• Title/Summary/Keyword: Flow Model

Search Result 12,956, Processing Time 0.045 seconds

Acute Cerebral Infarction in a Rabbit Model: Perfusion and Diffusion MR Imaging (가토의 급성 뇌경색에서 관류 및 확산강조 자기공명영상)

  • Heo Suk-Hee;Yim Nam-Yeol;Jeong Gwang-Woo;Yoon Woong;Kim Yun-Hyeon;Jeong Young-Yeon;Chung Tae-Woong;Kim Jeong;Park Jin-Gyoon;Kang Heoung-Keun;Seo Jeong-Jin
    • Investigative Magnetic Resonance Imaging
    • /
    • v.7 no.2
    • /
    • pp.116-123
    • /
    • 2003
  • Purpose : The present study was undertaken to evaluate the usefulness of cerebral diffusion (DWI) and perfusion MR imaging (PWI) in rabbit models with hyperacute cerebral ischemic infarction. Materials and Methods : Experimental cerebral infarction were induced by direct injection of mixture of Histoacryl glue, lipiodol, and tungsten powder into the internal cerebral artery of 6 New-Zealand white rabbits, and they underwent conventional T1 and T2 weighted MR imaging, DWI, and PWI within 1 hour after the occlusion of internal cerebral artery. The PWI scan for each rabbit was obtained at the level of lateral ventricle and 1cm cranial to the basal ganglia. By postprocessing using special imaging software, perfusion images including cerebral blood volume (CBV), cerebral blood flow (CBF), and mean transit time (MTT) maps were obtained. The detection of infarcted lesion were evaluated on both perfusion maps and DWI. MTT difference time were measured in the perfusion defect lesion and symmetric contralateral normal cerebral hemisphere. Results : In all rabbits, there was no abnormal signal intensity on T2WI. But on DWI, abnormal high signal intensity, suggesting cerebral infarction, were detected in all rabbits. PWI (rCBV, CBF and MTT map) also showed perfusion defect in all rabbits. In four rabbits, the calculated square of perfusion defect in MTT map is larger than that of CBF map and in two rabbits, the calculated size of perfusion defect in MTT map and CBF map is same. Any rabbits do not show larger perfusion defect on CBF map than MTT map. In comparison between CBF map and DWI, 3 rabbits show larger square of lesion on CBF map than on DWI. The others shows same square of lesion on both technique. The size of lesion shown in 6 MTT map were larger than DWI. In three cases, the size of lesion shown in CBF map is equal to DWI. But these were smaller than MTT map. The calculated square of lesion in CBF map, equal to that of DWI and smaller than MTT map was three. And in one case, the calculated square of perfusion defect in MTT map was largest, and that of DWI was smallest. Conclusion : DWI and PWI may be useful in diagnosing hyperacute cerebral ischemic infarction and in e-valuating the cerebral hemodynamics in the rabbits.

  • PDF

Effects of Water Temperature and Salinity on the Oxygen Consumption Rate of Juvenile Spotted Sea Bass, Lateolabrax maculatus (점농어, Lateolabrax maculatus 치어의 산소 소비율에 미치는 수온과 염분의 영향)

