• Title/Summary/Keyword: Flow quality

Search Result 3,363, Processing Time 0.032 seconds

A study on improvement of painting quality through a de-painting phenomenon of KUH-1 tail blade (한국형 기동헬기 꼬리 날개 디페인팅 현상을 통한 도장 품질 향상에 관한 연구)

  • Chang, In-Ki;Kim, Young-Jin;Seo, Hyun-Soo;Jeon, Boo-Il
    • Journal of Korean Society for Quality Management
    • /
    • v.42 no.3
    • /
    • pp.325-338
    • /
    • 2014
  • Purpose: The purpose of this study was to explain de-painting phenomenon of KUH-1 tail blade and to propose useful solution of it by test. The proposed solution was evaluated by real flight, and then it applied to mass product to improve the paint qual ity of KUH-1 tail blade. Methods: This study investigated an adhesive ability of primer following surface sanding condition. The cross cut and scratch test were conducted to evaluate the adhesive strength. And the water flow test was designed to simulate a real flight condition under rain. Through water flow test, an optimal condition of tail blade to prevent a de-painting phenomenon was deduced. Finally, the improvement method was evaluated by real flight under rain. Results: The results of this study are as follows; The sequential polishing was most excellent method in primer painting quality. The results of test including cross cut, scratch and water flow showed that MIL-DTL-53039 paint with epoxy primer has excellent adhesive ability. To proof the effect of improvement, a real flight during a rain condition was conducted. Finally, the comparison between original and improved configuration was conducted. Conclusion: The painting quality of KUH-1 tail blade was improved through deriving an optimal painting condition. In detail, a condition of optimal sanding and a sort of primer and paint was showed. Finally, the reliability of tail blade was guaranteed through improving the quality of painting.

Optimal Sizing of Intercepting Flow for Reducing Pollution Loads Caused by CSOs (CSOs 저감을 위한 차집관거 최적화 시스템)

  • Kong, Min-Keun;Bae, Ki-Hyun;Kang, Woo-Young
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.4
    • /
    • pp.418-424
    • /
    • 2004
  • An abrupt high pollution loads in combined sewer systems is believed to be caused by first flushing actions and the resuspension of sediments deposited in sewers. Therefore, pollution loads in each flow regulator have a different tendency. This systems control intercepting flow in each flow regulator using water quality and water level. A desired quantity of intercepting flow was adjusted and the necessary slide position for a constant intercepting is calculated by Optimization programming. This systems make it possible to reduce pollution loads caused by CSOs to water body, may be alternative for the stable operation of STP through improving water quality to STP.

An Improved Mechanistic Critical Heat Flux Model for Subcooled Flow Boiling

  • Young Min Kwon;Soon Heung Chang
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.10a
    • /
    • pp.552-557
    • /
    • 1997
  • Based on the bubble coalescence adjacent to the heated wall as a flow structure for CHF condition, Chang and Lee developed a mechanistic critical heat flux (CHF) model for subcooled flow boiling. In this paper, improvements of Chang-Lee model are implemented with more solid theoretical bases for subcooled and low-quality flow boiling in tubes. Nedderman-Shearer's equations for the skin friction factor and universal velocity profile models are employed. Slip effect of movable bubbly layer is implemented to improve the predictability of low mass flow. Also, mechanistic subcooled flow boiling model is used to predict the flow quality and void fraction. The performance of the present model is verified using the KAIST CHF database of water in uniformly heated tubes. It is found that the present model can give a satisfactory agreement with experimental data within less than 9% RMS error.

  • PDF

Evaluating Effect of Density Flow from Upstream on Vertical Distribution of Water Quality at the Paldang Reservoir (팔당호 수질의 연직분포에 대한 밀도류 영향 평가)

