• Title/Summary/Keyword: Flow Resonance

검색결과 476건 처리시간 0.03초

Intra-Motion Compensation Using CSRS method in MRI

  • Ro, Y.M.;Yi, J.H.;Cho, Z.H.
    • 대한의용생체공학회:의공학회지
    • /
    • 제15권4호
    • /
    • pp.377-382
    • /
    • 1994
  • In the conventional Fourier imaging method in MRI (Magnetic Resonance Imaging), intramotion such as pulsatile flow makes zipper-like artifact along the phase encoding direction. On the other hand, line-integral projection reconstruction (LPR) method has advantages such as imaging of short T2, object and reduction of the flow artifact by elimination of the flow-induced phase fluctuation. The LPR, however, necessarily requires time consuming filtering and back-projection processes, so that the reconstruction takes long time. To overcome the long reconstruction time of the LPR and to obtain the flow artifact reduction effect, we adopted phase corrected concentric square raster sampling (CSRS) method and improved its imaging performance. The CSRS is a fast reconstruction method which has the same properties with the LPR. In this paper, we proposed a new method of flow artifact reduction using the CSRS method. Through computer simulations and experiments, we verified that the proposed method can eliminate phase fluctuations, thereby reducing the flow artifact and re- markably shorten the reconstruction time which required long time in the LPR.

  • PDF

Analytical Surge Behaviors in Systems of a Single-stage Axial Flow Compressor and Flow-paths

  • Yamaguchi, Nobuyuki
    • International Journal of Fluid Machinery and Systems
    • /
    • 제9권1호
    • /
    • pp.1-16
    • /
    • 2016
  • Behaviors of surges appearing near the stall stagnation boundaries in various fashions in systems of a single-stage compressor and flow-path systems were studied analytically and were tried to put to order. Deep surges, which enclose the stall point in the pressure-mass flow plane, tend to have either near-resonant surge frequencies or subharmonic ones. The subharmonic surge is a multiple-loop one containing, for example, in a (1/2) subharmonic one, a deep surge loop and a mild surge loop, the latter of which does not enclose the stall point, staying only within the stalled zone. Both loops have nearly equal time periods, respectively, resulting in a (1/2) subharmonic surge frequency as a whole. The subharmonic surges are found to appear in a narrow zone neighboring the stall stagnation boundary. In other words, they tend to appear in the final stage of the stall stagnation process. It should be emphasized further that the stall stagnation initiates fundamentally at the situation where a volume-modified reduced resonant-surge frequency becomes coincident with that for the stagnation boundary conditions, where the reduced frequency is defined by the acoustical resonance frequency in the flow-path system, the delivery flow-path length and the compressor tip speed, modified by the sectional area ratio and the effect of the stalling pressure ratio. The real surge frequency turns from the resonant frequency to either near-resonant one or subharmonic one, and finally to stagnation condition, for the large-amplitude conditions, caused by the non-linear self-excitation mechanism of the surge.

MR Findings of Seizure-Related Cerebral Cortical Lesions during Periictal Period

  • Kim, Na Yoon;Baek, Hye Jin;Choi, Dae Seob;Ha, Jee Young;Shin, Hwa Seon;Kim, Ju Ho;Choi, Ho Cheol;Kim, Ji Eun;Park, Mi Jung
    • Investigative Magnetic Resonance Imaging
    • /
    • 제21권2호
    • /
    • pp.82-90
    • /
    • 2017
  • Purpose: This study investigated the MRI, MR angiography (MRA) and MR perfusion findings of seizure-related cerebral cortical lesions during the periictal period. Materials and Methods: From a retrospective review of the institutional database between 2011 and 2014, a total of 21 patients were included in this study. Two radiologists assessed periictal MRI, including MRA and MR perfusion, in patients with seizure-related cortical lesions. The parameters examined include: location of cortical abnormality, multiplicity of the affected cortical region, cerebral vascular dilatation, perfusion abnormality and other parenchymal lesions. Results: All patients showed T2 hyperintense cerebral cortical lesions with accompanying diffusion restriction, either unilateral (18/21, 85.7%) or bilateral (3/21, 14.3%). Of the 21 patients enrolled, 10 (47.6%) had concurrent T2 hyperintense thalamic lesions, and 10 (47.6%) showed hippocampal involvement. Of the 17 patients (81%) who underwent MRA, 13 (76.5%) showed vascular dilatation with increased flow signal in the cerebral arteries of the affected cortical regions. On MR perfusion, all 5 patients showed cortical hyperperfusion, corresponding to the region of cortical abnormalities. Conclusion: Seizure-related cerebral cortical lesions are characterized by T2 and diffusion hyperintensities, with corresponding cerebral hyperperfusion and vascular dilatation. These findings can be helpful for making an accurate diagnosis in patients with seizure.

