• 제목/요약/키워드: Flow defect

검색결과 347건 처리시간 0.031초

사출성형 공정에서 젯팅 현상에 관한 고찰 (A Study on the Jetting Phenomena in Injection Molding Process)

  • 류민영
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2002년도 금형가공 심포지엄
    • /
    • pp.125-131
    • /
    • 2002
  • Surface defects in injection molded parts are due to the unsteady flow of polymer melt which are related to the geometries of cavity and gate, the operational conditions of injection and the rheological properties of polymer. In this study we have examined jetting phenomena in injection molding process for three kinds of PCs which have different molecular weight and structure, PBT and PC/ABS alloy with several injection speeds. We have used various cavity shapes that are tensile, flexural and impact test specimens with various gate and cavity thicknesses. Through this study we have observed that the formation of surface defect associated with jetting during filling stage in injection molding is strongly related to die swell. This means that the jetting is strongly affected by the elastic property rather than the viscous property in viscoelastic characteristics of molten polymer. Large die swell would eliminate jetting however, the retardation of die swell would stimulate jetting. In the point of mold design, reducing the thickness ratio of cavity to gate can reduce or eliminate jetting and associated surface defects regardless of magnitude of elastic property. It also enlarges process window that can produce steady flow of polymer melt in injection molding.

  • PDF

비골 동맥 천공지 피판의 혈관 해부학 (Vascular Anatomy of Peroneal Perforator Flap)

  • 정덕환;한정수;황준성
    • Archives of Reconstructive Microsurgery
    • /
    • 제13권1호
    • /
    • pp.36-42
    • /
    • 2004
  • Materials and Methods: We studied 50 cases of peroneal perforating branch about branching pattern, course, length of vascular pedicle, and perforating level of the perforating cutaneous branches from Oct. 1985 to November 2003 by doppler flow meter and intraoperative findings. Results: 1) The perforating cutaneous branches were classified into four types, the Straight Branch (27cases), the Proximal Oblique Branch (11cases), the Branch from Muscular Artery (10cases), the Distal Oblique Branch(2 cases) respectively. The most common patten was Straight Branch, that was 54%. 2) There were 3 pathways of these branches, the most common one passed between the Soleus and Peroneus muscles(34 cases, 68%) 3) The length of vascular pedicle in Buoy Flap was variable from from 3 cm to 15 cm, but 32 cases(64%) were distributed between 5 cm and 6 cm. 4) The perforating level of branches were 5.9 cm in average from fibular neck to subcutaneous perforator artery 5) Peroneal Buoy Flap in possible to reconstruct both seperated bone and skin defect in some distance by One-Stage Operation and we can harvest maximal $8{\times}16cm$ sized flap in one perforating artery. If we include more two perforating artery, we get more wide flap which can cover large defect.

  • PDF

Study on the effect of corrosion defects on VIV behavior of marine pipe using a new defective pipe element

  • Zhang, He;Xu, Chengkan;Shen, Xinyi;Jiang, Jianqun
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제12권1호
    • /
    • pp.552-568
    • /
    • 2020
  • After long-term service in deep ocean, pipelines are usually suffered from corrosions, which may greatly influence the Vortex-Induced Vibration (VIV) behavior of pipes. Thus, we investigate the VIV of defective pipelines. The geometric nonlinearity due to large deformation of pipes and nonlinearity in vortex-induced force are simulated. This nonlinear vibration system is simulated with finite element method and solved by direct integration method with incremental algorithm. Two kinds of defects, corrosion pits and volumetric flaws, and their effects of depth and range on VIV responses are investigated. A new finite element is developed to simulate corrosion pits. Defects are found to aggravate VIV displacement response only if environmental flow rate is less than resonance flow rate. As the defect depth grows, the stress responses increase, however, the increase of the defect range reduces the stress response at corroded part. The volumetric flaws affect VIV response stronger than the corrosion pits.

