• 제목/요약/키워드: Flow Force

검색결과 2,352건 처리시간 0.028초

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

양상선(楊上善)의 삼음삼양(三陰三陽) 학설(學說)에 대한 연구 - 음양속성(陰陽屬性), 관합추(關闔樞), 기혈다소(氣血多少)를 중심으로 - (A Study of Yangshangsun(楊上善)'s theory of three-yum and three-yang(三陰三陽) - focus on attribute of three-yum and three-yang(三陰三陽), the bolt-leaf-hanges(關闔樞) theory, large of small of gi-blood(氣血多少))

  • 이용범
    • 대한한의학원전학회지
    • /
    • 제10권
    • /
    • pp.450-493
    • /
    • 1997
  • Three-yum and three-yang(三陰三陽) is the change state of yum-yang(陰陽) which is caused by six gi(六氣). They mean the flow of six gi(六氣) which exist throughout the viscera, the channel(經絡), and the skin. But it is not easy to understand the meaning because the contents of the attribute of three-yum and three-yang(三陰三陽), the bolt-leaf-hanges(關闔樞) theory and large or small of gi-blood(氣血多少) which is the main clue that explain it in ${\ll}$Somun(素問)${\gg}$ and ${\ll}$Yeongchu(靈樞)${\gg}$ don't coincide with each other. I, the writer, tried to understand the uncertain meaning and the contents which are written about three points above differently in each of the books that are ${\ll}$Somun(素問)${\gg}$ and ${\ll}$Yeongchu(靈樞)${\gg}$. So, from that the course that the book, ${\ll}$Huangjenegeong(黃帝內經)${\gg}$ is handed down is so relatively simple in a wood block-printed book, that the ${\ll}$Huangjenegeongtaeso(黃帝內經太素)${\gg}$ has less wong-words than the Somun(素問) and the Yeongchu(靈樞), and from that Yangshangsun(楊上善) wrote the note in the ${\ll}$Huangjenegeongtaeso(黃帝內經太素)${\gg}$ by royal order about 100 years former than Wangbing(王氷), as making projects of Yangshangsun(楊上善)'s note and the original of the ${\ll}$Huangjenegeongtaeso(黃帝內經太素)${\gg}$ which has relation to the yum-yang(陰陽) attribute of three-yum and three-yang(三陰三陽), the bolt-leaf-hanges(關闔樞) theory, and the large or small of gi-blood(氣血多少) and researching the Yangshangsun(楊上善)'s theory. The result is summarized like this. First, wherease the order of the change of three-yum and three-yang(三陰三陽) which is explained by Yangshangsun(楊上善) consider the change of yangi(陽氣) in body most important, the order of the change gaeggi(客氣)'s three-yum and three-yang(三陰三陽) considers chungi(天氣) most important, and the order of jugi(主氣)'s three-yum and three-yang(三陰三陽) considers jigi(地氣)'s change of ohaeng(五行) most important. If the order of change three-yum and three-yang(三陰三陽) in the ${\ll}$Huangjenegeongtaeso(黃帝內經太素)${\gg}$ is considered, each of taeyang(太陽) and soyum(少陰) are expressed as the base of yum-yang(陰陽) and yangmeong(陽明) and taeyum(太陰) are expressed as the palmy days of yum-yang(陰陽), soyang(少陽) and gyolyum(厥陰) are expressed as pacemaker(樞杻) which controls the change of yum-yang(陰陽). Thus, each has something in common that is fettered by the inside and outside. In the flow of channel(經絡), taeyang(太陽) and soyum(少陰) take charge of the behind of body, yangmeong(陽明) and taeyum(太陰) take charge of the front of body and soyang(少陽) and gyolyum(厥陰) take of the side of body. Second, in Yangshangsun(楊上善)'s bolt-leaf-hanges(關闔樞) theory, three-yum(三陰) is regarded as inside, three-yang(三陽) as outside, so when bolt, leaf and hanges fulfil their duties in inside and outside, the life(life force) is thought to be revealed normally. It is impossible to understand the bolt-leaf-hanges with the conception of the inside and outside which divide three-yum and three-yang(三陰三陽) into taeyang-soyum(太陽-少陰), yangmeong-taeyum(陽明-太陰), soyang-gyolyum(少陽-厥陰) according to yum-yang(陰陽) attribute, hence it need the special conception that is taeyang(太陽)-taeyum(太陰), yangmeong(陽明)-gyolyum(厥陰), soyang(少陽)-soyum(少陰) which center on their duties in inside and outside. In the denunciation of the word open(開) and bolt(關), because Yangshangsun(楊上善) said that the duities of taeyang(太陽) and taeyum(太陰) are shutter(閉禁), bolt(關) is coincided with that significance. Third, with explaining the large or small of gi-blood(氣血多少) of three-yum and three-yang(三陰三陽), Yangshangsun(楊上善) expressed the inside and outside either in the same way or differently. Because the inside and outside is interior of body and exterior of body, it is the explanation that is noticed by the fact that the property of large or small of gi-blood(氣血多少) is either able to be same or different. In this viewpoint, if we unite the contents about large or small of gi-blood(氣血多少) of ${\ll}$Somun(素問)${\gg}$, ${\ll}$Yeongchu(靈樞)${\gg}$, we will find that the descriptions of large or small of gi-blood(氣血多少) of three-yang(三陽) in ${\ll}$Somun(素問)${\gg}$ ${\ll}$Yeongchu(靈樞)${\gg}$ correspond with the ${\ll}$Huangjenegeongtaeso(黃帝內經太素)${\gg}$, but in three-yum(三陰), the contrary presentations exit. The reason is that large or small of gi-blood(氣血多少) of three-yum(三陰) isn't only expressed as che(體) in the point of che-yong(體用), but as a point of yong(用) that is a phenomenon. As researching the original of ${\ll}$Huangjenegeongtaeso(黃帝內經太素)${\gg}$ and Yangshangsun(楊上善)'s notes as a center about three problems that are yum-yang(陰陽) attribute, the bolt-leaf-hanges(關闔樞) and large or small of gi-blood(氣血多少) of three-yum and three-yang(三陰三陽), I, the writer, tried to explain the part which is written differently or has uncertain conception in the book ${\ll}$Somun(素問)${\gg}$ and the book ${\ll}$Yeongchu(靈樞)${\gg}$, but the concrete result of the work like this will be judged according to the question how many theories are correspondent with real presence at a sickbed. Hence, the work to veryfy the theories in the future will be left as assignment.