  • Kong, Dongsoo
    • Journal of Korean Society on Water Environment
    • /
    • v.35 no.6
    • /
    • pp.557-566
    • /
    • 2019
  • Paldang is a river reservoir in the Midwest of Korea, which is a drinking water source for the metropolitan area. Since the Paldang Reservoir is shallow, and has a short hydraulic residence time, its water quality is directly impacted by two incoming rivers, the north Han River (NHR) and the south Han River (SHR). The NHR has different seasonal patterns of water temperature from the SHR because the NHR is greatly impacted by the discharge water from upstream dams. The electrical conductivity (EC) and other material concentrations of the SHR are usually higher than those of the NHR because its basin is limestone-based. The difference in water temperature in the two rivers causes density flow, and the distribution of the EC within the reservoir can be an indicator for monitoring density flow. From the vertical gradient of the EC at the dam site, from spring to fall, it was confirmed that the SHR flowed into the upper layer, and the NHR flowed into the lower layer, and vice versa at other times. The relative difference (RD) of the EC between the upper layer and the lower layer at the dam site was used as an indicator for density flow. The RD of the EC showed a very significant correlation with the RD of total organic carbon (r = 0.70, p < 0.001) and the RD of total nitrogen (r = 0.58, p < 0.01). This relationship is based on the assumption that the difference in electrical conductivity and water quality between the SHR and the NHR is constant. However, in many cases this assumption is inconsistent. Thus, further study is needed on more suitable indicators to evaluate the impact of density flow on water quality.

Estimation of the hydraulic conductivity profile in fractured rocks using the borehole flowmeter test (시추공 유속 검층을 이용한 암반 대수층의 수리전도도 분포 산정)

  • 구민호;차장환
    • The Journal of Engineering Geology
    • /
    • v.12 no.3
    • /
    • pp.257-271
    • /
    • 2002
  • The vertical distribution of hydraulic conductivity of 3 boreholes located at Kongju National University was estimated by the ambient flow and the pump-induced flow measurements using a heat-pulse flowmeter. The ambient flow measurements showed that a great amount of groundwater (1~2 m$^3$/day) flowed in the boreholes through the conductive fractures. The analyzed conductivity profiles we similar to those of the packer test performed for the same boreholes. The conductive fractures in which the differential net flow changed greatly could be identified by the BIPS logging. The water-quality logging data showed that quality of groundwater changed abruptly at some depths of the boreholes. This change in water quality can be attributed to the presence of conductive fractures that have resulted in the mixing of groundwater of different quality flowing in different fracture channels. However, compared to the flowmeter test, the water-quality logging showed low capability in identifying locations of conductive fractures.

A Study on the Operational Forecasting of the Nakdong River Flow with a Combined Watershed and Waterbody Model (실시간 낙동강 흐름 예측을 위한 유역 및 수체모델 결합 적용 연구)

  • Na, Eun Hye;Shin, Chang Min;Park, Lan Joo;Kim, Duck Gil;Kim, Kyunghyun
    • Journal of Korean Society on Water Environment
    • /
    • v.30 no.1
    • /
    • pp.16-24
    • /
    • 2014
  • A combined watershed and receiving waterbody model was developed for operational water flow forecasting of the Nakdong river. The Hydrological Simulation Program Fortran (HSPF) was used for simulating the flow rates at major tributaries. To simulate the flow dynamics in the main stream, a three-dimensional hydrodynamic model, EFDC was used with the inputs derived from the HSPF simulation. The combined models were calibrated and verified using the data measured under different hydrometeological and hydraulic conditions. The model results were generally in good agreement with the field measurements in both calibration and verification. The 7-days forecasting performance of water flows in the Nakdong river was satisfying compared with model calibration results. The forecasting results suggested that the water flow forecasting errors were primarily attributed to the uncertainties of the models, numerical weather prediction, and water release at the hydraulic structures such as upstream dams and weirs. From the results, it is concluded that the combined watershed-waterbody model could successfully simulate the water flows in the Nakdong river. Also, it is suggested that integrating real-time data and information of dam/weir operation plans into model simulation would be essential to improve forecasting reliability.

Disparity Refinement near the Object Boundaries for Virtual-View Quality Enhancement

  • Lee, Gyu-cheol;Yoo, Jisang
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.5
    • /
    • pp.2189-2196
    • /
    • 2015
  • Stereo matching algorithm is usually used to obtain a disparity map from a pair of images. However, the disparity map obtained by using stereo matching contains lots of noise and error regions. In this paper, we propose a virtual-view synthesis algorithm using disparity refinement in order to improve the quality of the synthesized image. First, the error region is detected by examining the consistency of the disparity maps. Then, motion information is acquired by applying optical flow to texture component of the image in order to improve the performance. Then, the occlusion region is found using optical flow on the texture component of the image in order to improve the performance of the optical flow. The refined disparity map is finally used for the synthesis of the virtual view image. The experimental results show that the proposed algorithm improves the quality of the generated virtual-view.

