• Title/Summary/Keyword: Flow Resonance

Search Result 476, Processing Time 0.024 seconds

Design of a Three Dimensional Folded Monopole Antenna Using Current Flow

  • Liu, Yulin;Lee, Seung-Woo;Kim, Nam
    • Journal of electromagnetic engineering and science
    • /
    • v.10 no.2
    • /
    • pp.67-72
    • /
    • 2010
  • A new type of monopole antenna whit broadband characteristics is presented in this article. To reduce the size of the antenna, its upper part is folded. By separating the current flow, the resonance in the shorter part is in the higher band; and the longer part resonates in the lower band. This gives the broadband characteristics of the antenna. Slots on the corner using an oblique line improve the impedance matching and bandwidth. The measurement results show that the bandwidth operates from 0.848~0.992 GHz and 1.744~2.528 GHz, and the radiation patterns are in an omni-directional shape.

THREE-DIMENSIONAL CRYSTALLIZING ${\pi}-BONDINGS,\;{\pi}-FAR$ INFRARED RAYS AND N-MACHINE

  • Oh, Hung-Kuk
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1996.10b
    • /
    • pp.34-44
    • /
    • 1996
  • N-machine produces more than input energy at above 3000 rpm. any space energy is absorbed when the N-machine is rotating at a very high velocity. Laws of electromagnetics verify that normal conduction is due to that electrons moves from one three-dimensional crystallizing ${\pi}-bonding$ orbital to next. The ${\pi}-far$ infrared rays are generated from the resonance and rotation of the electrons on the orbitals of three-dimensional crystallizing ${\pi}-bonding$ atoms. Material in universe is composed of ${\pi}-rays$, which have alternative outward electric field. If the alternative outward electric fields of the ${\pi}-rays$ are resonant each other they make attraction force, which is the gravity. The collection of space energy is due to a attraction force between the radially alternating electric field and the ${\pi}-far$ infrared rays in the space. Electrons flow by absorbed density difference of ${\pi}-far$ infrared rays along a conduction wire, which also verifies that normal electron conduction is due to a flow from one three-dimensional crystallizing ${\pi}-bonding$ orbital to next.

  • PDF

Visualization of Vortex Lock-on to Oscillatory Incident Flow in the Cylinder Wake Using Time-Resolved PIV (고속 PIV계측에 의한 실린더 근접후류 공진 유동 가시화)

  • 송치성
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.25 no.6
    • /
    • pp.1353-1361
    • /
    • 2001
  • Vortex lock-on or resonance behind a circular cylinder is visualized using a time-resolved PW when a single frequency oscillation is superimposed on the mean incident velocity. For vector processing, a cross-correlation algorithm in conjunction with a recursive correlation and interrogation window shifting techniques is used. Measurements are made of the Karmas and streamwise vertices in the wake-transition regime at Reynolds lumber 360. When lock-on occurs, the vortex shedding frequency is found to be half the oscillation frequency as expected from previous experiments. At the lock-on state, the Karman vortices are observed to be more disordered by the increased strength and spanwise wavelength of the streamwiee vortices, which lead? to a strong three-dimensional motion.

  • PDF

Computation of unsteady wind loading on bluff bodies using a discrete vortex method

  • Taylor, I.J.;Vezza, M.
    • Wind and Structures
    • /
    • v.2 no.4
    • /
    • pp.285-303
    • /
    • 1999
  • A discrete vortex method (DVM) has been developed at the Department of Aerospace Engineering, University of Glasgow, to predict unsteady, incompressible, separated flows around closed bodies. The basis of the method is the discretisation of the vorticity field, rather than the velocity field, into a series of vortex particles that are free to move in the flow. This paper gives a brief description of the method and presents the results of calculations on static and transversely oscillating square section cylinders. The results demonstrate that the method successfully predicts the character of the flow field at different angles of incidence for the static case. Vortex lock-in around the resonance point is successfully captured in the oscillatory cases. It is concluded that the vortex method results show good agreement, both qualitatively and quantitatively, with results from various experimental data.

MRI Artifacts and Reducing Techniques

  • 강해진
    • Proceedings of the KSMRM Conference
    • /
    • 1999.04a
    • /
    • pp.34-42
    • /
    • 1999
  • 의료영상에서 인공물(Artifacts) 이라 함은 영상이 얻어지는 신체부위와 아무런 관련이 없으나 얻어진 영상에는 마치 영상의 일부분으로 나타나는 모든 것을 가리킨다. 따라서 영상에서 이들 인공물들은 실제 조직의 해부학적인 구조를 나타내지 않으므로 영상 판독에 영향을 주어 잘못된 진단을 초래할 수도 있다. 그러나 MR 영상이 가능한 이래로 새로운 여러 종류의 MR 인공물들이 많이 발견 되었으나 다행스럽게도 거의 모든 MR 인공물들은 쉽게 설명이 가능하며, 따라서 이들 인공물들에 의한 진단 오류의 가능성은 매우 희박한 실정이다. 그러나 새로운 영상방법이나 혹은 새로운 펄스대열이 계속 고안됨에 따라 새로운 종류의 인 공물들이 생겨날 가능성은 항상 존재하고 있다. 지금까지 알려진 여러 MR 인공물들은 그 생겨난 원인에 따라 다음과 같이 크게 세 가지로 분류가 가능하다. I. Motion Artifacts 1. Voluntary motion 2. Involuntary motion 1) Bowel Peristalsis 2) Respiration 3) Cardiac and vessel pulsation 4) Swallowing 3. Fluid motion 1) Blood flow 2) Cerebrospinal fluid flow II. Reconstruction Artifacts 1. Aliasing 2. Partial volume averaging 3. Truncation (Ringing) 4. Central point III. Magnetic and RF Field Related Artifacts 1. Chemical shift 1) First kind 2) Second kind 2. Susceptibility 1) Dental 2) Metal 3. Magic angle 4. Zipper 5. Bad data point 6. RF field inhomogeneity 7. Magnetic field inhomogeneity 8. Eddy current 9. slice overlapping 10. Zebra 11. RF overflow

