• 제목/요약/키워드: Flow Rate comparison

검색결과 702건 처리시간 0.029초

원자력 발전소용 순환수 펌프의 성능해석 (THE PERFORMANCE ANALYSIS OF A CIRCULATING WATER PUMP FOR A NUCLEAR POWER PLANT)

  • 이명수;한병윤;황도연;유성수;박형구
    • 한국전산유체공학회지
    • /
    • 제14권3호
    • /
    • pp.69-75
    • /
    • 2009
  • The objective of this study is to investigate the suitable design for a domestic Circulating water pump(CWP), which is used in cooling-water intakes for the unit 3 and 4 of Yeonggwang nuclear power plant. All the simulations are performed, using CFD method with a commercial code STAR-CCM+ version 3.02. After modeling a present design of the pump, the flow around the rotating blade was calculated by using quasi-static method and sliding mesh method with the almost same condition as an actual state. Based on fundamental simulations with various depth of sea water, the reference pressure for the boundary condition of the present study was decided. To verify the reliability of the calculation results, the suction flow rate of the data was compared with that of the experimental data. As a result of this comparison, it is confirmed that two results are fairly consistent. For the improvement of the suction flow rate, computational analysis was done by changing a flow channel and blade shapes. It is shown that the suction flow rate of the new pump was improved.

축류형 이중 블레이드 팬의 공기 유동 특성에 관한 실험적 연구 (Experimental Study on Air Flow Characteristics of Axial Dual-blade Fan)

  • 김해지;이용민
    • 한국기계가공학회지
    • /
    • 제13권4호
    • /
    • pp.113-120
    • /
    • 2014
  • To ventilate indoor spaces, axial single-blade fans are widely used in various areas, such as schools, houses, offices, and restaurants. Recently, axial single-blade fans were developed to realize energy efficiency and noise reduction improvements. Here, an experimental study of the air flow characteristics of an axial dual-blade fan is conducted. The characteristics of the axial dual-blade fan were tested via an air flow analysis and with prototypes. For the performance of the fan, the flow rate, power consumption, and noise were evaluated. The result showed that the axial dual-blade fan uses less power and produces less noise in comparison with an axial single-blade fan.

축방향과 반경방향흐름 크로마토그래피의 단백질 분리속도와 분리능에 대한 비교 (Comparison of Axial and Radial Flow Chromatography on Protein Separation Speed and Resolution)

  • 김윤하;이은규
    • KSBB Journal
    • /
    • 제10권5호
    • /
    • pp.482-490
    • /
    • 1995
  • The relationship between pressure drop and liquid flow rate, for an axial and a radial flow chromatographic column packed with compressible porous media was theoretically analyzed using modified Kozeny-Carman equation. The results were compared with experimental observations obtained using compressible DEAE-agarose as a model medium. At 2-9 psi range studied, the theoretical derivation accounting for 'gel compression' effect predicted simple Langmuirian type response of volumetric flow rate to changes in pressure drop. On the other hand, the experimental response was more or less sigmoidal. At the same pressure drop, radial column showed 2-3 times higher flow rates than those of axial column both theoretically and experimentally. Using r-HBsAg crude extract, protein resolution effects between the two types of columns at different flow rates were compared side-by-side. It turned out that, though general chromatographic behavior was very similar, axial column was somewhat superior in terms of r-HBsAg recovery yield and specificity. However, the number of theoretical plates analysis indicated the protein resolution effects were comparable.

  • PDF

자동차 에어컨용 평행류 응축기의 성능평가 (Performance Evaluation of a Parallel Flow Condenser for Automotive Air Conditioners)

  • 장혁재;강병하
    • 설비공학논문집
    • /
    • 제15권4호
    • /
    • pp.247-253
    • /
    • 2003
  • The new shape of louver-fin has been applied to a parallel flow condenser to enhance air-side heat transfer rate lot an automotive air-conditioner R- l34a is employed as a refrigerant inside the flat tube of the condenser, This problem is of particular interest in reducing the geometric size of the automotive air conditioner The effect of air flow rate on pressure drop as well as heat transfer in air side are studied in detail. Comparison of the performance is also made with that of a conventional parallel flow condenser, which is available in the market. The results obtained indicate that the total pressure drop through the pre sent condenser is not changed, while the heat transfer rate is increased by 24% at high veto city of air flow, compared with those of the conventional condenser. The parallel flow condenser with a new shape of louver-fin could be reduced in size by 20% for the equivalent condenser capacity, compared with the conventional parallel flow condenser.