최적조류계산을 이용한 한계손실계수의 전력시장 적용 (Marginal Loss Factor using Optimal Power Flow in Power Market)

  • 고용준;신동준;김진오;이효상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.509-511
    • /
    • 2001
  • In the competitive electricity market, various pricing methods are developed and practiced in many countries. Among these pricing methods, marginal loss factor(MLF) can be applied to reflect the marginal cost of network losses. For the calculation of MLF, power flow method has been used. However, it shows some shortcomings such as necessity of regional reference node, and absence of an ability to consider network constraints. The former defect might affect adversely to the equity of market participants and the latter might generate an inappropriate price signal. To overcome these defects, the utilization of optimal power flow(OPF) is suggested in this paper. 30-bus system is used for the case study to compare the MLF by the power flow and the OPF method for 24-hour dispatching and pricing.

  • PDF

Effects of Si cluster incorporation on properties of microcrystalline silicon thin films

  • Kim, Yeonwon;Yang, Jeonghyeon;Kang, Jun
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2016년도 추계학술대회 논문집
    • /
    • pp.181-181
    • /
    • 2016
  • Hydrogenated microcrystalline silicon (${\mu}c-Si:H$) films have attracted much attention as materials of the bottom-cells in Si thin film tandem photovoltaics due to their low bandgap and excellent stability against light soaking. However, in PECVD, the source gas $SiH_4$ must be highly diluted by $H_2$, which eventually results in low deposition rate. Moreover, it is known that high-rate ${\mu}c-Si:H$ growth is usually accompanied by a large number of dangling-bond (DB) defects in the resulting films, which act as recombination centers for photoexcited carriers, leading to a deterioration in the device performance. During film deposition, Si nanoparticles generated in $SiH_4$ discharges can be incorporated into films, and such incorporation may have effects on film properties depending on the size, structure, and volume fraction of nanoparticles incorporated into films. Here we report experimental results on the effects of nonoparticles incorporation at the different substrate temperature studied using a multi-hollow discharge plasma CVD method in which such incorporation can be significantly suppressed in upstream region by setting the gas flow velocity high enough to drive nanoparticles toward the downstream region. All experiments were performed with the multi-hollow discharge plasma CVD reactor at RT, 100, and $250^{\circ}C$, respectively. The gas flow rate ratio of $SiH_4$ to $H_2$ was 0.997. The total gas pressure P was kept at 2 Torr. The discharge frequency and power were 60 MHz, 180 W, respectively. Crystallinity Xc of resulting films was evaluated using Raman spectra. The defect densities of the films were measured with electron spin resonance (ESR). The defect density of fims deposited in the downstream region (with nonoparticles) is higher defect density than that in the upstream region (without nanoparticles) at low substrate temperature of RT and $100^{\circ}C$. This result indicates that nanoparticle incorporation can change considerably their film properties depending on the substrate temperature.

  • PDF

스퍼터링 법으로 증착한 CdS 박막의 광전도도 특성 평가

  • 허성기;장동미;최명신;안준구;성낙진;윤순길
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.81-81
    • /
    • 2008
  • Applications of CdS films in this study are to exhibit a high conductivity when they are exposed at light with visible wavelength and sequentially to show a low conductivity in dark state. For this purpose, CdS films should have a high photosensitivity, still maintaining a high conductivity at a visible light. In this study, CdS films were prepared at room temperature on glass substrates by rf magnetron sputtering. In order to increase the photo-conductivity in visible light, various defect levels should be located within the CdS band gap. In order to nucleate the defect sites within the CdS band gap, CdS films were deposited on glass substrates at room temperature using various $H_2$/(Ar+$H_2$) flow ratios by an rf magnetron sputtering. Through the investigation of the structural and photoconductive properties of CdS films by an addition of hydrogen, the relationship between photo- and dark-resistance in CdS films was investigated in detail. 200-nm-thick CdS films for photoconductive sensor applications were prepared at various $H_2$/(Ar+$H_2$) flow ratios on glass substrates at room temperature by rf magnetron sputtering. Sulfur concentration in CdS films crystallized at room temperature with (002) preferred orientation depends directly on the hydrogen atmosphere and the surface roughness of the films gradually increases with increasing hydrogen atmosphere. Films deposited at 8% of $H_2$/(Ar+$H_2$) exhibit an abrupt decrease of dark- and photo-resistance, showing a low photo-sensitivity ($R_{dark}/R_{photo}$). Onthe other hand, films deposited at a hydrogen atmosphere of 42% exhibit a photo-sensitivity of $5\times10^3$, maintaining a photo-resistance of an approximately $2\times10^4\Omega$/square. The dark- and photo-resistance values of CdS films were related with a composition, surface roughness, and defect sites within the band gap.