  • PDF

불규칙파-해저지반-혼성방파제의 상호작용에 의한 지반과 구조물의 동적응답에 관한 수치시뮬레이션 (II) (Numerical Simulation of Dynamic Response of Seabed and Structure due to the Interaction among Seabed, Composite Breakwater and Irregular Waves (II))

  • 이광호;백동진;김도삼;김태형;배기성
    • 한국해안·해양공학회논문집
    • /
    • 제26권3호
    • /
    • pp.174-183
    • /
    • 2014
  • 해양 및 해안구조물 하부의 해저지반에 장시간 지속적인 고파랑이 작용하는 경우 진동성분과 잔류성분으로 구성되는 과잉간극수압의 증가에 따른 유효응력의 감소로 인하여 해저지반내에 액상화의 가능성이 나타나고, 일단 액상화가 발생되면 그의 진행에 따라 구조물의 침하 혹은 전도에 의해 종국적으로 구조물이 파괴될 가능성이 높아지게 된다. 본 연구에서는 2차원수치파동수로를 혼상류해석과 불규칙파동장으로 확장한 수치해석법을 적용하여 불규칙파동장하에서 해저지반상 및 혼성방파제의 표면상에서 시간변동의 동파압과 유속에 의한 전단응력을 산정하고, 그 결과를 지반의 동적거동을 정밀하게 재현할 수 있는 유한요소법에 기초한 탄소성해저지반응답용의 수치해석프로그램에 입력치로 적용하여 불규칙파동장에서 해저지반내에서 과잉간극수압 및 유효응력의 시공간적인 변화, 이로 인한 액상화, 그리고 지반의 시간변형과 케이슨의 시간변위 및 변위가속도 등을 정량적으로 평가한다. 이로부터 혼성 방파제 전면 및 후면 하부의 해저지반내에서 액상화 가능성을 확인할 수 있었고, 이에 따라 액상화된 토립자는 흐름에 대한 저항력을 상실하므로 액상화된 지반은 세굴가능성이 클 것으로 판단된다. 또한, 액상화된 지반은 강도의 현저한 저하로 구조물의 진동변위가 증폭되고, 더불어 혼성방파제의 안정성에 큰 영향을 미칠 것으로 예상된다. 여기서, 본 연구의 전체 내용을 지면관계상 두 부분으로 나누며, 전반부를 (I)로 하여 구조물의 동적변위와 변위가속도 및 지반변형을 중심으로 다루고, 후반부를 (II)로 하여 지반내에서 간극수압의 시간변동, 액상화 및 유효응력경로 등을 상세히 다루며, 본 연구는 후반부인 (II)에 해당한다.