고분자 반응기의 내부 유동 특성에 관한 연구 (Study on the flow characteristics of the polymer reactors)

  • 최두성;임예훈;한상필
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2002년도 춘계 학술대회논문집
    • /
    • pp.134-139
    • /
    • 2002
  • This study is focused on investigating the characteristics of internal flow of the polymer reactor and its effect on the polymer quality. Four types of polymer reactor which have different kind of impeller, baffle and operation condition were calculated by CFD. Fluent 6 have been used to simulate mixing phenomena of reactor. According to the comparison of computational results and SEM photographs of polymer particle, distribution of turbulent dissipation rate greatly influences on the quality of polymer. So, distribution of turbulent dissipation rate to be important criterion to predict polymer quality.

  • PDF

A constitutive model for fiber-reinforced extrudable fresh cementitious paste

  • Zhou, Xiangming;Li, Zongjin
    • Computers and Concrete
    • /
    • 제8권4호
    • /
    • pp.371-388
    • /
    • 2011
  • In this paper, time-continuous constitutive equations for strain rate-dependent materials are presented first, among which those for the overstress and the consistency viscoplastic models are considered. By allowing the stress states to be outside the yield surface, the overstress viscoplastic model directly defines the flow rule for viscoplastic strain rate. In comparison, a rate-dependent yield surface is defined in the consistency viscoplastic model, so that the standard Kuhn-Tucker loading/unloading condition still remains true for rate-dependent plasticity. Based on the formulation of the consistency viscoplasticity, a computational elasto-viscoplastic constitutive model is proposed for the short fiber-reinforced fresh cementitious paste for extrusion purpose. The proposed constitutive model adopts the von-Mises yield criterion, the associated flow rule and nonlinear strain rate-hardening law. It is found that the predicted flow stresses of the extrudable fresh cementitious paste agree well with experimental results. The rate-form constitutive equations are then integrated into an incremental formulation, which is implemented into a numerical framework based on ANSYS/LS-DYNA finite element code. Then, a series of upsetting and ram extrusion processes are simulated. It is found that the predicted forming load-time data are in good agreement with experimental results, suggesting that the proposed constitutive model could describe the elasto-viscoplastic behavior of the short fiber-reinforced extrudable fresh cementitious paste.

유동 가시화와 LDV 측정을 이용한 흡기계 내의 유동장에 관한 실험적 해석 (An Experimental Analysis of the Flow Field in an Air Induction System by Flow Visualization and LDV Measurements)

  • 유성출
    • 한국자동차공학회논문집
    • /
    • 제9권1호
    • /
    • pp.102-111
    • /
    • 2001
  • To describe the air flow characteristics within an air cleaner cover and mass air flow sensor (MAFS) entry region installed in a 3.0L engine air induction system, flow visualization, velocity and turbulence intensity measurements were taken in several view planes. A detailed knowledge of the interaction between the design parameters and the flow structures will enhance our understanding of the motions within the flow field and enable engineers to optimize the induction system and reduce the signal-to-noise ratio in the MAFS output. Emphasis is placed on the analysis of coherent motions and the controlling parameters which affect the air flow in the MAFS entrance region over a flow rate of 13-240 kg/hr. The high speed motion pictures illustrated that the air flow generated within the air cleaner cover under steady state condition is quite complex. In both axial and radial planes of the main passage it was found that the flow pattern is remarkably influenced by the air cleaner cover and main passage configuration. A comparison of the flow patterns and measurements in the original and modified air cleaner cover is presented. Measurements from the MAFS indicated an significant reduction in pressure drop and signal noise for the modified cover as compared with the original cover, over an air flow rate of 13-240 kg/hr.