  • PDF

선천성 및 후천성 심질환의 개심술 (A Clinical Evaluatuin on Open Heart Surgery of Congenital and Acquired Heart Disease)

  • 김근호
    • Journal of Chest Surgery
    • /
    • 제12권1호
    • /
    • pp.33-42
    • /
    • 1979
  • The present study reports 41 cases of congenital and acquired heart diseases, who received open heart surgery under extracorporeal circulation [ECC] by Sarns Heart-Lung-Machine [HLM] at the Department of Thoracic and Cardiovascular Surgery, Hanyang University Hospital during the` period between July 1975 and February 1979. The priming of pump oxygenator was carried out by the hemodilution method using Hartman`s solution, whole blood, and fresh human plasma. The rate of hemodilution was in the average of 50.8 ml/kg. ECC was performed at the average perfusion flow rate of 85.0 ml/kg/min [2.43 L./ kg/2] and at moderate hypothermia. In the total cardiopulmonary bypass, arterial pressure ranged between 55 mmHg and 90 mmHg, but generally maintaining over 70 mmHg. Patient age ranged between 2 and 54 year old, in congenital heart diseases, between 2 and 28, in acquired heart diseases, between 17 and 54 Sex ratio of male to female was 20:21. The cases include a case of pulmonary valvular stenosis, 4 cases of atrial septal defect, 9 cases of ventricular septal defect, 9 cases of tetralogy of Fallot, 5 cases of pentalogy of Fallot, 3 cases of atypical multiple anomalies 7 cases of mitral stenosis or insufficiency, a case of myxoma in left atrium, and a case of ruptured aneurysm of Valsalva`s sinus. The surgical managements were 16 valvulotomy for pulmonary valvular stenosis, 2 Teflon patch graft closure and 5 simple suture closure of atrial septal defect, 16 Teflon patch graft closure and 5 simple suture closure of ventricular septal defect, 12 pericardial patch graft for infundibular stenosis of right ventricle, one anastomosis between left superior vena cava and right atrium, 2 open mitral commissurotomy, 5 mitral valve replacement using Starr-Edward`s ball valve, porcine xenograft by Hancock, by Carpentier-Edward, or Angell-Shiley, one removal of left atrial myxoma, and a repair of ruptured aneurysm of Valsalva`s sinus. Four [9.7%] out 41 cases expired postoperatively and the rest of 37 cases survived with satisfactory results. The causes of death were one coronary embolism in tetralogy of Fallot, 2 postoperative lower cardiac output in atypical multiple anomalies, and one right heart failure in large: ventricular septal defect with pulmonary hypertension.

  • PDF

개에서 발생한 우-좌 단락 심실 중격 결손 증례 (Right-to-left Shunting Ventricular Septal Defect in a Dog)

