• 제목/요약/키워드: Flow rate characteristics

검색결과 3,553건 처리시간 0.033초

터빈형과 기어모터형 유량계의 동특성 검토 (An Investigationi into the Dynamic Characteristics of Turbine and Gear Motor Type Flowmeters)

  • 예용택
    • 한국생산제조학회지
    • /
    • 제9권3호
    • /
    • pp.83-89
    • /
    • 2000
  • In hydraulic control system turbine and gear motor type flowmeters are widely used to measure the flow rate under steady flow conditions. With the recent growth of interest in the measurement of instantaneous values of unsteady flow rate the test of the transient response of these flowmeters are in some significance. however an unsteady flow rate mea-surment and its calibration method with a fast response and a high accuracy have not beendeveloped. In this research particularly the dynamic characteristics of turbine and gear motor type flowmeters are investigated experimentally and simple mathematical models are proposed. The measured flow rate waveforms are compared with those by remote instan-taneous flow rate measurement method(RIFM) which has been developed by author and used for calibration As the result of frequency response test gain and phase between the measured flow rate waveforms by turbine type flowmeter and those estimated by RIFM are in good agreement up to 70Hz For the gear motor type flowmeter th simulated results by a math-ematical model proposed here agree well with the experiment nearly up to 100Hz. Also it if sound that the pressure drop across the flowmeter is increased in proportion to the frequency of the flow rate variation in a high frequency region of more than 100Hz. It can be explained that the dealy of gear motor type flowmeter in high frequency regionis mainly attributed to a first order delay consisting of the inertia of gears and internal leakage of the gear motor.

  • PDF

용접식 판형열교환기에서 작동유체의 유량과 온도변화에 따른 성능특성 고찰 (Investigation of Performance Characteristics in a Welded Plate Heat Exchanger according to Mass flow rate and Temperature)

  • 함정균;김민준;안성국;조홍현
    • 한국지열·수열에너지학회논문집
    • /
    • 제14권4호
    • /
    • pp.20-26
    • /
    • 2018
  • In this study, the performance characteristics of a welded plate heat exchanger was investigated experimentally. Performance tests were carried out according to the flow rate and inlet temperature of working fluid. As a result, the heat transfer capacity increased by 335.5 kW with an increasing the flow rate and temperature difference between hot and cold side. However, the overall heat transfer coefficient was increased with the increase of flow rate, and it was not effected significantly from inlet temperature difference between hot and cold working fluid. The pressure drop was increased by 55.78 kPa with an increasing the frow rate when the flow rate ratio between hot and cold side 1:1. However, the tendency of pressure drop was difference when flow rate ratio wasn't 1:1. In case that the flow rate ratio between hot and cold side was not 1:1, the pressure drop at the low flow rate side was higher than that when the flow rate ratio was 1:1, while pressure drop of the other side was decreased compared to that when the flow rate ratio was 1:1.

진동장에서의 비뉴턴유체 유동의 특성 (Characteristic of the non-Newtonian fluid flows with vibration)

  • 최성호;신세현
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.2048-2053
    • /
    • 2003
  • The present study investigated the effect of the transversal vibration on the flow characteristics for non-Newtonian fluids. The effect was tested by experiment and numerical analysis. For Newtonian fluids, both of experiment and numerical analysis results showed that mechanical vibration did not affect the flow rate. For non-Newtonian fluids, however, there was significant disagreement between experiment and numerical results. The numerical results showed a negligibly small effect of vibration on the flow rate whereas experimental results showed a significant flow rate increase associated with transversal vibration. The results implied that the increased flow rate was caused not only by imposed shear rates at the wall but also by the changes of rheological characteristics due to the transversal vibration.

  • PDF

Comparison of Shear-Thinning Blood Flow Characteristics between Longitudinal and Transverse Vibration

  • Choi, Sung-Ho;Shin, Se-Hyun;Lee, Kyung-Tae
    • Journal of Mechanical Science and Technology
    • /
    • 제18권12호
    • /
    • pp.2258-2264
    • /
    • 2004
  • This article described the numerical investigation of shear-thinning blood flow characteristics when subjected to longitudinal and transverse vibrations and delineated the underlying mechanisms of the flow rate enhancements, respectively. In order to fully consider the mechanical vibrations of the capillary, a moving wall boundary condition was adopted. The present numerical results showed that the longitudinal vibration caused a significant increase of wall shear rates, which resulted in a decrease of viscosity and the subsequent increase of flow rates. However, the shear rate for the transverse vibration was slightly increased and the calculated flow rate was underestimated comparing with the previous experimental results.

Effect of Mixture Flow Rate on Emission Characteristics of Laminar Premixed CH4/Air Flame with Changing Combustor Pressure

  • Ma, Hai-quan;Song, Jae-hyeok;Kang, Ki-joong;Choi, Gyung-min;Kim, Duck-jool
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2012년도 제44회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.269-271
    • /
    • 2012
  • To investigate emission characteristics of laminar premixed CH4/air flame, combustion experiments were conducted at three flow rates (5.3L/min, 10.6L/min, 15.5L/min) with changing the combustor pressure(-30Kpa-30Kpa). It was found that with increasing flow rate, NOx emission increased in high pressure condition, while decreased in low pressure condition; and the emission of CO decreased with increasing flow rate. For the influence of pressure, emission of NOx increased with increasing pressure regardless of flow rates, while CO emission decreased on the contrary.

