• Title/Summary/Keyword: Flow Field 3D Measurement

Search Result 64, Processing Time 0.028 seconds

A Study on Developments of Three-dimensional Measurement System for Flow-Structure Interactions using Digital Image Processing (디지털 영상처리기술을 이용한 비접촉식 유체-구조 연동운동3차원 측정시스템 개발에 관한 연구)

  • DOH DEOG-HEE;SANG JI-WOONG;HWANG TAE-GYU;CHO YONG-BEOM;PYEON YONG-BEOM
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.274-278
    • /
    • 2004
  • A simultaneous measurement system that can analyze the flaw-structure interactions has been developed This system consists of four CCD cameras, two for capturing instantaneous flaw fields and two for tracking a solid body. The three-dimensional vector fields around a cylinder are measured while the motion of the cylinder forced by the flow field is measured simultaneously with the constructed system The cylinder is pended in the working fluid of a water channel and the surface of the working fluid is forced sinusoidal to make the cylinder bounced Reynolds number for the mean main stream is about l000. The interaction between the flaw fields and the cylinder motion is examined quantitatively.

  • PDF

An investigation of pressure oscillation in supersonic cavity flow (초음속 Cavity 내에서의 압력 진동 특성 연구)

  • Kim Hyungjun;Kim Sehoon;Kwon Sejin;Park Kunhong
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.743-746
    • /
    • 2002
  • Experimental investigation of the flow field of supersonic cavity is described. In this research, supersonic cavity is used in chemical laser system. For efficient laser, downstream flow after cavity need to be uniform and clear for pressure recovery system. In previous research, it's known that there's oscillation In cavity and is due to Mach number and L/D ratio. A strong recompression occurs at the after wall and the flow is visibly unsteady. Cavity flow in this research is of the open type, that is, length-to-depth ratio $L/D<10\;at\;M\;=\;3$. Experiment is done with pressure measurement by piezo-type sensor and visualization by Schlirern method. The time-dependent experimental result is compared with computation.

  • PDF

Prediction of Curvature Effects on the Electromagnetic Flowmeter Characteristics with Numerical Simulation (Laminar flow) (곡관의 곡률에 따른 전자기유량계 설치효과의 수치모사에 의한 특성 예측(충류))

  • Lim, Ki Won;Choi, Sang Kyu;Chung, Myung Kyoon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.11
    • /
    • pp.1453-1463
    • /
    • 1999
  • An electromagnetic flowmeter, based on a magnetic induction principle; provides an obstructionless flowmeter that essentially averages the velocity distribution over the pipe cross-sectional area. To predict the installation effects, the flowmeter installed near $90^{\circ}$ elbow is simulated by using a commercial code FLUENT(ver. 4.48) for the laminar flow field and a code developed through this study for magnetic field. The installation effects of the flowmeter are estimated by varying a number of the dependent parameters such as the radius of the elbow(Rc=1D, 1.5D, 2D, 3D), the location, Reynolds number and the direction of electrodes plane(${\varphi}$). It was found that all these factors affect the performance of the electromagnetic flowmeter significantly. The longer installation distance from the elbow is not always optimal to minimize the error, and also there exists an optimal location to install the EMF for a minimum error. Especially the flow signal with the electrodes plane direction of ${\varphi}=45^{\circ}$ is shown to yield smallest measurement error regardless of the Reynolds number and the curvature of elbow.

Advanced Flow Visualization Techniques for Diagnosing Microscale Biofluid Flows (미세 생체유동 해석을 위한 첨단 유동가시화기법)

  • Lee, Sang-Joon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.1
    • /
    • pp.1-8
    • /
    • 2009
  • Recently microscale biofluid flows have been receiving large attention in various research areas. However, most conventional imaging techniques are unsatisfactory due to difficulties encountered in the visualization of microscale biological flows. Recent advances in optics and digital image processing techniques have made it possible to develop several advanced micro-PIV/PTV techniques. They can be used to get quantitative velocity field information of various biofluid flows from visualized images of tracer particles. In this paper, as new advanced micro-PIV techniques suitable for biofluid flow analysis, the basic principle and typical applications of the time-resolved micro-PIV and X-ray micro-PIV methods are explained. As a 3D velocity field measurement technique for measuring microscale flows, holographic micro-PTV method is introduced. These advanced PIV/PTV techniques can be used to reveal the basic physics of various microscale biological flows and will play an important role in visualizing veiled biofluid flow phenomena, for which conventional methods have many difficulties to analyze.

