• 제목/요약/키워드: Flow Field analysis

검색결과 2,181건 처리시간 0.034초

사각덕트 내 이단 오리피스를 지나는 유동의 압력강하에 대한 수치해석 (A Numerical analysis on the pressure drop of the flow field past a two-staged orifice in a rectangular duct)

  • 송우열;김유곤
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2747-2752
    • /
    • 2007
  • A numerical study has been performed on the flow past a two-staged orifice in a rectangular duct. The flow field including the recirculation region behind the orifice was investigated and the pressure drop was calculated. Water was used as a working fluid and the flow was treated as the turbulent flow, of which the Raynolds number was 6000. The main parameters for the pressure drop and the recirculation region were the orifice's inclined angle against the duct, the interval between two orifices, the shape of the orifice's hole having the same area, and the change of the hole position at the same interval. The variation of the flow field was investigated with each parameter. Consequently, it was found that the most dominant parameter influencing the drop of the pressure was the change of the hole position at the same interval between orifices. Especially when the interval between orifices was narrow and the relative position the holes was changed, its effect to the flow field was shown most drastically as a result of this study. The SIMPLER algorithm with FLUENT code was employed to analyze the flow field.

  • PDF

PIV 계측에 의한 고주파수 초음파 유동장 해석에 관한 연구 (A Study on the Flow Field Analysis with a High-frequency Ultrasonic by PIV Measurement)

  • 이상범;송민근;손승우;정광수;주은선
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.727-732
    • /
    • 2001
  • The purpose of this study is to compare the time mean velocity distribution, the time mean kinetic energy, and the time mean turbulence intensity between vertical and horizontal flow fields in a coaxial circular pipe by PIV measurement. Experiments are performed at a Reynolds number 2,000, measuring regions divided as the section regions A, B, C, D in flow fields. The angle of the high-frequency ultrasonic is selected in the direction of $45^{\circ}$ to the flow axes and it is reflected several times. In results, it is clarified that the effect of gravity is given in the vertical flow field compared with the horizontal flow field and the ultrasonic affects the turbulence enhancement. And kinetic energy and turbulence intensity with ultrasonic are shown slightly bigger than those in flow field without it.

  • PDF

중성자 래디오그래피를 이용한 액체금속 유동장 측정 (Measurement of Liquid-Metal Flow with a Dynamic Neutron Radiography)

  • 차재은;사이토
    • 한국가시화정보학회지
    • /
    • 제9권4호
    • /
    • pp.63-68
    • /
    • 2011
  • The flow-field of a liquid-metal system is very important for the safety analysis and the design of the steam generator of liquid-metal fast breeder reactor. Dynamic neutron radiography (DNR) is suitable for a visualization and measurement of a liquid metal flow and a two-phase flow in a metallic duct. However, the three dimensional DNR techniques is not enough to obtain the velocity information in the wide channel up to now. In this research, a high speed DNR technique was applied to visualize the heavy liquid-metal flow field in the narrow channel with the HANARO-beam facility. The images were taken with a high frame-rate neutron radiography at 250 fps and analyzed with a Particle Image Velocimetry(PIV) method. The images were compared with the results of the commercial CFX code to study the feasibility of DNR technique for the measuring the heavy liquid-metal flow field. The PIV images could discern the turbulent vortex flow in the two-dimensional narrow channel.

Flow Field Change before Onset of Flow Separation

  • Hasegawa, Hiroaki;Sugawara, Takeru
    • International Journal of Fluid Machinery and Systems
    • /
    • 제2권3호
    • /
    • pp.215-222
    • /
    • 2009
  • Jets issuing through small holes in a wall into a freestream has proven effective in the control of flow separation. This technique is known as the vortex generator jet (VGJs) method. If a precursor signal of separation is found, the separation control system using VGJs can be operated just before the onset of separation and the flow field with no separation is always attained. In this study, we measured the flow field and the wall static pressure in a two-dimensional diffuser to find a precursor signal of flow separation. The streamwise velocity measurements were carried out in the separated shear layer and spectral analysis was applied to the velocity fluctuations at some angles with respect to the diffuser. The pattern of peaks in the spectral analysis changes as the divergence angle increases over the angle of which the whole separation occurs. This change in the spectral pattern is related to the enhancement of the growth of shear layer vortices and appears just before the onset of separation. Therefore, the growth of shear layer vortices can be regarded as a precursor signal to flow separation.

Design and analysis of RIF scheme to improve the CFD efficiency of rod-type PWR core

  • Chen, Guangliang;Qian, Hao;Li, Lei;Yu, Yang;Zhang, Zhijian;Tian, Zhaofei;Li, Xiaochang
    • Nuclear Engineering and Technology
    • /
    • 제53권10호
    • /
    • pp.3171-3181
    • /
    • 2021
  • This research serves to advance the development of engineering computational fluid dynamics (CFD) computing efficiency for the analysis of pressurized water reactor (PWR) core using rod-type fuel assemblies with mixing vanes (one kind of typical PWR core). In this research, a CFD scheme based on the reconstruction of the initial fine flow field (RIF CFD scheme) is proposed and analyzed. The RIF scheme is based on the quantitative regulation of flow velocities in the rod-type PWR core and the principle that the CFD computing efficiency can be improved greatly by a perfect initialization. In this paper, it is discovered that the RIF scheme can significantly improve the computing efficiency of the CFD computation for the rod-type PWR core. Furthermore, the RIF scheme also can reduce the computing resources needed for effective data storage of the large fluid domain in a rod-type PWR core. Moreover, a flow-ranking RIF CFD scheme is also designed based on the ranking of the flow rate, which enhances the utilization of the flow field with a closed flow rate to reconstruct the fine flow field. The flow-ranking RIF CFD scheme also proved to be very effective in improving the CFD efficiency for the rod-type PWR core.