  • Oh, Sung-Yong;Shin, Chang Hoon;Jo, Jae-Yoon;Noh, Choong Hwan;Myoung, Jung-Goo;Kim, Jong-Man
    • Korean Journal of Ichthyology
    • /
    • v.18 no.3
    • /
    • pp.202-208
    • /
    • 2006
  • An experiment was conducted to investigate the effects of three water temperatures (15, 20 and $25^{\circ}C$) in combination with three salinities (0, 15 and 30 psu) on the oxygen consumption rate of juvenile spotted sea bass, Lateolabrax maculatus (mean body weight $5.5{\pm}0.3g$). The oxygen consumption rates of L. maculatus were measured in triplicate for 24 hours using a continuous flow-through respirometer. Water temperature resulted in significant differences in the mean oxygen consumption rate of L. maculatus (p<0.001), but salinity and combinations of salinity and water temperature did not have (p>0.05). The oxygen consumption increased with increasing water temperatures in all experimental salinity regimes (p<001). Mean oxygen consumption rates at 15, 20 and $25^{\circ}C$ ranged 328.8~342.3, 433.9~441.0 and 651.5~659.9 mg $O_2\;kg^{-1}\;h^{-1}$, respectively. $Q_{10}$ values did not vary with salinity, bud varied with water temperature. $Q_{10}$ values ranged 1.63~1.75 between 15 and $20^{\circ}C$, 2.24~2.26 between 20 and $25^{\circ}C$, and 1.92~1.98 over the full temperature range. The energy loss by metabolic cost increased with increasing water temperatures in all experimental salinity regimes (p<0.001) Mean energy loss rates at 15, 20 and $25^{\circ}C$ ranged 224.6~233.8, 296.3~301.2 and $444.9{\sim}450.7kJ\;kg^{-1}\;d^{-1}$, respectively. These data suggest that the culture of juvenile spotted sea bass is possible without energy loss by salinity difference in freshwater as well as seawater after salinity acclimation. Thus, this result has an application for culture management and bioenergetic model for growth of this species.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2012 (설비공학 분야의 최근 연구 동향 : 2012년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwataik;Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Choi, Jong Min;Park, Jun-Seok;Kim, Sumin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.6
    • /
    • pp.346-361
    • /
    • 2013
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2012. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. The conclusions are as follows : (1) The research works on thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and valves, fuel cells and power plants, ground-coupled heat pumps, and general heat and mass transfer systems. Research issues are mainly focused on new and renewable energy systems, such as fuel cells, ocean thermal energy conversion power plants, and ground-coupled heat pump systems. (2) Research works on the heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer, and industrial heat exchangers. Researches on heat transfer characteristics included the results for natural convection in a square enclosure with two hot circular cylinders, non-uniform grooved tube considering tube expansion, single-tube annular baffle system, broadcasting LED light with ion wind generator, mechanical property and microstructure of SA213 P92 boiler pipe steel, and flat plate using multiple tripping wires. In the area of pool boiling and condensing heat transfer, researches on the design of a micro-channel heat exchanger for a heat pump, numerical simulation of a heat pump evaporator considering the pressure drop in the distributor and capillary tubes, critical heat flux on a thermoexcel-E enhanced surface, and the performance of a fin-and-tube condenser with non-uniform air distribution and different tube types were actively carried out. In the area of industrial heat exchangers, researches on a plate heat exchanger type dehumidifier, fin-tube heat exchanger, an electric circuit transient analogy model in a vertical closed loop ground heat exchanger, heat transfer characteristics of a double skin window for plant factory, a regenerative heat exchanger depending on its porous structure, and various types of plate heat exchangers were performed. (3) In the field of refrigeration, various studies were executed to improve refrigeration system performance, and to evaluate the applicability of alternative refrigerants and new components. Various topics were presented in the area of refrigeration cycle. Research issues mainly focused on the enhancement of the system performance. In the alternative refrigerant area, studies on CO2, R32/R152a mixture, and R1234yf were performed. Studies on the design and performance analysis of various compressors and evaporator were executed. (4) In building mechanical system research fields, twenty-nine studies were conducted to achieve effective design of mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, renewable energy systems, and lighting systems in buildings. New designs and performance tests using numerical methods and experiments provide useful information and key data, which can improve the energy efficiency of buildings. (5) In the fields of the architectural environment, studies for various purposes, such as indoor environment, building energy, and renewable energy were performed. In particular, building energy-related researches and renewable energy systems have been mainly studied, reflecting interests in global climate change, and efforts to reduce building energy consumption by government and architectural specialists. In addition, many researches have been conducted regarding indoor environments.

THE FOREIGN EXCHANGE RATE UNDER RATIONAL EXPECTATION (이성적(理性的) 기대하(期待下)의 환율행태분석(換率行態分析))

  • Yu, Il-Seong
    • The Korean Journal of Financial Management
    • /
    • v.6 no.1
    • /
    • pp.31-62
    • /
    • 1989
  • By using deterministic dynamic models, we observe the behavior of the foreign exchange rate of a small open economy with rational expectation formation and different restrictions on the international economic integrations. First, an economy connected to the world by purchasing power parity and uncovered interest parity is studied in the next section. In both sections, financial assets available in the economy are domestic money and bonds. Stocks are added as a financial instrument in the next section, and real capital accumulation is also taken into account. Furthermore, the economy concerned there is fairly autonomous, and not directly governed by either purchasing power parity or uncovered interest parity. The expectation formation used throughout the whole paper is complete perfect foresight, which is the certainty version of rational expectation and free from any forecast errors. It is found that upon monetary expansion the short run depreciation of the foreign exchange rate is a fairly robust result regardless of the degree of the international economic integration, while it is not true for fiscal expansion. The expectation on the long run state significantly affects the short run response of the exchange rate. All of our models postulate that the current account should be balanced eventually. As the result, the short run behavior of the exchange rate is affected by the expectation on the long run balance and may well be a blend of the traditional flow view and modem asset view. The initial overshooting of the exchange rate is easily observed even in the fairly autonomous economy Furthermore, the initial overshooting is not reduced over time, but augmented for some time before it is eventually eliminated. As long as we maintain rational expectaion, introducing time delay in the adjustment of the foreign goods price to the foreign exchange rate does not make much difference.

