• 제목/요약/키워드: Flow contour

검색결과 197건 처리시간 0.032초

차체 외부에서의 유동해석 (Flow Analysis on the Outside of Automotive Body)

  • 조재웅;한문식
    • 한국기계가공학회지
    • /
    • 제9권1호
    • /
    • pp.55-60
    • /
    • 2010
  • The air resistance about automotive body is studied by the flow analysis in this study. Maximum air flow velocity is shown with 28 to 30 m/s on the upper roof of automotive body. The air flow becomes most regular at automotive body model 3 but the model of 2 or 3 becomes irregular in comparison with the model 1. The maximum air resistance pressure is shown with 413 to 420 Pa at the front bumper of automotive body. The flow velocity at inlet or middle plane of automotive body is shown as the contour same with the model of 1, 2, or 3. But the velocity at outlet plane at model 1 is shown as the contour different with the model of 2 or 3.

CROSS FLOW EFFECTS ON THE FLAME HEIGHT OF AN INTERMEDIATE SCALE DIFFUSION FLAME

  • Kolb, Gilles;Torero, Jose L.;Most, Jean-Michel;Joulain, Pierre
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.169-177
    • /
    • 1997
  • An experimental study has been conducted at an intermediate scale to study the effect of a cross flow on a purely buoyant fire. Video taping of the flame and post processing of the images by means of a novel technique provide a contour of a mean flame for all cases studied. This flame contour allows the determination of a mean flame length and a mean flame height. The mean flame length and height are recorded as functions of the forced flow velocity. Three dimensional flow patterns are formed in the flame trailing edge affecting both the mean flame length and height. The three dimensional patterns are studied systematically as functions of the cross flow velocity to quantify the effect of confinement on the flame geometry.

  • PDF

4 방향 윤곽선 추적과 K-Means 알고리즘을 이용한 색조 도플러 초음파 영상에서 상환 동맥의 혈류 영역 추출 (Extraction of Blood Flow of Brachial Artery on Color Doppler Ultrasonography by Using 4-Directional Contour Tracking and K-Means Algorithm)

  • 박준성;김광백
    • 한국정보통신학회논문지
    • /
    • 제24권11호
    • /
    • pp.1411-1416
    • /
    • 2020
  • 본 논문에서는 색조 도플러 초음파 영상에서 K-Means 알고리즘을 적용하여 혈류 영역을 추출하는 방법을 제안한다. 제안된 방법에서는 ROI 영역을 추출하고, 추출된 ROI 영역에서 최대 명암도를 임계치로 설정한 이진화 기법을 적용하여 ROI 영역을 이진화한다. 이진화된 ROI 영역에서 4 방향 윤곽선 추적 기법을 적용하여 상완 동맥의 혈류 영역이 존재하는 사다리꼴 형태의 영역을 추출한다. 추출된 사다리꼴 형태의 영역에서 상완동맥의 혈류영역을 정확히 추출하기 위하여 K-Means 기반 양자화 기법을 적용한다. 실험에서 제안 된 방법은 현장 전문가의 검증을 거쳐 30건 중 28건 (93.3%)에서 혈류 영역을 성공적으로 추출하였다. 그리고 제안된 K-Means 기반 혈류 영역 추출 방법을 30개의 색조 도플러 초음파 영상에 적용하여 전문의가 제공한 상완동맥 혈류 영역과 제안된 방법을 비교 분석한 결과, 정확도가 평균적으로 94.27%로 나타났다.

자기공명심장영상의 좌심실 분할과 가시화 (Segmentation and Visualization of Left Ventricle in MR Cardiac Images)

  • 정성택;신일홍;권민정;박현욱
    • 대한의용생체공학회:의공학회지
    • /
    • 제23권2호
    • /
    • pp.101-107
    • /
    • 2002
  • 이 논문에서는 자기공명심장영상에서 내벽과 외벽의 추출을 위한 반자동 분할 알고리즘을 제안하였다. 이 알고리즘은 Generalized gradient vector flow snake와 초기 윤곽선 예측 과정을 기반으로 한다. 특히 이 알고리즘은 내벽과 외벽의 공간적인 특설을 이용하며 Cross profile correlation matching (CPCM)을 사용한다. 현재 공간에서의 이전 시간에 관계된 영상과 현재 시간에서의 공간에 관계된 영상을 사용하여 초기 윤곽선 예측을 더욱 효과적으로 수행하였다. Multislice와 multiphase의 Siemens와 GE. Medinus 자기공명심장영상을 사용하여 실험하였고 많은 영상들에 대해 충분히 만족할만한 결과를 얻었다. 그리고 분할한 결과로 quantitative analysis를 수행하였고 시각적으로 보여주었다. 개발된 소프트웨어는 Visual C++을 사용하여 windows 환경의 응용프로그램으로 개발되었다.

공압시험을 이용한 추력가변 노즐의 정상상태 성능 연구 (A study on steady state performance of variable thrust nozzle by cold-flow test)

  • 김중근;이지형;오종윤;장홍빈;김신회
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2007년도 제28회 춘계학술대회논문집
    • /
    • pp.289-294
    • /
    • 2007
  • 고체 추진기관은 높은 비추력, 운용 안전성, 설계/제작하기가 쉽다는 장점이 있으나 추력 크기를 조절할 수 없다. 본 논문에서는 고체 추진기관의 추력을 조절할 수 있는 핀틀 노즐성능에 대한 연구로 Needle형 핀틀을 사용하여 수행한 공압 시험결과와 수치해석 결과를 수록하였다. 연구의 결과, 핀틀 노즐의 추력성능과 추력변화 범위는 핀틀 팁의 형상과 노즐의 Contour형상에 크게 의존하기 때문에 핀틀 팁의 형상과 노즐의 Contour형상은 중요한 설계 변수임을 알 수 있었고 특히, 시험에 적용된 Needle형 핀틀 노즐의 성능은 기존 노즐 대비 약 13%의 추력상승이 예측됨을 알 수 있었다.

