• Title/Summary/Keyword: Flow Measuring

Search Result 1,317, Processing Time 0.029 seconds

Characteristics of Droplet Properties in the Two-Phase Spray into a Subsonic Cross Flow

  • Lee, I.C.;Cho, W.J.;Koo, J.Y.
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.03a
    • /
    • pp.358-363
    • /
    • 2008
  • The spray cross-section characteristics of two-phase spray that using external-mixing nozzle injected into a subsonic cross flow were experimentally studied with various ALR ratio that is $0{\sim}59.4%$. Suction type wind tunnel was used and experiments were conducted to ambient environment. Several plain orifice nozzles with L/d of 30 and orifice diameter of 0.5 mm and orifice length 1.5 mm were tested. Free stream velocity profiles at the injection location were measured using hot wire. Spray images were captured to study collision point and column trajectory. Phase Doppler particle analyzer(PDPA) was utilized to quantitatively measuring droplet SMD, volume flux. Measuring probe of PDPA positions was moved 3-way transverse machine. SMD distributions were layered structure and peaked at the top of the spray plume and low value at bottom of the spray. Volume flux of spray was distributed to the two side region and volume flux quantity decreased when ALR ratio increased. It was found that the perpendicularly injected two-phase spray jet of external mixing into a cross flow showing that mistlike spray moved away from the test section bottom region.

  • PDF

Unsteady Nature of a Tip Leakage Vortex in an Axial Flow Fan (축류팬 익단누설와류의 비정상 특성)

  • Jang, Choon-Man;Kim, Kwang-Yong
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.845-850
    • /
    • 2003
  • Unsteady nature of a tip leakage vortex in an axial flow fan operating at a design and off-design operating conditions has been investigated by measuring the velocity fluctuation in a blade passage with a rotating hotwire probe sensor. Two hot-wire probe sensors rotating with the fan rotor were also introduced to obtain the cross-correlation coefficient between the two sensors located in the vortical flow as well as the fluctuating velocity. The results show that the vortical flow structure near the rotor tip can be clearly observed at the quasi-orthogonal planes to a tip leakage vortex. The leakage vortex is enlarged as the flow rate is decreased, thus resulting in the high blockage to main flow. The spectral peaks due to the fluctuating velocity near the rotor tip are mainly observed in the reverse flow region at higher flow rates than the peak pressure operating condition. However, no peak frequency presents near the rotor tip for near stall condition.

  • PDF

Measure Correlation Analysis of Network Flow Based On Symmetric Uncertainty

  • Dong, Shi;Ding, Wei;Chen, Liang
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.6 no.6
    • /
    • pp.1649-1667
    • /
    • 2012
  • In order to improve the accuracy and universality of the flow metric correlation analysis, this paper firstly analyzes the characteristics of Internet flow metrics as random variables, points out the disadvantages of Pearson Correlation Coefficient which is used to measure the correlation between two flow metrics by current researches. Then a method based on Symmetrical Uncertainty is proposed to measure the correlation between two flow metrics, and is extended to measure the correlation among multi-variables. Meanwhile, the simulation and polynomial fitting method are used to reveal the threshold value between different correlation degrees for SU method. The statistical analysis results on the common flow metrics using several traces show that Symmetrical Uncertainty can not only represent the correct aspects of Pearson Correlation Coefficient, but also make up for its shortcomings, thus achieve the purpose of measuring flow metric correlation quantitatively and accurately. On the other hand, reveal the actual relationship among fourteen common flow metrics.

The Effect of Flow Patterns with Polymer Additivies From Two Phase Flow at Vertical up Ward in Circular Tube (원관내 수직상향 2상유동에서 고분자물질이 유동양식에 미치는 영향)

  • 김재근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.22 no.4
    • /
    • pp.505-514
    • /
    • 1998
  • Flow pattern of air-water two phase flow depends on the conditions of pressure void fraction and channel geometry. We classify the flow pattern by measuring the output signal of the conductivity probe. under the classified flow pattern we mount a visualization equipment on the test section and take pictures. We vary the concentration of pure solvent and polymer to measure local void fraction. We know that the maximum point position of local void fraction distribution move from the center of the pipe to the wall of the pipe as JSL increase when JSA is constant in two phase flow. But we find that the maximum point position of local void friction move from the wal of the pipe to the center of the pipe when polymer concentration increase.

  • PDF

Determination of Flow Direction by Using an Acousto-Optic Effect (광음향 변조효과를 이용한 유체의 방향 결정)

  • 김규욱
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1990.02a
    • /
    • pp.34-36
    • /
    • 1990
  • The flow direction in a glass tube is measured by using a forward scatering dual beam laser Doppler velocimeter with an acousto-optic modulator. We can determine the flow direction by measuring the shifted Doppler frequency which is dependent on the order of modulation of the laser frequency shifting moves only the Doppler signal, enabling complete separation of the Pedestal and Doppler singal.

  • PDF

Real-time Hydrologic Monitoring at Agricultural Small Watershed (실시간 계측기기를 이용한 농업소유역의 수문모니터링)

  • Seong, Choung-Hyun;Park, Seung-Woo;Kim, Sang-Min;Choi, Ja-Yoon
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.253-256
    • /
    • 2002
  • A hydrologic gauging network include a real-time measuring equipment was established within the Balhan watershed. Rainfall, stream water level, flow velocities were monitored at the six gauging stations. For stream flow gauging stations, the stage-discharge relationships were developed. The flow rate of the Balan watershed was 83.60% in 2001 and 48.79% in 2002.

