• Title/Summary/Keyword: Flow channel design

Search Result 516, Processing Time 0.028 seconds

Computational Fluid Dynamics Study on Uniform Cooling of Polymer Electrolyte Membrane Fuel Cells by Parallel Multi-pass Serpentine Flow Fields (병렬 사형유로를 채택한 냉각판을 통한 고분자 전해질 연료전지의 균일 냉각에 대한 전산유체역학 해석 연구)

  • Yu, Seung-Ho;Baek, Seung-Man;Nam, Jin-Hyun;Kim, Charn-Jung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.10
    • /
    • pp.885-891
    • /
    • 2010
  • Thermal management is important for enhancing the performance and durability of polymer electrolyte membrane fuel cells (PEMFCs) and is taken into account in the design of PEMFCs. In general, cooling pates with circulating liquid coolant (water) are inserted between several unit cells to exhaust the reaction heat from PEMFCs. In this study, computational fluid dynamics (CFD) simulations were performed to characterize the uniform cooling performance of parallel multipass serpentine flow fields (MPSFFs) that were used as coolant flow channels in PEMFCs. The cooling performances of conventional serpentine and parallel flow fields were also evaluated for the purpose of comparison. The CFD results showed that the use of parallel MPSFFs can help reduce the temperature nonuniformity, and thus, can favorably enhance the performance and durability of PEMFCs.

An analysis on stability of riprap considering hydraulic characteristics of flow around joint revetment (연결호안 주변 흐름의 수리적 특성을 고려한 사석호안의 안정성 분석)

  • Kim, Sooyoung;Kim, Hyung-Jun;Yoon, Kwang Seok
    • Journal of Korea Water Resources Association
    • /
    • v.49 no.12
    • /
    • pp.1035-1044
    • /
    • 2016
  • In joint portions of the levee and the barrier, complex 3-dimensional flow was generated and collapse of revetment occurred frequently. For these reasons, it is necessary to install the joint revetment with greater stability as compared with the general revetment at the joint portions. However, design criteria for joint revetment was not presented in River Design Criteria (KWRA, 2009). Therefore it is necessary to research for engineering design of the joint revetment. In this study, hydraulic experiments were performed under various flow conditions in order to realize the collapse conditions of riprap and carried out in 20.0 m straight open channel with one side levee and the width was 4.0 m. The diameter of riprap covered around joint revetment was 0.03 m and the inlet discharges were $0.5{\sim}0.8m^3/s$. The numerical simulations were performed under same conditions with experiment. as results of this numerical simulations, the influence range was confirmed from the distribution of flow characteristics and shear stress. As a result, the riprap diameter of the joint revetment was calculated from 4.1 to 6.9 times greater than that of general revetment. As the inlet discharge was large, the range of vulnerable area was developed long in the downstream direction despite of same withdrawal velocity of riprap. Through this study, the methods of calculating the riprap diameter and influence range were proposed according to hydraulic characteristics of flow around joint revetment. At a later study, if additional experiments about effect of flood plane and various types of barrier is applied, it is expected that rational design method with stability of joint revetment can be proposed.

An Experimental Study on the Swimming Performance of Pale Chub(Zacco platypus) (피라미의 유영특성에 관한 실험적 연구)

  • Park, Seong-Yong;Kim, Seo-Jun;Lee, Seung-Hwi;Yoon, Byung-Man
    • Journal of Korea Water Resources Association
    • /
    • v.41 no.4
    • /
    • pp.423-432
    • /
    • 2008
  • The local migration or movement behavior of fishes in streams are related to feeding, spawning, growing, dispersing, and refuging. The pale chub (Zacco platypus) is a dominant species that migrates locally and inhabits in river and stream in Korea. However, dams, weirs, culverts and other regulatory structures are physical barriers that limit fish movement and fragment habits and populations. If main stream and off-channel habitats are connected with culverts, they would restrict the small fish as pale chub movement due to the high flow velocities and low depths. But in Korea, there is no experimental study to evaluate the swimming performance of species in Korea. Therefore, it is difficult to proposed that design guidelines for pass fishes through culverts. The purpose of this experimental study is to evaluate the swimming performance of pale chubs. A series of swimming performance test has been used in both of the fixed velocity and the incremental velocity methods in an experimental flume. As a result, the critical swimming speed for pale chub(body length 8.9 cm) was found to be about 0.7 m/s. Therefore, the flow velocity for culvert design in the low flow condition should not be exceed the its swimming ability, especially 0.7 m/s for pale chubs(body length 8.9 cm). And the minimum depth for culvert design in the low flow condition should not be lower than the fish body height add a dorsal fin height.

