• Title/Summary/Keyword: Flow Resonance

Search Result 476, Processing Time 0.021 seconds

MRI with Continuously Flowing Laser-Polarized $^3He$

  • Lee, Hyeong-Ju;Kim, Chul;Kim, Byung-Soo;Kim, Do-Hun;Lee, Hee-Cheon
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.7 no.1
    • /
    • pp.62-67
    • /
    • 2003
  • MRI of laser-polarized $^{129}$ Xe under continuous flow conditions has recently been used for imaging of porous materials, however, any attempts at using a continuously circulating flow of laser-polarized $^3$He have not been made until now, presumably due to its extremely long spin exchange time (5-10 hrs). Since the inherent NMR sensitivity of $^3$He is 80 times greater than that of $^{129}$ Xe when considering the natural abundance, $^3$He can be expected to be a better nucleus for imaging than $^{129}$ Xe even under continuous flow conditions. In this report, the first MRI with continuously flowing laser-polarized $^3$He is shown for a phantom of Teflon tubing, demonstrating the feasibility of $^3$He imaging under continuous flow.

  • PDF

An Investigation of the Sample Rotation Effects on Suppression of Convective Flows in PGSE Diffusion NMR Experiments

  • Kim, Minkyoung;Chung, Kee-Choo
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.20 no.2
    • /
    • pp.61-65
    • /
    • 2016
  • Undesirable convective flow in an NMR tube inhibits the accurate measurement of diffusion coefficients by NMR spectroscopy. To minimize the convection effects, various methods have been suggested, and it has been known that the use of sample rotation can be useful. However, it has not been clearly examined that the convection suppressing effect of the sample rotation under the different spinning speeds. In this study, the relation between convective flow and the sample rotation was investigated using PGSE NMR diffusion experiments to reveal the feasibility for controlling the convective flow in an NMR tube by sample rotation itself. The viscosity effect was also examined using solvents with four different viscosities, acetone-$d_6$ chloroform-d, pyridine-$d_5$, and $D_2O$. The sample rotation showed apparent convection suppressing effects at all temperature range for the low viscosity solvents, acetone-$d_6$ and chloroform-d, even at the faster than 5 Hz spinning rate. The similar patterns were also observed for pyridine-$d_5$ and $D_2O$, which have higher viscosity. This effect was observed even at high temperatures where convective flow arises conspicuously.

On the silicon nitride film formation and characteristic study by chemical vapor deposition method using electron cyclotron resonance plasma (전자 싸이클로트론 공명 플라즈마 화학 증착법에 의한 실리콘 질화막 형성 및 특성 연구)

  • 김용진;김정형;송선규;장홍영
    • Journal of the Korean institute of surface engineering
    • /
    • v.25 no.6
    • /
    • pp.287-292
    • /
    • 1992
  • Silicon nitride thin film (SiNx) was deposited onto the 3inch silicon wafer using an electron cyclotron resonance (ECR) plasma apparatus. The thin films which were deposited by changing the SiH4N2 gas flow rate ratio at 1.5mTorr without substrate heating were analyzed through the x-ray photo spectroscopy (XPS) and ellipsometer measurements, etc. Silicon nitride thin films prepared by the electron cyclotron resonance plasma chemical vapor deposition method at low substrate temperature (<10$0^{\circ}C$) exhibited excellent physical and electrical properties. The very uniform and good quality silicon nitride thin films were obtained. The characteristics of electron cyclotron resonance plasma were inferred from the analyzed results of the deposited films.

  • PDF

Fluxon resonance steps in the $Bi_2Sr_2CaCu_2O_{8+x}$ single crystals

  • Bae, Myung-Ho;Lee, Hu-Jong
    • Progress in Superconductivity
    • /
    • v.8 no.2
    • /
    • pp.138-142
    • /
    • 2007
  • We observed discrete fluxon-flow resonance steps in high magnetic fields in a stack of Josephson junctions with lateral size of $1.5{\times}17{\mu}m^2$. The measurement sample was prepared by sandwiching a stack of $Bi_2Sr_2CaCu_2O_{8+x}$ intrinsic Josephson junctions between two Au electrodes by using the double-side-cleaving technique. This technique allowed us to isolate the intrinsic Josephson junction structures from the inductive interference of the basal stack. The resonance steps observed are in good agreement with the collective Josephson fluxon dynamics that are in resonance with the plasma oscillation modes inside the stacked Josephson junctions.

  • PDF

Effect of Internal Fluid Resonance on the Performance of a Floating OWC Device

  • Cho, Il Hyoung
    • Journal of Ocean Engineering and Technology
    • /
    • v.35 no.3
    • /
    • pp.216-228
    • /
    • 2021
  • In the present study, the performance of a floating oscillating water column (OWC) device has been studied in regular waves. The OWC model has the shape of a hollow cylinder. The linear potential theory is assumed, and a matched eigenfunction expansion method(MEEM) is applied for solving the diffraction and radiation problems. The radiation problem involves the radiation of waves by the heaving motion of a floating OWC device and the oscillating pressure in the air chamber. The characteristics of the exciting forces, hydrodynamic forces, flow rate, air pressure in the chamber, and heave motion response are investigated with various system parameters, such as the inner radius, draft of an OWC, and turbine constant. The efficiency of a floating OWC device is estimated in connection with the extracted wave power and capture width. Specifically, the piston-mode resonance in an internal fluid region plays an important role in the performance of a floating OWC device, along with the heave motion resonance. The developed prediction tool will help determine the various design parameters affecting the performance of a floating OWC device in waves.

