• Title/Summary/Keyword: Flow Recirculation

Search Result 658, Processing Time 0.025 seconds

Flow Control in the Vacuum-Ejector System (진공 이젝터 시스템의 유동 컨트롤)

  • Lijo, Vincent;Kim, Heuy-Dong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.05a
    • /
    • pp.321-325
    • /
    • 2010
  • Supersonic ejectors are simple mechanical components, which generally perform mixing and/or recompression of two fluid streams. Ejectors have found many applications in engineering. In aerospace engineering, they are used for altitude testing of a propulsion system by reducing the pressure of a test chamber. It is composed of three major sections: a vacuum test chamber, a propulsive nozzle, and a supersonic exhaust diffuser. This paper aims at the improvement of ejector-diffuser performance by focusing attention on reducing exhaust back flow into the test chamber, since alteration of the backflow or recirculation pattern appears as one of the potential means of significantly improving low supersonic ejector-diffuser performance. The simplest backflow-reduction device was an orifice plate at the duct inlet, which would pass the jet and entrained fluid but impede the movement of fluid upstream along the wall. Results clearly showed that the performance of ejector-diffuser system was improved for certain a range of system pressure ratios, whereas the orifice plate was detrimental to the ejector performance for higher pressure ratios. It is also found that there is no change in the performance of diffuser with orifice at its inlet, in terms of its pressure recovery. Hence an appropriately sized orifice system should produce considerable improvement in the ejector-diffuser performance in the intended range of pressure ratios.

  • PDF

Evaluation for the Numerical Model of a Micro-Bubble Pump (미세버블펌프 수치모델평가 및 검증)

  • LEE, SANG-MOON;JANG, CHOON-MAN
    • Journal of Hydrogen and New Energy
    • /
    • v.27 no.1
    • /
    • pp.121-126
    • /
    • 2016
  • Hydraulic performance of a micro-bubble pump has been analyzed by numerical simulation and experimental measurements. Flow recirculation apparatus between the pump inlet and outlet reserviors has been adopted to measure pump performance according to flow conditions sequentially. To analyze three-dimensional flow field in the micro-bubble pump, general analysis code, CFX, is employed. SST turbulence model is employed to estimate the eddy viscosity and compared the pump performance to k-${\varepsilon}$ model. Unstructured grids are used to represent a composite grid system including blade, casing and inlet casing. It is found that the numerical model used in the present study is effective to evaluate the pump performance. From the numerical simulation, low velocity region due to pressure loss is decreased where pump efficiency has maximum value. Detailed flow field inside the micro-bubble pump is also analyzed and compared.

A Numerical Study of the Flow Characteristics and Starting Pressure of a Center Body Diffuser According to the Center Body Position and Cone Angle (Center Body 위치와 Cone 각도에 따른 Center Body Diffuser의 유동특성 및 시동에 대한 수치적 연구)

  • Lee, Sung Hun;Park, Jin;Kim, Hong Jip
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.23 no.5
    • /
    • pp.10-18
    • /
    • 2019
  • In this study, flow characteristics and the starting pressure of a center body diffuser (CBD) were analyzed at various center body (CB) positions and cone angles. According to the CB position, the location of oblique shock moved to the front from behind the CB cone with an increase in the flow momentum. Additionally, when a strong oblique shock occurred, the direction of supersonic flow was affected and induced to diffuser wall. As a function of different cone angles for the oblique shock, the starting pressure of the CBD was significantly affected.

Numerical study on flow characteristics of a variable thrust side jet thruster with a rectangular nozzle (사각 노즐이 적용된 가변 추력용 측추력기의 유동특성에 관한 수치해석)

  • Kim, Li-Na;Sung, Hong-Gye;Jeon, Young-Jin;Cho, Seung-Hwan
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2012.05a
    • /
    • pp.110-116
    • /
    • 2012
  • To analyze flow characteristics and performance of the side jet thruster with 4 shutters and rectangular nozzles, a 3-D simulation has been implemented. Numerical calculations for three rotation anlgles of the shutter, have been conducted. Internal recirculation in a chamber and asymmetric flow structure in a nozzle were observed. In addition, the more shutter rotated, the more asymmetries of flow increased, and this phenomena resulted in thrust bias. The degrees of thrust bias and thrust performance with the rotation angles of the shutter were predicted and comparisons with theoretical thrust were made.

