• Title/Summary/Keyword: Flow Detection

Search Result 1,241, Processing Time 0.025 seconds

A Robust Method for Automatic Segmentation and Recognition of Apoptosis Cell (Apoptosis 세포의 자동화된 분할 및 인식을 위한 강인한 방법)

  • Liu, Hai-Ling;Shin, Young-Suk
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.15 no.6
    • /
    • pp.464-468
    • /
    • 2009
  • In this paper we propose an image-based approach, which is different from the traditional flow cytometric method to detect shape of apoptosis cells. This method can overcome the defects of cytometry and give precise recognition of apoptosis cells. In this work K-means clustering was used to do the rough segmentation and an active contour model, called 'snake' was used to do the precise edge detection. And then some features were extracted including physical feature, shape descriptor and texture features of the apoptosis cells. Finally a Mahalanobis distance classifier classifies the segmentation images as apoptosis and non-apoptosis cell.

Study on the Diagnosis of Abnormal Prosthetic Valve

  • Lee, Hyuk-Soo
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.14 no.1
    • /
    • pp.1-5
    • /
    • 2013
  • The two major problems related to the blood flow in replaced prosthetic heart valve are thrombus formation and hemolysis. Reliability of prosthetic valve is very important because its failure means the death of patient. There are many factors affecting the valvular failures and their representatives are mechanical failure and thrombosis, so early noninvasive detection is essentially required. The purpose of this study is to detect the various thromboses formation by using acoustic signal acquisition and its spectral analysis on the frequency domain. We made the thrombosis models using Polydimethylsiloxane (PDMS) and they are thrombosis model on the disc, around the sewing ring and fibrous tissue growth across the orifice of valve. Using microphone and amplifier, we measured the acoustic signal from the prosthetic valve, which is attached to the pulsatile mock circulation system. A/D converter sampled the acoustic signal and the spectral analysis is the main algorithm for obtaining spectrum. Then the spectrum of normal and 5 different kinds of abnormal valve were obtained. Each spectrum waveform shows a primary and secondary peak. The secondary peak changes according to the thrombus model. To quantitatively distinguish the frequency peak of the normal valve from that of the thrombosed valves, analysis using a neural network was employed. Acoustic measurement has been used as a noninvasive diagnostic tool and is thought to be a good method for detecting possible mechanical failure or thrombus.

Inhibitory effect of Rhus verniciflua Stokes extract in MCF-7 human breast cancer cells (참옻 추출물의 MCF-7 인체 유방암 세포에서 증식 억제효과)

  • Kim, Min Sung;An, Won Gun;Lee, Jang Cheon
    • Herbal Formula Science
    • /
    • v.24 no.4
    • /
    • pp.283-288
    • /
    • 2016
  • Objectives : The purpose of this study was to investigate the anti-cancer effects of extract of Rhus verniciflua Stokes (RVS) in human breast cancer cell lines. Methods : In cultured human breast cancer MCF-7 cells, we investigated growth inhibitory effect of RVS. MCF-7 cells were cultured with various concentrations (0, 200, 300, and 400 ug/ml) of RVS at $37^{\circ}C$ for 24 h. We performed CCK-8 assay and flow cytometry for detection of Annexin V-PI staining. Results : As a result, RVS inhibits the cell growth and induction of apoptosis in dose dependent manner in MCF-7 breast cancer cells. Conclusion : RVS has anti-cancer activities and induced apoptosis in human breast cancer MCF-7 cells. Therefore we suggest that RVS can use as a novel class of anti-cancer drugs.

Method development and validation for dieckol in the standardization of phlorotannin preparations

