• 제목/요약/키워드: Flow Flux

검색결과 1,677건 처리시간 0.032초

Applicability of One-Dimensional Mechanistic Post-Dryout Prediction Model

  • Jeong, Hae-Yong;No, Hee-Cheon
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 춘계학술발표회논문집(2)
    • /
    • pp.586-591
    • /
    • 1996
  • Through the analysis of many experimental post-dryout data, it is shown that the most probable flow regime near dryout or quench front is not annular flow but churn-turbulent flow when the mass flux is low. A correlation describing the initial droplet size just after the CHF position at low mass flux is suggested through regression analysis. In the post-dryout region at low pressure and low flow, it is found that the suggested one-dimensional mechanistic model is not applicable when the vapor superficial velocity is very low, i.e., when the flow is bubbly or slug flow regime. This is explained by the change of main entrainment mechanism with the change of flow regime. Therefore, the suggested correlation is valid only in the churn-turbulent flow regime ( $j_{g}$ $^{*}$=0.5~4.5).).

  • PDF

Si 입자를 함유한 반도체 세정폐수의 한외여과 특성 [II] -Polyolefin 관형막에 의한 투과분리- (Permeation Behavior of Semiconductor Rinsing Wastewater Containing Si Particles in Ultrafiltration System -II. Permeation Characteristics of Tubular Membrane)

  • 남석태;여호택;전재홍;이석기;최호상
    • 멤브레인
    • /
    • 제9권1호
    • /
    • pp.36-42
    • /
    • 1999
  • 본 연구에서는 Si 미립자를 함유한 반도체 세정폐수의 관형막을 이용한 한외여과특성을 검토하였다. 관형막의 시간변화에 따른 투과유속의 감소현상은 막표면에 형성된 케익층의 증가 및 기공막힘에 기인하며, cross flow는 케익여과에 의한 막오염 형태를 보였으나 dead-end flow는 기공막힘과 케익여과에 의한 혼합형태를 보였다. Cross Flow의 케익저항의 크기는 3.16$\times$$10^{12}$ ~4.34$\times$$10^{12}$ $m^{-1}$ 였고, dead-end flow 는 6.6 $\times$$10^{12}$ ~12.19$\times$$10^{12}$ $m^{-1}$였다. 운전초기의 흐름형태에 따른 투과유속은 cross flow 가 dead-end flow 의 약 7 배였다. Cross flow 투과유속은 약 42 $\ell$/$m^2$ hr, 용질배제율은 약 96 % 였으며, 분리막공정을 거친 투과수 중의 Si 입자의 평균크기는 20nm였다.

  • PDF

Critical Heat Flux in Uniformly Heated Vertical Annulus Under a Wide Range of Pressures 0.57 to 15.0 MPa

  • Chun, Se-Young;Chung, Heung-June;Hong, Sung-Deok;Yang, Sun-Kyu;Chung, Moon-Ki
    • Nuclear Engineering and Technology
    • /
    • 제32권2호
    • /
    • pp.128-141
    • /
    • 2000
  • The critical heat flux (CHF)experiments have been carried out in a wide range of pressures for an internally heated vertical annulus. The experimental conditions covered ranges of pressures from 0.57 to 15.01 MPa, mass fluxes of 0 kg/$m^2$s and from 200 to 650 kg/$m^2$s, and inlet subcoolings from 85 to 413 kJ/kg. The characteristics of the present data and the effect of pressure on CHF are discussed. Most of the CHFs were identified to dryout of the liquid film in the annular or annular-mist flow. For the mass flux of 200 kg/$m^2$s, there were the indications that the CHF occurred at the transition from annular to annular-mist How in the pressure range of 3~10 MPa. For the mass fluxes of 550 and 650 kg/$m^2$s, the CHFs had a maximum value at a pressure of 2~3 MPa, and the pressure at the maximum CHF values had a trend moving toward the pressure at the peak value of pool boiling CHF as the mass flux decreased. The CHF data under a zero mass flux condition indicate that both the effects of pressure and inlet subcooling on the CHF were smaller, compared with those on the CHF with net water upward flow.

  • PDF

Hyperbolicity Breaking Model and Drift-Flux Model for the Prediction of Flow Regime Transition after Inverted Annular Flow

  • Jeong, Hae-Yong;No, Hee-Cheon
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1995년도 추계학술발표회논문집(1)
    • /
    • pp.456-461
    • /
    • 1995
  • The concept of hyperbolicity breaking is applied to predict the flow regime transition from inverted annular flow (IAF) to agitated inverted annular flow (AIAF). The resultant correlation has the similar form to Takenaka's empirical one. To validate the proposed model, it is applied to predict Takenaka's experimental results using R-113 refrigerant with four different tube diameters of 3, 5, 7 and 10 mm. The proposed model gives accurate predictions for the tube diameters of 7 and 10 min. As the tube diameter decreases, the differences between the predictions and the experimental results increase slightly. The flow regime transition from AIAF to dispersed flow (DF) is described by the drift flux model.