  • 윤수경;김보은;윤화영;최민철;윤정희
    • 한국임상수의학회지
    • /
    • 제32권4호
    • /
    • pp.343-346
    • /
    • 2015
  • 4년령의 중성화된 수컷 Dachshund가 만성적인 호흡곤란 및 청색증을 주증으로 내원하였다. 혈액검사에서 헤마토크리트 79.7%의 심각한 적혈구증가증이 확인되었다. 흉부 방사선 영상에서는 경도의 우심 종대가 관찰되었다. 심초음파 검사에서 좌심실유출로 대동맥판막 근위부에서 큰 심실 중격 결손이 확인되었으며, 도플러 검사에서 이 결손을 통한 우-좌 션트가 확인되었으며 조영 심초음파를 통하여 최종적으로 확진되었다. 이러한 진단적 결과 및 환자의 임상증상을 바탕으로 환자는 우-좌 단락 심실 중격 결손증으로 진단되었다. 사혈 및 산소 공급을 실시하였으나 환자는 내원 다음날 집에서 사망하였다. 본 증례보고에서는 심초음파를 통한 우-좌 단락 심실 중격 결손증의 진단을 서술하였다.

급성 뇌경색 환자에서 Deconvolution perfusion CT의 유용성 : Diffusion MRI와 비교 (The Usefulness of Deconvolution Perfusion CT in Patients with Acute Cerebral Infarction : Comparison with Diffusion MRI)

  • 은성종;김영근
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제26권3호
    • /
    • pp.25-31
    • /
    • 2003
  • 급성 허혈성 뇌경색 환자에서 Deconvolution 관류 전산화 단층촬영(computed tomography, CT)의 뇌혈류용적(cerebral blood volume, CBV), 뇌혈류(cerebral blood flow, CBF) 그리고 평균 조영제 통과 시간(mean transit time, MTT) 지도를 확산 강조(Diffusion weighted) MRI과 비교하여 그 유용성을 알아보고자 하였다. 뇌관류 CT와 확산강조 자기공명영상(diffusion weighted MR imaging, DWMRI)을 시행한 급성뇌경색 환자를 대상으로 Deconvolution 기법으로 획득한 CBV, CBF, MTT 지도에서 병변의 면적과 DWMRI의 병변의 면적을 비교 측정하여 일치도를 알아보았다. 또한, 병변 부위와 정상측 대칭부위의 MTT시간을 측정하여 차이를 알아보았다. 본 연구의 모든 예에서 CBV, CBF, 그리고 MTT 세 지도 모두 관류 결손을 인지할 수 있었고, 관류 결손이 인지되는 부위에서 MTT 시간의 현저한 지연이 있었다. 뿐만 아니라, MTT 지도의 결손부위 면적은 DWMRI 보다 크게 나타나 허혈성 패넘브라를 추측할 수 있었다. 결론적으로 Deconvolution 관류 CT의 지도를 이용하면 뇌경색의 조기진단뿐만 아니라 허혈 중심부, 그리고 허혈성 페넘브라를 예측할 수 있어 DWMRI에 비해 관류결손 부위의 혈류 역학적 상태의 평가나 효과적인 치료계획을 세우는데 보다 유용할 것으로 생각된다.

  • PDF

CMP 공정에서 슬러리 필터의 효율 개선에 관한 연구 (A Study on Improvement of Slurry Filter Efficiency in the CMP Process)

  • 박성우;서용진;김상용;이우선;김창일;장의구
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 반도체재료
    • /
    • pp.34-37
    • /
    • 2001
  • As the integrated circuit device shrinks to smaller dimensions, chemical mechanical polishing (CMP) process was required for the global planarization of inter-metal dielectric (IMD) layer with free-defect. However, as the inter-metal dielectrics (IMD) layer gets thinner, micro-scratches are becoming as major defects. Micro-scratches are generated by agglomerated slurry, solidified and attached slurry in pipe line of slurry supply system. To prevent agglomerated slurry particle from inflow, we installed 0.5${\mu}m$ POU (point of use) filter, which is depth-type filter and has 80% filtering efficiency for the $1.0{\mu}m$ size particle. In this paper, we studied the relationship between defect generation and pad count to understand the exact efficiency of the slurry filtration, and to find out the appropriate pad usage. Our preliminary results showed that it is impossible to prevent defect-causing particles perfectly through the depth-type filter. Thus, we suggest that it is necessary to optimize the flow rate of slurry to overcome depth type filters weak-point, and to install the high spray of de-ionized Water (DIW) with high pressure.

  • PDF