  • Kim, Jiyoung;Um, Minyoung;Yang, Hyejin;Kim, Inho;Lee, Changho;Kim, Yuntai;Yoon, Minseok;Kim, Youngkyoung;Kim, Jimi;Cho, Suengmok
    • Fisheries and Aquatic Sciences
    • /
    • v.19 no.1
    • /
    • pp.3.1-3.6
    • /
    • 2016
  • Phlorotannins are reported to have diverse biological properties. However, no analytical methods for the standardization of phlorotannin preparations have been reported. Herein, we developed and validated an analytical method for the determination of dieckol in phlorotannin extracts (PRT) using high-performance liquid chromatography (HPLC). The optimum HPLC conditions consisted of a Supelco Discovery C18 column stationary phase, a mobile phase (A: 15 % HPLC grade methanol in deionized water, B: methanol), UV detection at 230 nm, and a flow rate of 0.7 mL/min. The optimized chromatographic conditions were validated and exhibited good specificity and linearity ($R^2$ > 0.9994-1.0000). The recoveries were in the range of 100.9-102.3 %. The method had good intermediate (%RSD 1.2) and intra-day (%RSD 0.4-1.7) assay precisions. This HPLC method had good accuracy and quality in the determination of dieckol in PRT.

Development of Continuous Monitoring System of Acidic Pollutants for The Studies of Their Diffusion in The Atmosphere (대기오염의 확산 연구를 위한 산성 오염물질의 연속 측정법의 개발)

  • Chung, Hyung-Keun;Dasgupta, Purnendu K.;Lee, Dai Woon
    • Analytical Science and Technology
    • /
    • v.5 no.3
    • /
    • pp.269-276
    • /
    • 1992
  • An ion-exchange/conductometric method is applied for the determination of total acidity in simulated atmospheric samples. Non-$H^+$ cations and strong acid anions are enriched by the preconcentrator columns in series and eluted through the corresponding parallel suppressor units. The conductivities from each channel correspond to the concentrations of the resulting ionized species in equivalents per unit volume. The difference is the measure of acidity due to strong acids. With 5-min sampling at a flow rate of 0.3 mL/min, the detection limits for ${NH_4}^+$ and ${SO_4}^{2-}$ are 0.3 and $0.1{\mu}equiv/L$, respectively. The acidity for samples composed of various ions can be determined without significant error, usually less than 5%. The proposed method discriminates against the artifact from the $CO_2$ dissolution. Principles of acidity measurements are also presented.

  • PDF

Development of an IV Infusion Rate Regulator Using Optical Drip Rate Meter (광센서 점적계를 이용한 정맥내 주입률 조절기의 개발)

  • Yang, Y.S.;Kim, H.C.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.127-128
    • /
    • 1998
  • It is necessary to maintain constant intravenous (IV) infusion rate. While infusion pump is able to control infusion rate with great accuracy, its rather large size and weight make it difficult for patients to move around. The most commonly used infusion device is gravity IV infusion set with its administration chamber being clamped according to the observed drip rate. In this case it may be easier and more accurate to maintain IV rate to given value if we automate the drip-counting process and tube-clamping work by electronic devices. We calculated volume infusion rate of specific fluid using optical drip rate meter which we had developed. To regulate fluid flow rate, we equipped the rate meter which we had developed with a miniaturized clamping apparatus using DC motor. Also, we Implemented drip detection and clamp control algorithm with PIC16C73 $\mu$-controller (Microchip). This system provides user interface through LCD display and key buttons.

  • PDF

What causes the Pulsus - Tardus and Parvus effect at the Arterial Post-stenosis region? (전기회로 모델을 이용한 동맥 협착 후부의 소지맥 현상 해석)

  • Kim, S.J.;Lee, D.H.;Kim, J.H.;Park, J.H.;Min, B.G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.471-474
    • /
    • 1997
  • Recently, many studies have shown clinically the detection of proximal arterial stenosis through evaluation of a Doppler waveform alternation, the so-called pulsus tardus and parvus, that often occurs distal to the stenosis. However the cause of the tardus-parvus phenomenon remains obscure. To analyze its cause, we modeled the blood-flow circuit as simple electrical circuit. This shows that pulsus tardus-parvus effect is caused as a result of high-frequency waveform component attenuation from low-pass filtering by capacitance(complience of the poststenotic vessel wall) and resistance(stenosis). As a result, the degree of pulsus tardus-parvus increased as the complience of the poststenotic segment of vessel increased, as well as increasing stenosis.

  • PDF

Antiproliferative Constituents from the Vinegar Treated Small Black Soybean (Glycine max Merr.)