Guidelines for Cardiovascular Magnetic Resonance Imaging from the Korean Society of Cardiovascular Imaging (KOSCI) - Part 2: Interpretation of Cine, Flow, and Angiography Data

  • Lee, Jae Wook;Hur, Jee Hye;Yang, Dong Hyun;Lee, Bae Young;Im, Dong Jin;Hong, Su Jin;Kim, Eun Young;Park, Eun-Ah;Jo, Yeseul;Kim, Jeong Jae;Park, Chul Hwan;Yong, Hwan Seok
    • Investigative Magnetic Resonance Imaging
    • /
    • 제23권4호
    • /
    • pp.316-327
    • /
    • 2019
  • Cardiovascular magnetic resonance imaging (CMR) is expected to be increasingly used in Korea due to technology advances and the expanded national insurance coverage of these tests. For improved patient care, it is crucial not only that CMR images are properly acquired but that they are accurately interpreted by well-trained personnel. In response to the increased demand for CMR, the Korean Society of Cardiovascular Imaging (KOSCI) has issued interpretation guidelines in conjunction with the Korean Society of Radiology (KSR). KOSCI has also created a formal Committee on CMR Guidelines to write updated practices. The members of this Committee review previously published interpretation guidelines and discuss the patterns of CMR use in Korea.

수직 진동하는 소수성 표면 위 액적의 내부유동 및 증발특성 연구 (Internal Flow and Evaporation Characteristic inside a Water Droplet on a Vertical Vibrating Hydrophobic Surface)

  • 김훈;임희창
    • 대한기계학회논문집B
    • /
    • 제39권7호
    • /
    • pp.579-589
    • /
    • 2015
  • 본 연구의 목적은 수직으로 강제 진동하는 소수성 표면 위에 놓인 액적의 유동 및 증발 특성을 이해하는 것이다. 액적의 공진주파수를 예측하기 위해서 Lamb과 Strani and Sabetta의 이론적 고유진동수식을 이용하였고, 실험값과 비교하여 보다 근접한 고유진동수 식에 대해 타당성을 검증하였다. 액적의 형상 및 내부 유동을 가시화하기 위해 초고속카메라, 초접사렌즈 그리고 연속광을 사용하여 진동하는 소수성 표면 위 액적의 유동 및 증발 특성을 확인하였다. 그 결과 각각의 모드에서 액적은 다양한 형상을 가졌으며, 각각의 액적 내부에서 복잡한 와류가 관찰되었다. 일반적으로, 유동흐름이 대칭축을 따라 위로 상승하여 액적상단에서 표면을 따라 접촉선부근으로 이동하였고, 2차, 4차 모드는 분기형, 6차, 8차 모드는 큰 타원형의 유동패턴을 갖는 것을 확인하였다. 여러 가지 모드 중 4차 모드에서 가장 빠른 유동속도를 가졌으며, 다음은 8, 6, 2차 모드 순서였다. 네 가지 진동 모드에서의 증발률은 4, 8, 6, 2차 모드 순서로 빨랐으며, 각각의 공진에서는 그 주위 주파수 영역보다 빠른 증발률을 보였다. 마지막으로 진동을 이용한 액적의 증발은 4차 모드에서 진행되어야 보다 효율적인 진동 증발을 유도할 수 있다.

Analytical Study on Stall Stagnation Boundaries in Axial-Flow Compressor and Duct Systems

  • Yamaguchi, Nobuyuki
    • International Journal of Fluid Machinery and Systems
    • /
    • 제6권2호
    • /
    • pp.56-74
    • /
    • 2013
  • Stall stagnations in the system of axial-flow compressors and ducts occur in transition from deep surge conditions to decayed or converged stall conditions. The present study is concerned with the boundaries between the deep surges and the stagnation stalls on the basis of analytical results by a code on surge transients analysis and simulation. The fundamental acoustical-geometrical stagnation boundaries were made clear from examinations of the results on a variety of duct configurations coupled with a nine-stage compressor and a single stage fan. The boundary was found to be formed by three parts, i.e., B- and A-boundaries, and an intermediate zone. The B-boundary occurs for the suction-duct having a length of about a quarter of the wave-length of the first resonance in the case of very short and fat plenum-type delivery duct. On the other hand, the A-boundary occurs for the long and narrow duct-type delivery flow-path having a length about a fifth of the wavelength and relatively small sectional area in the case of short and narrow suction ducts. In addition to this, the reduced surge-cycle frequencies with respect to the duct lengths are observed to have respective limiting values at the stagnation boundaries. The reduced frequency for the B-boundary is related with a limiting value of the Greitzer's B parameter. The tendency and the characteristic features of the related flow behaviors in the neighborhood of the boundaries were also made clearer.

