circ}C]$ and the ice storage mode is an ice-on-coil type. The main results were summarized as follows ; The refrigerant mass flow rate and compressor shaft power of the heat pump system were independent of the subcooling degrees. The cooling capacity o the heat pump system increases as the evaporating temperature and subcooling degree increases. The cooling capacity of the heat pump system is about 25 to 30% higher than that of normal heat pump system. The COP of the heat pump system which subcooled the refrigerant liquid at the outlet of the condenser is about 28% higher than that of the normal heat pump system.

  • PDF

가압경수로의 운전변수 변화에 대한 DNBR의 민감도 (DNBR Sensitivities to Variations in PWR Operating Parameters)

  • Hyun Koon Kim;Ki In Han
    • Nuclear Engineering and Technology
    • /
    • 제15권4호
    • /
    • pp.236-247
    • /
    • 1983
  • 한국원자력 1호기(KNU-1)의 설계 및 운전자료를 이용하여 가압경수로 운전변수들의 변화에 대한 DNBR의 민감도를 분석하였다. 본 민감도 분석에는 원자로 출력, 압력, 냉각수 주입유량, 냉각수 주입온도, 반경방향 및 축방향 출력분포 그리고 축방향 출력편차 등의 운전변수가 고려되었다. 민감도 분석을 위하여는 노심의 열수력 해석용 전산코드인 COBRA-IV-K를 사용하였는데 본 코드는 COBRA-IV-i의 수정판으로써 한국에너지연구소에서 일부 프로그램을 수정하였고 또한 신뢰도도 확인하였다. 민감도 분석을 수행하기 전에 KNU-1 원자로심의 설계 및 운전조건을 근거로 하여 기초 계산을 수행하고 이 결과를 본 민감도 분석의 기본자료로 삼았다. 민감도 분석결과 원자로의 DNBR 열설계에 있어서 가장 민감한 운전변수는 냉각수 주입온도이고 가장 둔감한 변수는 축방향 출력분포라는 것이 밝혀졌다.

  • PDF

SMART-ITL 1 계열 피동안전계통을 이용한 안전주입배관 파단 소형냉각재상실사고 모의에 대한 실험적 연구 (Experimental Study of SBLOCA Simulation of Safety-Injection Line Break with Single Train Passive Safety System of SMART-ITL)

  • 류성욱;배황;유효봉;변선준;김우식;신용철;이성재;박현식
    • 대한기계학회논문집B
    • /
    • 제40권3호
    • /
    • pp.165-172
    • /
    • 2016
  • 노심보충탱크(Core Makeup Tank, CMT), 안전주입탱크(SafetyInjection Tank, SIT)와 자동감압계통(Auto Depressurization System, ADS)로 구성된 1 계열의 SMART 피동안전주입계통의 주입특성을 파악하기 위한 소형냉각재상실사고(SBLOCA) 모의에 대한 실험적 연구가 수행되었다. SBLOCA의시험은 0.4 인치 안전주입수 배관파단에 대해 수행되었으며, 정상상태 조건은 실험요건서에 제시된 시험 초기 조건을 만족시키도록 746초 동안 운전되었다. 노심 출력 및 안전주입 유량 등의 경계 조건도 적절히 모의되었으며, 안전주입계통 배관에서의 파단, 히터 트립 및 잔열곡선 인가, 원자로냉각재펌프 관성서행(Coastdown), 급수 중단, CMT 및 SIT의 주입, ADS #1 개방이 SBLOCA 시나리오에 따라 적절히 모의되었다. 노심지지원통 내부의 액체환산수위는 파단 초반에 감소하다가 CMT와 SIT가 주입되면서 서서히 회복되었으며, 피동안전주입계통의 주입유량이 노심 수위를 회복하기에 충분한 것으로 판단할 수 있다.

고리 1호기에 대한 증기배관 파열사고 연구 (Study on the Steam Line Break Accident for Kori Unit-1)