불규칙파-해저지반-혼성방파제의 상호작용에 의한 지반과 구조물의 동적응답에 관한 수치시뮬레이션 (I) (Numerical Simulation of Dynamic Response of Seabed and Structure due to the Interaction among Seabed, Composite Breakwater and Irregular Waves (I))

  • 이광호;백동진;김도삼;김태형;배기성
    • 한국해안·해양공학회논문집
    • /
    • 제26권3호
    • /
    • pp.160-173
    • /
    • 2014
  • 해양 및 해안구조물 하부의 해저지반에 장시간 지속적인 고파랑이 작용하는 경우 진동성분과 잔류성분으로 구성되는 과잉간극수압의 증가에 따른 유효응력의 감소로 인하여 해저지반내에 액상화의 가능성이 나타나고, 일단 액상화가 발생되면 그의 진행에 따라 구조물의 침하 혹은 전도에 의해 종국적으로 구조물이 파괴될 가능성이 높아지게 된다. 본 연구에서는 2차원수치파동수로를 혼상류해석과 불규칙파동장으로 확장한 수치해석법을 적용하여 불규칙파동장하에서 해저지반상 및 혼성방파제의 표면상에서 시간변동의 동파압과 유속에 의한 전단응력을 산정하고, 그 결과를 지반의 동적거동을 정밀하게 재현할 수 있는 유한요소법에 기초한 탄소성해저지반응답용의 수치해석프로그램에 입력치로 적용하여 불규칙파동장에서 해저지반내에서 과잉간극수압 및 유효응력의 시공간적인 변화, 이로 인한 액상화, 그리고 지반의 시간변형과 케이슨의 시간변위 및 변위가속도 등을 정량적으로 평가한다. 이로부터 혼성방파제 전면 및 후면 하부의 해저지반내에서 액상화 가능성을 확인할 수 있었고, 이에 따라 액상화된 토립자는 흐름에 대한 저항력을 상실하므로 액상화된 지반은 세굴가능성이 클 것으로 판단된다. 또한, 액상화된 지반은 강도의 현저한 저하로 구조물의 진동변위가 증폭되고, 더불어 혼성방파제의 안정성에 큰 영향을 미칠 것으로 예상된다. 여기서, 본 연구의 전체 내용을 지면관계상 두 부분으로 나누며, 전반부를 (I)로 하여 구조물의 동적변위와 변위가속도 및 지반변형을 중심으로 다루고, 후반부를 (II)로 하여 지반내에서 간극수압의 시간변동, 액상화 및 유효응력경로 등을 상세히 다루며, 본 연구는 전반부인 (I)에 해당한다.

Hydrocyclone Filter 장치를 이용한 강우유출수내 미세입자 제거특성 분석 (Performance Evaluation of Hydrocyclone Filter for Treatment of Micro Particles in Storm Runoff)

