• Title/Summary/Keyword: Flow Field Plate

Search Result 270, Processing Time 0.022 seconds

Control of flow-induced noise from a circular cylinder using a splitter plate (분할판을 이용한 원형실린더 유동소음의 제어)

  • 유동현;최해천;최명렬;강신형
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.636-642
    • /
    • 1997
  • Laminar vortex shedding behind a circular cylinder with and without splitter plates attached to the circular cylinder at low Reynolds numbers are simulated by solving the unsteady incompressible Navier-Strokes equations. The Strouhal number, lift and drag rapidly change with the splitter plate. Far-field noise from the vortex shedding behind the cylinder is computed using the Lighthill acoustic analogy and the Curle's solution for the Lighthill equation. The acoustic source functions are obtained from the computed near-field velocity and pressure. Numerical results show that the volume quadrupole noise is small at low Mach numbers, compared with the surface dipole noise. Also the amplitude and frequency of the acoustic density fluctuations are varied with the length of splitter plates. The scattering effects at the edge of a splitter plate are considered by using the half-plane Green's function.

  • PDF

The Study of Heat Transfer on a Isothermal Circular Surface by an Impinging, Circular Water Jets with the Low Velocity Against the Direction of Gravity (중력방향과 대향류인 저속 원형노즐제트 충돌에 의한 일정 두께 하향 등온원형평판에서의 열전달 현상)

  • Eom, Yongkyoon
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.25 no.4
    • /
    • pp.449-458
    • /
    • 2014
  • The heat transfer phenomenon was investigated in this study when a single round water jet with the low velocity and against the direction of gravity flows to the downward facing Isothermal of definite thickness circular plate. Experimental investigation is performed for a single round jet diameter 4mm, 6mm, and 8mm with the jet velocity 2.4m/s and jet fluid temperature of $24^{\circ}C$, varied the ratio of nozzle clearance/nozzle diameter (H/D)1, 2, 3, 6, and 8, on circular plate isothermal condition with $85^{\circ}C$. The local convection heat transfer coefficient distributions are analyzed based on the visualization of jet flow field. The effects of the diameter of Nozzle, the ratio of H/D and the ratio of nozzle diameter/circular plate diameter on heat transfer phenomenon are investigated. As a results of experiment is obtained correlation equation, $Nu_r=3.18Re_r^{0.55}Pr_r^{0.4}$.

A study on the early stage of a transitional boundary layer and far field noise using a large eddy simulation technique (큰 에디 모사 기법을 이용한 초기 천이 경계층 유동 및 방사 소음 해석)

  • Choe, Myeong-Ryeol;Choe, Hae-Cheon;Gang, Sin-Hyeong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.6
    • /
    • pp.779-792
    • /
    • 1997
  • Flow characteristics are numerically investigated when a packet of waves consisting of a Tollmien-Schlichting wave and a pair of Squire waves evolves in a flat-plate laminar boundary layer using a large eddy simulation with a dynamic subgrid-scale model. Characteristics of early stage transitional boundary layer flow such as the .LAMBDA. vortex, variation of the skin friction and backscatter are predicted. Smagorinsky constants and the eddy viscosity obtained from the dynamic subgrid-scale model significantly change as the flow evolves. Far Field noise radiated from the transitional boundary layer shows the dipole and quadrupole characteristics owing to the wall shear stress and the Reynolds stresses, respectively.

Optimization of Cathode Flow Field Design for a PEMFC with Six Sigma Technique (Six sigma 기법을 이용한 PEMFC Cathode 유로설계 최적화)

  • Kim, Sun-Hoe
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.20 no.6
    • /
    • pp.492-498
    • /
    • 2009
  • Six sigma methode was applied for optimization of flow field design of a proton exchange membrane fuel cell (PEMFC). The optimization between number of channel and channel/rib width was suggested in this paper with six sigma method. With the help of six sigma design of experiment (DOE) the number of experiments may be reduced dramatically. The fuel cell channel design optimization with results of these experiments with a 100 $cm^2$ serpentine flow field indicates a optimization data for a given constant operating conditions.

Thrust Caused by Oscillating Two-Dimensional Hydrofoil Moving in Propagating Unsteady Flow Field (전파하는 변동유장 중 전진하며 동요하는 2차원 수중 날개에 의한 추력)

  • Choi, Yoon-Rak
    • Journal of Ocean Engineering and Technology
    • /
    • v.26 no.5
    • /
    • pp.40-46
    • /
    • 2012
  • This paper considers a two-dimensional hydrofoil that is fully submerged and oscillating with forward speed. The flow field is assumed to be a propagating vertical velocity field. Using the perturbation theory, the problem is linearized, and the leading-order lift force is surveyed. The thrust force is analytically derived as the second-order horizontal force. As an example, the lift and thrust for a flapping flat plate in heaving and pitching modes are analyzed. The parameters affecting the thrust are listed. The thrust is expressed in terms of the quadratic transfer functions in relation to the disturbances. The quadratic transfer functions are studied parametrically to assess the most favorable thrust.