Effect of the curved vane on the hydraulic response of the bridge pier

  • Qasim, Rafi M.;Jabbar, Tahseen A.;Faisa, Safaa H.
    • Ocean Systems Engineering
    • /
    • 제12권3호
    • /
    • pp.335-358
    • /
    • 2022
  • Hydrodynamic field alteration around a cylindrical pier using a curved vane is numerically investigated. The curved vane with various angles ranged from 10 to 220 degree is placed at the upstream of the cylindrical pier. Laminar flow is adopted in order to perform the steady-state analysis. It is found that the flow separation leads to the formation of four bubbles depending on the value of the curved vane angle. Two bubbles are located in the region between the rear of the curved vane and the leading surface of the cylindrical pier, while the remaining two bubbles are located at the wake zone behind the cylindrical pier. Numerical analysis is performed to reveal the hydrodynamic field and influence of curved vane on the formation and evolution of the bubbles. It is found that the center and size of the bubble depend mainly on the value of the curved vane angle. It is observed that the flow velocity vector shows clearly the alteration in the flow velocity direction especially at the leading surface and rear surface of the curved vane owing to the occurrence of flow separation and flow dissipation along the circumference of the vane.

아크플라즈마와 유동간의 상호작용을 고려한 열가스 유동 해석 (Analysis of Hot Gas Flew Considering Arc-Flow Interaction)

  • 김홍규;박경엽;배채윤;조경연;정현교
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제51권3호
    • /
    • pp.107-115
    • /
    • 2002
  • This parer presents the analysis of hot gas flow in puffer-type circuit breakers using FVFLIC method. For the analysis of arc-flow interaction, the flow field is analyzed from the equations of conservation for mass, momentum and energy with the assumption of local thermodynamic equilibrium state. The arc is represented as the energy source term composed of ohmic heating and radiation term in the energy conservation equation. Ohmic heating is computed by the electric field analysis only within the conducting plasma region. An approximate radiation transport model is employed for the evaluation of emission and absorption of the radiation. The analysis method was applied to the real circuit breaker model and simulation results such as pressure rise and arc voltage were compared with the experimental ones.

Flow Field Analysis for Ultrasonic Flow Meter

  • OSHIMA Yuko;TAKAMIYA Toshiyuki;ITO Shigeyuki
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2003년도 The Fifth Asian Computational Fluid Dynamics Conference
    • /
    • pp.209-209
    • /
    • 2003
  • PDF

원심압축기 회전차 내부의 3차원 유동해석 (Calculation of 3-Dimensional Flow Through an Impeller of Centrifugal Compressor)

  • 강신형;최영석
    • 대한기계학회논문집
    • /
    • 제19권10호
    • /
    • pp.2617-2629
    • /
    • 1995
  • The flow through a centrifugal compressor rotor was calculated using the quasi-3-dimensional and fully 3-dimensional Navier-Stokes solution methods. The calculated results, obtained during the development of the computer codes for both methods are discussed. In the inviscid quasi 3-dimensional analysis, stream function formulation was used for the blade to blade (B-B) plane calculations, and the streamline curvature method was used for the meridional (H-S) plane calculations. In the viscous 3-dimensional flow analysis, a control volume method based on a general rotating curvilinear coordinate system was used to solve the time-averaged Navier-Stokes equations, and a standard k-.epsilon. model was used to obtain eddy viscosity. The quasi-3-dimensional analysis reasonably predicts the pressure distributions and requires much less computation time in the region where viscous effects are not strong; however, it fails to predict velocity field and loss mechanism through the impeller passage. The viscous 3-dimensional flow analysis shows reasonable pressure distributions and typical jet-wake flow field through the impeller passage. Secondary flow and total pressure distributions on cross-sectional planes explain the loss mechanisms through the impeller.

Nonlinear finite element analysis of reinforced concrete structures subjected to transient thermal loads

  • Zhou, C.E.;Vecchio, F.J.
    • Computers and Concrete
    • /
    • 제2권6호
    • /
    • pp.455-479
    • /
    • 2005
  • This paper describes a 2D nonlinear finite element analysis (NLFEA) platform that combines heat flow analysis with realistic analysis of cracked reinforced concrete structures. The behavior models included in the structural analysis are mainly based on the Modified Compression Field Theory and the Distributed Stress Field Model. The heat flow analysis takes into account time-varying thermal loads and temperature-dependent material properties. The capability of 2D nonlinear transient thermal analysis is then implemented into a nonlinear finite element analysis program VecTor2(C) for 2D reinforced concrete membranes. Analyses of four numerical examples are performed using VecTor2, and results obtained indicate that the suggested nonlinear finite element analysis procedure is capable of modeling the complete response of a concrete structure to thermal and mechanical loads.