  • 이준호;방기웅;홍성철
    • 대한환경공학회지
    • /
    • 제31권11호
    • /
    • pp.1007-1018
    • /
    • 2009
  • Hydrocyclone은 높은 수면적부하율 운전이 가능하고, 구동부분이 없고, 운전 및 유지관리비가 적게 소요되어 미세입자물질제거에 효과적인 장치로 다양한 산업 분야에서 활용되고 있다. Hydrocyclone에 나선형 유입부를 통해 직각으로 유입되어 중력이 아닌 원심력에 의해 입자물질이 하부배출구로 분리되고 처리수는 vortex finder를 통해 배출된다. 입자분리에 hydrocyclone은 많은 장점을 가지고 있음에도 불구하고 도시지역 강우유출수 처리사례는 드문 실정이다. 본 연구에서는 변형된 hydrocyclone과 perlite 여재를 조합한 hydrocyclone filter (HCF)을 이용하여 강우유출수내 미세입자의 제거능을 분석하였다. 입자물질들은 인공입자들을 이용하여 강우유출수내 입자농도를 모의 실험하였다. 인공입자들을 물에 분산시켜 강우유출수를 재현하였는데 사용한 입자들은 이온교환 수지, 도로측구 퇴적물질, 상업지역 맨홀퇴적물질, 그리고 실리카겔 등이다. 하부배출부와 vortex finder 구조를 달리하여 HCFopen system과 HCF-closed system으로 구분하여 처리능을 분석하였다. HCF장치는 아크릴 수지를 이용하였는데 hydrocyclone의 직경은 120 mm이고 여과조의 직경은 250 mm이고 전체적인 높이는 800 mm로 제작하였다. 운전조건별 유입수 농도와 입경을 다양하게 적용하였고 SS와 COD농도를 분석하여 처리효율을 산정하였다. HCF-open system의 경우 운전 가능한 최대 수면적부하율은 700 $m^3/m^2$/day이었고 HCF-closed system의 경우 수면적부하율 1,200 $m^3/m^2$/day까지이다. HCF-open system 운전결과 HCFclosed system에 비교하여 평균 수면적부하율은 2배 이상 높게 운전이 가능하며 처리효율도 8~20% 이상 향상되는 것으로 분석되었다. 또한 유입수 SS농도가 높을수록 처리효율이 증가하며, 입경이 클수록 수면적부하율의 변화에 대한 처리효율의 영향이 적은 것으로 분석되었다. HCF-closed system의 실험을 통한 수면적부하율 변화에 대한 실리카겔입자의 제거 효율과 CFD입자추적기법을 이용한 예측 처리효율을 비교한 결과 CFD에 예측효율이 실제실험결과와 비교하여 다소 높게 나타나지만 처리효율의 경향은 매우 유사하게 나타나 CFD추적기법을 이용한 HDS유형 처리장치 설계 시 유용한 도구로 활용될 수 있을 것으로 판단된다.

백서 정중구개봉합 확대후의 CGRP 면역반응 신경섬유의 변화 (Changes in CGRP-immunoreactive Nerve Fibers during Expansion of Midpalatal Suture of the Rat)

  • 김보경;박국필;경희문;권오원;성재현
    • 대한치과교정학회지
    • /
    • 제29권1호
    • /
    • pp.73-81
    • /
    • 1999
  • 측방확대장치에 의한 정중구개봉합부의 확대시 교정력은 구개부의 신경요소들에 변화를 일으키면서 동통을 유발하게 되고 구개봉합부가 확대되고 그것이 유지되는 동안에 기계적 자극에 의한 구개부신경섬유의 반응성에 변화를 일으킬 것으로 생각된다. 본 연구에서는 백서 정중구개봉합부의 CGRP 면역반응 신경섬유의 교정력 적용시간에 따른 형태학적인 반응성, 밀도, 분포변화등을 관찰하고 그와 연관된 CGRP의 기능을 알아보고자 250gm내외의 Sprague-Dawley 웅성백서 상악전치에 200gm의 치아이개력이 가해지도록 활성화시킨 helical spring을 삽입하여 정상대조군과 장치 장착후 경과시간에 따라 1일, 4일, 7일, 14일 경과군으로 나누어 정중구개봉합부를 확대후 희생시켜 면역조직화학법으로 염색하여 관찰하였다. ${\cdot}$ 대조군에서 정중구개봉합부 결합조직의 CGRP 면역양성 신경섬유는 거의 관찰되지 않았다. ${\cdot}$1일군에서는 대조군에 비해 CGRP면역반응 신경섬유가 현저한 증가를 보였으며 주로 혈관 주위에 염주알 모양의 가는 신경섬유가 관찰되었다. ${\cdot}$ 4일군에서는 CGRP면역반응 신경섬유가 대조군에 비해서는 현저한 증가를 보였으나 1일군에 비해서는 크게 증가하지 않았으며 혈관의 크기가 훨씬 확장되어 관찰되었다. ${\cdot}$ 7일군에서는 특징적으로 조골양세포가 새로이 형성된 골변연을 따라 줄지어 배열되는 독특한 양상이 관찰되었고 신경섬유의 수는 4일군에 비하여 감소하고 혈관의 직경도 감소되었다. ${\cdot}$14일군에서는 CGRP면역반응 신경섬유가 7일군과 유사한 분포를 보였으며 확대에 의한 골변연의 불규칙성도 대체로 감소되었다. CGRP면역반응 신경섬유는 정중구개봉합의 확대시 초기에 일어나는 신경원성 염증반응에 주로 관련되어 증식되는 것으로 생각된다.

