• Title/Summary/Keyword: Flow channel design

Search Result 517, Processing Time 0.026 seconds

Optimal Design on a Channel of Rectangular Suction Sludge Collector and the Flow Characteristics of Wastewater (장방형 흡입식 슬러지 수집기에서 수로의 최적설계 및 폐수 유동특성)

  • Yong, Jung-Kwon;Choi, Chung-Ryul;Kim, Chang-Nyung
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1034-1039
    • /
    • 2008
  • Recently, the sludge suction collector is preferred rather than the scraper type sludge collector due to enhancement of the clarifier efficiency. The sludge suction collector is usually operated by the user's experience without any scientific and technical consideration. There are many factors that should be considered for higher quality of discharged water and stabilized flow in the rectangular sludge suction collector but, the optimal design on the inflow channel and orifices connecting with the inflow channel is needed for similar flow rates at the orifices. The 4 cases of channel geometry are considered and mass flow rates of each case at the orifices are evaluated using Computational Fluid Dynamics applied VOF(Volume of Fraction) model.

  • PDF

Performance Test for a Horizontal Regenerative Evaporative Cooler (수평형 재생증발식 냉방기의 성능시험)

  • Song, Gwi-Eun;Lee, Dae-Young
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.621-626
    • /
    • 2006
  • Regenerative evaporative cooling is known as an environment-friendly and energy efficient cooling method. A regenerative evaporative cooler (REC) consisting of dry and wet channels is able to cool down the air stream below the inlet wet-bulb temperature. In the regenerative evaporative cooler, the cooling effect is achieved by redirecting a portion of the air flown out of the dry channel into the wet channel and spraying water onto the redirected air. In this study, a horizontal regenerative cooler is considered. In the horizontal regenerative cooler, the flow direction of evaporating water has a right angle to the flow direction of supply air. This difference was investigated with visualization technique and simplified 2-module performance test was done in a thermo-environment chamber. Optimum design configuration is changed due to the wet channel which are easily fully covered with evaporating water and block the air flow inside the channel. Applying the optimized fin configuration design with the highly wetting surface treatment, a regenerative evaporative cooler was fabricated and tested to Identify the cooling performance improvement and operation characteristics. From the experimental results at the intake condition of $32^{\circ}C$ and 50% RH, the supply temperature was measured to be around $23.4^{\circ}C$. The cooling effectiveness based on the inlet dewpoint temperature was evaluated 73% which is almost close to the design expectation.

  • PDF

The Flow Analysis of Virtual Channel depending upon the change of two ingates

  • Kim, Nam-Hyeong;Kim, Gyeong-Bo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.1636-1640
    • /
    • 2006
  • SMAC method, one of the computational fluid dynamics techniques, is modified from the original MAC method for the time-dependent variation of flow analysis. The Navier-Stokes equations for incompressible time-dependent viscous flow are applied, and also marker particles that present the visualization of flow analysis are used. In this study SMAC technique is used to analyze the flow behavior in the water-filling of virtual channel. Then by changes of diameter of two ingates, the change of velocity and discharge when two ingates are filled the water to virtual channel are simulated. As a result, water-filling flow pattern in the virtual channel is simulated very well. Therefore, this numerical simulation will also be applied for the design of structures as open flume and porous breakwater.

  • PDF

Optimization of Angled Ribs for Heat Transfer Enhancement in a Square Channel with Bleed Flow (유출유동을 가진 정사각유로 내 열전달 향상을 위한 경사진 요철 최적설계)

  • Lee, Hyun;Kim, Kyung-Min;Lee, Dong-Hyun;Cho, Hyung-Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.4
    • /
    • pp.300-306
    • /
    • 2008
  • In the present study, the second order response surface method (RSM) is carried out to get optimum thermal design for enhancing heat transfer in a square channel with bleed flow. The RSM is used as an optimization technique. To calculate the heat transfer, RNG k-epsilon model and enhanced wall function are used. To design optimum rib turbulators, two design variables such as attack angle of rib $({\alpha})$ and rib pitch-to-rib height ratio (p/e) are optimized. In these analyses, the channel inlet Reynolds number was fixed at 10,000 in both non-bleeding and bleeding cases. The response surfaces of two design variables are constructed in cases with and without bleed flow. As a result, the optimum (or highest) heat transfer values are almost the same in ranges of two cases with and without bleed flow. However, the friction losses in the case with bleed flow are lower than those without bleed flow.

Improving Flow Distribution in a Suction Channel for a Highly Efficient Centrifugal Compressor

  • Yagi, Manabu;Shibata, Takanori;Kobayashi, Hiromi;Tanaka, Masanori;Nishida, Hideo
    • International Journal of Fluid Machinery and Systems
    • /
    • v.5 no.3
    • /
    • pp.100-108
    • /
    • 2012
  • Design parameters for suction channels of process centrifugal compressors were investigated, and an optimization method to enhance stage efficiency by using the new design parameters was proposed. From results of computational fluid dynamics, the passage sectional area ratios $A_c/A_e$, $A_e/A_s$ and $A_c/A_s$ were found to be the dominant parameters for the pressure loss and circumferential flow distortion, where $A_c$, $A_e$ and $A_s$ are passage sectional areas for the casing upstream side, casing entrance and impeller eye, respectively. The Base suction channel was optimized using the new design parameters, and the Base and Optimized types were tested. Test results showed that the Optimized suction channel achieved 3.8% higher stage efficiency than the Base suction channel while maintaining the same operating range.

