비정체 로트 - 스트리밍 흐름공정 일정계획 (No-Wait Lot-Streaming Flow Shop Scheduling)

  • 윤석훈
    • 산업공학
    • /
    • 제17권2호
    • /
    • pp.242-248
    • /
    • 2004
  • Lot-streaming is the process of splitting a job (lot) into a number of smaller sublots to allow the overlapping of operations between successive machines in a multi-stage production system. A new genetic algorithm (NGA) is proposed for minimizing the mean weighted absolute deviation of job completion times from due dates when jobs are scheduled in a no-wait lot-streaming flow shop. In a no-wait flow shop, each sublot must be processed continuously from its start in the first machine to its completion in the last machine without any interruption on machines and without any waiting in between the machines. NGA replaces selection and mating operators of genetic algorithms (GAs), which often lead to premature convergence, by new operators (marriage and pregnancy operators) and adopts the idea of inter-chromosomal dominance. The performance of NGA is compared with that of GA and the results of computational experiments show that NGA works well for this type of problem.

소닉노즐을 이용한 벨 푸루버의 국제비교 (Inter-comparison of Bell Prover using Sonic Nozzles)

  • 최해만;박경암
    • 한국유체기계학회 논문집
    • /
    • 제7권1호
    • /
    • pp.24-29
    • /
    • 2004
  • The inter-comparison of standards is required to be recognized the calibration results. The sonic nozzle package is developed to do inter-comparison of the bell preyer used to calibrate many gas flow meters for industries. Four national metrology institutes (KRISS, CMS, CENAM, NEL) were participated in this inter-comparison. The deviation of calibration data from the average value was small at the low flow rate and large at the high flow rate, respectively At the high flow rate, the deviation was larger than the expected value from uncertainties asserted by NMIs. This means there are some problems in the uncertainty evaluation and experiment procedures in some of the participated NMIs.

Performance Study of Thrust Control Unit with the Various Geometric Shapes

  • Kim, Kyoung-Ryun;Park, Jong-Ho
    • International Journal of Fluid Machinery and Systems
    • /
    • 제9권4호
    • /
    • pp.354-361
    • /
    • 2016
  • This study aims to identify aerodynamic characteristics of the ramp tab, a mechanical deflector, by conducting a non-combustive experiment using compressed air and supersonic flow test equipment. With the ramp tabs installed symmetrically and asymmetrically on the outlet of the supersonic nozzle, the structure of the flow field, the thrust spoilage, the thrust deviation angle, and the lift/drag coefficients were derived and analyzed. The results show that the asymmetrically-installed ramp tabs are advantageous relative to the symmetrically-installed tabs in terms of the performance of thrust vector control, thrust deviation angle, and lift coefficient.

밸브 하류에 설치된 건식 초음파유량계의 편차특성 (Deviation Characteristics of Clamp-on Type Ultrasonic Flowmeter Installed in Downstream of Valves)

  • 이동근;조용
    • 한국유체기계학회 논문집
    • /
    • 제15권4호
    • /
    • pp.12-18
    • /
    • 2012
  • This study was performed to found out the deviations for clamp-on type ultrasonic flowmeter installed in downstream of valves. It was selected three types of two-path flowmeter mainly used for K-water as test. Experiment carried out to confirmed characteristics of deviation depending on the sensor location, straight pipe length and maker for 1-path, 2-path and 4-path combined 2-path flowmeter. It was selected two kinds of valves with 100 % and 50 % opening, butterfly valves and gate valves, for flow disturbance factor. Finally, we suggested number of sensors by maker, straight pipe length and installed location of sensors satisfying the tolerance depending on the experiment results.

연속용융도금라인에서 에어나이프 특성이 도금편차에 미치는 영향 (A Study on Coating Deviation Effect by Air Knife Characteristics in CGL)

  • Bae, Y.H.;Ahn, D.S.;Lee, S.H.
    • 한국정밀공학회지
    • /
    • 제10권3호
    • /
    • pp.57-68
    • /
    • 1993
  • Air Wiping technique is widely used because of easy and efficient coating control in present CGL. Coaring weight is decided by nozzle header pressure, strip line speed and distance between strip and nozzle. Coating defects are results from unbalance of these factors and coating equipment calibration inaccuracy. Therefore, this study is mainly dealing with the cause of coating defects such as edge overcoating and coating deviation. The coptimum working condition is suggested by formulated coating model using collected working data. We developed two demension analysis program for air flow in nozzle and calculated dynamic pressure and air velocity with this program. The productivity and coating guality are improved by applying the result of this reserach.

