Numerical Study on Reduction in Frictional Loss for a Sandwitch Type of Pressure Regulator (정압기의 유체력 손실 저감에 대한 수치해석적 연구)

  • Seo, Dong-Kyun;Lee, Jung-Hoon;Hwang, Jung-Ho;Kim, Kwang-Soo;Kim, Kang-Dae;Kim, Dong-Soo
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.2
    • /
    • pp.47-52
    • /
    • 2010
  • The development of energy saving system with pressure regulator has recently been received interests. Since the internal geometry in the pressure regulator is small and complex, the frictional loss in it is critical. In this study, the pressure loss with tip size, tip position, and mass flow was investigated using numerical approaches(CFD). The aimed reduction in pressure were achieved as the ratio of t/T was more than 0.8. In addition, there was no effect of the tip position.

PTA-I test of KSR-III Propulsion Feeding System (KSR-III 추진기관 공급계 PTA-I 종합수류시험)

  • 권오성;정영석;조인현;정태규;오승협
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.7 no.3
    • /
    • pp.22-29
    • /
    • 2003
  • The propulsion feeding system of KSR-III is composed of tubes, valves and PSC, and controls the flow of propellant entering to engine. The test of PTA-I is carried out to verify the characteristic of propulsion feeding system and component. The tests of operation characteristic of component, hydraulic characteristic of tubes, flow control using venturi, oscillation of dynamic pressure, characteristic of regulator are carried out. Troubles of component are found out, and renewed, and the performance of the propulsion feeding system is verified through PTA-I. The results of PTA-I are used to the configuration of propulsion feeding system and test of PTA-II.

Effect of Air Flow on Chemical Properties of Cured Leaves in Bulk Curing Process (황색종 Bulk건조과정의 송풍량과 건조엽의 화학성분 특성)

  • 이철환;진정의
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.21 no.2
    • /
    • pp.182-187
    • /
    • 1999
  • A bulk curing experiment was carried out to evaluate the effect of air flow reduction in the bulk barn from color fixing stage in the chemical properties of cured leaves, The air flow was controlled by reducing air velocity of a blower from 0.3m/sec to 0.2m/sec using a boltage regulator(Slidac). The bulk curing before color fixing stage was processed in the conventional curing method. Reduction of air circulation in bulk barn did not affected so much on change of the contents of the main chemical components in cured leaved, such as nicotine, total sugar, total nitrogen, petroleum ether extract, and organic acids. Only a slight increase in essential oil contents, such as solanone, damascenone, damascone, $\beta$-ionone, and megastigmatrienone isomer, could be observed in leaves cured in the reduced air flow.

  • PDF

A Control Method of Phase Angle Regulator for Parallel-Feeding Operation of AC Traction Power Supply System (교류전기철도 병렬급전 운영을 위한 위상조정장치 제어기법)

  • Lee, Byung Bok;Choi, Kyu Hyoung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.5
    • /
    • pp.672-678
    • /
    • 2020
  • The parallel-feeding operation of an AC traction power supply system has the advantages of extending the power supply section and increasing the power supply capacity by reducing the voltage drop and peak demand caused by a train operation load. On the other hand, the parallel-feeding operation is restricted because of the circulating power flow induced from the phase difference between substations. Moreover, the power supply capacity is limited because of the unbalanced substation load depending on the trainload distribution, which can be changed by the train operation along the railway track. This paper suggests a Thyristor-controlled Phase Angle Regulator (TCPAR) to reduce the circulating power flow and the unbalanced substation load, which depends on the phase difference and the trainload distribution and provides a feasibility study. A dedicated control model of TCPAR is also provided, which uses substation power supplies as the input to control the circulating power flow and an unbalanced substation load depending on the phase difference and the trainload distribution. Simulation studies using PSCAD/EMTDC shows that the proposed TCPAR control model can reduce the circulating power flow and the unbalanced substation load depending on the phase difference and the trainload distribution. The proposed TCPAR can extend the parallel-feeding operation of an AC traction power system and increase the power supply capacity.

Flow/Pressure/Power Control of Hydraulic Pump Utilizing Switching Control Mode (스위칭 제어 모드를 이용한 유압펌프의 유량/압력/동력 제어)

  • Jung, D.S.;Kim, H.E.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.4 no.4
    • /
    • pp.8-14
    • /
    • 2007
  • The electro-hydraulic pump is usually used in testing equipments which require one control function. But until now, it is not applied to industrial equipments which are exposed to severe working environment and require various control functions. This paper proposes a technique which controls continuously flow, pressure and power by utilizing switching control mode. Mathematical model is developed from the continuity equation for the pressurized control volume and the torque balance for the swash plate motion. To simplify the model we make the linear state equation by differentiating the nonlinear model. We analyze the stability and disturbance by using the state variable model. Finally, we review the control performances of flow, pressure and power by tests using PID controller.

