• Title/Summary/Keyword: Flow force

Search Result 2,355, Processing Time 0.029 seconds

Estimation of Fluid Force for Renewable Energy Generation Using Vortex-induced Vibrations (와류기인진동을 이용한 신재생에너지 발전에서 유체력 추정연구)

  • Hongrae Park
    • New & Renewable Energy
    • /
    • v.19 no.2
    • /
    • pp.23-30
    • /
    • 2023
  • Vortex-induced vibrations are a type of flow-induced vibrations caused by alternating lift forces. With increasing demand for renewable energy, the application of vortex-induced vibrations to renewable energy has been widely studied. Vortex-induced vibrations for aquatic clean energy (VIVACE) converter is a renewable energy device that generates electricity from rivers or oceans using vortex-induced vibrations. To increase the design life and power harnessing capacity of the VIVACE converter, the estimation of fluid forces due to vortex-induced vibrations is essential. Herein, vortex-induced vibrations were experimentally tested, and their amplitude and frequency response were measured. The amplitude results showed four different branches: initial branch, upper branch, lower branch, and desynchronization range. According to the fluid force coefficient results, the maximum lift coefficient occurred at the upper branch. Additionally, a mathematical model is proposed to estimate fluid forces due to vortex-induced vibrations without using measurement devices. This mathematical model enables the estimation of fluid force coefficients and phase lag using amplitude and frequency response of vortex-induced vibrations.

Design analysis and simulation of an external helical gear

  • Jinlong Yang;Kwang-Hee Lee;Chul-Hee Lee
    • Journal of Drive and Control
    • /
    • v.20 no.4
    • /
    • pp.45-53
    • /
    • 2023
  • This study optimized the parameters of the helical gear based on the original external meshing helical gear pump, combined with the analysis of the stability and flow of the basic parameters of the equipment; herringbone gears were used to eliminate the axial force generated by the helical gears. An optimized helical gear rotor was built with NX. The error between the simulation and calculation results of pump displacement was 3.95% and the simulation results were valid. Analysis of the outlet pressure and lift changes (maximum change rates of 0.38% and 0.25%), pressure analysis of the XY center plane at different times in the same cycle (no pressure surge or drop), and analysis of the axial force of the primary and driven rotors (axis The axial force is close to 0) were performed. The results showed that the flow pulsation of the external gear pump was slight, the operation was smooth, vibration and friction were reduced, the wear of bearings and other components could be diminished, and the service life of the equipment was extended. The simulation results showed that the external gear pump met the design requirements.

Finding the optimum shape of the energy dissipator to minimize the impact force due to the dam break flow

  • Asrini Chrysanti;Sangyoung Son
    • Ocean Systems Engineering
    • /
    • v.14 no.2
    • /
    • pp.157-169
    • /
    • 2024
  • The sudden release of water from a dam failure can trigger bores on a flat surface and exert substantial impact forces on structures. This flow poses a high-risk flood hazard to downstream urban areas, making it imperative to study its impact on structures and devise effective energy dissipators to mitigate its force. In this study, a combination of Genetic Algorithm optimization and numerical modeling is employed to identify the optimal energy dissipator. The analysis reveals that a round arc-shaped structure proves most effective, followed by a triangular shape. These shapes offer wide adaptability in terms of structure dimensions. Structures with higher elevation, especially those with round or triangular shapes, demonstrate superior energy dissipation capabilities. Conversely, square-shaped structures necessitate minimal height to minimize impact forces. The optimal width for dissipating energy is found to be 0.9 meters, allowing for effective wave run-up and propagation. Furthermore, the force exerted on structures increases with higher initial water levels, but diminishes with distance from the dam, highlighting the importance of placement in mitigating impact forces.

Development of A New Truss Model for RC Beams without Web Reinforcement (전단보강철근이 없는 RC보의 트러스 해석기법 연구)

  • Kim, Jee-Hoon;Jeong, Jae-Pyong;Kim, Woo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.1109-1114
    • /
    • 2001
  • This paper describes an attempt to develop a new truss model for reinforced concrete beams failing in shear based on a rational behavioral model. The key idea incorporated with truss model is the internal force state factor which is able to express global state of internal force flow in cracked reinforced concrete beams subjected to shear and bending. A new truss model using internal force state factor may provide a comprehensive result of shear strength in reinforced concrete beams without web reinforcement.

  • PDF

Development of Die Design System for Turbine Blade Forging (터빈 블레이드의 형단조 금형설계 시스템 개발)

  • 조종래
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1999.03b
    • /
    • pp.77-81
    • /
    • 1999
  • The predictions of metal flow forging load optimal die angle and preform size are not so easy in turbine blade forging. First of all the quality of final product is influenced by side force which is one of the significant factors. in this study slab method is applied to determine optimal die angle minimizing side force and the position of preform Finally drawing of die design is obtained in optimal die angle with developing tool that is composed of Visual Basic.