  • PDF

Pressure Ripple Characteristics of Hydrostatic Transmission (HST) (유압전동장치(HST)의 압력맥동 특성)

  • 김도태
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.222-227
    • /
    • 1998
  • The paper proposes a new method for measuring the flow ripple generated by an axial piston pump and motor in a hydrostatic transmission. The method is based on dynamic characteristics between pressure and flow ripple in the pipeline. Also, the self-checking functions develop for the evaluation of accuracy and dynamic response of estimated results by the method proposed here. The experiment carry out open circuit type hydrostatic transmission. By using the self-checking functions, the validity of the method is investigated by comparison with the measured and estimated flow and pressure ripples, and good agreement is achieved.

  • PDF

A Program Complexity Measure using the Slice-based Information Flow Graph(SIFG) (SIFG를 이용한 프로그램 복잡도 척도)

  • Choi, Wan-Kyoo;Chung, Il-Yong;Lee, Sung-Joo
    • Journal of KIISE:Software and Applications
    • /
    • v.28 no.12
    • /
    • pp.910-920
    • /
    • 2001
  • We developed a SIFC(Slice-based Information Flow Graph) For modeling the information flow on program on the basis of the information flow of a data tokens on program slices. Then we defined a SCM(Slice-based Complexity Measure) for measuring the program complexity by measuring the complexity of information flow on SIFG, We showed that, according to Zuse's approach, it assumed ordinal scale based on atomic modifications on SIFG and that it was additive to binary operation MBSEQ and that it was not additive to binary operation MBALT but satisfied Weyuker's 9th axiom. Also based on comparison with the existing measures, we showed that SCM could measure not only the control and data flow in program but also the physical size of program.

  • PDF

Micro-computed tomographic evaluation of the flow and filling ability of endodontic materials using different test models

  • Torres, Fernanda Ferrari Esteves;Guerreiro-Tanomaru, Juliane Maria;Chavez-Andrade, Gisselle Moraima;Pinto, Jader Camilo;Berbert, Fabio Luiz Camargo Villela;Tanomaru-Filho, Mario
    • Restorative Dentistry and Endodontics
    • /
    • v.45 no.2
    • /
    • pp.11.1-11.9
    • /
    • 2020
  • Objectives: This study compared the flow and filling of several retrograde filling materials using new different test models. Materials and Methods: Glass plates were manufactured with a central cavity and 4 grooves in the horizontal and vertical directions. Grooves with the dimensions used in the previous study (1 × 1 × 2 mm; length, width, and height respectively) were compared with grooves measuring 1 × 1 × 1 and 1 × 2 × 1 mm. Biodentine, intermediate restorative material (IRM), and mineral trioxide aggregate (MTA) were evaluated. Each material was placed in the central cavity, and then another glass plate and a metal weight were placed over the cement. The glass plate/material set was scanned using micro-computed tomography. Flow was calculated by linear measurements in the grooves. Central filling was calculated in the central cavity (㎣) and lateral filling was measured up to 2 mm from the central cavity. Results: Biodentine presented the least flow and better filling than IRM when evaluated in the 1 × 1 × 2 model. In a comparison of the test models, MTA had the most flow in the 1 × 1 × 2 model. All materials had lower lateral filling when the 1 × 1 × 2 model was used. Conclusions: Flow and filling were affected by the size of the test models. Higher grooves and materials with greater flow resulted in lower filling capacity. The test model measuring 1 × 1 × 2 mm showed a better ability to differentiate among the materials.

THE EFFECT OF VISCOSITY, SPECIMEN GEOMETRY AND ADHESION ON THE LINEAR POLYMERIZATION SHRINKAGE MEASUREMENT OF LIGHT CURED COMPOSITES (점도, 시편형태 그리고 접착의 유무가 광중합 복합레진의 선형중합수축의 측정에 미치는 영향)

  • Lee, In-Bog;Son, Ho-Hyun;Kwon, Hyuk-Chun;Um, Chung-Moon;Cho, Byeong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.6
    • /
    • pp.457-466
    • /
    • 2003
  • The aim of study was to investigate the effect of flow, specimen geometry and adhesion on the measurement of linear polymerization shrinkage of light cured composite resins using linear shrinkage measuring device. Four commercially available composites - an anterior posterior hybrid composite Z100, a posterior packable composite P60 and two flowable composites, Filtek flow and Tetric flow-were studied. The linear polymerization shrinkage of composites was determined using 'bonded disc method' and 'non-bond-ed' free shrinkage method at varying C-factor in the range of 1∼8 by changing specimen geometry. These measured linear shrinkage values were compared with free volumetric shrinkage values. The viscosity and flow of composites were determined and compared by measuring the dropping speed of metal rod under constant load. In non-bonded method, the linear shrinkage approximated one third of true volumetric shrink-age by isotropic contraction. However, in bonded disc method, as the bonded surface increased the linear shrinkage increased up to volumetric shrinkage value by anisotropic contraction. The linear shrinkage value increased with increasing C-factor and approximated true volumetric shrinkage and reached plateau at about C-factor 5∼6. The more flow the composite was, reduced linear shrinkage was measured by compensation radial flow.