• 제목/요약/키워드: Flow quality

검색결과 3,373건 처리시간 0.042초

Flow Aggregation of Rate Controlled Round-Robin Scheduler

  • Kim, Ki-Cheon
    • ETRI Journal
    • /
    • 제26권4호
    • /
    • pp.351-359
    • /
    • 2004
  • Flow aggregation is a scalable method to provide quality of service (QoS) guarantees to a large number of flows economically. A round-robin scheduler is an efficient scheduling algorithm. We investigate flow aggregation using a round-robin scheduler and propose the use of periodic timer interrupts for rate control of the round-robin scheduler. The proposed flow aggregator is a single-stage scheduler compared to Cobb's two-stage flow aggregator consisting of an aggregator and non-aggregating scheduler. It is possible to implement flow aggregation in the existing routers with only a software upgrade. We also present a simulation study showing the delay behaviors of the proposed algorithm.

  • PDF

FAMILY MOLD의 유동 밸런스와 금형 내압에 관한 연구 (A Study on Flow Balance and Cavity Pressure in Family Mold)

  • 김태철;이대근;홍기복;김영근;박인수
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.603-607
    • /
    • 2002
  • Cavity pressure is a factor of what is occurring inside the mold and is used as one of the process parameters that control the overall injection molding cycle. The insight of cavity pressure is able to predict part quality and optimum process condition. In this paper, it is adapted ejector pin sensor to measure the cavity pressure and investigates the flow balance and the cavity pressure according to different runner thickness for adjusting the flow balance. Flow balance is very important to have not the poor results such as flash and warpage in the family mold. This paper predicted flow balance and cavity pressure using CAE analysis tool and compared with the test results. The results of analysis and test have a good agreement with the cavity pressure profile and flow pattern of the test.

  • PDF

Flow Pattern and Pressure Drop of Pure Refrigerants and Their Mixture in Horizontal Tube

  • Lim, Tae-Woo
    • Journal of Mechanical Science and Technology
    • /
    • 제19권12호
    • /
    • pp.2289-2295
    • /
    • 2005
  • Two-Phase flow pattern and pressure drop data were obtained for pure refrigerants R134a and R123 and their mixtures as test fluids in a horizontal tube. The flow pattern is observed through tubular sight glasses located at inlet and outlet of the test section. The flow map of Baker developed for air-water two-phase flow at atmospheric pressure failed to predict the observed flow patterns at the higher value of the mass velocity used in the present study. The map of Kattan et al. predicted the data well over the entire region of mass velocity selected in the present study. The measured pressure drop increased with an increase in vapor quality and mass velocity. A new two-phase multiplier was developed from a dimensional analysis of the frictional pressure drop data measured in the present experiment. This new multiplier was found successfully to correlate the frictional pressure drop.

Effect of Flow Inlet or Outlet Direction on Air-Water Two-Phase Distribution in a Parallel Flow Heat Exchanger Header

  • Kim, Nae-Hyun;Kim, Do-Young;Cho, Jin-Pyo;Kim, Jung-Oh;Park, Tae-Kyun
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제16권2호
    • /
    • pp.37-43
    • /
    • 2008
  • The air and water flow distributions are experimentally studied for a round header - ten flat tube configuration. Three different inlet orientation modes (parallel, normal, vertical) were investigated. Tests were conducted with downward flow configuration for the mass flux from 70 to $130kg/m^2s$, quality from 0.2 to 0.6, non-dimensional protrusion depth (h/D) from 0,0 to 0.5. It is shown that, for almost all the test conditions, vertical inlet yielded the best flow distribution, followed by normal and parallel inlet. Possible explanation is provided using flow visualization results.

철강 연속주조 슬라이드게이트 노즐 및 주형내 비대칭 유동 현상과 탕면 거동 (Asymmetric Flow Phenomena and Top Surface Behavior in Slide-Gate Nozzle and Mold during Continuous Casting of Steel)

  • 김민경;장태완;조성묵
    • Design & Manufacturing
    • /
    • 제18권3호
    • /
    • pp.22-29
    • /
    • 2024
  • Steel is one of the most widely used metals for various industries in the world. Over 95% of steels in the world is manufactured from continuous casting processes. During continuous casting, there are many phenomena including fluid flow, heat transfer, solidification, particle transport, etc. in mold regions. Molten steel continuously flows into the mold through the nozzle, and generates asymmetric flow pattern. The asymmetry of flow behaviors affects the behavior of surface slag/molten steel interface on the top of molten steel pool. These phenomena are influential on the quality of final steel products. This work investigates the asymmetric flow and the top surface behaviors in mold region with a slide-gate nozzle during continuous casting of steel slabs, by applying lab-scale water model experiments.

오염총량관리를 위한 의사결정 지원시스템 적용 (Application of a Decision Support System for Total Maximum Daily Loads)

  • 이혜영;박석순
    • 한국물환경학회지
    • /
    • 제20권2호
    • /
    • pp.151-156
    • /
    • 2004
  • A decision support system, Watershed Analysis Risk Management Framework(WARMF), was applied to the Kyungan Stream watershed, a tributary of Lake Paldang, for calculation of total maximum daily loads(TMDL). The WARMF system was developed by Systech Engineering, USA, and has been successfully used in several watersheds, for TMDL studies. The study area was divided into 14 sub-basins, based on digital elevation model(DEM). The integrated watershed and stream model of WARMF was validated by flow and BOD data measured during the year of 1999. There were reasonable agreements between model results and field data, both in water flow and BOD. The validated Kyungan WARMF was extensively utilized to study the quantitative relationship between waste loads and receiving water quality. Based on TMDL guideline at Paldang Lake and Kyungan Stream, the water quality criterion were set to be 3.0mg/L, 3.5mg/L, and 4.0mg/L at the watershed outlet. The allowable waste loads of BOD, both from point and non-point sources, were determined at each water quality criterion. From this study, it was concluded that the WARMF provided several advantages over the conventional application of watershed and stream models for TMDL study, such as time variable simulations, multiple possible soutions, and reduction loads for goal water quality, etc.

