• Title/Summary/Keyword: Flow rate Control

Search Result 2,002, Processing Time 0.03 seconds

무게 측정에 의한 원료 정량 투입 제어 방법 (A method for feeding flow rate control by measuring weight)

  • 권오정;황일영;이광순
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1992년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 19-21 Oct. 1992
    • /
    • pp.937-940
    • /
    • 1992
  • A cost-saving feeding rate contro method for a batch reaction process is proposed by reconfigurating the flow rate control loop where the feeding rate is estimated by differentiating weight measurement. While the existing control methods require either a flow rate measurement device or a flow rate estimator, the proposed method is devised not to require neither of these facilities by directly controlling the tank weight with a time-varying set point. Experimental evaluation in a pilot-scale unit shows that the proposed method can significantly reduce the actuator hunting of the existing method where the flow rate is estimated by differentiating the weight measurement.

  • PDF

지열순환펌프 유량변화에 따른 지열히트펌프시스템의 에너지 성능 평가 (A Study on the Geothermal Heat Pump System Performance Analysis according to Water Flow Rate Control of the Geothermal Water Circulation Pump)

  • 정영주;조재훈;김용식;조영흠
    • 한국태양에너지학회 논문집
    • /
    • 제34권6호
    • /
    • pp.103-109
    • /
    • 2014
  • It is important to control the amount of supply water flow rate at all kinds of HVAC systems in order to maintain IAQ and energy efficiency. The most of buildings installed geothermal heat pumps is using fixed water flow rate in spite of the excellent performance of geothermal heat pumps. Especially when the air-conditioning load is low, the flow rate control may be possible to save energy to operate. However, it is effective to apply the variable flow control system in order to reduce energy consumption. Therefore, the purpose of this study, change a water flow rate and improve the whole performance of the geothermal heat pump. Geothermal heat pump system is modeled after the selection of the applied building, by setting the flow rate control to be analyzed through a simulation of performance evaluation. Building energy saving according to the flow rate of the ground circulating water analyze quantitatively and to investigate the importance of the flow control.

주입식 총유량 자동제어방식 분관 방제기의 개발 (A Direct Injection-mixing Total-flow-control Boom Sprayer System)

  • 구영모
    • Journal of Biosystems Engineering
    • /
    • 제21권2호
    • /
    • pp.155-166
    • /
    • 1996
  • A direct injection sprayer was designed using the concepts of injection mixing and total flow control, flowrate-based system compensating for the variation of forwarding speed. A metered rate, proportionally to the actual diluent flow rate, of a tracer chemical was injected directly into the diluent stream. The injection of chemical may improve the precision and safety of chemical application process. The control system was evaluated for the variables of the control interval, tolerances and sensitivities of flow regulation valve and injection pump. Performance of the system was assessed as that the response time of flow rate, response time of injection rate, absolute steady state error, and the coefficient of variance(C.V.) of concentration were 8.5 and -0.53 seconds, 0.067 lpm(0.8%) and 3.15%, respectively, at optimal parameters of control interval of 1.0 sec, fast sensitivity of flow regulation valve, medium sensitivity of injection pump and medium tolerance of flow rate. Performance of the system can be improved by increasing the sensitivity of flow regulating valve and employing a high resolution velocimeter, such as Doppler radar.

  • PDF

하이브리드 로켓의 추력제어를 위한 산화제 유량제어 연구 (Oxidizer Flow Rate Throttling for Thrust Control of Hybrid Rocket)

  • 김계환;문근환;김진곤;문희장
    • 한국항공운항학회지
    • /
    • 제22권4호
    • /
    • pp.93-98
    • /
    • 2014
  • In this study, control of oxidizer mass flow rate and verification of control system were performed for hybrid rocket thrust control application. Oxidizer flow control system consists of ball valve and stepping motor where gaseous oxygen was used for oxidizer at feeding pressure of 10, 20 and 30 bar. According to experimental results, the oxidizer mass flow rate showed a relatively linear increment as ball valve open angle increases regardless of feeding pressure. In addition, the level of the oxidizer flow rate was kept almost constant at each sequence of flow control with ball valve during the 20 seconds of operation.

Changes in Pressure-Flow Control Characteristics of Shunt Valves by Intracranial Pressure Pulsation: an In Vitro Study

  • Lee, Chong-Sun;Kim, Joo-Young
    • 대한의용생체공학회:의공학회지
    • /
    • 제26권4호
    • /
    • pp.193-197
    • /
    • 2005
  • Shunt valves used to treat patients with hydrocephalus were tested to investigate influence of intracranial pressure pulsation on their flow control characteristics. Five commercial shunt valves were tested in the flow loop that simulates pulsed flow under pressure pulsation. As 20cc/hr of flow rate was adjusted at a constant pressure, application of $40mmH_2O$ of pressure pulse increased the flow rate by $67.9\%.$ As a 90cm length catheter was connected to the valve outlet, increase in the flow rate was substantially reduced to $17.5\%.$ As the flow rate was adjusted to 40cc/hr at a constant pressure, increase in the flow rate was $51.1\%$ with the same pressure pulsation of $40mmH_2O$. The results indicated that pressure-flow control characteristics of shunt valves implanted above human brain ventricle is quite different from those obtained by syringe pump test at constant pressures right after manufacture. The influence of pressure pulsation was observed to be more significant at low flow rate and the flexibility of the outlet silicone catheter was estimated to significantly reduce flow increase due to pressure pulsation.