A study on the dynamic instabilities of a smart embedded micro-shell induced by a pulsating flow: A nonlocal piezoelastic approach

  • Atabakhshian, Vahid;Shooshtaria, Alireza
    • Advances in nano research
    • /
    • 제9권3호
    • /
    • pp.133-145
    • /
    • 2020
  • In this study, nonlinear vibrations and dynamic instabilities of a smart embedded micro shell conveying varied fluid flow and subjected to the combined electro-thermo-mechanical loadings are investigated. With the aim of designing new hydraulic sensors and actuators, the piezoelectric materials are employed for the body and the effects of applying electric field on the stability of the system as well as the induced voltage due to the dynamic behavior of the system are studied. The nonlocal piezoelasticity theory and the nonlinear cylindrical shell model in conjunction with the energy approach are utilized to mathematically modeling of the structure. The fluid flow is assumed to be isentropic, incompressible and fully develop, and for more generality of the problem both steady and time dependent flow regimes are considered. The mathematical modeling of fluid flow is also carried out based on a scalar potential function, time mean Navier-Stokes equations and the theory of slip boundary condition. Employing the modified Lagrange equations for open systems, the nonlinear coupled governing equations of motion are achieved and solved via the state space problem; forth order numerical integration and Bolotin's method. In the numerical results, a comprehensive discussion is made on the dynamical instabilities of the system (such as divergence, flutter and parametric resonance). We found that applying positive electric potential field will improve the stability of the system as an actuator or vibration amplitude controller in the micro electro mechanical systems.

비정상 열확산 현상 의 실험적 연구 (Experimental study of unsteady thermally stratified flow)

  • 이상준;정명균
    • 대한기계학회논문집
    • /
    • 제9권6호
    • /
    • pp.767-776
    • /
    • 1985
  • 본 연구에서는 초기 조건(입구 R$_{i}$수)의 변화에 따른 속도 분포, 온도 분 포, 확산율, 계면의 변화등을 연구하며, 난류 혼합과 계면의 불안정에 기인한 속도장 과 온도장의 변화과정을 가시화 사진과 비교 분석한다.다.

2차원과 3차원 아음속 공동 유동 특성에 대한 수치적 연구 (NUMERICAL ANALYSIS OF TWO- AND THREE-DIMENSIONAL SUBSONIC TURBULENT CAVITY FLOWS)

  • 최홍일;김재수
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2007년도 추계 학술대회논문집
    • /
    • pp.187-193
    • /
    • 2007
  • The flight vehicles have cavities such as wheel wells and bomb bays. The flow around a cavity is characterized as unsteady flow because of the formation and dissipation of vortices due to the interaction between the freestream shear layer and cavity internal flow, the generation of shock and expansion waves. Resonance phenomena can damage the structures around the cavity and negatively affect aerodynamic performance and stability. In the present study, numerical analysis was performed for cavity flows by the unsteady compressible three dimensional Reynolds-Averaged Navier-Stokes (RANS) equations with Wilcox's ${\kappa}\;-\;{\omega}$ turbulence model. The cavity has the aspect ratios of 2.5, 3.5 and 4.5 for two-dimensional case, same aspect ratios with the W/D ratio of 2 for three-dimensional case. The Mach and Reynolds numbers are 0.53 and 1,600,000 respectively. The flow field is observed to oscillate in the "shear layer mode" with a feedback mechanism. Based on the SPL(Sound Pressure Level) analysis of the pressure variation at the cavity trailing edge, the dominant frequency was analyzed and compared with the results of Rossiter's formula. The MPI(Message Passing Interface) parallelized code was used for calculations by PC-cluster.

  • PDF

경추간공 경막외 조영술의 양상에 관한 분석 (An Analysis of Pattern of Transforaminal Epidurography)

  • 홍지희
    • The Korean Journal of Pain
    • /
    • 제19권2호
    • /
    • pp.175-180
    • /
    • 2006
  • Background: A transforaminal epidural steroid injection has been used for the treatment of radicular arm or leg pain, which has the advantage of ventral epidural spreading compared to either an interlaminar or caudal approach. However, several factors are known to affect the epidural spread pattern of contrast dye; therefore, the injected medication can not be delivered to the target site. The objective of our study was to observe any differences in the contrast flow patterns according to several factors. Methods: A total of 34 epidurographies in 29 patients, who underwent fluoroscopically guided transforaminal epidural steroid injections, were evaluated. After confirming the location of the needle tip within the anterior superior aspect of the neural foramen in the lateral view, and at the 6 o'clock position to the pedicle in the anteroposterior view, 2 ml of contrast dye was injected. The contrast flow patterns of ventral, ventral and dorsal, and dorsal epidural filling were analyzed, according to age, gender, magnetic resonance imaging finding and history of previous back surgery. Results: Ventral contrast flow occurred in 30 out of the 34 epidurographies (88%). Both ventral and dorsal contrast flow patterns were observed 13 out of 16 (81%) patients in the older age group. Also, both ventral and dorsal contrast flow patterns were observed in 16 out of 18 (88%) patients with spinal stenosis. Conclusions: Transforaminal epidural steroid injections, performed uner fluoroscopy, provide excellent nerve root filling and ventral epidural spreading. Patients with spinal stenosis or an old age have both ventral and dorsal epidural spreading patterns.