Estimation of Soil Loss into Sap-Gyo Reservoir Watershed using GIS and RUSLE (GIS와 RUSLE 기법을 이용한 삽교호유역의 토사 유실량 산정)

  • Kim, Man-Sik;Jung, Seung-Kwon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.3 no.4
    • /
    • pp.19-27
    • /
    • 2002
  • Prediction of exact soil loss yield has as important engineering meaning as prediction of exact flow measurement in a stream. The quantity of soil loss in a stream should be considered in planning and management of water resources and water quality such as design and maintenace of hydraulic structures : dams, weirs and seawalls, channel improvement, channel stabilization, flood control, design and operation of reservoirs and design of harbors. In this study, the soil loss of Sap-gyo reservoir watershed is simulated and estimated by RUSLE model which is generally used in the estimation of soil loss. The parameters of RUSLE model are selected and estimated using slope map, landuse map and soil map by GIS. These parameters are applied to RUSLE's estimating program. And soil loss under probability rainfall in different frequencies are estimated by recent 30 years of rainfall data of Sap-gyo reservoir watershed.

  • PDF

NUMERICAL STUDY OF TURBINE BLADE COOLING TECHNIQUES (터빈 블레이드 냉각시스템에 관한 수치해석적 연구)

  • Kim, K.Y.;Lee, K.D.;Moon, M.A.;Heo, M.W.;Kim, H.M.;Kim, J.H.;Husain, A.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2010.05a
    • /
    • pp.530-533
    • /
    • 2010
  • This paper presents numerical analysis and design optimization of various turbine blade cooling techniques with three-dimensional Reynolds-averaged Navier-Stokes(RANS) analysis. The fluid flow and heat transfer have been performed using ANSYS-CFX 11.0. A fan-shaped hole for film-cooling has been carried out to improve film-cooling effectiveness with the radial basis neural network method. The injection angle of hole, lateral expansion angle of hole and ratio of length-to-diameter of the hole are chosen as design variables and spatially averaged film-cooling effectiveness is considered as an objective function which is to be maximized. The impingement jet cooling has been performed to investigate heat transfer characteristic with geometry variables. Distance between jet nozzle exit and impingement plate, inclination of nozzle and aspect ratio of nozzle hole are considered as geometry variables. The area averaged Nusselt number is evaluated each geometry variables. A rotating rectangular channel with staggered array pin-fins has been investigated to increase heat transfer performance ad to decrease friction loss using KRG modeling. Two non-dimensional variables, the ratio of the eight diameter of the pin-fins and ratio of the spacing between the pin-fins to diameter of the pin-fins selected as design variables. A rotating rectangular channel with staggered dimples on opposite walls are formulated numerically to enhance heat transfer performance. The ratio of the dimple depth and dimple diameter are selected as geometry variables.

  • PDF

A Study on Flow Distribution to Flocculation Basins Using DOE and RSA (실험계획법과 반응표면분석법을 적용한 응집지로의 유량분배에 관한 연구)

  • Kim, Seong-Jae;Kyung, Gyu-Sun;Jeong, Heui-Jung;Kim, Hyeong-Seop;Yang, Sa-Sun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.12
    • /
    • pp.918-928
    • /
    • 2013
  • The inequitable flow distribution to flocculation basins is an important problem faced in many water treatment plants. This is caused by the structure of a distribution channel, the height differences of outlet weirs etc. But, a modified approach for the structures has no effectiveness to achieve flow equality. The aim of this study is to reduce the inequality by adopting optimized inlet valve opening (%) of the flocculation basins using DOE (Design of Experiments) and RSA (Response Surface Analysis). The inlet valve openings (%) and inflow distributions (%) of 6 paralleled basins were set as factors (X) and characteristics(Y) respectively. 2 level factorial experiments and RSA were conducted for optimization and regression analysis (Y = f(X) + Const.). Adopting the optimized inlet valve opening (%) at field, standard deviation of flow distribution (%) and effluent turbidity was declined from 3.80% to 0.42% and from 0.29 NTU to 0.03 NTU respectively.