  • PDF

A Numerical Study for Effective Operation of MSW Incinerator for Waste of High Heating Value by the Addition of Moisture Air (함습공기를 이용한 고발열량 도시폐기물 소각로의 효율적 운전을 위한 수치 해석적 연구)

  • Shin, Mi-Soo;Shin, Na-Ra;Jang, Dong-Soon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.2
    • /
    • pp.115-123
    • /
    • 2013
  • Stoker type incinerator is one of the most popular one used as municipal solid waste (MSW) incineration because, in general, it is quite suitable for large capacity and need no preprocessing facility. Nowadays, however, since the combustible portion of incoming MSW increases together with the decrease of the moisture content due to prohibition of directly burying food waste in landfill, the heating value of waste is remarkably increasing in comparison with the early stage of incinerator installation. Consequently, the increased heating value in incinerator operation causes a number of serious problems such as reduction of waste amount to be burned due to the boiler heat capacity together with the significant NO generation in high temperature environment. Therefore, in this study, a series of numerical simulation have been made as parameters of waste amount and the fraction of moisture in air stream in order to investigate optimal operating condition for the resolution of the problems associated with the high heating value of waste mentioned above. In specific, a detailed turbulent reaction flow field calculation with NO model was made for the full scale incinerator of D city. To this end, the injection method of moisturized air as oxidizer was intensively reviewed by the addition of moisture water amount from 10% and 20%. The calculation result, in general, showed that the reduction of maximum flame temperature appears consistently due to the combined effects of the increased specific heat of combustion air and vaporization heat by the addition of water moisture. As a consequence, the generation of NOx concentration was substantially reduced. Further, for the case of 20% moisture amount stream, the afterburner region is quite appropriate in temperature range for the operation of SNCR. This suggests the SNCR facility can be considered for reoperation. which is not in service at all due to the increased heating value of MSW.

The Case on Valuation of IT Enterprise (IT 기업의 가치평가 사례연구)

  • Lee, Jae-Il;Yang, Hae-Sul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.4
    • /
    • pp.881-893
    • /
    • 2007
  • IT(Information Technology)-based industries have caused a recent digital revolution and the appearance of various types' information service, being largely expanded toward info-communication device company, info-communication service company, software company etc.. Therefore, the needs to evaluate the company value of IT business for M&A or liquidation are growing tremendously. Unlike other industries, however, IT industry has a short lift cycle and so it doesn't have not only a company value-evaluating model for general businesses but the objective one for IT companies yet. So, this thesis analyzes various value-evaluating technique and newly rising ROV. DCF, the change method of company's cash flow including tangible assets into future value, had been applied during the past industrialization economy era and has been persuasively applied to the present. However, the DCF valuation has no option but to make many mistakes because IT companies have more intangible assets than tangible assets. Accordingly, it is ROV, recognized as the new method of evaluating companies' various options normally and quantitatively, that is brought up recently. But the evaluation on the companies' various options is too subjective and theoretical up to now and due to the lack of objective ground and options, it's not possible to be applied to reality. In this thesis, it is found that ROV is more accurate than DCF, comparing DCF and ROV through four examples. As the options applied to ROV are excessively limited, we tried to develop ROV into a new method by deriving five invisible value factors within IT companies. Therefore, on this occasion, we should set up the basic valuation methods on IT companies and should research and develop an effective and various valuation methods suitable to each company like an internet-based company, a S/W developing enterprise, a network-related company among IT companies.

  • PDF

The Comparison of Protective Effects of Adenosine Included Cardioplegia According to Adenosine Dosage (심정지액 속에 포함된 아데노신의 용량에 따른 심근보호 효과 비교)