PIV measurement of step cavity with driven flow (구동류를 갖는 계단 캐비티의 PIV계측)

  • 조대환;김진구;이영호
    • Journal of Ocean Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.113-119
    • /
    • 1998
  • An experimental study was carried out in a three-dimensional cubic cavity driven by 2-dimensional plane Poiseuille flow for three kinds of Reynolds number, $10^4$, 3 $\times$ $10^4$ and 5 $\times$ $10^4$ based on the cavity width and cavity inlet mean flow velcoity. Instant simultaneous velocity vectors at whole field were measured by 2-D PIV system. Laser based illumination and two-frame grey-level cross correlation algorithm are adopted. Severe unsteady flow fluctuation within the cavity are remarkable at above Re = 3 $\times$ $10^4$ Reynolds numbers and sheared mixing layer phenomena are also found at the region where inlet driving Poiseuille flow is collided with the clock-wise rotating main primary vortex at upper center area. Instant velocity profiles reveal that deformed forced vortex formation is observed throughout the separate two areas.

  • PDF

Development of Digital Holographic PIV Technique and Its Application (Digital Holographic PIV 기법의 개발과 제트유동에의 응용)

  • Kim, Seok;Lee, Sang-Joon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.1 s.232
    • /
    • pp.123-130
    • /
    • 2005
  • A digital in-line holographic particle image velocimetry (HPIV) which can be applied to measure three-dimensional velocity fields of turbulent flows was developed. There are three different implementation methods of HPIV: traditional film-based HPIV, intermediate HPIV and digital HPIV. The traditional film-based HPIV and intermediate HPIV method is rather troublesome to do experiments and takes long calculation time, compared with the digital HPIV, Configuration of the digital in-line HPIV is simple and the data processing routine is similar to conventional 2D PIV methods. The digital HPIV velocity field measurement consists of four steps: recording, numerical reconstruction, particle extraction and velocity extraction. In the velocity extraction process, we improved PTV algorithm to extract the displacement of particle each placed in 3D space. The developed digital in-line HPIV system was applied to a vertical jet flow. The 3D velocity vectors measured by the digital HPIV method in the near field are in a good agreement with 2D PIV results.

A Study on Flow Induced Vibration of Cantilever Plate with Angle of Attack (받음각을 갖는 평판보의 유동 여기진동에 관한 연구)

  • 이기백;손창민;김봉환
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.6
    • /
    • pp.1919-1932
    • /
    • 1991
  • Experimental studies are conducted to investigate the Flow-Induced Vibration mechanism for cantilever plate model with the angle of attack (.alpha.=10.deg., 20.deg., 30.deg.). Research is divided into two parts. First, the flow fields around two dimensional flat plate model are investigated using LDV system. Second, the vortex shedding frequency and response spectra of cantilever plate are obtained experimentally using gap sensor and hot wire anemometer. Finite element method program was used in order to predict the flow field and pressure field around thin flat plate. And some predicted results were compared with the experimental data. The aspect ration of test model is d/t=25 (d; width, t; thickness). From the measurement of the flow field it was found that in the case of small inclined (.alpha.=10.deg., 20.deg.) relatively, the separated boundary layer at sharp leading edge developed smoothly downstream. With increasing the angle of attack of the plate, stagnation region was appeared on the back side of the plate and separated boundary layer was extended downstream. These trends are a good agreement with the computational results. It was found by analysis of response spectra of cantilever plate that the influences of vortex shedding frequency were important at the large of attack (.alpha.=30.deg.), and two peak values appear in entire test model at 24Hz, 150Hz.

