• 제목/요약/키워드: Flow fluctuation

검색결과 610건 처리시간 0.026초

중간 열교환기를 이용한 열복합 증류탑의 운전성 향상 (Improved Operability in a Fully Thermally Coupled Distillation Column with an Intermediate Heat Exchanger)

  • 정수영;김영한
    • 제어로봇시스템학회논문지
    • /
    • 제12권9호
    • /
    • pp.945-953
    • /
    • 2006
  • Though a fully thermally coupled distillation column consumes less energy than an original column, it is not widely implemented in practice due to its operational difficulty. A new fully thermally coupled distillation column is proposed for the operability improvement, and its performance is investigated. The main improvement is the separation of a main column to give an upper and lower columns and the installation of an intermediate heat exchanger between them to regulate the fluctuation of product compositions. A proper manipulation of column pressure in the separated main columns made easy vapor flow without a compressor. The operability improvement is examined in a hexane process from the dynamic simulation using a commercial design software HYSYS. The simulation results indicate that the coupling among inputs and outputs is loosened to make easy manipulation of product compositions in the proposed distillation system.

4-레벨 인버터의 DC-링크 전압 균형을 위한 향상된 전압 제어 기법 (An Improved Voltage Control Scheme for DC-Link Voltage Balancing in a Four-Level Inverter)

  • 김래영;이요한;최창호;현동석
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권10호
    • /
    • pp.544-554
    • /
    • 1999
  • Multi-level inverters are now receiving widespread interest form the industrial drives for high power variable speed applications. Especially, for the high power variable speed applications, a diode clamped multi-level inverter has been widely used. However, it has the inherent problem that the voltage of the link capacitors fluctuates. This paper describes a voltage control scheme effectively to suppress the DC-link potential fluctuation for a diode clamped four-level inverter. The current to flow from/into the each link capacitor is analyzed and the operation limit is obtained when a conventional SVPWM is used. To overcome the operation limit, a modified carrier-based SVPWM is proposed. Various simulation and experiment results are presented to verify the proposed voltage control scheme for DC-link voltage balancing.

  • PDF

PIV/LIF에 의한 교반혼합기 유동의 난류 속도/농도장 측정 및 POD해석 (Simultaneous Measurement of Velocity and Concentration Field in a Stirred Mixer Using PIV/LIF Techniqueut and POD Analysis)

  • 정은호;윤상열;김경천
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2002년도 추계학술대회 논문집
    • /
    • pp.101-104
    • /
    • 2002
  • Simultaneous measurement of turbulent velocity and concentration field in a stirred mixer tank is carried out by using PIV/LIF technique. Instantaneous velocity fields are measured by a $1K\times1K$ CCD camera adopting the frame straddle method while the concentration fields are obtained by measuring the fluorescence intensity of Rhodamine B tracer excited by the second pulse of Nd:Yag laser light. Image distortion due to the camera view-angle is compensated by a mapping function. It is found that the general features of the mixing pattern are quite dependent on the local flow characteristics during the rapid decay of mean concentration. However, the small scale mixing seems to be independent on the local turbulent velocity fluctuation.

  • PDF

위상간섭을 이용한 사축식 액셜 피스톤 펌프의 압력맥동 감소에 대한 연구 (A Study on the Reduction in Pressure Ripples for a Bent-Axis Piston Pump by a Phase Interference)

  • 김경훈;최명진;이규원;장주섭
    • 한국정밀공학회지
    • /
    • 제21권9호
    • /
    • pp.103-110
    • /
    • 2004
  • Pressure ripples yield noise and vibration in hydraulic pipelines, which are inevitably generated by a fluctuation of flow rate in the pump mechanism, and such noise and vibration deteriorate the stability and accuracy of hydraulic systems. To reduce the pressure ripples, accumulator and hydraulic attenuator are normally used. In this study, parallel pipeline with a bent-axis piston pump is introduced to a hydraulic pipe system as a method for reducing the pressure ripples and using the transfer matrix method, the dynamic characteristics of the pipe system are analysed and compared with experimental results. The results show that the phase interference using parallel pipeline with a bent-axis piston pump is effective to reduce the pressure ripples in the hydraulic pipelines.

Free Surface Tracking for the Accurate Time Response Analysis of Nonlinear Liquid Sloshing

  • Cho Jin-Rae;Lee Hong-Woo
    • Journal of Mechanical Science and Technology
    • /
    • 제19권7호
    • /
    • pp.1517-1525
    • /
    • 2005
  • Liquid sloshing displays the highly nonlinear free surface fluctuation when either the external excitation is of large amplitude or its frequency approaches natural sloshing frequencies. Naturally, the accurate tracking of time-varying free surface configuration becomes a key task for the reliable prediction of the sloshing time-history response. However, the numerical instability and dissipation may occur in the nonlinear sloshing analysis, particularly in the long-time beating simulation, when two simulation parameters, the relative time-increment parameter a and the fluid mesh pattern, are not elaborately chosen. This paper intends to examine the effects of these two parameters on the potential-based nonlinear finite element method introduced for the large amplitude sloshing flow.

남한강 지역의 건기 시, 강우 시, 난분해성 유기물질 유출 특성 (Runoff Characteristics of Refractory Organic Matters from South-Han River Watershed during Rainfall Event and Dry Season)

  • 길경익;김태원;정명숙
    • 한국물환경학회지
    • /
    • 제27권3호
    • /
    • pp.306-313
    • /
    • 2011
  • In this paper, runoff characteristics of South-Han river watershed in terms of refractory organic matters were investigated. The concentrations of DOC, POC, R-DOC, R-POC in runoff and flow rates were determined by monitoring 27 times in dry season and 4 times in rainy season. The concentrations of the dissolved refractory organic matter, R-DOC was the lowest in fall and similar in the other dry seasons. The particulate refractory organic matter, R-POC showed less fluctuation than R-DOC. In summer, mass loading was the highest than other dry seasons. The concentrations of R-DOC, R-POC were showed to be affected by runoff volume. The mass loading grows higher as runoff volume gets higher.

