• Title/Summary/Keyword: Flow Detection

Search Result 1,241, Processing Time 0.037 seconds

A Study on Detection of Overloaded Vehicles at Highway Toll Gates Using Detection of Height Changes in Vehicle Cargo Boxes (차량 적재함의 높이 변화 감지를 이용한 고속도로 톨게이트 과적차량 검출에 관한 연구)

  • Gwang Lee;Bong-Keun Kim
    • Journal of Practical Engineering Education
    • /
    • v.16 no.3_spc
    • /
    • pp.391-399
    • /
    • 2024
  • All highway toll gates in Korea use low-speed WIM(Weight-In-Motion) to block overloaded cargo vehicles from entering the main highway, but some cargo vehicle owners are illegally modifying vehicles to operate variable axles and evading crackdowns by manipulating the axles. In previous studies detect all tires of a running vehicle were detected to determine whether there is axle manipulation. However, because the vehicle entry area at the highway toll gate checkpoint is very narrow, there is a problem that it is realistically difficult to film all tires of the entering vehicle in one video frame. In this paper, we proposed a system that can determine whether the axle is being operated through changes in the height of the vehicle's cargo box rather than by detecting tires. To detect changes in the height of a cargo box, we propose a method to extract the representative line of the cargo box using Hough transform and then measure the change in height of the representative line to detect the change in height of the cargo box. In addition, we propose a method to detect changes in the vertical height of a cargo box by accumulating motion vectors of pixels within a certain area of the image using optical flow. And the two methods were compared and their advantages and disadvantages were analyzed and presented.

Pro-apoptotic Effects of Sanguisorbae Radix Ethanol-Extracts on Two Cholangiocarcinoma Cell Lines, SNU-1079 and SNU-1196 (담관암세포주에서 지유(地楡) 에탄올 추출물의 항암 효과)

  • Park, Jin-Kyu;Kim, Young-Chul
    • The Journal of Internal Korean Medicine
    • /
    • v.33 no.4
    • /
    • pp.465-475
    • /
    • 2012
  • Objectives : This study was performed to investigate the antineoplastic effect of ethanol extracts from Sanguisorbae Radix on cholangiocarcinoma cells that was established from biliary tract cancer tissue. Materials and Methods : Two cholangiocarcinoma cell lines, SNU-1079 and SNU-1196, were studied. The mRNA expression of Caspase 3, 8, 9, Bcl-2, Bax, P53, and P21 was examined by RT-PCR. Cell viability was determined by MTT assay. The cell cycle was analyzed by flow cytometry and apoptosis by cell death detection ELISA kit. Results : Proliferation of SNU-1079 and SNU-1196 was inhibited by Sanguisorbae Radix treatment in a dose-dependent manner. All cells treated with Sanguisorbae Radix showed increased dose- and time-dependent apoptosis. The expression of caspase 3, 8, 9, p53, and p21 was increased in all cells after the treatment of Sanguisorbae Radix. The expression of Bcl-2 was decreased in SNU-1196 and Bax expression was increased in all cells after the treatment of Sanguisorbae Radix. Conclusions : These results suggest that Sanguisorbae Radix would be beneficial in the treatment of cholangiocarcinoma.

Fabrication and Simulation of Fluid Wing Structure for Microfluidic Blood Plasma Separation

  • Choe, Jeongun;Park, Jiyun;Lee, Jihye;Yeo, Jong-Souk
    • Applied Science and Convergence Technology
    • /
    • v.24 no.5
    • /
    • pp.196-202
    • /
    • 2015
  • Human blood consists of 55% of plasma and 45% of blood cells such as white blood cell (WBC) and red blood cell (RBC). In plasma, there are many kinds of promising biomarkers, which can be used for the diagnosis of various diseases and biological analysis. For diagnostic tools such as a lab-on-a-chip (LOC), blood plasma separation is a fundamental step for accomplishing a high performance in the detection of a disease. Highly efficient separators can increase the sensitivity and selectivity of biosensors and reduce diagnostic time. In order to achieve a higher yield in blood plasma separation, we propose a novel fluid wing structure that is optimized by COMSOL simulations by varying the fluidic channel width and the angle of the bifurcation. The fluid wing structure is inspired by the inertial particle separator system in helicopters where sand particles are prevented from following the air flow to an engine. The structure is ameliorated in order to satisfy biological and fluidic requirements at the micro scale to achieve high plasma yield and separation efficiency. In this study, we fabricated the fluid wing structure for the efficient microfluidic blood plasma separation. The high plasma yield of 67% is achieved with a channel width of $20{\mu}m$ in the fabricated fluidic chip and the result was not affected by the angle of the bifurcation.