  • PDF

Numerical Study on the Flow Characteristics of a Side Jet Thruster Having Variable Thrust with a Rectangular Nozzle (사각 노즐이 적용된 가변 추력용 측추력기의 유동특성에 관한 수치해석)

  • Kim, Lina;Sung, Hong-Gye;Jeon, Young-Jin;Cho, Seunghwan
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.17 no.2
    • /
    • pp.63-70
    • /
    • 2013
  • To analyze flow characteristics of the side jet thruster with 4 shutters and rectangular nozzles, a 3-D simulation has been implemented. Numerical calculations for two rotation angles of the shutter, have been conducted. Internal recirculation in a chamber and asymmetric flow structure in a nozzle were observed. In addition, the more shutter rotated, the more asymmetries of flow increased, and this phenomena resulted in thrust bias. The degrees of thrust bias and thrust performance with the rotation angles of the shutter were predicted and compared with theoretical thrust.

Flow Characteristics in a Human Airway model for Oral Cancer Surgery by PIV Experiment and Numerical Simulation (PIV 측정 및 수치해석을 이용한 구강암 수술에 따른 기도 형상 내 유동 특성)

  • Hong, Hyeonji;An, Se Hyeon;Seo, Heerim;Song, Jae Min;Yeom, Eunseop
    • Journal of the Korean Society of Visualization
    • /
    • v.19 no.3
    • /
    • pp.115-122
    • /
    • 2021
  • Oral cancer surgery typically consists of resection of lesion, neck dissection and reconstruction, and it has an impact on the position of hyoid bone. Therefore, morphological change of airway can occur since the geometric parameter of airway is correlated with the hyoid bone. Airflow is affected by geometry of the airway. In this study, flow characteristics were compared between pre- and post-surgery models by both particle image velocimetry (PIV) and numerical simulation. 3D model of upper airway was reconstructed based on CT data. Velocity is accelerated by the reduced channel area, and vortex and recirculation region are observed in pre- and post-surgery models. For the post-surgery model, high pressure distribution is developed by significantly decreased hydraulic diameter, and the longitudinal flow stream is also interrupted.

An Experimental Study on Tip Velocity and Downstream Recirculation Zone of Single Groyne Conditions (단일 횡수제 조건에 따른 선단부 유속과 재순환 영역에 대한 실험 연구)

  • Kang, Joon-Gu;Yeo, Hong-Koo;Kim, Sung-Jung
    • Journal of Korea Water Resources Association
    • /
    • v.38 no.2
    • /
    • pp.143-153
    • /
    • 2005
  • Recently, the concern of groynes that provide us with various ecological environment and improvement of scenary near river as well as hydraulic improvement has greatly increased for naturalized river and ecological river restoration. However there is no adequate design guidelines in Korea. Furthermore there is lack of research for installation of groynes in Korea. Thus, in this study, we have conducted hydraulic modeling test for kinds of groyne and changes of permeability and made a study of the analysis for installation factor of groyne. Experimental conditions were the fixed bed model for flow pattern of groyne tip and separation length about changes of groyne length and permeability. The Experiments were conducted to measure velocity and drift angle at groyne tip. The main study kas measured the groyne tip velocity for a factor of scour and drift angle for velocity increase at center of channel. We have suggested the equation about groyne tip velocity rate(tip velocity/ approach velocity) and area rate(groyne area/ flow area). And In recirculation zone of groyne downstream, To study the basic data of groyne about installation interval has analyzed the change of separation length and incidence angle. We have suggested the equation about separation length rate(separation length/ groyne length), changes of permeability and installation angle.