Experiments of Turbulent Thermal Mixing Phenomena Using Parallel Non-Isothermal Water Jets

  • Kim, Y.K.;Kim, J.M.;Lee, Y.B.;J.S. Hwang;H.Y. Nam
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 춘계학술발표회논문집(2)
    • /
    • pp.36-41
    • /
    • 1996
  • Turbulent thermal mixing experiments by the injection of two parallel non-isothermal water jets have been performed. The turbulent velocities and fluctuations under the isothermal conditions have been measured using LDV system. The velocity vectors have been plotted in two dimensions from the data measured at 29$\times$16 points. The thermal mixing experiments also have been conducted, where we used 45 K-type thermocouples with a sheath diameter of 0.020" which were fixed with 5 mm distance in a line at a measured height. The measured heights were 5, 10, 20, 30, 40 cm from the upper end of rectangular nozzles. We measured the turbulent temperatures under the various flow velocity conditions with 12$^{\circ}C$ $\leq$ $\Delta$T $\leq$4$0^{\circ}C$. The sampling frequency and sampling time were about 420 Hz and 10 seconds, respectively. The measured results of equal velocity parallel jets were analyzed axially and radially to obtain the variation of temperature fluctuation.tion.

  • PDF

Open-Loop Responses of Droplet Vaporization to Linear Normal Acoustic Modes

  • Kim, S.Y.;W.S. Yoon
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2004년도 제22회 춘계학술대회논문집
    • /
    • pp.155-164
    • /
    • 2004
  • In order for studying pressure-coupled dynamic responses of droplet vaporization, open-loop experiment of an isolated droplet vaporization exposed to pressure perturbations in stagnant gaseous environment is numerically conducted, Governing equations are solved for flow parameters at gas and liquid phases separately and thermodynamic parameters at the interfacial boundary are matched for problem closure. For high-pressure effects, vapor-liquid interfacial thermodynamics is rigorously treated. A series of parametric calculations in terms of mean pressure level and wave frequencies are carried out employing a n-pentane droplet in stagnant gaseous nitrogen. Results show that wave instability in view of pressure-coupled vaporization response seems more susceptible at higher pressures and higher wave frequencies. Mass evaporation rate responding to pressure waves is amplified with increase in pressure due to substantial reduction in latent heat of vaporization. Augmentation of perturbation frequency also enhances amplification due to the reduction of phase differences between pressure perturbation and surface temperature fluctuation.

  • PDF

지하수위 변동 해석모델의 개발(II): 함양 특성 (Development of Analyzing Model of Groundwater Table Fluctuation(II): Characteristics of Recharge)

  • 김남원;김윤정;정일문
    • 대한토목학회논문집
    • /
    • 제33권6호
    • /
    • pp.2285-2291
    • /
    • 2013
  • 본 연구에서는 Kim et al. (2013)이 개발한 부정류상태에서의 지하수위 변동 해석모델을 이용하여 단위시간별 함양량을 산정하였다. 지하수위 변동 해석모델은 지하수의 흐름과 관련된 반응계수와 함양에 관련된 비산출율을 매개변수로 이용한다. 해석모델의 적용을 위해 제주도 한천지역의 관측정 중 강우에 대한 반응이 양호한 JW 공항과 JD 용담1지점에 대한 5년(2006-2010)간의 지하수위 관측자료를 이용하였다. 지하수위 해석모델은 국지적인 규모에서의 단위시간별(일별) 함양량 산정이 가능하며 지하수위 자료와 비교한 결과, 함양량과 매개변수가 지하수위를 잘 반영하고 있었다. 함양량 산정결과 JD 용담1 지점은 520.4~904.0mm (32.7~61.8%), JW 공항지점은 447.4~633.4mm (24.0~45.1%)로 나타났다. 개발된 해석모델은 지하수위 자료를 이용하여 매개변수를 추정과 단위시간별 함양량을 산정하는 방안으로 활용되기를 기대된다.

수정된 후방 플로팅 링 실을 적용한 7톤급 터보펌프 산화제 펌프의 진동 및 압력 측정 (Measurements of Vibration and Pressure of an Oxidizer Pump for a 7-tonf Turbopump with a Modified Rear Floating Ring Seal)

  • 배준환;곽현덕;최창호;최종수
    • Tribology and Lubricants
    • /
    • 제36권5호
    • /
    • pp.253-261
    • /
    • 2020
  • In this paper, we present an experimental investigation of the frequency characteristics and a visual inspection of an oxidizer pump with a modified rear-floating ring seal for a 7-tonf turbopump. An oxidizer pump typically operates at high rotational speeds and under cryogenic conditions. Despite its low hydraulic efficiency, the floating ring seal is frequently employed as a leakage control solution for turbomachinery because it effectively reduces abrasion by friction. When the oxidizer pump starts up, the floating ring moves excursively but locks up stably against the pump casing when the contact pressure increases. The compressive force on the floating ring depends on the hydrodynamic forces induced by the flow through the floating ring. This force is controlled by the nose position of the floating ring. Based on a validation test for a 7-tonf turbopump with two types of floating rings, we concluded that the floating ring with a small diameter nose can move easily with a low contact pressure in the cooling path. This leads to instability of the pressure fluctuation around the floating ring. In contrast, a floating ring with a large diameter nose has a high contact pressure and attaches strongly to the casing, which causes wear and frictional oxidation between the contact surfaces of the impeller and the floating ring.