A Comparison of Surge Behaviors in Multi-Stage and Single-Stage Axial Flow Compressors

  • Yamaguchi, Nobuyuki
    • International Journal of Fluid Machinery and Systems
    • /
    • v.9 no.4
    • /
    • pp.338-353
    • /
    • 2016
  • Information on the surge behaviors and stall stagnation boundaries for a nine-stage axial flow compressor are summarized on the basis of analytical data in comparison with those for a single-stage one, with attention to the pressure ratio effect. The general trends of the surge loop behaviors of the pressure-mass flow are similar for both compressors including the fact that the subharmonic surges tend to appear very near the stall stagnation boundaries. With respect to the nine-stage compressor, however, the mild loops in the subharmonic surges tend to be very small in size relative to the deep loops, and at the same time, insufficient surge recovery phenomenon, which is a kind of subharmonic surge, appears also far from the stagnation boundary for relatively short delivery flow-paths. The latter is found to be a rear-stage surge caused by unstalling and re-stalling of the rear stages with the front-stages kept in stall in the stalled condition of the whole compressor, which situation is caused by stage-wise mismatching in the bottom pressure levels of the in-stall multi-stage compressor. The fundamental information on the stall stagnation boundaries is given by a group of normalized geometrical parameters including relative delivery flow-path length, relative suction flow-path length, and sectional area-pressure ratio, and by another group of normalized frequency parameters including relative surge frequencies, modified reduced resonance frequencies, and modified reduced surge frequencies. Respective groups of the normalized parameters show very similar tendency of behaviors for the nine-stage compressor and the single-stage compressor. The modified reduced resonance frequency could be the more reasonable parameter suggesting the flow-induced oscillation nature of the surge phenomena. It could give the stall stagnation boundary in a more unified manner than the Greitzer's B parameter.

Early Spontaneous Recanalization of Sigmoid Sinus Thrombosis Following a Closed Head Injury in a Pediatric Patient : A Case Report and Review of Literature

  • Yun, Jung-Ho;Ko, Jung Ho;Lee, Mee Jeong
    • Journal of Korean Neurosurgical Society
    • /
    • v.58 no.2
    • /
    • pp.150-154
    • /
    • 2015
  • Cerebral venous sinus thrombosis (CVST) following a closed head injury in pediatric patients is a rare condition, and an early spontaneous recanalization of this condition is extremely rare. A 10-year-old boy was admitted with a mild, intermittent headache and nausea five days after a bicycle accident. The brain computed tomography showed an epidural hematoma at the right occipital area with pneumocephalus due to a fracture of the occipital skull bone. The brain magnetic resonance imaging and the magnetic resonance venography demonstrated a flow signal loss from the right sigmoid sinus to the right jugular vein. The diagnosis was sigmoid sinus thrombosis, so close observations were selected as a treatment for the patient because of his gradually improving symptoms; however, he complained of vomiting 14 days the after conservative treatment. The patient was readmitted for a further examination of his symptoms. The laboratory and the gastroenterological examinations were normal. Due to concern regarding the worsening of the sigmoid sinus thrombosis, the brain magnetic resonance venography was rechecked and it revealed the recanalization of the venous flow in the sigmoid sinus and in the jugular vein.

Passive suppression of helicopter ground resonance instability by means of a strongly nonlinear absorber

  • Bergeot, Baptiste;Bellizzi, Sergio;Cochelin, Bruno
    • Advances in aircraft and spacecraft science
    • /
    • v.3 no.3
    • /
    • pp.271-298
    • /
    • 2016
  • In this paper, we study a problem of passive suppression of helicopter Ground Resonance (GR) using a single degree freedom Nonlinear Energy Sink (NES), GR is a dynamic instability involving the coupling of the blades motion in the rotational plane (i.e. the lag motion) and the helicopter fuselage motion. A reduced linear system reproducing GR instability is used. It is obtained using successively Coleman transformation and binormal transformation. The analysis of the steadystate responses of this model is performed when a NES is attached on the helicopter fuselage. The NES involves an essential cubic restoring force and a linear damping force. The analysis is achieved applying complexification-averaging method. The resulting slow-flow model is finally analyzed using multiple scale approach. Four steady-state responses corresponding to complete suppression, partial suppression through strongly modulated response, partial suppression through periodic response and no suppression of the GR are highlighted. An algorithm based on simple criterions is developed to predict these steady-state response regimes. Numerical simulations of the complete system confirm this analysis of the slow-flow dynamics. A parametric analysis of the influence of the NES damping coefficient and the rotor speed on the response regime is finally proposed.

MRI Artifacts

  • 최순섭
    • Investigative Magnetic Resonance Imaging
    • /
    • v.1 no.1
    • /
    • pp.51-57
    • /
    • 1997
  • MRI의 artifact는 대부분 신호의 부호화 방향에 따라서 방향성을 가지는데, 이를 요약해보면, 위상부호화 방향의 artifact에는 motion artifact, flow artifact, RF noise등이 있고, 주파수 부호화 방향의 artfact는 susceptibility artfact, chemical shift artifact, central line artifact등이 있으며, 양방향 모두 생길수 있는 것은 Aliasing artifact와 Gibb's phenomenon이고, 전체적으로 영샹의 질을 떨어뜨리는 것은 susceptibility artifact, Eddy current, cross talk등이 있다. 이런 artifact는 대부분은 MRI 자체의 물리적 특성에 다소간 기인하므로, artifact가 없는 양호한 영상을 얻기 위해서는 MRI의 설치 단계부터 관심이 필요하고, MRI의 기본원리와 다양한 artifact에 대해 이해함으로써, 제거 가능한 artifact는 제거하여 양질의 영상을 만들고 판독시의 오류를 피할 수 있도록 해야할 것이다.

  • PDF