Results of Cold Flow Test and Design of Injectors for Oxidizer-rich Preburner (산화제 과잉 예연소기용 분사기 설계 및 수류 시험 결과)

  • So, YoonSeok;Woo, SeongPil;Lee, Kwang-Jin;Yu, ByungIl;Kim, Jinhyung;Cho, Hwangrae;Bang, Jeongsuk;Han, YeongMin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.1
    • /
    • pp.52-57
    • /
    • 2018
  • This paper presents the design and cold flow test results of oxidizer-rich preburner injectors for a 9 tonf-class staged combustion engine cycle. Three types of coaxial swirl injectors were designed, and 12 injectors were designed for each type. The diameters of the fuel tangential holes are identical. The diameters of the oxidizer tangential holes were varied to investigate the influence of combustion in the oxidizer-rich preburner according to the momentum ratio of the gas oxidizer generated from combustion in the injector chamber and liquid oxidizer through the cooling channel. It will be verified through a powerpack and combustion test using an oxidizer-rich preburner. In the cold flow test, the fuel flow rate and oxidizer tangential hole flow rate reached the target value based on the designed differential pressure.

The stable design of radiant heat inside PCB circuit board device (PCB회로 보드장치내의 안정적 방열설계를 위한 연구)

  • Won, Jong-Wun;Lee, Jong-Hwi
    • Journal of the Korea Safety Management & Science
    • /
    • v.15 no.2
    • /
    • pp.129-134
    • /
    • 2013
  • In this study, the heat flow analysis compatible commercial code CFX 11 was used to develop the structure inside PCB circuit board devices, which could stable radiant heat as well as the cooling device within it. In case of modifying the arrangement of electronic parts on the PCB inside the multi channel temperature measurement board devices, radiant heat effects did not show a rising tendency, whereas the overall temperature went down in case of installing the vents in the outer case of PCB circuit board devices. In terms of installation location, it was the most appropriate to install it on the electronic parts with no heat. Besides, in case of mounting the fan as a cooling device by considering various user environments for multi channel temperature measurement board devices, the radiant heat effects were shown higher than in case of installing the vents, and the middle sections were the most appropriate to its installation location. In case of changing the wind quantity of the fan from its selected installation location, the best radiant heat effects were shown at high speed as expected.

Study on Development of High Performance Evaporator for Automotive Air Conditioner (자동차 공조용 증발기의 고성능화에 관한 연구)

  • Kang, J.K.;Kim, K.H.;Park, T.Y.;Kim, J.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.1
    • /
    • pp.73-80
    • /
    • 1995
  • The object of the present study is to develop a high performance evaporator for automotive air conditioner. The experiment has been conducted on evaporative heat transfer coefficient inside a plate type heat exchanger with a sharp 180-degree turn flow. The test plates have different formed surface, cross-ribbed channel and elliptical-ribbed channel. Also experimental study has been performed to determine optimal design in elliptical-ribbed plate heat exchanger with different turn clearance. In addition to the above experiments, refrigerant behavior and surface temperature distribution in the plate heat exchanger were observed using color thermoviewer(infrared thermometer). In this experiment, working fluid was used R-12 and test conditions were as follows : (1) saturation pressure of $2.116kg/cm^2$, (2) mass fluxes of 40 to $70kg/m^2s$, (3) heat fluxes of 4,500 to $7,300W/m^2$, (4) inlet quality of 0.1 to 0.7. The results indicated that the evaporative heat transfer coefficient of an elliptical-ribbed plate heat exchanger was higher than that of cross-ribbed plate heat exchanger. Also optimal turn clearance in an elliptical-ribbed plate heat exchanger was determined.

  • PDF

Thermal Analysis of Water Cooled ISG Based on a Thermal Equivalent Circuit Network

  • Kim, Kyu-Seob;Lee, Byeong-Hwa;Jung, Jae-Woo;Hong, Jung-Pyo
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.3
    • /
    • pp.893-898
    • /
    • 2014
  • Recently, the interior permanent synchronous motor (IPMSM) has been applied to an integrated starter and generator (ISG) for hybrid electric vehicles. In the design of such a motor, thermal analysis is necessary to maximize the power density because the loss is proportional to the power of a motor. Therefore, a cooling device as a heat sink is required internally. Generally, a cooling system designed with a water jacket structure is widely used for electric motors because it has advantages of simple structure and cooling effectiveness. An effective approach to analyze an electric machine with a water jacket is a thermal equivalent network. This network is composed of thermal resistance, a heat source, and thermal capacitance that consider the conduction, convection, and radiation. In particular, modeling of the cooling channel in a network is challenging owing to the flow of the coolant. In this paper, temperature prediction using a thermal equivalent network is performed in an ISG that has a water cooled system. Then, an experiment is conducted to verify the thermal equivalent network.