Wave Diffractions by Submerged Flat Plate in oblique Waves (경사파중 수중평판에 의한 파랑변형)

  • Cho, I.H.;Kim, H.J.
    • Journal of Korean Port Research
    • /
    • v.10 no.1
    • /
    • pp.53-61
    • /
    • 1996
  • This paper describes the effect of wave control using submerged flat plate by the numerical calculation and the hydraulic model test. The boundary element method is used to develop a numerical solution for the flow field caused by monochromatic oblique waves incident upon an infinitely long, sumerged flat plate situated in arbitrary water depth. The effect of wave blocking is examined according to the change of length, submerged depth of flat plate and incident angles. Numerical results show that longer length, shallower submergence of flat plate and larger incident angles enhance the effect of wave blocking. To validate numerical analysis method, hydraulic model test was conducted in 2-D wave flume with 60 cm metal sheet. Reflected waves are extracted from water surface elevation in front of the location of a submerged plate by least square method with 3 wave gages. From comparing experimental results with numerical results, efficiency of numerical analysis method by this study could be confirmed well within wide ranges of wave frequencies.

  • PDF

Visualization of Vortex Flow around Coolant Outlets Using PIV and LDV (PIV와 LDV를 이용한 냉각수 토출구 주위의 와류 가시화 연구)

  • Hong, Ji-Woo;Shin, Su-Yong;Ahn, Byoung-Kwon
    • Journal of the Korean Society of Visualization
    • /
    • v.19 no.3
    • /
    • pp.136-142
    • /
    • 2021
  • Submerged and semi-submerged vehicles expel cooling water through an outlet. In this process, induced noise and vibration by the flow around the outlet have been reported, and it may cause problems directly related to survivability of the navy vessels. The coolant outlet has a net-type structure and circular columns are mostly used. In this study, flow measurements using PIV and LDV were performed for different type outlets; conventional (flat plate with round bar) and improved (flat and flat plate) configurations. Experiments were conducted at a cavitation tunnel where pressure and steady flow rate conditions are ensured for sufficient time to measure the flow. The average velocity field of the outlets were measured and compared through LDV measurements, and instantaneous vorticities were evaluated through PIV measurements. The results show that the improved type of the outlet is advantageous in terms of flow stability compared to the conventional type of the outlet.

Inverse Problem of Determining Unknown Inlet Temperature Profile in Two Phase Laminar Flow in a Parallel Plate Duct by Using Regularization Method (조정법을 이용한 덕트 내의 이상 층류 유동에 대한 입구 온도분포 역해석)

  • Hong, Yun-Ky;Baek, Seung-Wook
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.9
    • /
    • pp.1124-1132
    • /
    • 2004
  • The inverse problem of determining unknown inlet temperature in thermally developing, hydrodynamically developed two phase laminar flow in a parallel plate duct is considered. The inlet temperature profile is determined by measuring temperature in the flow field. No prior information is needed for the functional form of the inlet temperature profile. The inverse convection problem is solved by minimizing the objective function with regularization method. The conjugate gradient method as iterative method and the Tikhonov regularization method are employed. The effects of the functional form of inlet temperature, the number of measurement points and the measurement errors are investigated. The accuracy and efficiency of these two methods are compared and discussed.

Improvements of Inflow Controller Installed in Storm Overflow Diverging Tank for CSOs Control (우수토실에 설치된 월류수 제어를 위한 유입유량조절장치의 개선효과)

  • Lim, Bong-Su;Park, Youn-Hae;Kim, Tae-Eung
    • Journal of Korean Society on Water Environment
    • /
    • v.31 no.4
    • /
    • pp.428-435
    • /
    • 2015
  • This study was carried out to evaluate the performance of a inflow controller for the control of combined sewer overflows (CSOs). Because of the inflow controller could be adjusted manually by predicting the maximum amount of peak flow, the mechanical adjustment of this controller was higher than the existing fixed-type controller in field application. Standardizing the relationship between the flow and the clearance and angle of an inlet cover plate on the inflow conditions can selected to the optimum conditions for the on-site. It was concluded that BOD pollutant loading at the region in which inflow controller was installed had shown the removal efficiency rate of 42%.

Improvement of Separation of Polystyrene Particles with PAN Membranes in Hollow Fiber Flow Field-Flow Fractionation

  • Shin, Se-Jong;Chung, Hyun-Joo;Min, Byoung-Ryul;Park, Jin-Won;An, Ik-Sung;Lee, Kang-Taek
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.9
    • /
    • pp.1333-1338
    • /
    • 2003
  • Hollow Fiber flow field-flow fractionation (HF-FlFFF) has been tested in polyacrylonitrile (PAN) membrane channel in order to compare it with polysulfone (PSf) membrane channel. It has been experimentally shown that the separation time of 0.05-0.304 ${mu}m$ polystyrene latex (PSL) standards in PAN membrane channel is shorter than that in PSf channel by approximately 65%. The optimized separation condition in PAN membrane is ${\dot V}_{out}/{\dot V}_{rad}=1.4/0.12\;mL/min$, which is equal to the condition in PSf membrane channel. In addition both the resolution ($R_s$) and plate height (H) in PAN membrane channel are better than that in PSf membrane channel. The membrane radius was obtained by back calculation with retention time. It shows that the PSf membrane is expanded by swelling and pressure, but the PAN membrane doesn't expand by swelling and pressure.