  • PDF

Stabilization of Fuel F1ow in a Multi-Nozzle Combustion System Burning Natural Gas (천연가스 다노즐 열원설비의 연료 유동 안정화)

  • 박의철;차동진
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.12
    • /
    • pp.1255-1265
    • /
    • 2001
  • A numerical study has been conducted to characterize the transient flow in a utility gas turbine burning natural gas. The solution domain encompasses the supply gas pressure regulator to the combustor of the gas turbine that employs multi-nozzle fuel injectors. Some results produced for verification in the present study agree suite well with the experimental ones. It is found that the total gas flow may decrease noticeably during its combustion mode change, which would be the reason of momentary combustion upset, when a reference case of opening ratios of control valves in the system is applied. Several parameters are then varied in order to make the total gas flow stable over that period of time. Results of this study may be useful to understand the unsteady behavior of combustion system burning natural gas.

  • PDF

Dynamic Characterization of Passive Flow-Rate Regulator Using Pressure-Dependent Autonomous Deflection of Parallel Membrane Valves (압력에 따른 평행박막 밸브의 자율 변형을 이용한 수동형 유량 제어기의 동적특성 평가)

  • Doh, Il;Cho, Young-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.8
    • /
    • pp.825-829
    • /
    • 2011
  • We performed a dynamic characterization of passive flow-rate regulators, which compensate for inlet pressure variation and maintain a constant flow rate for precise liquid control in microfluidic systems. To measure the flow rate for a short time, much less than the period of the dynamic inlet pressure, we use the particle image velocimetry (PIV) method. DI water containing fluorescent beads with a $0.7-{\mu}m$ diameter was supplied to the flow-rate regulators, and two successive images of the particles were taken by a pulse laser and a fluorescent microscope to measure the flow velocity. For a dynamic inlet pressure of frequency 60 Hz, the flow velocity was constant with an average of 0.194 ${\pm}$ 0.014 m/s as the inlet pressure varied between 20 kPa to 50 kPa. The flow-rate regulators provided a constant flow rate of $5.82{\pm}0.29\;{\mu}l/s$ in the frequency range of the inlet pressure from 1 Hz to 60 Hz.

Numerical Analysis for Evaluation of Ejection Capacity Relationship of Safety Valves in Pressure Regulating Station (II) - Flow Analysis and Required Effective Discharge Area of Safety Valve - (정압기지내의 안전밸브 분출용량 관계식 검증을 위한 유동해석 (II) - 안전밸브 유동 해석 및 필요분출면적 -)

  • Gwon, Hyuk-Rok;Roh, Kyung-Chul;Kim, Young-Seop;Lee, Seong-Hyuk
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.2
    • /
    • pp.105-109
    • /
    • 2008
  • A safety valve has a valve mechanism for the automatic release of gas from piping system when the pressure exceeds preset limit cause of a defect of a pressure regulator, condensation of water in a pipe. Therefore, for the safety of pressure regulating station, it is essential to study the flow regime and characteristics of safety valve. This article presents the numerical analysis on the flow analysis, the ejection capacity and required effective discharge area of the safety valve that is established in pressure regulating station. Then, the results are compared and analyzed with domestic and foreign regulations such as API(America Petroleum Institute), EN(European Standard), and NF(Norme Francise). Moreover, the installation number of safety valve is considered by using domestic and foreign regulations and maximum reguired effective discharge area of safety valve.

  • PDF

Development of a Shut-off Device of LP Gas Regulator for Home Use (가정용 LP가스 조정기 차단안전장치의 개발)

  • Kim Young-Gyu;Kim Pil-Jong;Kwon Boo-Kil;Park Gyo-Shik;Kim Ji-Youn
    • Journal of the Korean Institute of Gas
    • /
    • v.10 no.3 s.32
    • /
    • pp.54-59
    • /
    • 2006
  • A safety device with shut-off function was developed for preventing intentional accidents that might happen by separating of cutting hoses connected to pressure regulators used in residential LP gas facility. For the verification of function and field adaptability, the safety device with shut-off function was tested in the state of joining the device to the regulator and a field test was carried out at home. This study shows that, at the inlet pressure of 0.07-1.56 MPa, the device shuts off the gas within the 5m length of hose regardless of the installation condition of the regulator. The shut-off flow rate increases in the order of perpendicular upward, horizontal and perpendicular downward. From the results of the field tests carried out at home for 5 months, there appears no problem using a gas range or a boiler. If the developed shut-off device is commercialized and distributed in the market the intentional accidents occurred by cutting or separating hoses can be prevented remarkably.

  • PDF