  • 유경종;강면식;이교준;임상현;박한기;김종훈;조범구
    • Journal of Chest Surgery
    • /
    • v.31 no.9
    • /
    • pp.837-844
    • /
    • 1998
  • Background: Adenosine is secreted by myocardial cells during myocardial ischemia or hypoxia. It has many beneficial effects on arrhythmias, myocardial ischemia, and reperfusion ischemia. Although many investigators have demonstrated that cardioplegia that includes adenosine shows protective effects in myocardial ischemia or reperfusion injury, reports of the optimal dose of adenosine in cardioplegic solutions vary. We reported the results of beneficial effects of single dosage(0.75 mg/Kg/min) adenosine by use of self-made Langendorff system. But it is uncertain that dosage was optimal. The objective of this study is to determine the optimal dose of adenosine in cardioplegic solutions. Material and Method: We used a self-made Langendorff system to evaluate the myocardial protective effect. Isolated rat hearts were subjected to 90 minutes of deep hypothermic arrest(15$^{\circ}C$) with modified St. Thomas' Hospital cardioplegia including adenosine. Myocardial adenosine levels were augmented during ischemia by providing exogenous adenosine in the cardioplegia. Three groups of hearts were studied: (1) group 1 (n=10) : adenosine - 0.5 mg/Kg/min, (2) group 2(n=10): adenosine -0.75 mg/Kg/min, (3) group 3 (n=10) : adenosine -1 mg/Kg/min. Result: Group 3 resulted in a significantly rapid arrest time of the heart beat(p<0.05) but significantly slow recovery time of the heart beat after reperfusion(p<0.05) compared to groups 1 and 2. Group 2 showed a better percentage of recovery(p<0.05) in systolic aortic pressure, aortic overflow volume, coronary flow volume, and cardiac output compared to groups 1 and 3. Group 1 showed a a better percentage of recovery(p<0.05) in the heart rate compared to the others. In biochemical study of drained reperfusates, CPK and lactic acid levels did not show significant differences in all of the groups. Conclusion: We concluded that group 2 [adenosine(0.75 mg/Kg/min) added to cardioplegia] has better recovery effects after reperfusion in myocardial ischemia and is the most appropriate dosage compared to group 1 and 3.

  • PDF

Optimization of Protocol for Injection of Iodinated Contrast Medium in Pediatric Thoracic CT Examination (소아 흉부 CT검사에서 조영제 주입에 관한 프로토콜의 최적화)

  • Kim, Yung-Kyoon;Kim, Yon-Min
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.6
    • /
    • pp.879-887
    • /
    • 2019
  • The purpose of this study is to establish a physiological injection protocol according to body weight, in order to minimize amount of contrast medium and optimize contrast enhancement in pediatric patients performing thoracic CT examinations. The 80 pediatric patients under the age of 10 were studied. Intravenous contrast material containing 300 mgI/ml was used. The group A injected with a capacity of 1.5 times its weight, and groups B, C and D added 5 to 15 ml of normal saline with a 10% decrease in each. The physiologic model which can be calculated by weight about amount of injection of contrast medium and normal saline, flow rate and delay time were applied. To assess image quality, measured average HU value and SNR of superior vena cava, pulmonary artery, ascending and descending aorta, right and left atrium, right and left ventricle. CT numbers of subclavian vein and superior vena cava were compared to identify the effects of reducing artifacts due to normal saline. Comparing SNR according to the contrast medium injection protocol, significant differences were found in superior vena cava and pulmonary artery, descending aorta, right and left ventricle, and CT numbers showed significant differences in all organs. In particular, B group with a 10% decrease in contrast medium and an additional injection of saline showed a low degree of contrast enhancement in groups with a decrease of more than 20%. In addition, the group injected with normal saline greatly reduced contrast enhancement of subclavian vein and superior vena cava, and the beam hardening artifact by contrast medium was significantly attenuated. In conclusion, the application of physiological protocol for injection of contrast medium in pediatric thoracic CT examinations was able to reduce artifacts by contrast medium, prevent unnecessary use of contrast medium and improve the effect of contrast enhancement.

Effect of a frontal impermeable layer on the excess slurry pressure during the shield tunnelling in the saturated sand (포화 사질토에서 전방 차수층이 쉴드터널 초과 이수압에 미치는영향)