Pressure-Rise Measurement and Analysis of Low Current Interruption Capability of a 72.5kV 20kA Gas Circuit Breaker for Electrical Railway System (72.5kV 20kA 전철용 가스차단기의 압력상승 측정 및 소전류 차단성능해석)

  • Song, K.D.;Park, K.Y.;Chong, J.K.;Oh, Y.H.;Min, K.S.;Park, Ki-Y.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07a
    • /
    • pp.164-166
    • /
    • 1998
  • This paper presents the results of the measured pressure-rise and the analyzed results of the cold gas flow-field in a 72.5kV 20kA gas circuit breaker for the electrical railway system. The analysis of cold gas flow field and the calculation of electric field strength have been performed in 3 types of interrupters and the low current interruption capability has been estimated for each of the gas circuit breaker considering the opening speed, the nozzle shape and the stroke length.

  • PDF

3D Particle Image Detection by Using Color Encoded Illumination System

  • Kawahashi M.;Hirahara H.
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2001.12a
    • /
    • pp.100-107
    • /
    • 2001
  • A simple new technique of particle depth position measurement, which can be applied for three-dimensional velocity measurement of fluid flows, is proposed. Two color illumination system that intensity is encoded as a function of z-coordinate is introduced. A calibration procedure is described and a profile of small sphere is detected by using the present method as preliminary test. Then, this method is applied to three-dimensional velocity field measurement of simple flow fields seeded with tracer particles. The motion of the particles is recorded by color 3CCD camera. The particle position in the image plane is read directly from the recorded image and the depth of each particle is measured by calculation of the intensity ratio of encoded two color illumination. Therefore three-dimensional velocity components are reconstructed. Although the result includes to some extent error, the feasibility of the present technique for three-dimensional velocity measurement was confirmed.

  • PDF

Modelling of Fault Deformation Induced by Fluid Injection using Hydro-Mechanical Coupled 3D Particle Flow Code: DECOVALEX-2019 Task B (수리역학적연계 3차원 입자유동코드를 사용한 유체주입에 의한 단층변형 모델링: DECOVALEX-2019 Task B)

  • Yoon, Jeoung Seok;Zhou, Jian
    • Tunnel and Underground Space
    • /
    • v.30 no.4
    • /
    • pp.320-334
    • /
    • 2020
  • This study presents an application of hydro-mechanical coupled Particle Flow Code 3D (PFC3D) to simulation of fluid injection induced fault slip experiment conducted in Mont Terri Switzerland as a part of a task in an international research project DECOVALEX-2019. We also aimed as identifying the current limitations of the modelling method and issues for further development. A fluid flow algorithm was developed and implemented in a 3D pore-pipe network model in a 3D bonded particle assembly using PFC3D v5, and was applied to Mont Terri Step 2 minor fault activation experiment. The simulated results showed that the injected fluid migrates through the permeable fault zone and induces fault deformation, demonstrating a full hydro-mechanical coupled behavior. The simulated results were, however, partially matching with the field measurement. The simulated pressure build-up at the monitoring location showed linear and progressive increase, whereas the field measurement showed an abrupt increase associated with the fault slip We conclude that such difference between the modelling and the field test is due to the structure of the fault in the model which was represented as a combination of damage zone and core fractures. The modelled fault is likely larger in size than the real fault in Mont Terri site. Therefore, the modelled fault allows several path ways of fluid flow from the injection location to the pressure monitoring location, leading to smooth pressure build-up at the monitoring location while the injection pressure increases, and an early start of pressure decay even before the injection pressure reaches the maximum. We also conclude that the clay filling in the real fault could have acted as a fluid barrier which may have resulted in formation of fluid over-pressurization locally in the fault. Unlike the pressure result, the simulated fault deformations were matching with the field measurements. A better way of modelling a heterogeneous clay-filled fault structure with a narrow zone should be studied further to improve the applicability of the modelling method to fluid injection induced fault activation.