  • PDF

Classification of White Blood Cell Using Adaptive Active Contour

  • Theerapattanakul, J.;Plodpai, J.;Mooyen, S.;Pintavirooj, C.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.1889-1891
    • /
    • 2004
  • The differential white blood cell count plays an important role in the diagnosis of different diseases. It is a tedious task to count these classes of cell manually. An automatic counter using computer vision helps to perform this medical test rapidly and accurately. Most commercial-available automatic white blood cell analysis composed mainly 3 steps including segmentation, feature extraction and classification. In this paper we concentrate on the first step in automatic white-blood-cell analysis by proposing a segmentation scheme that utilizes a benefit of active contour. Specifically, the binary image is obtained by thresolding of the input blood smear image. The initial shape of active is then placed roughly inside the white blood cell and allowed to grow to fit the shape of individual white blood cell. The white blood cell is then separated using the extracted contour. The force that drives the active contour is the combination of gradient vector flow force and balloon force. Our purposed technique can handle very promising to separate the remaining red blood cells.

  • PDF

A LOCALIZED GLOBAL DEFORMATION MODEL TO TRACK MYOCARDIAL MOTION USING ECHOCARDIOGRAPHY

  • Ahn, Chi Young
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • 제18권2호
    • /
    • pp.181-192
    • /
    • 2014
  • In this paper, we propose a robust real-time myocardial border tracking algorithm for echocardiography. Commonly, after an initial contour of LV border is traced at one or two frame from the entire cardiac cycle, LV contour tracking is performed over the remaining frames. Among a variety of tracking techniques, optical flow method is the most widely used for motion estimation of moving objects. However, when echocardiography data is heavily corrupted in some local regions, the errors bring the tracking point out of the endocardial border, resulting in distorted LV contours. This shape distortion often occurs in practice since the data acquisition is affected by ultrasound artifacts, dropout or shadowing phenomena of cardiac walls. The proposed method deals with this shape distortion problem and reflects the motion realistic LV shape by applying global deformation modeled as affine transform partitively to the contour. We partition the tracking points on the contour into a few groups and determine each affine transform governing the motion of the partitioned contour points. To compute the coefficients of each affine transform, we use the least squares method with equality constraints that are given by the relationship between the coefficients and a few contour points showing good tracking results. Many real experiments show that the proposed method supports better performance than existing methods.

Constitutive equation and damping function for entangled polymers

  • Osaki, Kunihiro
    • Korea-Australia Rheology Journal
    • /
    • 제11권4호
    • /
    • pp.287-291
    • /
    • 1999
  • The tube model theory of entangled polymer presumes that the polymer chain holds its equilibrium contour length under certain conditions of flow; at times longer than a certain characteristic time, ${\tau}_k$, in the stress relaxation process following any flow history; in steady flow of rates smaller than ${{\tau}_k}^{-1}$; etc. Rheological phenomena associated with this presumption are discussed.

  • PDF

Digital Endoscopic Image Segmentation using Deformable Models

  • Yoon, Sung-Won;Kim, Jeong-Hoon;Lee, Myoung-Ho
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2002년도 ICCAS
    • /
    • pp.57.4-57
    • /
    • 2002
  • $\textbullet$ Image segmentation is an essential technique of image analysis. In spite of the traditional issues in contour initialization and boundary concavities, active contour models(snakes) are popular and known as successful methods for segmentation. $\textbullet$ We could find in experiment that snake using Gaussian External Force is fast in time but low in accuracy and snake using Gradient Vector Flow by Chenyang Xu and Jerry L. Prince is high in accuracy but slow in time. $\textbullet$ In this paper, we presented a new active contour model, GGF snake, for segmentation of endoscopic image. Proposed GGF snake made up for the defects of the traditional snakes in contour initialization and boundary...

  • PDF

Kriging 기법을 이용한 지하수위 분포 추정 (Application of kriging approach for estimation of water table elevation)

  • 박준경;박영진;위용곤;이상호;홍창수;추석연
    • 한국터널지하공간학회 논문집
    • /
    • 제4권3호
    • /
    • pp.217-227
    • /
    • 2002
  • ${\bigcirc}{\bigcirc}$ 터널 구간의 지하수유동분석을 위해 지구통계학적 기법을 적용하였다. 이 지역의 표고와 관정 및 터널시추공에서의 지하수위의 선형회귀분석결과 상관성이 매우 큰 것으로 나타났다. 보통크리깅 및 공크리깅을 이용하여 작성된 지하수위 등고선도는 표고등고선도를 기준으로 비교해보면 공크리깅에 의한 것이 정밀성이 더 큰 것으로 나타났다. 보통크리깅과 공크리깅에 의해 작성된 지하수위 등고선도에서는 지하수 유동상태를 검토해 보면, 북서쪽의 산악지형에서 계곡쪽으로, 봉우리 일대에서 외곽쪽으로 각각 유동하는 것으로 나타났다. 본 연구를 통해 터널굴착 예정지역의 정확한 분석이나 관측자료의 평가없이 사용하던 지하수위 분포를 정량적으로 설계에 반영할 수 있었으며, 공간상에 분포하는 자료측정의 제한성과 경제적인 이유로 충분한 자료를 확보할 수 없는 현실에 비추어 볼 때 지구통계학은 미지의 구간에 대해 보다 정량적인 자료를 제공할 수 있음을 보여주었다.

  • PDF