Development of the CAP Water Quality Model and Its Application to the Geum River, Korea

  • Seo, Dong-Il;Lee, Eun-Hyoung;Reckhow, Kenneth
    • Environmental Engineering Research
    • /
    • v.16 no.3
    • /
    • pp.121-129
    • /
    • 2011
  • The completely mixed flow and plug flow (CAP) water quality model was developed for streams with discontinuous flows, a condition that often occurs in low base flow streams with in-stream hydraulic structures, especially during dry seasons. To consider the distinct physical properties of each reach effectively, the CAP model stream network can include both plug flow (PF) segments and completely mixed flow (CMF) segments. Many existing water quality models are capable of simulating various constituents and their interactions in surface water bodies. More complicated models do not necessarily produce more accurate results because of problems in data availability and uncertainties. Due to the complicated and even random nature of environmental forcing functions, it is not possible to construct an ideal model for every situation. Therefore, at present, many governmental level water quality standards and decisions are still based on lumped constituents, such as the carbonaceous biochemical oxygen demand (CBOD), the total nitrogen (TN) or the total phosphorus (TP). In these cases, a model dedicated to predicting the target concentration based on available data may provide as equally accurate results as a general purpose model. The CAP model assumes that its water quality constituents are independent of each other and thus can be applied for any constituent in waters that follow first order reaction kinetics. The CAP model was applied to the Geum River in Korea and tested for CBOD, TN, and TP concentrations. A trial and error method was used for parameter calibration using the field data. The results agreed well with QUAL2EU model predictions.

A Study on Heat Transfer Characteristics in Flow Boiling of Pure Refrigerants and Their Mixtures in Horizontal Tube (수평 전열관내 유동비등하는 순수냉매와 혼합냉매의 열전달 특성에 관한 연구)

  • 임태우;한규일
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.2
    • /
    • pp.144-151
    • /
    • 2003
  • An experimental study was carried out in a uniformly heated horizontal tube to examine heat transfer characteristics of pure refrigerants, R134a and R123, and their mixtures during flow boiling. The flow pattern was also observed through tubular sight glasses with an internal diameter of 10 mm located at the inlet and outlet of the test section. Tests were run at a pressure of 0.6 MPa and in the heat flux ranges of 5~100 kW/$m^2$, vapor Quality 0~100 percent and mass velocity of 150-600 kg/$m^2$s. The observed flow patterns were compared to the flow pattern map of Kattan et al., which predicted well the present data over the entire range of mass velocity employed in this study. Heat transfer coefficients of the mixture were less than the interpolated values between pure fluids both in the low quality region where the nucleate boiling is dominant and in the high quality region where the convective evaporation is dominant.

Improvement and Application of Total Maximum Daily Load Management System of Korea: 1. Calculation of Total Amount of Pollutant Load in the Anyangcheon Watershed (우리나라 오염총량관리제도의 개선 및 적용: 1. 안양천 유역의 오염부하량 산정)

  • Kim, Kyung-Tae;Chung, Eun-Sung;Kim, Sang-Ug;Lee, Kil Seong;Seong, Jin-Young
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.6
    • /
    • pp.972-978
    • /
    • 2009
  • This study modifies the present total maximum daily load (TMDL) system of Ministry of Environment and applies to the Anyangcheon watershed. Hydrologic Simulation Program-FORTRAN (HSPF) model is used to simulate both runoff and non-point source pollution, simultaneously, instead of QUAL2E. The drought flow (355th daily flow) is proposed for the target water quantity since it is easier to satisfy low flow (275th daily flow) for the target water quality than drought flow. The increase of discharge is more than the increase of pollutant load except for the period under low flow. The measured unit loads for non-point source are used to consider the regional runoff characteristics. The measured water quantity and quality data are used since the ministry of environment supports only water quality. This analysis results show some reasons for the improvement of the present TMDL system of Korea.