  • PDF

Tilt variation and wake turbulence in the otter board of a bottom trawl during fishing operations

  • KIM, Yong-Hae
    • 수산해양기술연구
    • /
    • 제53권4호
    • /
    • pp.337-348
    • /
    • 2017
  • The tension of warp from trawler and sea-floor contact can generate tilt and wake turbulence around otter boards. Preliminary measurements of otter board tilt and 3-D flow velocity during bottom trawl operations were taken using a vector instrument to investigate the effects of wake turbulence at the trailing edge of the otter board. Tilt data (i.e., yaw, pitch, and roll) at 1 Hz and flow data (velocities in the towing, lateral, and vertical directions) at 16 Hz were analyzed to determine their periods and amplitudes using global wavelet and peak event analyses. The mean period (${\pm}standard$ deviation) of the tilt from the peak event analysis ($5{\pm}2s$) was longer or double than that of flow velocity ($3{\pm}2s$). The two periods also had a significant linear relationship. The turbulence rate of flow was 30-50% at the trailing edge and was closely related to roll deviation. The frequency of phase difference ratios (i.e., peak time differences between tilts and flow periods) was significantly different from random occurrence in two trials, possibly due to side tidal effects. However, in the other trials, flow peaks were random, as shown by the even peak times between tilts and flows. Future studies should focus on reducing tilt variation, wake turbulence, and bottom contact to stabilize otter board motion.

열간 압연공정의 선단부 통판성 안정화 제어 (Mass-flow Stabilization Control of a Strip Head Part in Hot Rolling Process)

  • 황이철;박철재;백운보
    • 제어로봇시스템학회논문지
    • /
    • 제15권3호
    • /
    • pp.330-336
    • /
    • 2009
  • This paper studies on the new control algorithm for the mass-flow stabilization in strip head part of a hot strip mill. A new strip tension model in the strip head part is derived using the current deviation of two neighboring stands. The current deviation means a difference between a measured current and a lock-on current, where the lock-on current is set up when a strip tension or a looper angle reaches each target value or time is about 0.4sec, respectively. On the basis of the tension calculation model, a mill velocity of a backward stand is controlled to stabilize a strip mass-flow by PI control algorithm. Therefore, the mass-flow control for strip head part is executed from a metal-in time into a foreward stand till the looper works normally. It is known by the results of a computer simulation and an experiment that the proposed control algorithm is very effective in stabilizing the mass flow of the strip head part.

최적조류계산을 이용한 한계손실계수의 전력시장 적용 (Marginal Loss Factor using Optimal Power flow in Power Market)

  • 신동준;고용준;이효상;김진오
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권8호
    • /
    • pp.379-384
    • /
    • 2002
  • In the competitive electricity market, various pricing methods are developed and practiced in many countries. Among these pricing methods, marginal loss factor(MLF) can be applied to reflect the marginal cost of network losses. For the calculation of MLF, power flow method has been used to calculate system loss deviation. However, this power flow method shows some shortcomings such as necessity of regional reference node, and absence of an ability to consider network constraints like line congestion, voltage limit, and generation output limit. The former defect might affects adversely to the equity of market participants and the latter might generate an inappropriate price signals to customers and generators. To overcome these defects, the utilization of optimal power flow(OPF) is suggested to get the system loss deviation in this paper. 30-bus system is used for the case study to compare the MLF results by the power flow and the OPF method for 24-hour dispatching and pricing, Generator payment and customer charge are compared with these two methods also. The results show that MLF by OPF reflects the power system condition more faithfully than that of by the conventional power flow method

딜리버리 윈도우 로트-스트리밍 흐름 공정 문제 (Lot-Streaming Flow Shop Problem with Delivery Windows)

  • 윤석훈
    • 대한산업공학회지
    • /
    • 제30권2호
    • /
    • pp.159-164
    • /
    • 2004
  • Lot-streaming is the process of splitting a job (lot) into a number of smaller sublots and then scheduling these sublots in order to accelerate the completion of jobs in a multi-stage production system. Anew genetic algorithm (NGA) is proposed for an-job, m-machine, equal-size sublot lot-streaming flow shop scheduling problem with delivery windows in which the objective is to minimize the mean weighted absolute deviation of job completion times from due dates. The performance of NGA is compared with that of an adjacent pairwise interchange (API) method and the results of computational experiments show that NGA works well for this type of problem.

Micro-PIV 기법을 이용한 미세유로 내 두 유체 유동 측정 (Micro PIV measurements of two-fluid flows in a microchannel)

  • 성형진;김병재;류임정
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2004년도 추계학술대회 논문집
    • /
    • pp.90-93
    • /
    • 2004
  • Micro PIV was applied to measure velocity profiles of two-fluid flows in a microchannel. In this work, the two-fluid flow of two glycerol-water mixtures was measured for three cases $(\phi=0\;and\;\phi=0.2;\;\phi=0.1\;and\;\phi=0.5;\;\phi=0\;and\;\phi=0.6)$. The flow rates of two fluids were the same. The experimental velocity profiles agreed well with numerical simulations. However, a slight deviation was found in the fluid with low concentration. Rather than the effects of the varying refractive indices inside the channel, the high velocity gradient effect was thought as the main source of the deviation.

  • PDF