  • PDF

Dynamic Characteristics of a Urea SCR System for NOx Reduction in Diesel Engine

  • Nam, Jeong-Gil;Choi, Jae-Sung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제31권3호
    • /
    • pp.235-242
    • /
    • 2007
  • This paper discusses dynamic characteristics of a urea-SCR (Selective Catalytic Reduction) system. The urea flow rate to improve NOx conversion efficiency is generally determined by parameters such as catalyst temperature and space velocity. The urea-SCR system was tested in the various engine operating conditions governing the raw NOx emission levels, space velocity. and SCR catalyst temperature. These experiments include cold-transients to determine catalyst light-off temperature and urea flow rate transients. Likewise. ammonia storage dynamics was also investigated. The cold-transient results indicate the light-off temperature of the catalysts used in these experiments was $200-220^{\circ}C$. The ammonia storage and urea flow rate transients all indicate very slow dynamics (on the order of seconds) which presents control challenges for mobile applications. The results presented in this paper should provide an excellent starting point in developing a functional in-vehicle urea-SCR system.

DC Magnetron Sputtering에 의한 ATO 박막의 제조 (I)증착특성 (Preparation of ATO Thin Films by DC Magnetron Sputtering (I) Deposition Characteristics)

  • 윤천;이혜용;정윤중
    • 한국세라믹학회지
    • /
    • 제33권4호
    • /
    • pp.441-447
    • /
    • 1996
  • Sb doped SnO2(ATO:Antinomy doped Tin Oxide) thin films were prepared by a DC magnetron spttuering method using oxide target and the deposition characteristics were investigated. The experimental conditions are as follows :Ar flow rate : 100 sccm oxygen flow rates ; 0-100 sccm deposition temperature ; 250 -40$0^{\circ}C$ DC sputter powder ; 150~550 W and sputtering pressure ; ; 2~7 mTorr. Deposition rate greatly depends not on the deposition temperature but on the reaction pressure oxygen flow rate and sputter power,. when the sputter powder is low ATO thin films with (110) preferred orientation are deposited. And when the sputter power is high (110) prefered orientation appeares with decreasing of oxygen flow rate and increasing of suputte-ring pressure.

  • PDF

액셜 피스톤 펌프 . 모터의 피스톤 구면부 정압 윤활특성 (Hydrostatic Bearing Characteristics of Slipper in Piston Pump . Motor)

  • 박경민;김종기;오석형;송규근;정재연
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2001년도 제34회 추계학술대회 개최
    • /
    • pp.186-193
    • /
    • 2001
  • In the high pressure state, the leakage flow rate of hydraulics is one of serious problems and the great reason to decrease the volume efficiency. In this paper, I tried to clarify tribology characteristics for the slipper hydrostatic bearing in swash plate type axial piston pumps and motors by means of experiment . I measured the leakage flow rate between swash plate and piston shoe with change the supply pressure and oil temperature at a swash plate angle of 0。 . And I also investigated the slipper pocket pressure and calculated oil film thickness for theoretical method. So. 1 have analyzed the tribology characteristics of hydrostatic bearing for leakage flow rate and oil film thickness with oil temperature and supply pressure.

  • PDF

양극산화 처리된 5083 알루미늄 합금의 해수 내 유속변화에 따른 전기화학적 손상 특성 (Electrochemical Damage Characteristics of Anodized 5083 Aluminum Alloy with Flow Rate in Seawater)

  • 박일초;김성종
    • 한국표면공학회지
    • /
    • 제49권4호
    • /
    • pp.349-356
    • /
    • 2016
  • In this study, electrochemical damage behaviors with flow rate were investigated for anodized 5083 aluminum alloy in seawater. As the results of anodic polarization experiments and potentiostatic experiments at +1.0 V (vs. SSCE), the non-flow condition presented largely damaged surface resulting from a tendency of local pitting damage. Under various flow rate conditions, however, less surface damages under the application of anodic potential was obtained which is attributed to no accumulation of $H^+$ and $Cl^-$ ions on the surface. On the other hand, the results of the potentiostatic experiments at -1.0 V (vs. SSCE) with flow rate showed that anodized 5083 aluminum alloys could achieve the effective cathodic protection by low cathodic protection current density less than $2.61{\times}10^{-7}A/cm^2$ even under high flow rate of 1 m/s.

증착 온도 및 수소 유량에 따른 MZO 박막의 구조적 및 전기적 특성 (Structural and Electrical Characteristics of MZO Thin Films Deposited at Different Substrate Temperature and Hydrogen Flow Rate)

  • 이지수;이규만
    • 반도체디스플레이기술학회지
    • /
    • 제17권2호
    • /
    • pp.6-11
    • /
    • 2018
  • In this study, we have studied the effect of substrate temperature and hydrogen flow rate on the characteristics of MZO thin films for the TCO(Transparent conducting oxide). MZO thin films were deposited by RF magnetron sputtering at room temperature and $100^{\circ}C$ with various $H_2$ flow rate(1sccm~4sccm). In order to investigate the effect of hydrogen gas flow rate on the MZo thin film, we experimented with changing the hydrogen in argon mixing gas flow rate from 1.0sccm to 4.0sccm. MZO thin films deposited at room temperature and $100^{\circ}C$ show crystalline structure having (002), (103) preferential orientation. The electrical resistivity of the MZO films deposited at $100^{\circ}C$ was lower than that of the MZO film deposited at room temperature. The decrease of electrical resistivity with increasing substrate temperature was interpreted in terms of the increase of the charge carrier mobility and carrier concentration which seems to be due to the oxygen vacancy generated by the reducing atmosphere in the gas. The average transmittance of the MZO films deposited at room temperature and $100^{\circ}C$ with various hydrogen gas flow was more than 80%.