• Title/Summary/Keyword: Flow Rate Ratio

Search Result 1,850, Processing Time 0.028 seconds

Thrbulent Wake Structure behind Rectangular Cylinders in a Uniform Shear Flow (균일한 전단류에 놓인 각주 후류의 난류구조)

  • 부정숙;양종필;구명섭
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.18 no.1
    • /
    • pp.101-113
    • /
    • 1994
  • This research has presented and experimental investigation on the characteristics of turbulent wake past a rectanular cylinder, according to various width/height ratio such as B/H=2.0, 2.79, 3.0, and 4.0 in a uniform shear flow. In order to perform this study, a special shear flow generator which produces the uniform shear flow has been designed and manufactured. It is found that the characteristics of the wake in a uniform shear flow are quite different from those of a uniform flow and vary with shear rate. And also, the formation of regular vortex structure is concerned with shear rate.

  • PDF

Pressure Drop and Leakage Performances of Flat Seals with Inclined Grooves (경사 그루브를 갖는 평판 실의 압력 강하 및 누설 성능)

  • Jung, Jin Woo;Jeong, Gwon Jong;Hwang, Sung Ho;Kim, Tae Ho;Kim, Eojin
    • Tribology and Lubricants
    • /
    • v.38 no.5
    • /
    • pp.213-221
    • /
    • 2022
  • This paper presents performance measurements of pressure drop and leakage flow rate of test flat seals with asymmetric inclined grooves. This study aims to reveal the influence of groove shapes, often machined in radial film riding-face seals, in forming a hydrodynamic wedge on leakage performance. A test facility was developed, and test seals were manufactured to study the effects of the inlet pressure level, ratio of inlet to outlet pressure, seal groove length, and seal groove height on the steady-state pressure drop and leakage performance. A series of tests were conducted, and the test data were compared to the predictions from a simple and efficient mathematical model using a one-dimensional Reynolds equation. The test results revealed that an increase in the inlet pressure increased the pressure drop through the test seals. The leakage flow rate increased significantly as the inlet pressure and ratio of the inlet to outlet pressure increased. The groove shape also affects seal performance. An increase in the groove length and height resulted in an evident increase in the leakage flow rate. The simple model predictions underestimated the leakage flow rates but showed good agreement with the trend in the measurements for all test operating conditions and changes in the groove shape.

The Effect of Aspect Ratio on the Flow Characteristics of Elliptic Jets (종횡비에 따른 타원제트의 유동특성에 관한 실험적 연구)

  • 권영철;이상준
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.6
    • /
    • pp.1156-1162
    • /
    • 1992
  • The effect of aspect ratio on the flow characteristics of elliptic jets was experimentally investigated. The flow characteristics of sharp-edged elliptic nozzles with aspect ratio of 1 (round nozzle), 2 and 4 were measured by using a 3-D LDV system along the major and minor axis at X/De = 2, 3, 5, 7 and along the centerline up to X/De = 14. At each measurement point mean velocites, turbulent intensities, skewness of three orthogonal velocity components, and Reynolds shear stress were obtained. The Reynolds number based on the nozzle exit velocity and nozzle equivalent diameter(De) was about 4 * 10$^{4}$. Difference in the spreading rate along the major and minor axis was remarkable. The jet half width along the major axis decreased at first and then increased again with going downstream. But the jet width along the minor axis increased steadly. The elliptic jet of AR = 2 had two switching points within the measurement range, while that of AR = 4 had only one. (AAA) : The elliptic jet of AR = 2 showed larger velocity decay rate than that of AR = 1 and AR = 4. The effect of aspect ratio on the flow characteristics of elliptic jets was dominant in the near jet regions of X/De < 7, and the skewness and Reynolds shear stress had quite different distribution depending on the aspect ratio of the elliptic nozzle.