The Starting Characteristics of the Steady Ejector-Diffuser System

  • Gopalapillai, Rajesh;Kim, Heuy-Dong;Matsuo, Shigeru;Setoguchi, Toshiaki
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.03a
    • /
    • pp.680-685
    • /
    • 2008
  • The ejector is a simple device which can transport a low-pressure secondary flow by using a high-pressure primary flow. In general, it consists of a primary driving nozzle, a mixing section, and a diffuser. The ejector system entrains the secondary flow through a shear action generated by the primary jet. Until now, a large number of researches have been made to design and evaluate the ejector systems, where it is assumed that the ejector system has an infinite secondary chamber which can supply mass infinitely. However, in almost all of the practical applications, the ejector system has a finite secondary chamber implying steady flow can be possible only after the flow inside ejector has reached an equilibrium state after the starting process. To the authors' best knowledge, there are no reports on the starting characteristics of the ejector systems and none of the works to date discloses the detailed flow process until the secondary chamber flow reaches an equilibrium state. The objective of the present study is to investigate the starting process of an ejector-diffuser system. The present study is also planned to identify the operating range of ejector-diffuser systems where the steady flow assumption can be applied without uncertainty. The results obtained show that the one and only condition in which an infinite mass entrainment is possible is the generation of a recirculation zone near the primary nozzle exit. The flow in the secondary chamber attains a state of dynamic equilibrium at this point.

  • PDF

Numerical Simulation and PIV Measurement on the Internal Flow in a Centrifugal Mini Pump at Low Flow Rate Conditions

  • Yuan, Hui-Jing;Shao, Jie;Cao, Guang-Jun;Liu, Shu-Hong;Wu, Yu-Lin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.03a
    • /
    • pp.775-780
    • /
    • 2008
  • This paper reports on the internal flow of a centrifugal mini pump working at the low flow rate operating conditions. The RNG $\kappa-\varepsilon$ turbulence model was employed to simulate the three-dimensional turbulent flow in the pump. To examine and certify the simulation results, a transparent acrylic centrifugal mini pump model which is suitable for PIV measurement has been developed. The tongue region and the passages region between blades were investigated using PIV. In order to eliminate the effect of refraction on the area closed to the wall and increase the measurement accuracy, the fluorescent particles were scatted into the working fluid with the tracing particles. It is found from the calculation and PIV measurement results that there is a large area of recirculation flow near the tongue at low flow rate operating conditions. The computationally predicted water head using the $\kappa-\varepsilon$ turbulence model at low flow rate operating conditions are in very good agreement with the experimentally measured water head and the mean velocity distributions at investigation area obtained by PIV and calculation showed a satisfactory agreement as well. Meanwhile, the results of PIV measurements show that the flow status in one passage is different to another. And for capturing the internal flow detail information, the $\kappa-\varepsilon$ turbulence model is not very suitable.

  • PDF

Three-Dimensional Flow Visualization for the Steady and Pulsatile Flows in a Branching Model using the High-Resolution PIV System

  • Suh, Sang-Ho;Roh, Hyung-Woon
    • International Journal of Vascular Biomedical Engineering
    • /
    • v.2 no.2
    • /
    • pp.27-32
    • /
    • 2004
  • The objective of the present study is to visualize the steady and pulsatile flow fields in a branching model by using a high-resolution PIV system. A bifurcated flow system was built for the experiments in the steady and pulsatile flows. Harvard pulsatile pump was used to generate the pulsatile velocity waveforms. Conifer powder as the tracing particles was added to water to visualize the flow fields. CCD cameras($1K{\times}1K$(high resolution camera) and $640{\times}480$(low resolution camera)) captured two consecutive particle images at once for the image processing of several cross sections on the flow system. The range validation method and the area interpolation method were used to obtain the final velocity vectors with high accuracy. The results of the image processing clearly showed the recirculation zones and the formation of the paired secondary flows from the distal to the apex of the branch flow in the bifurcated model. The results also indicated that the particle velocities at the inner wall moved faster than the velocities at the outer wall due to the inertial force effects and the helical motions generated in the branch flows as the flow proceeded toward the outer wall. Even though the PIV images from the high resolution camera were closer to the simulation results than the images from the low resolution camera at some locations, both results of the PIV experiments from the two cameras generally agreed quite well with the results from the computer simulations. Therefore, instead of using the expensive stereoscopic PIV or 3D PIV system, the three-dimensional flow fields in a bifurcated model could be easily and exactly investigated by this study.

  • PDF