오리피스를 이용한 엔진 윤활시스템 유량분배 제어 (Oil Flow Distribution Control of Engine Lubrication System Using Orifice Component)

  • 윤정의
    • Tribology and Lubricants
    • /
    • 제22권1호
    • /
    • pp.47-52
    • /
    • 2006
  • It is very important to control pressure and flow rate distribution on each component of engine lubrication network. Sometimes many kinds of orifice are used to control flow rate in the hydraulic lubrication field. In this study orifices were adopted on the lubrication network to control oil flow rate distribution. And unsteady transient flow network analysis was carried out to find out the effects of orifices on the engine oil circuit system.

산업용 밸브의 유량제어 시스템 설계 (Flow Rate Control System Design for the Industrial Valve)

  • 최정주
    • 한국산학기술학회논문지
    • /
    • 제21권1호
    • /
    • pp.387-392
    • /
    • 2020
  • 본 논문은 산업용 밸브의 유량제어시스템을 제안하였다. 산업용 밸브는 주로 배관시스템에 장착되어 유량 및 압력 제어에 사용된다. 제어밸브의 구조 및 작동 방식은 설치환경과 작업용도에 따라 상이하다. 밸브는 그 형태에 따라 그루브 밸브, 버터플라이 밸브 및 볼 밸브 등으로 분류되고, 구동방식은 모터를 이용하거나, 유압 및 공압을 이용하는 것이 일반적이다. 제어밸브를 이용한 유량제어시스템은 유량을 계측하여 피드백시스템을 구현하여야 하지만, 본 논문에서는 고가의 유량센서를 사용하지 않고 밸브의 개폐에 따른 유량변화를 실험하여 밸브 전후단의 압력차와 개폐정도를 이용하는 방법을 제안하였다. 밸브의 유량은 유량계수를 이용하여 밸브 전후단의 압력차와 밸브의 개폐정도로 표현할 수 있으므로 이를 이용하여 유량제어시스템을 설계하였다. 제어입력에 따른 밸브의 개폐를 나타내는 전달함수는 신호압축법을 이용하여 구하였으며, 이를 이용하여 밸브 스템의 명령추종성능을 향상시킬 수 있는 외란관측기를 설계하였다. 제안된 제어시스템의 성능을 검증하기 위해 제어밸브 전후단에 압력센서를 장착하여 제안된 제어방법의 성능이 유량센서를 이용한 경우에 준함을 확인하였다.

시스템분배기 소음방지 및 성능개선방안 연구 (A Study on the Noise Reduction and Performance Improvement of the Hot Water Distributing System)

  • 김용기;이태원;한태수;유선학
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1055-1060
    • /
    • 2009
  • Noise is one of the major environmental problems in human life. But hot water distributers with the flow rate control valve bring about often noise according to the heating control condition in residential buildings. The sound power level increased as the flow rate and pressure difference increased. And thus, experimental analyses for the flow rate control and the pressure difference control were carried out in this study to reduce the noise emitted from the flow rate control valve. As the results, the flow rate control method using a SMA(Shape Memory Alloy)-valve and the flow rate control system using a pressure difference sensor can be expected to control noise in the region of below 50 dB of sound power level.

  • PDF

Adaptive digital control system of flow rates for an OTEC plant

  • Nakamura, Masatoshi;Uehara, Haruo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1987년도 한국자동제어학술회의논문집(한일합동학술편); 한국과학기술대학, 충남; 16-17 Oct. 1987
    • /
    • pp.753-758
    • /
    • 1987
  • The purpose of ocean thermal energy conversion (OTEC) plant control is to provide stable power efficiently by appropriately regulating the seawater flow rates and the working fluid flow rate under conditions of continually changing seawater temperatures. This paper describes digital control of working fluid flow rate based on an adaptive control theory for the "Imari 2" OTEC plant at Saga University. Provisions have been made for linkage between the software of the adaptive control theory and the hardware of the OTEC plant. In implementing the working fluid flow rate control, if persistency of excitation conditions are lost, the algorithm of identification often exhibits bursting phenomena. To avoid this difficulty, the stopping-and-starting rule for identification was derived and was used for the working fluid flow rate control. Satisfactory control performance was then obtained by using this digital control system.ol system.

  • PDF

파워 스티어링용 베인 펌프 유량 제어부 설계에 관한 연구 (A Study on the Design of Flow Control Valve Attached to Vane Pump for Power Steering)

  • 이윤태
    • 한국생산제조학회지
    • /
    • 제9권5호
    • /
    • pp.87-95
    • /
    • 2000
  • The numerical analysis and the experiments are carried out to develop the design program for the flow control valve attached to the vane pump for power steering. The factors affecting the flow rate characteristics are analyzed by the experiments and the numerical analysis. The results are summarized as follows; (1) the main factors affecting to the first and second control flow rate are the diameter of big and small rod of the spool. (2) the cut off is mainly affected by the main spring constant, the initial displacement of main spring and the small diameter of the spool. (3) the dropping slope characteristics are decided by the chamfer of spool and the dynamic characteristics of the spool.

  • PDF