Performance Test for a Centrifugal Air Compressor (원심형 공기압축기 성능시험)

  • 신유환;안이기;김광호;손병진
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.8
    • /
    • pp.1964-1971
    • /
    • 1995
  • In the present study, the performance characteristics of a centrifugal air compressor were investigated experimentally. The PC controlled performance test facility for a centrifugal air compressor driven by an electric motor with a gear box to achieve higher compressor rotating speed was set up in the present study. The performance test for a turbocharger compressor of a diesel engine was conducted, and in a case of 34,800 rpm, pressure ratio 1.18, flow rate 0.09kg/s, compressor efficiency 61% were investigated. Adiabatic power for a tested compressor showed maximum value at mass flow ratio 0.8. The value of mass flow ratio of maximum efficiency was about 0.37, it was independent of compressor rotating speed.

Effect of Aspect Ratio on Gas Microchannel Flow (마이크로채널 흐름에 관한 종횡비의 영향)

  • Tajul, Islam;Lee, Y.W.
    • Journal of Power System Engineering
    • /
    • v.11 no.3
    • /
    • pp.16-21
    • /
    • 2007
  • Three dimensional numerical study was carried out to investigate the effect of aspect ratio on microchannel flow. We considered five straight rectangular channels with aspect ratios (height/width) 0.2, 0.4, 0.6, 0.8 and 1.0. Nitrogen gas flow was investigated for both slip and noslip wall boundary conditions. Isothermal wall condition was assumed. We used control volume method for this simulation. The slip velocity increases with the increase of aspect ratio. Friction coefficient decreases with the increase of aspect ratio. Slip friction coefficient is lower than noslip friction coefficient. Mass flow rate of slip model is higher than that of noslip model. We compared our results with the experimental result reported in the literature. The agreement was good.

  • PDF

Micro-PIV Measurement on the droplet formation in a microfluidic channel (미세유체소자 내부에서의 Droplet 형성에 대한 Micro-PIV 측정)

  • Yoon, Sang-Youl;Ko, Choon-Sik;Kim, Jae-Min;Kim, Kyung-Chun
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1534-1539
    • /
    • 2004
  • This experiment has been carried out to measure the process of droplet formation between water phase fluid(PVA 3%) and organic phase fluid(oil) and vector fields measured by a Dynamic Micro-PIV method in the inside of a droplet while generated. Droplet length controlled by changing flow rate conditions in microchannel. Water-in-oil(W/O) droplets successfully generated at a Y junction and cross microchannel. But oil-in-water(O/W) droplets could not be formed at a Y junction microchannel. That is, PVA 3% flow could not be detached from the PDMS surface and ran parallel with oil flow. When PVA 3% flow rate was constant, droplet length and time period decreased as oil flow rate increased, but droplet frequency increased. When PVA 3% and oil flow rate ratio was constant, droplet length and time period decreased as flow rate increased, but droplet frequency increased. All that case, Standard deviation of droplet formation have less than 5% at averaged droplet length and regular-sized droplets were reproducibly formed.

  • PDF

Effects of the Welding Parameters on the Weld Shape in Nd:YAG Laser Welding of STS 304L (STS 304L의 Nd:YAG 레이저 용접에서 용접조건이 용접부 형상에 미치는 영향)

  • 이형근;석한길;한현수;박울재;홍순복
    • Journal of Welding and Joining
    • /
    • v.22 no.1
    • /
    • pp.58-64
    • /
    • 2004
  • The control of the weld bead shape is important in laser welding of the small parts. The effects of laser welding parameters on the weld bead shape in the pulsed Nd:YAG laser welding of STS 304L material were investigated. Shielding gas type, flow rate, pumping voltage, pulse frequency, pulse width, focal position and overlap distance were selected as laser welding parameters. Experiments were designed and conducted using the Taguchi method which was a statistical experimental method. The weld bead width, penetration, area and aspect ratio were measured and analysed as the weld bead shape properties and the welding parameters were optimized to maximize the weld aspect ratio. Weld aspect ratio were greatly affected by the pulse width, pumping voltage and pulse frequency, and somewhat by the overlap distance, and little by the shielding gas type, flow rate and focal position. A confirmation experiment were conducted using the optimized welding parameters.