  • Oh, Chan-Ho;Kim, Eun-Jeong;Lee, Kyu-Hee;Moon, Mi-Kyeong;Cho, Moon-Gu;Kim, Jong-Hwa;Oh, Suk-Heung;Lee, Tae-Kyoo;Shin, Tae-Yong;Kim, Dae-Keun
    • Natural Product Sciences
    • /
    • v.12 no.2
    • /
    • pp.109-112
    • /
    • 2006
  • The chloroform-soluble fraction of the vinegar treated small black soybean [Glycine max (Leguminosae)] showed antiproliferative activity against human myeloid leukemia HL-60 cells, in terms of inhibition of proliferation and induction of apoptosis. Bioassay-guided chromatography of the chloroform-soluble fraction resulted in the isolation of two isoflavonoid compounds, genistein and daidzein, as active principles. Genistein showed more potent antiproliferative effects against HL-60 cells. Treatment of HL-60 cells with genistein induced apoptosis in a dose dependent manner. Apoptosis was judged by the detection of DNA fragmentation by a flow cytometry and the degree of apoptosis was assayed by RT-PCR.

Quantitative HPLC Analysis and Extraction of 2,6-dimethoxy-1,4-benzoquinone from Ficus foveolata Stems

  • Meerungrueang, Wirod;Panichayupakaranant, Pharkphoom
    • Natural Product Sciences
    • /
    • v.21 no.3
    • /
    • pp.192-195
    • /
    • 2015
  • An antibacterial benzoquinone, 2,6-dimethoxy-1,4-benzoquinone, isolated from Ficus foveolata stems was used as a standard marker for establishment of quantitative HPLC analysis for the stem extracts of F. foveolata. The method utilized a TSK-gel ODS-80Ts column (5 μm, 4.6 × 250 mm) with the mixture of methanol and 5% acetic acid in water (24:76, v/v) as the mobile phase at a flow rate of 1 mL/min, and quantitative detection at 289 nm. The parameters i.e. linearity, intraday and interday precision, accuracy, specificity and sensitivity of the method were evaluated for method validation. The recoveries of the method were 99.5 - 103.6% and good linearity (R2 ≥ 0.9999) was obtained. A high degree of specificity, sensitivity as well as repeatability and reproducibility (RSD less than 2 and 5%, respectively) were also achieved. Chloroform was served as the most suitable solvent for extraction of 2,6-dimethoxy-1,4-benzoquinone. The optimised sample preparation and HPLC method can be practically used in the routine quality control process of F. foveolata stem extracts.

Quantitative Analysis of Twelve Marker Compounds in Palmijihwang-hwan using Ultra-Performance Liquid Chromatography Coupled with Electrospray Ionization Tandem Mass Spectrometry

  • Seo, Chang-Seob;Shin, Hyeun-Kyoo
    • Natural Product Sciences
    • /
    • v.20 no.3
    • /
    • pp.182-190
    • /
    • 2014
  • An ultra-performance liquid chromatography (UPLC) coupled with electrospray ionization (ESI) tandem mass spectrometry (MS) method was established for quantitative analysis of twelve components, allantoin (1), morroniside (2), 5-hydroxymethyl-2-furfural (5-HMF) (3), loganin (4), coumarin (5), cinnamic acid (6), mesaconitine (7), cinnamaldehyde (8), hypaconitine (9), aconitine (10), alisol B (11), and alisol B acetate (12) in a Palmijihwang-hwan decoction. The twelve constituents were separated on a UPLC BEH C18 column ($2.1{\times}100mm$, $1.7{\mu}m$) at a column temperature of $40^{\circ}C$ by gradient elution with 0.1% (v/v) formic acid in water and acetonitrile as the mobile phase. The flow rate was 0.3 mL/min and the injection volume was $2.0{\mu}L$. Calibration curves of all compounds were acquired with values of the correlation coefficient ${\geq}0.99$ within the test ranges. The limits of detection and quantification for all analytes were 0.01 - 4.53 ng/mL and 0.03 - 13.60 ng/mL, respectively. The concentrations of the compounds 1 - 9 and 12 were 72.83, 4389.00, 4859.00, 3155.17, 223.67, 33.50, 1.97, 518.00, 2.25, and $25.00{\mu}g/g$, respectively. However, compounds 10 and 11 were not detected.