  • Lee, Yong-Jun;Lee, Sang-Duk
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.13 no.4
    • /
    • pp.347-370
    • /
    • 2011
  • Slurry type shield would be very effective for the tunnelling in a sandy ground, when the slurry pressure would be properly adjusted. Low slurry pressure could cause a tunnel face failure or a ground settlement in front of the tunnel face. Thus, the stability of tunnel face could be maintained by applying an excess slurry pressure that is larger than the active earth pressure. However, the slurry pressure should increase properly because an excessively high slurry pressure could cause the slurry flow out or the passive failure of the frontal ground. It is possible to apply the high slurry pressure without passive failure if a horizontal impermeable layer is located in the ground in front of the tunnel face, but its location, size, and effects are not clearly known yet. In this research, two-dimensional model tests were carried out in order to find out the effect of a horizontal impermeable layer for the slurry shield tunnelling in a saturated sandy ground. In tests slurry pressure was increased until the slurry flowed out of the ground surface or the ground fails. Location and dimension of the impermeable layer were varied. As results, the maximum and the excess slurry pressure in sandy ground were linearly proportional to the cover depth. Larger slurry pressure could be applied to increase the stability of the tunnel face when the impermeable layer was located in the ground above the crown in front of the tunnel face. The most effective length of the impermeable grouting layer was 1.0 ~ 1.5D, and the location was 1.0D above the crown level. The safety factor could be suggested as the ratio of the maximum slurry pressure to the active earth pressure at the tunnel face. It could also be suggested that the slurry pressure in the magnitude of 3.5 ~4.0 times larger than the active earth pressure at the initial tunnel face could be applied if the impermeable layer was constructed at the optimal location.

How effective has the Wairau River erodible embankment been in removing sediment from the Lower Wairau River?

  • Kyle, Christensen
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.237-237
    • /
    • 2015
  • The district of Marlborough has had more than its share of river management projects over the past 150 years, each one uniquely affecting the geomorphology and flood hazard of the Wairau Plains. A major early project was to block the Opawa distributary channel at Conders Bend. The Opawa distributary channel took a third and more of Wairau River floodwaters and was a major increasing threat to Blenheim. The blocking of the Opawa required the Wairau and Lower Wairau rivers to carry greater flood flows more often. Consequently the Lower Wairau River was breaking out of its stopbanks approximately every seven years. The idea of diverting flood waters at Tuamarina by providing a direct diversion to the sea through the beach ridges was conceptualised back around the 1920s however, limits on resources and machinery meant the mission of excavating this diversion didn't become feasible until the 1960s. In 1964 a 10 m wide pilot channel was cut from the sea to Tuamarina with an initial capacity of $700m^3/s$. It was expected that floods would eventually scour this 'Wairau Diversion' to its design channel width of 150 m. This did take many more years than initially thought but after approximately 50 years with a little mechanical assistance the Wairau Diversion reached an adequate capacity. Using the power of the river to erode the channel out to its design width and depth was a brilliant idea that saved many thousands of dollars in construction costs and it is somewhat ironic that it is that very same concept that is now being used to deal with the aggradation problem that the Wairau Diversion has caused. The introduction of the Wairau Diversion did provide some flood relief to the lower reaches of the river but unfortunately as the Diversion channel was eroding and enlarging the Lower Wairau River was aggrading and reducing in capacity due to its inability to pass its sediment load with reduced flood flows. It is estimated that approximately $2,000,000m^3$ of sediment was deposited on the bed of the Lower Wairau River in the time between the Diversion's introduction in 1964 and 2010, raising the Lower Wairau's bed upwards of 1.5m in some locations. A numerical morphological model (MIKE-11 ST) was used to assess a number of options which led to the decision and resource consent to construct an erodible (fuse plug) bank at the head of the Wairau Diversion to divert more frequent scouring-flows ($+400m^3/s$)down the Lower Wairau River. Full control gates were ruled out on the grounds of expense. The initial construction of the erodible bank followed in late 2009 with the bank's level at the fuse location set to overtop and begin washing out at a combined Wairau flow of $1,400m^3/s$ which avoids berm flooding in the Lower Wairau. In the three years since the erodible bank was first constructed the Wairau River has sustained 14 events with recorded flows at Tuamarina above $1,000m^3/s$ and three of events in excess of $2,500m^3/s$. These freshes and floods have resulted in washout and rebuild of the erodible bank eight times with a combined rebuild expenditure of $80,000. Marlborough District Council's Rivers & Drainage Department maintains a regular monitoring program for the bed of the Lower Wairau River, which consists of recurrently surveying a series of standard cross sections and estimating the mean bed level (MBL) at each section as well as an overall MBL change over time. A survey was carried out just prior to the installation of the erodible bank and another survey was carried out earlier this year. The results from this latest survey show for the first time since construction of the Wairau Diversion the Lower Wairau River is enlarging. It is estimated that the entire bed of the Lower Wairau has eroded down by an overall average of 60 mm since the introduction of the erodible bank which equates to a total volume of $260,000m^3$. At a cost of $$0.30/m^3$ this represents excellent value compared to mechanical dredging which would likely be in excess of $$10/m^3$. This confirms that the idea of using the river to enlarge the channel is again working for the Wairau River system and that in time nature's "excavator" will provide a channel capacity that will continue to meet design requirements.

  • PDF