HSPF 유역모델을 이용한 낙동강유역 실시간 수문 유출 예측 (Operational Hydrological Forecast for the Nakdong River Basin Using HSPF Watershed Model)

  • 신창민;나은혜;이은정;김덕길;민중혁
    • 한국물환경학회지
    • /
    • 제29권2호
    • /
    • pp.212-222
    • /
    • 2013
  • A watershed model was constructed using Hydrological Simulation Program Fortran to quantitatively predict the stream flows at major tributaries of Nakdong River basin, Korea. The entire basin was divided into 32 segments to effectively account for spatial variations in meteorological data and land segment parameter values of each tributary. The model was calibrated at ten tributaries including main stream of the river for a three-year period (2008 to 2010). The deviation values (Dv) of runoff volumes for operational stream flow forecasting for a six month period (2012.1.2 to 2012.6.29) at the ten tributaries ranged from -38.1 to 23.6%, which is on average 7.8% higher than those of runoff volumes for model calibration (-12.5 to 8.2%). The increased prediction errors were mainly from the uncertainties of numerical weather prediction modeling; nevertheless the stream flow forecasting results presented in this study were in a good agreement with the measured data.

하절기 낙동강 창녕함안보 구간에서의 수질특성 및 영향인자의 상관관계 분석 (Analysis of the water quality and correlation of impact factors during summer season in changnyeong-haman weir section)

  • 정선영;김일규
    • 상하수도학회지
    • /
    • 제31권1호
    • /
    • pp.83-91
    • /
    • 2017
  • This study analyzed the correlation between Chl-a and water quality factors using characteristics of climate data, water quality factors, and various statistical analysis techniques during the summer season in the Nakdong River during the 2-year period. The purpose of this study is to provide the basic data for establishing water quality management policy in the Changnyeong-Haman weir section. From the end of July to the middle of August when algae mainly occur, both the years 2015 and 2016 are in the temperature range of $25{\sim}30^{\circ}C$, and the total precipitation of 2015 is less than that of 2016 in this period. As a result of comparing the concentration of Chl-a, the average Chl-a concentration of 2015 was higher than that of 2016, which seems to be related to the total precipitation in the occurrence of algae. The results of the correlation analysis showed that the correlation with PO4-P was significant at most points. As a result of the factor analysis, the first principal factor group classified PO4-P, NH3-N, TP, pH, flow rate, TN and this section seems to be influenced by phosphorus and nitrogen and flow rate.

오염등급과 유형화 분석의 연계에 의한 북한강 최북단 유역 소하천의 수질개선방안 연구 (Water Quality Improvement Plan for Small Streams in the Northernmost Basin of Bukhan River based on Pollution Grade and Typological Analysis Linkage)

  • 이용석;전만식;김문숙
    • 한국물환경학회지
    • /
    • 제32권3호
    • /
    • pp.281-290
    • /
    • 2016
  • In the northernmost basin of the Bukhan River, pollution sources can have a concentrated distribution. In these basins, small streams show low flow with various and rapid water quality change in low pollutants load. Therefore, a water quality improvement plan of small streams and main stem will be necessary to establish the characteristics of small streams. This study selected a representative Hwacheon-gun in the northernmost basin of the Bukhan River. Hydro analysis was performed with GIS tools using DEM. A total of 152 small streams were listed. A total of 51 survey locations were selected after applying the selection criteria. Flow rate and water qualities were investigated. Pollution sources and pollutants loads were calculated for each basin. Pollution grade and typological classification were performed by cluster analysis using standardized environmental condition factors. As a result, G04, G01, H01 locations were found to have the worst pollution grades whereas J01, P01, and P02 had less pollution. Typological analyses were able to classify six types for the surveyed small streams. An effective water quality improvement plan was obtained based on the results of pollution grade and typological analysis using environmental condition factors of this study.

팔당수계 주요하천 수질의 시·공간적 특성 (Spatio-temporal Water Quality Characteristics of Major Streams in Pal-dang Watershed)

  • 한미덕;이은주;오조교;김웅수;이창희;남궁은;정욱진
    • 한국물환경학회지
    • /
    • 제25권3호
    • /
    • pp.394-403
    • /
    • 2009
  • A total of 52 sampling sites were selected in the stream network of the upper Paldang watershed (e.g. Kyonan, Gapyeong, Jojong, Chengmi, Bockha, Yanghwa and Heuk streams). Over the time period of April 2007-February 2008, 1820 samples were collected and analyzed for physico-chemical variables of the upper watershed in order to investigate spatio-temporal water quality variation in particular the relationship with land use. Although temporal variations of water quality in each stream were similar and were significantly influenced by flow, spatial variations in each stream varied as physico-chemical characteristics of upper watershed. As a result of regression analysis, Biological Oxygen Demand (BOD), Chemical Oxygen Demand (COD), Total Nitrogen (T-N), and Total phosphorus (T-P) concentration were the most significantly and positively associated with people population density. It is necessary to manage not only water quality but also land use of upper watershed and flow flux.