Mist Cooling of High-Temperature Cylinder Surface (고온 실린더의 미스트 냉각)

  • Kim, Mu-Hwan;Lee, Su-Gwan;Park, Ji-Man;Lee, Pil-Jong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.3
    • /
    • pp.448-457
    • /
    • 2002
  • Heat treatment such as quenching of a high-temperature cylinder is being used on steel to produce high strength levels. Especially, the mist cooling with the high and uniform surface heat flux rate s expected to contribute for better products. The experimental mist cooling curve is produced for better understanding, and two distinct heat transfer regions are recognized from the cooling curve produced. It is shown that the liquid film evaporation dominated region follows the film boiling-dominated region as decreasing the temperature of test cylinder by mist flow. Based on the intuitive view from some previous investigations, a simplified model with some assumptions is introduced to explain the mist cooling curve, and it is shown that the estimation agrees well with our experimental data. In the meanwhile, it is known that the wetting temperature, at which surface heat flux rate is a maximum, increases with mass flow rate ratio of water to air ($\varkappa$ < 10). However, based on our experimental data, it is explained that there exists a critical mass flow rate ratio, at which the wetting temperature is maximum, in the range of 3 < $\varkappa$ < 130. Also, it is described that despite of the same value of $\varkappa$, the wetting temperature may increase with mist velocity.

Flow analysis of Buoyant Jets into Storage Tank through Variable Nozzles (각종 Nozzle을 통하여 저장조내로 유입되는 BUOYANT JETS의 유동해석)

  • Pak, Ee-Tong;Cho, Woon
    • Solar Energy
    • /
    • v.9 no.2
    • /
    • pp.42-50
    • /
    • 1989
  • The Buoyant Jets were analysed experimentally changing flow rate (0.0291/s, 0.0371/s, 0.0451/s), ratio of nozzle tip area to throat area (aspect ratio ${\beta}$=0.4, 1.0, 1.9), and also the temperature difference (${\Delta}T=Ti-T{\infty}$) between the temperature of the inflow water into the storage tank ($1m{\times}1m{\times}3m$) and the mean temperature of the water in the storage tank were changed as $25^{\circ}C,\;35^{\circ}C$ and $45^{\circ}C$. The more aspect ratio decreased, the more the trajectories of Buoyant Jets center-line were decreased and not the more the trajectories of Buoyant Jets centerline were influenced by the increment of the difference of the temperature. The more aspect ratio decreased, the more the half widths and dilution ratio of Buoyant Jets were increased and not the more the half widths and dilution ratio of Buoyant Jets were influenced by the increment of the difference of the temperature. Fr number is the factor that can predict the flow pattern over the whole flow field. And yet for the consideration the near field of Buoyant Jets flow pattern is dominated by magnitude of momentum and buoyancy force.

  • PDF

The Degumming and Sericin Recovery of the Silk fabric Using the Electrolytic Water(II) (전해수를 이용한 견섬유 정련 및 세리신 회수(II)-분리막에 의한 세리신 농축을 중심으로-)

  • 배기서;이태상;노덕길;홍영기
    • Textile Coloration and Finishing
    • /
    • v.16 no.4
    • /
    • pp.10-18
    • /
    • 2004
  • In this work, Aqueous sericin solution was prepared by degumming process with electrolytic reduction water. Then, the microfiltration and ultrafiltration systems were applied to the concentration of aqueous sericin solution. The objective of this study was to select the optimum operating condition among the different pressure. The permeate flux and rejection ratio were observed with time, pressure, flow rate and concentration. and, the wastewater and permeated water quality values such as pH, BOD, COD, and NH levels were measured. In order to see the influence of electrolytic reduction water, the flux of pure water and electrolytic reduction water by PVDF22(MF) and PS100(UF) membrane was measured. In microfiltration system, the relative flux reduction decreased rapidly to 0.02 in the 30min, as the concentration polarization and gel layer formation were increased. and then the sericin concentration rejection ratio was 40%. In ultrafiltration system, the permeate flux decreased with time and concentration, and increased with the operating pressure and flow rate. Optimal condition in PS100 membrane system for sericin concentration was operating pressure 1.464kgf/$cm^24, operating flow rate $7\ell/min at\; 40^{\circ}C$. At that time, sericin concentration rejection ratio was 83% respectably. The sericin solution was concentrated from 0.1wt% solution to 0.2 wt % solution during about 2 hrs by the UF filteration membrane system.