A Method of Frequent Structure Detection Based on Active Sliding Window (능동적 슬라이딩 윈도우 기반 빈발구조 탐색 기법)

  • Hwang, Jeong-Hee
    • Journal of Digital Contents Society
    • /
    • v.13 no.1
    • /
    • pp.21-29
    • /
    • 2012
  • In ubiquitous computing environment, rising large scale data exchange through sensor network with sharply growing the internet, the processing of the continuous stream data is required. Therefore there are some mining researches related to the extracting of frequent structures and the efficient query processing of XML stream data. In this paper, we propose a mining method to extract frequent structures of XML stream data in recent window based on the active window sliding using trigger rule. The proposed method is a basic research to control the stream data flow for data mining and continuous query by trigger rules.

A Study on the Reliability Analysis for Smoke Detector using Dust (분진을 이용한 연기감지기 신뢰성 분석에 관한 연구)

  • Hong, Sung Ho;Choi, Moon Soo;Lee, Young Man
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.6
    • /
    • pp.11-16
    • /
    • 2013
  • This paper presents a study on the analyzing reliability of smoke fire detector using accelerated life test. In general, the smoke fire detector is broken by dust which flow in smoke detection chamber. In order to conduct accelerated life test of smoke fire detector dust is set accelerated factor in this paper. The dust is fly-ash which is test particle 5th regulated by KS A 0090. The dust accelerated level is 60 g, 180 g and 360 g and failure time is measured by smoke sensitivity testing. It is considered to failure of detector if detector don't operate within 30 secconds when subjected to an air stream having a velocity of 20 cm/s~40 cm/s containing smoke with a concentration of 15% of rate of light-response of 1 m. The goodness of fit test and mean life prediction conduct using the failure time. The result show that life distribution fits the weibull distribution for failure time data and the mean lifes calculate 22.5 year in domestic product and 14.7 years in overseas product applied dust stress only.

Preconcentration and Determination of Fe(III) from Water and Food Samples by Newly Synthesized Chelating Reagent Impregnated Amberlite XAD-16 Resin

  • Tokahoglu, Serife;Ergun, Hasan;Cukurovah, Alaaddin
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.7
    • /
    • pp.1976-1980
    • /
    • 2010
  • A simple and reliable method has been developed to selectively separate and concentrate trace amounts of Fe(III) ions from water and food samples by using flame atomic absorption spectrometry. A new reagent, 5-hydroxy-4-ethyl-5,6-di-pyridin-2-yl-4,5-dihydro-2H-[1,2,4] triazine-3-thione, was synthesized and characterized by using FT-IR spectroscopy and elemental analysis. Effects of pH, concentration and volume of elution solution, sample flow rate, sample volume and interfering ions on the recovery of Fe(III) were investigated. The optimum pH was found to be 5. Eluent for quantitative elution was 10 mL of 2 M HCl. The preconcentration factor of the method, detection limit (3s/b, ${\mu}gL^{-1}$) and relative standard deviation values were found to be 25, 4.59 and 1%, respectively. In order to verify the accuracy of the method, two certified reference materials (TMDA 54.4 lake water and SRM 1568a rice flour) were analyzed. The results obtained were in good agreement with the certified values. The method was successfully applied to the determination of Fe(III) ions in water and food samples.