Optimization of Cathode Flow Field Design for a PEMFC with Six Sigma Technique (Six sigma 기법을 이용한 PEMFC Cathode 유로설계 최적화)

  • Kim, Sun-Hoe
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.20 no.6
    • /
    • pp.492-498
    • /
    • 2009
  • Six sigma methode was applied for optimization of flow field design of a proton exchange membrane fuel cell (PEMFC). The optimization between number of channel and channel/rib width was suggested in this paper with six sigma method. With the help of six sigma design of experiment (DOE) the number of experiments may be reduced dramatically. The fuel cell channel design optimization with results of these experiments with a 100 $cm^2$ serpentine flow field indicates a optimization data for a given constant operating conditions.

Optimal Design of Orifice typed Distribution Channel using Step Method Program (Step method 프로그램을 이용한 orifice 분배수로의 최적 설계에 관한 연구)

  • Park, No-Suk;Park, Sangcheol;Kim, Sung-soo;Lee, Seonjoo;Jeong, Nam-Jeong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.5
    • /
    • pp.691-700
    • /
    • 2006
  • This study conducted to optimize the design and operation of orifice typed distribution channels which were generally constructed to link the rapid mixing process and flocculation/sedimentation basin. To accomplish the goal of this study, programming step method using FORTRAN 90, was applied it to simulate the performance of existing distribution channel in the selected S DWTP (Drinking Water Treatment Plant). The proposed step method program was validated in terms of the feasibility with comparison between the measurement and prediction value in each orifice. From the evaluation results of the current conditions with the design and operation, it was revealed that the existing gradient of the tapered channel is not appropriate. Also, we suggested that in the case of the inlet width being 3.5m, reducing the downstream width by about 0.5m would make more equitable distribution flow in the channel. Consequently, dealing with various conditions of the design and operation with distribution channel, we could conclude that for the parallel typed channel, as the width is wider and the diameter of orifice is smaller, the more equitable distribution occur. In addition, the inlet flowrate and the number of orifice can affect the flow velocity in the channel.

Design of sinusoidal shape channel PCHEs for supercritical LNG based on CFD simulation (CFD 시뮬레이션 기반 초임계 LNG용 사인함수 PCHE 설계)

  • Fan, Jinxing;Yeom, Eunseop
    • Journal of the Korean Society of Visualization
    • /
    • v.19 no.3
    • /
    • pp.69-76
    • /
    • 2021
  • Printed circuit heat exchanger (PCHE) is a compact heat exchanger with good heat transfer performance, high structure integrity, and reliability over a wide range of temperatures and pressures. Instead of the traditional zigzag and straight shape channel, the sinusoidal shape channel was adopted in this study to investigate the relation of thermal-hydraulic performance and waviness factors (period and amplitude). The local flow characteristics and the heat flux distribution were compared to verify the effects of period and amplitude on heat transfer performance. As the period of channel becomes shorter, the rapid change of the flow direction can produce high flow separation around the corner leading to the disturbance of the boundary layer opposite wall. The nonuniform distribution of flow velocity appeared around the corner positions can promote fluid mixing and lead to higher thermal performance. An evaluation index was used to compare the comprehensive performance of PCHE considering the Nusselt number and Fanning factor. Based on the simulation results, the optimal design parameters of PCHE channel shape were found that the channel with an equivalent bending angle of 15° offers the highest heat flux capacity.

Flow on Grooved Roof Surface

  • Yoon, Tae-Hoon;Hwang, Chang-Ho
    • Korean Journal of Hydrosciences
    • /
    • v.1
    • /
    • pp.15-25
    • /
    • 1990
  • Spatially varied unsteady flow in a groave-like channel of a sloping roof is analyzed by numerical solution of Saint Venant equations. Depth variations are discussed with different slopes and bed roughness of the channel. Time to equilibrium is found to be inversely proportional to the kinematic flow number. The design of roof drainage system by different schemes is included.

  • PDF

3 Dimensional Flow Analysis of Small Regenerative Pump (소형 재생펌프의 3차원 성능 해석에 관한 연구)

  • Kang, Shin-Hyoung;Lim, Hyung-Soo;Ryu, Su-Hyun;Shim, Chang-Yeul
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.12
    • /
    • pp.1600-1607
    • /
    • 2004
  • Performance of a regenerative pump is evaluated based on the calculated through flows using the CFX-TASCflow code. Flow calculations are performed in one vane to vane space of the impeller and side channel. The flow is very complex three dimensional with a strong radial vortex due to centrifugal force and an axial vortex due to re-circulating flow between the impeller and the side channel. Momentum exchange on the plane between the impeller and the side channel are evaluated to estimate design parameters and viscous losses in the pump. The present study contributes to showing the capability of flow simulation of complex flow in the regenerative pump by comparing the calculated performance with the measured value.