  • PDF

유압용 액셜 피스톤 펌프의 압력맥동 특성(유압필터에 의한 고주파 압력맥동의 흡수)

  • 김도태
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1998.03a
    • /
    • pp.281-286
    • /
    • 1998
  • In this paper, a Helmholtz resonator type hydraulic filter is proposed to absorb flow and pressure ripple produced from a axial piston pump. The basic principle of hydraulic filter is applied to propagation of preossure waves, reflection, absorption in cross section of discontinuity and resonance in the pipeline. This filter has advantage of the compact size and high degree of freedom of installation. The design scheme of hydraulic filter based on viscous wave theory are developed and manufactured two kinds of filter to investigate damping capability. It is experimently confirmed that these filter is absorbed to be about 20dB of flow and pressure ripple with high frequencies.

  • PDF

Definition and Improvement of the Sound which was Generated by Bubbles at the Accumulator of the Evaporator (증발기 어큐뮤레이터에서의 버블 소음 규명 및 개선)

  • 박정희;장의영;박윤서
    • Journal of KSNVE
    • /
    • v.6 no.4
    • /
    • pp.513-519
    • /
    • 1996
  • This paper is concerned with the bubble sound at the accumulator which is generated by the difference of the high pressure side and the low pressure side in the cycle of the refrigerator. The causes of the bubble sound generation are verified by the visualized test of the operating refrigerant flow at the accumulator and the measurements of the temperature and pressure. Two cases were tested, one with the accumulator has a orifice and the other with the accumulator hasn't a orifice. So that, it is presented the comparison of the bubble sound levels and spectrums in each cases. To predict the bubble sizes when they are generated, the linearized equation driven by Strasberg is used.

  • PDF

Phenomenon Examination on High Vibration of NG Boiler in 320MW Thermal Power Plant (320MW 화력발전소 가스 보일러 고 진동 현상 규명)

  • Kim, Yeon-Whan;Bae, Yong-Chae;Lee, Hyun;Kim, Hee-Soo;Lee, Doo-Young
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1034-1039
    • /
    • 2006
  • Large-amplitude, combustion-induced oscillations are observed in most systems involving continuous flow, such as aeroengine afterburners, gas boilers and rocket motors. Strong furnace vibration is typically characterized by the presence of well developed standing waves in the furnace, generating high pressure pulsation and causing structural vibration of the furnace walls. 320MW NG boilers have been experienced high vibration frequently since reconstruction works. Excessive furnace vibration was encountered when a burner air rate is suddenly reduced during load zone changed from 270MW to 300MW. An investigation showed that the primary cause of the vibration was induced by combustion low air flow rate. This paper describes phenomenon examination on strong furnace vibration due to the change of boiler operating conditions.

  • PDF

Formation of Reactive Oxygen Species and Cr(V) Entities in Chromium(VI) Exposed A549 Cells (크롬 6가 투여 후 A549 세포에서의 Reactive Oxygen Species와 크롬 5가의 발생)

  • 박형숙
    • Environmental Analysis Health and Toxicology
    • /
    • v.11 no.1_2
    • /
    • pp.49-57
    • /
    • 1996
  • The production of reactive oxygen species on addition of hexavalent chromium (potassium dichromate, $K_2Cr_2O_7$ ) to lung cells in culture was studied using flow cytometer analysis. A Coulter Epics Profile flow cytometer was used to detect the formation of reactive oxygen species after $K_2Cr_2O_7$ was added to A549 cells grown to confluence. The cells were loaded with the dye, 2',7'-dichlorofluorescein diacetate, after which cellular esterases removed the acetate groups and the dye was trapped intracellularly. Reactive oxygen species oxidized the dye, with resultant fluorescence. Increased doses of Cr(VI) caused increasing fluorescence (10-fold higher than background at 200 gM). Addition of Cr(III) compounds, as the picolinate or chloride, caused no increased fluorescence. Electron paramagnetic resonance (EPR) spectroscopic studies indicated that three (as yet unidentified) spectral "signals" of the free radical type were formed on addition of 20, 50, 100 and 200 gM Cr(VI) to the A549 cells in suspension. Two other EPR 'signals" with the characteristics of Cr(V) entities were seen at field values lower than the standard free radical value. radical value.

  • PDF

Vibration Reduction of an Air Cooled Heat Exchanger with Axial Flow Fan (축류송풍기 부착형 공냉식 열교환기의 진동 저감)

  • Jung, Goo-Choong;Choi, Yeon-Sun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.75-81
    • /
    • 2000
  • Vibration problems induced by an air cooled heat exchanger with axial flow fan were investigated during the operation of a petrochemical plant. Two different studies were done; one was experimental field test and the other was theoretical verification. To find main cause of the blade passing frequency of the fan after installing additional blockage board at the air inlet of the axial fan, the frequency spectrum was measured. The vibrations of the blade passing frequency became higher. The natural frequency of driving support of the heat exchanger was theoretically calculated. It was approximately equal to the blade passing frequency. During the normal operation of the plant, it was impossible to modify the structure of the driving support. Instead, the blade number was increased to reduce vibration level. It increased the ratio of the forcing frequency to the natural frequency of the driving support over the resonance region.

  • PDF