  • PDF

퇴적물내의 산소와 물 수송에 관한 습지 식물의 역할 (Role of Wetland Plants as Oxygen and Water Pump into Benthic Sediments)

  • 최정현;박석순
    • 생태와환경
    • /
    • 제37권4호통권109호
    • /
    • pp.436-447
    • /
    • 2004
  • 습지를 규정하는 주요한 특징의 하나인 습지식물은 장기간의 침수로 인해 혐기성 상태로 존재하는 습지 퇴적물에서 생존을 위한 특별한 적응방법을 발달시켰다. 식물체내에 넓게 분포하고 있는 다공성의 세포는 공기중의 산소를 뿌리로 운반하기 위한 통로로 작용하며, 농도차이에 의한 확산과 압력차이에 의한 대류에 의하여 산소가 운반되어진다. 이러한 식물체 내에서의 산소이동은 식물이 혐기성 퇴적물 속으로 뿌리를 내리고 생존하게 하는 주요한 기작이 된다. 뿌리로 이동되어진 산소는 혐기성 퇴적물로 확산되어져서 뿌리주변의 퇴적물은 산화상태로 변화시키고, 뿌리의 호흡, 미생물의 호흡, 미생물에 의한 유기물 분해반응을 촉진시키게 된다. 또한 습지식물은 생장에 필요한 수분을 뿌리로 흡수하며, 이는 지표수와 퇴적물내 공극수가 뿌리주변으로 이동하게 되는 추진력이 된다. 습지 퇴적물은 식물의 사체에서 기인하는 유기물에 의해 수리학적 전도도가 작아서 퇴적물내 물의 움직임이 미미하나, 식물에 의한 물의 흡수는 퇴적물내 물의 움직임을 촉진시키게 된다. 이러한 식물의 특별한 적응기작은 해부학적, 형태학적, 생리학적으로 많은 연구가 수행되어져 왔으나, 이러한 적응기작들에 퇴적물내 생지화학적 반응에 미치는 영향에 대한 연구는 미비한 수준에 머물러있다. 퇴적물내 생지화학적 반응들은 수체에서 유입된 미량 오염물질의 이동 및 변형과정에 영향을 미치게 되므로 식물의 작용에 의한 생지화학적 반응의 변화들은 미량 오염물질의 거동에 영향을 미치게 되며 나아가 수자원과 수질 생태계에 영향을 초래하게 된다. 따라서 식물의 존재와 성장에 따른 퇴적물내 생지화학적 반응의 변화는 생태학적 환경에서 습지의 중요성을 인식하는데 필요한 연구과제라 사료된다. 난이도, 변별도 등에서 유사하므로 당분간 계속 사용하여도 될 것이다. 따른 변화(變化)는 볼 수 없었다. ATP 첨가(添加)로서는 0.30mM의 농도(濃度)에서 0.15 mM의 농도(濃度)에 비(比)하여 Young 율(率)이 낮았다. 3) 외경동맥(外經動脈)의 종절편(縱切片)의 Young 율(率)은 생리적식염수(生理的食鹽水)에 둔 군(群)에서는 15분(分), 45분(分) 및 75분(分)에서 각각(各各) 2.12, 2.48 및 $2.46{\times}10^7 dyne/cm^2$으로서 실험초기(實驗初期)에 비(比)하여 후기(後期)에서 Young 율(率)이 약간(若干) 높은 경향(傾向)을 나타내었고, 이러한 경향(傾向)은 ATP의 첨가(添加)로서도 비슷하였다.수량(收量)과 자실체형성(子實體形成) 소요일(所要日)의 관점(觀點)에서 보면 C/N율(率) 30.46이 어느정도 적당(適當)한 것 같다. 4. Thiamine $50{\mu}g%,\;KH_2PO_4$ 0.2%, $MgSO_4{\cdot}7H_2O$$0.02{\sim}0.03%$일때 균사(菌絲)와 자실체(子實體) 생육(生育)이 우수(優秀)하였으며 미량원소(微量元素)로서는 $FeSO_4{\cdot}7H_2O$,\;ZnSO_4{\cdot}7H_2O$$MnSO_4{\cdot}5H_2O$가 공존(共存)하면 생육촉진(生育促進)의 상승효과(相乘效果)가 인정되었으나 3이원소(元素)중 Mn이 결핍(缺乏)하면 균사(菌絲)와 자실체(子實體)의 생육(生育)이 다소 저하되었다. 이들 염류(鹽類)의 최적농도(最適濃度)는 각각 0.02mg%이었다. 5.