Preconcentration and Determination of Copper(II) Using Octadecyl Silica Membrane Disks Modified by 2-Propylpiperidine-1-carbodithioate and Flame Atomic Absorption Spectrometry (2-Propylpiperidine-1-carbodithioate로 수식화한 Octadecyl 실리카 막으로 구리(II)의 예비농축 및 불꽃 원자흡수분광법으로의 정량)

  • Moghimi, Ali;Mossalayi, Haydar
    • Journal of the Korean Chemical Society
    • /
    • v.52 no.2
    • /
    • pp.148-154
    • /
    • 2008
  • A simple and fast method for extraction and determination of trace amounts of copper(II) ions using octadecyl-bonded silica membrane disks modified with 2-propylpiperidine-1-carbodithioate (PPCD)I and atomic absorption spectrometry (AAS) is introduced. Extraction efficiency and the influence of flow rates, pH, and type and smallest amount of stripping acid were investigated. Maximum capacity of the membrane disks modified with 2 mg of the anthraquinone derivative used was found to be 425μg Cu2+. The limit of detection of the proposed method is 7 ng/ml. The method is applied to the recovery of Cu2+ from different synthetic samples and a spring water sample.

Transparent Conductors for Photoelectric Devices

  • Kim, Joondong;Patel, Malkeshkumar;Kim, Hong-Sik;Yun, Ju-Hyung;Kim, Hyunki
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.87.2-87.2
    • /
    • 2015
  • Transparent conductors are commonly used in photoelectric devices, where the electric energy converts to light energy or vice versa. Energy consumption devices, such as LEDs, Displays, Lighting devices use the electrical energy to generate light by carrier recombination. Meanwhile, solar cell is the only device to generate electric energy from the incident photon. Most photoelectric devices require a transparent electrode to pass the light in or out from a device. Beyond the passive role, transparent conductors can be employed to form Schottky junction or heterojunction to establish a rectifying current flow. Transparent conductor-embedded heterojunction device provides significant advantages of transparent electrode formation, no need for intentional doping process, and enhanced light-reactive surface area. Herein, we present versatile applications of transparent conductors, such as NiO, ZnO, ITO in photoelectric devices of solar cells and photodetectors for high-performing UV or IR detection. Moreover, we also introduce the growth of transparent ITO nanowires by sputtering methods for large scale application.

  • PDF

Speciation of Cr(III)/Cr(VI) in Tannery Waste Waters by Using Ion-Exchange Resins

  • Kartal, S.;Tokalloglu, S.;Ozkan, B.
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.5
    • /
    • pp.694-698
    • /
    • 2006
  • A method has been described for the chemical speciation, preconcentration and determination of Cr(III) and Cr(VI) species in filtered tannery waste waters by flame atomic absorption spectrometry using ion-exchange resins. Amberlite IR-120($H^+$) strongly acidic cation exchanger and Amberlite IRA-410($CI ^-$) strongly basic anion exchanger resins were used for the separation and preconcentration of Cr(III) and Cr(VI) species, respectively. Optimum condition for preconcentration and speciation was obtained by testing pH of sample and eluent, flow rates of sample and eluent, amount of resins, volume of sample and eluents, and effect of foreign ions. The recommended method has been successfully applied for the preconcentration and determination of chromium species in the dissolved phase of waste water samples collected from a tannery waste water treatment plant in Kayseri, Turkey. The detection limits achieved were 0.73 $\mu$g/L for Cr(III) and 0.81 $\mu$g/L for Cr(VI). Recovery studies showed 99% for Cr(III) and 98% for Cr(VI), for samples spiked with single species.

Reliability Assesment Test on the Regular Maintenance of HTS Cable System (초전도케이블시스템 유지.보수에 따른 신뢰성 평가 시험)

  • Sohn, Song-Ho;Yang, Hyung-Suk;Lim, Ji-Hyun;Choi, Ha-Ok;Kim, Dong-Lak;Ryoo, Hee-Suk;Hwang, Si-Dole
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.361-361
    • /
    • 2009
  • KEPCO High Temperature Superconducting (HTS) cable system rated with $3\Phi$, 22.9kV, 1250A was laid in 2006, and the long term test is in progress. The HTS cable system with the cooling system has been operated below cryogenic temperature. That environment exposes the system to the thermo-mechanical stress due to the significant temperature difference, and the cooling system has moving parts for the forced circulation of the coolant. Therefore the HTS cable system experiences thermal fatigue and moving part such as liquid nitrogen pump need a regular replacement every 5000 hours Building the assessment criterion, the maintenance procedure was established and regular preventive maintenance was done; improvement of the termination structure and the replacement of the bearing of liquid nitrogen pump. Following the proper process, the reliability assessment test including He leakage detection and the stability of flow rate was performed. This paper describes the process and result of the first regular maintenance of KEPCO HTS cable system

  • PDF