  • PDF

Average Flow Model with Elastic Deformation for CMP (화학적 기계 연마를 위한 탄성변형을 고려한 평균유동모델)

  • 김태완;구영필;조용주
    • Tribology and Lubricants
    • /
    • v.20 no.5
    • /
    • pp.284-291
    • /
    • 2004
  • We present a three-dimensional average flow model considering elastic deformation of pad asperities for chemical mechanical planarization. To consider the contact deformation of pad asperities in the calculation of the flow factor, three-dimensional contact analysis of a semi-infinite solid based on the use of influence functions is conducted from computer generated three dimensional roughness data. The average Reynolds equation and the boundary condition of both force and momentum balance are used to investigate the effect of pad roughness and external pressure conditions on film thickness and wafer position angle.

Numerical Analysis of Ship's Propulsion Mechanism of Two-Stage Weis-Fogh Type by Discrete Vortex Method

  • No, Gi-Deok;Han, Su-Hwan
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.11
    • /
    • pp.1548-1554
    • /
    • 2001
  • Flow patterns and dynamic properties of two-stage Weis-Fogh type ship propulsion mechanism are studied by a discrete vortex method. To study mutual interference between two wings, two cases are con sidered - wing motions with the same and reverse phases. The predicted flow patterns correspond to the available flow visualization results. Time histories of thrust and drag coefficients are also calculated, and the interference between the two wings are numerically clarified.

  • PDF

Characteristics of Sewage Flow in Sewer Pipes Deposited with Cohesive and Non-cohesive Solids (점착성 및 비점착성 고형물이 퇴적된 관로 내 하수흐름의 특성 조사)

  • Lee, Taehoon;Kang, Byongjun;Park, Kyoohong
    • Journal of Convergence for Information Technology
    • /
    • v.10 no.7
    • /
    • pp.153-159
    • /
    • 2020
  • In order to find out the condition of flow in sewer pipes, this study investigated the characteristics of tractive force of sewage flow estimated using actual measured values of water level, velocity, and flowrate in sewers located at uppermost portion in a treatment area during dry weather periods. When the scene of sewage flow was taken by CCTV after cohesive and non-cohesive solids (tofu and sand) were put on the sewer invert, it was found that the solids could be flushed without significant interruption. In sewer with slope of 0.00319, the frequency exceeding the minimum tractive force of sewage during a weekday was zero, while it was 10 per day with slope of 0.00603. During the week of the field observation, the event to exceed the minimum tractive force occurred once, suggesting that sewer odor would potentially increase. Maximum tractive force in sewer with steep slope was 2.9-3.1 N/㎡, but with gentle slope it decreased to 1.6-1.7N/㎡. It was also observed that the interval of time maintained below the criterion of minimum tractive force increased, during weekends compared to weekdays and for the sewage including non-cohesive particles which could enter combined sewers during a storm period. This study found that the sewer sediments formed by direct feces input into sewers, through sewer pipes which were designed meeting the standard sewer design criteria, could be flushed without staying as deposited solids state for a long time.

Analysis of Radial Air-shear Force on Magnetic Disks for Reducing the Spin-off of Lubricants

  • Kurita, M.;Shimizu, H.;Mizumoto, M.;Ootani, Y.
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2002.10b
    • /
    • pp.281-282
    • /
    • 2002
  • To reduce the spin-off of lubricants on a magnetic disk, which is caused by the radial component of shear force between the disk and air, we analyzed the air-velocity distribution and the air-shear force by three-dimensional large-eddy simulation (LES). This sensitivity analysis, on five design parameters, showed that disk/arm clearance and arm thickness have a greater effect on the mean radial air-shear force than the other parameters. The force on a disk optimized according to the optimum parameters is 12% less than the force on a conventional disk.

  • PDF

Vibration Analysis of Rotor System for Rotary Compressor Considering Hydrodynamic Force between Motor Rotor and Stator (전동기 공극부 냉매의 유막력을 고려한 로터리 압축기용 회전축계의 진동해석)

  • Kim, Yong-Han;Yang, Bo-Suk;Ahn, Byoung-Ha;Lee, Jang-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1058-1064
    • /
    • 2000
  • The analysis of dynamic behaviour of rotor system for the rolling piston type rotary compressor considering hydrodynamic force between motor rotor and stator is presented. In addition to considering other dynamic, loads such as large unbalance forces, gas force and bearing force, we consider the hydrodynamic force induced by the compressed fluid flow through the air gap between motor rotor and stator, and improve the analysis of vibration in rotary compressor. The Childs' method which based on Bulk-now and Hirs' turbulent lubrication model is used to calculate the rotordynamic coefficients due to hydrodynamic force of annular clearance in motor air gap.

  • PDF