  • PDF

Research on the Variable Rate Spraying System Based on Canopy Volume Measurement

  • Hu, Kaiqun;Feng, Xin
    • Journal of Information Processing Systems
    • /
    • 제15권5호
    • /
    • pp.1131-1140
    • /
    • 2019
  • Characteristics of fruit tree canopies are important target information for adjusting the pesticide application rate in variable rate spraying in orchards. Therefore, the target detection of the canopy characteristics is very important. In this study, a canopy volume measurement method for peach trees was presented and a variable rate spraying system based on canopy volume measurement was developed using the ultrasonic sensing, one of the most effective target detection method. Ten ultrasonic sensors and two flow control units were mounted on the orchard air-assisted sprayer. The ultrasonic sensors were used to detect the canopy diameters and the flow controls were used to modify the flow rate of the nozzles in real time. Two treatments were established: a constant application rate of $300Lha^{-1}$ was set as the control treatment for the comparison with the variable rate application at a $0.095Lm^{-3}$ canopy. The tracer deposition at different parts of peach trees and the tracer losses to the ground (between rows and within rows) were analyzed in detail under constant rate and variable rate application. The results showed that there were no significant differences between two treatments in the liquid distribution and the capability to reach the inner parts of the crop canopies.

연소기를 위한 전후방 유동성형에서의 성형력 비교 (Comparison of Forming force on forward and Backward Flow Forming for Combustion Chamber)

  • 남경오;조천휘;홍성인
    • 한국추진공학회지
    • /
    • 제10권4호
    • /
    • pp.34-39
    • /
    • 2006
  • 두께가 얇고 길이가 긴 튜브 제품을 생산하기 위한 방법으로 유동성형 공정이 많이 이용되고 있으며 이는 다른 가공방법에 비해 성형력이 작고 유동성형에 의해 가공된 제품의 기계적인 강도가 우수하기 때문이다. 특히 유동성형은 로켓 모터 케이스, 연소기, 유압 실린더 그리고 고압용기 등과 같은 고정밀도의 두께가 얇은 실린더 제품을 생산하기 위한 적합한 공정이다. 본 논문에서는 3개의 롤러를 가지는 전후방 유동성형에 대한 유한요소해석을 통해 가공깊이와 가공속도가 성형력에 미치는 영향을 살펴보았다. 다양한 가공깊이와 가공속도 조건에서 얻어진 전후방 유동성형에서의 축방향과 반경방향의 성형력을 비교하였다.

화학레이저 구동용 이젝터 시스템 개발 (III) - 고출력 화학레이저용 실물 크기의 이젝터 시스템 개발 및 성능 검증 - (Development of an Ejector System for Operating of Chemical Lasers (III) - Development and Performance Validation of a Full-Scale Ejector System for High Power Chemical Lasers -)

  • 김세훈;진정근;권세진
    • 대한기계학회논문집B
    • /
    • 제29권1호
    • /
    • pp.9-15
    • /
    • 2005
  • From the geometric parameter study, an optimal ejector design procedure of pressure recovery system for chemical lasers was acquired. For given primary flow reservoir conditions, an up-scaled ejector was designed and manufactured. In the performance test, secondary mass flow rate of 100g/s air was entrained satisfying the design secondary pressure, $40{\sim}50torr$. Performance validation of a supersonic ejector system along with an investigation of effects of supersonic diffuser was conducted. Placement of the diffuser at the secondary inlet further reduced diffuser upstream pressure to 7torr. Lastly, the duplicate of apparatus (air 500g/s secondary mass flow rate each) was built and connected in parallel to assess proportionality behavior on a system to handle larger mass flow rate. Test and comparison of the parallel unit demonstrated the secondary mass flow rate was proportional to the number of individual units that were brought together maintaining the lasing pressure.