  • Tae Woon Kim;Jung In Choi;Un Chul Lee;Ki In Han
    • Nuclear Engineering and Technology
    • /
    • 제14권4호
    • /
    • pp.186-195
    • /
    • 1982
  • SYSRAN code를 사용하여 고리 1호기의 중기배관파열사고를 분석하였다. SYSRAN code는 중성자출력과 열선속계산은 각각 점근사 중성자 운동방정식과 집중정수 모형을 이용하고 냉각수 계통 과도현상에 대해서는 전 계통을 균일한 압력으로 취급하여 질량 및 에너지 평형방정식을 이용하여 계산한다. 사고 결과를 심각하게 만드는 노심상태로 부냉각재 온도계수가 커지는 노심말기와 증기발생기의 유체함량이 가장 많은 고온 정지상태를 호기조건으로 하여, 격납용기외부의 가장 큰 배관면적인 1.4f $t^2$ 크기의 증기배관이 파열되었을때 Moody critical flow model에 따라 증기가 방출된다고 가정하여 분석하였다. 그 결과 노심의 최대 열선속은 사고후 60초에 정상상대의 38%로서 FSAR의 26%에 비해 높은 값을 나타냈으나 모든 과도현상의 경향은 FSAR의 결과와 잘 일치하였다. 민감도 조사결과 이 사고는 냉각재밀도 계수와 노심 하부공간혼합인자에 가장 민감한 것으로 나타났다. B bank중 한 개의 RCCA가 완전인출 상태에서 노심에 삽입되지 않았다고 가정했을 경우의 FSAR 분석결과인 $F_{$\Delta$H}$를 3.66으로 Fz를 1.55로 하여 DNBR을 계산해 본 결과, 최소 DNBR은 1.62가 되어 핵연료의 손상은 예상되지 않았다. 점근사중성자 운동방정식, 집중 정수모형 및 질량과 에너지평형 방정식을 이용한 계통 과도 현상모델은 발전소 전 계통의 과도 현상의 경향을 연구하는데 적합한 것으로 밝혀졌다.구하는데 적합한 것으로 밝혀졌다.

  • PDF

터보 냉동기용 핀튜브에 관한 연구 ( I ) - 응축 열전달에 관하여 - (A Study on Finned Tube Used in Turbo Refrigerator( I ) -for Condensation Hear Transfer-)

  • 조동현;한규일;김시영
    • 수산해양교육연구
    • /
    • 제5권1호
    • /
    • pp.31-44
    • /
    • 1993
  • Through the early 1900's, the evolution of the surface condenser was closely tied to the development of steam engine and the turbine. As the chemical and petroleum industries evolved in the 1900's, the use of surface condensers in many different processes. Today, industry uses condensers in many shapes and sizes. The actual condensation process occurs on the outside surface of tubes. The nature of this surface geometry affects the condenser's heat transfer performance. The first condensers were built with plain tubes. As tube manufacturing techniques advanced, manufacturers started making tubes with integral fins. In the 1940's, fin densities were limited to about 600 to 700 fins per meter(fpm) because of manufacturing procedure. Today new manufacturing techniques allow production of tubes with fin densities ranging from 750 to 1600 fpm. The integral-fin tubes investigated in this paper are nominally 19 mm diameter. Eight tubes have been used with trapezodially shaped integral-fins having fin density from 748 to 1654 fpm and 10, 30 grooves. For comparison, tests are made using a plain tube having the same inside diameter and an outside diameter equal to that at the root of the fins for the finned tubes. Betty and Katz's theoretical modelis is used to predict the R-11 condensation coefficient on horizontal integral-fin tubes having 748, 1024 and 1299 fpm. Experiments are carried out using R-11 as working fluid. The refrigerant condensates at a saturation state of $30^{\circ}C$ on the outside tube surface cooled by coolant. The amount of noncondensable gases present in the test loop is reduced to a negligible value by repeated purging. For a given heat input to the boiler and given cooling water flow rate, all test data are taken at steady state. The observed heat transfer enhancement for the finned and grooved tubes significantly exceeded that to be expected on grounds of increased area. For the eight fin tubes and one plain tube tested, the best performance has been obtained with a tube having a fin density of 1299 fpm, and a fin bight of 1.2mm and 30 grooves.

  • PDF

실리콘의 염소화반응에 의한 사염화규소 제조 (Preparation of Silicon Tetrachloride by Chlorination of Silicon)

  • 박균영;이미선;김민철;이찬희;박회경;강태원;정해성;한경아;허원회;유지철
    • Korean Chemical Engineering Research
    • /
    • 제51권3호
    • /
    • pp.407-410
    • /
    • 2013
  • 직경 25 mm의 파이렉스 튜브 내에서 실리콘의 유동층 염소화 반응이 수행되었다. 반응기에 공급되는 질소 유량 0.8~1.0 L/min, 염소 유량 0.2 L/min, 반응온도 $450^{\circ}C$, $SiCl_4$ 응축기의 냉매온도는 $-5^{\circ}C$로 설정하였다. 반응기에 도입되는 가스 내 염소의 몰분율이 증가하면 $SiCl_4$의 수율이 증가하였다. 반응가스 중 염소의 몰분율 0.2의 조건에서 $SiCl_4$의 수율은 28% 이었다. 염소의 몰분율 증가는 반응열 상승에 의해 반응온도 상승을 가져옴으로써 안전을 고려하여 염소의 몰분율을 0.2 이상으로 올리지 못했다. 실리콘의 유동층 염소화 반응에 의한 사염화실리콘의 제조 가능성이 입증되었으며, 향후 보다 가혹한 조건에서의 실용화 연구를 위한 기초로 활용될 수 있을 것으로 기대된다.