  • PDF

Development of Critical Heat Flux Correction Factor for Water under Flow Oscillation Conditions

  • Kim, Yun-Il;Baek, Won-Pil;Chang, Soon-Heung
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 추계학술발표회논문집(1)
    • /
    • pp.242-247
    • /
    • 1996
  • Flow oscillations in boiling channels induces a drastic reduction of the (critical heat flux) CHF or premature burnout. However, most of CHF works and correlations have been focused on stable flow conditions without considering flow oscillation. Therefore to improve the understanding on flow oscillation CHF, in this paper a new CHF correction factor to predict the CHF values under flow oscillation conditions has been developed from 126 experimental data. Also to investigate the dominant factor on flow oscillation CHF parametric trends are analyzed by using the developed correction factor. The overall mean accuracy ratio of the developed correction factor is 1.033 with a standard deviation of 0.195. The RMS errors 0.198. Its assessment shows that the predictions agree well with the experimental data within 25% error bounds.

  • PDF

An Improved Mechanistic Critical Heat Flux Model for Subcooled Flow Boiling

  • Young Min Kwon;Soon Heung Chang
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1997년도 추계학술발표회논문집(1)
    • /
    • pp.552-557
    • /
    • 1997
  • Based on the bubble coalescence adjacent to the heated wall as a flow structure for CHF condition, Chang and Lee developed a mechanistic critical heat flux (CHF) model for subcooled flow boiling. In this paper, improvements of Chang-Lee model are implemented with more solid theoretical bases for subcooled and low-quality flow boiling in tubes. Nedderman-Shearer's equations for the skin friction factor and universal velocity profile models are employed. Slip effect of movable bubbly layer is implemented to improve the predictability of low mass flow. Also, mechanistic subcooled flow boiling model is used to predict the flow quality and void fraction. The performance of the present model is verified using the KAIST CHF database of water in uniformly heated tubes. It is found that the present model can give a satisfactory agreement with experimental data within less than 9% RMS error.

  • PDF

풍상차분법을 이용한 압축기 익렬유동 해석 (Compressor Cascade Flow Analysis by Using Upwind Flux Difference Splitting Method)

  • 권창오;송동주;강신형
    • 대한기계학회논문집
    • /
    • 제18권3호
    • /
    • pp.653-661
    • /
    • 1994
  • In this paper the CSCM type upwind flux difference splitting Navier-Stokes method has been applied to study the ARL-SL19 supersonic/transonic compressor cascade flow. H-type grid was chosen for its simplicity in applying cyclic tridiagonal matrix algorithm along with conventional slip/no-slip boundary conditions. The thin-layer algebraic model of Baldwin-Lomax was employed for the calculation of turbulent flows. The test case inlet Mach No. was 1.612 and inlet/exit pressure ratio($P_2/P_1$) was 2.15. The results were compared with experimental results from current method were compared well in suction surface with the experiments and other computational results; however, not well in pressure surface. It might be due to the complex flowfields such as shock/boundary layer interaction, turbulence, and flow separation, etc. In the future, a proper turbulence modelling and adaptive grid system will be studied to improve the solution quality.

뭉뚝물체 주변에 형성된 극초음속유동에 대한 Navier-Stokes 계산 (Navier-Stokes Computations for Hypersonic flow on Blunt Bodies)

  • 백두성;김득상
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2001년도 추계 학술대회논문집
    • /
    • pp.91-97
    • /
    • 2001
  • The thin-layer Navier-Stokes equations are solved for the hypersonic flow over blunt cone configurations with applications to laminar as well as turbulent flows. The equations are expressed in the forms of flux-vector splitting and explicit algorithm. The upwind schemes of Steger-Warming and van Leer are investigated in their ability to accurately predict the heating loads along the surface of the body. A comparison with the second order extensions of these schemes is made and a hybrid scheme incorporating a combination of central differencing and flux-vector-splitting is presented. This scheme is also investigated in its ability to accurately predict heat transfer distributions.

  • PDF

Flow-3D를 활용한 수질정화체가 설치된 농업용 배수로의 안정성 조사 (Investigation of the Hydraulic Stability of Agricultural Drainage Channels Installed Water Purification Materials by using Flow-3D)

  • 김선주;박기춘
    • 한국농공학회논문집
    • /
    • 제49권5호
    • /
    • pp.3-9
    • /
    • 2007
  • In this study, the effect of the purification materials is analyzed and tested by Flow 3D and Hydraulic model test. Three dimension numerical analysis led from the research that sees abnormal form and the size back of the water purification material conferred the flowing water conduct inside the test channel against the test condition. Comparison it analyzed the flux distribution, a water depth of the channel which establishes the water purification materials the cross section, an interval of the water purification material, a conference with general channel, it change executed. As a result, the cross section ratio of the purification materials against and a flux change from the test which it sees. The interval of the purification materials in order to prevent three dimension that follows in decrease of increase and flux must decide an interval.

77K에서 트랜지스터 특성을 나타내는 링크의 제작 (Fabrication of the weak link with the the Transistor Characteristics in 77 K)

  • 강형곤;임성훈;고석철;주철원;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.921-926
    • /
    • 2001
  • The link for the Superconducting Flux Flow Transistor (SFFT) which is based on the flux flow has been fabricated by the ICP etching methods. The channel width and the thickness of the SFFT were a 3 ${\mu}$m and about 300 nm, respectively. The superconducting characteristic of the link was measured by the x-ray diffraction and the E.D.S.. The SFFT etched by ICP showed an I-V characteristic like the three terminal transistor.

  • PDF