저산소 상태로 인한 조골세포 고사사기전에서 p-38 MAP kinase의 역할에 관한 연구 (Role of p-38 MAP Kinase in apoptosis of hypoxia-induced osteoblasts)

  • 윤정현;정애진;강경화;김상철
    • 대한치과교정학회지
    • /
    • 제33권3호
    • /
    • pp.169-183
    • /
    • 2003
  • 교정력에 의한 치아 이동은 기계적인 힘에 의하여 압박측에는 다양한 구조를 가진 치주 조직에 혈류의 변화가 생기며 국소적으로 산소 장력에도 변화가 생겨 저산소 상태 가 유발됨은 이미 확인한 바 있다. 본 연구는 치아 주위 골격을 형성하는 조골세포를 대상으로 교정적 치아 이동과 유사한 시험관내 조건을 설정하여 저산소 상태 시 유발되는 조골세포 고사조절 기전을 규명하고자 시행하였다. 생리적인 저산소증의 실험조건으로 $2\%$ 산소상태를 설정하여 저산소 하에서 세포가 고사(apoptosis) 됨을 확인하였고, stress유발 시 많은 관련을 가진 것으로 알려진 p-38 MAPK의 활성을 관찰하였다. 또한 p-38 MAPK의 억제제인 SB203580의 전처치로 인하여 세포의 죽음이 억제됨을 확인하였고, 저산소 상태 시 활성형태로 분절되는 caspase-3, -6및 9등의 세포고사관련 효소들의 활성 형태로의 분절이 억제됨을 확인하였으며 이러한 caspase의 기질인 Lamin-A등의 분절 또한 억제됨을 밝혔다. 또한 마이토콘드리아 내의 cytochrome c의 세포질내로의 이동 또한 조절됨을 확인함으로써 p-38 MAPK의 조절단계를 시사하여 주고 있다. 본 연구로 치아 이동 시 유발되는 저산소 상태 하에서 발생하는 조골세포의 고사 조절에 p-38 MAPK가 관여함을 확인하였다.

저층수 배사관 내 유입된 사석 배출능력에 대한 연구 (A Experimental Study on Exclusion Ability of Riprap into Bypass Pipe)

  • 정석일;이승오
    • 대한토목학회논문집
    • /
    • 제37권1호
    • /
    • pp.239-246
    • /
    • 2017
  • 국내 중소하천의 횡단구조물인 보 또는 낙차공은 대부분 고정식 콘크리트 구조물이며, 저층수의 배제가 쉽지 않다. 횡단구조물로 인해 유사가 퇴적되며, 유사에 흡착한 오염물들이 그대로 하천의 바닥을 오염시키고 있다. 이에 저층수 및 퇴적유사에 대한 관심이 증가하고 있는 실정이며, 이러한 대안의 하나로 횡단구조물 상류와 하류를 하상 아래로 연결시키는 구조물로써, 보 상류 저층의 물 및 유사 배제를 목적으로 저층수배출관을 설치하는 방안이 있다. 그러나 사석이 유입되고, 배제 되지 않을 경우 효율성이 크게 저하될 가능성이 있다. 이에 본 연구에서는 저층수 배출관 내 사석을 배제할 수 있는 능력에 대한 연구를 수행하였다. 사석과 거동이 유사한 유사(sediment)의 한계조건(critical condition) 중 한계전단력(critical shear stress) 유도과정과 달랑베르의 원리(d'Alembert principle)를 응용하여 이동 중인 사석이 배제될 수 있는 조건(${\tau}_c{^*}$)을 유도하였다. 그러나 저층수 배출관 내 유입된 사석은 정지상태가 아닌 이동 중이므로, Lagrangian 기법을 활용하여 수리실험에서 도출된 유속으로 상대속도(relative velocity)를 제시하였다. 수리실험은 축척효과(scale effect)를 최소화하기 위해 폭이 5.0 m이고, 높이가 1.0 m인 광폭 개수로를 제작하였으며, 사용된 사석은 가공된 완전 구형을 사용하였다. 실험 결과 유속과 구형 입자 속도와의 비가 0.5~0.7 사이로 나타났으며, 이러한 결과를 유도된 식에 적용하여, 최종적으로 사석이 배제되는 조건을 도출하게 되었다. 구간은 입자레이놀즈수($Re_p$)와 무차원 한계 전단력(${\tau}_c{^*}$)에 따라 크게 3가지로 구분되었다. 배제 구간(exclusion section), 확률적 배제 구간(probabilistic exclusion section), 비배제 구간(no exclusion section)이다. 본 연구결과는 횡단구조물의 저층수 배출관 설계시 유용한 기초 정보를 제공할 수 있을 것이다.