• Title/Summary/Keyword: Flow Detection

Search Result 1,247, Processing Time 0.031 seconds

Detecting Credit Loan Fraud Based on Individual-Level Utility (개인별 유틸리티에 기반한 신용 대출 사기 탐지)

  • Choi, Keunho;Kim, Gunwoo;Suh, Yongmoo
    • Journal of Intelligence and Information Systems
    • /
    • v.18 no.4
    • /
    • pp.79-95
    • /
    • 2012
  • As credit loan products significantly increase in most financial institutions, the number of fraudulent transactions is also growing rapidly. Therefore, to manage the financial risks successfully, the financial institutions should reinforce the qualifications for a loan and augment the ability to detect a credit loan fraud proactively. In the process of building a classification model to detect credit loan frauds, utility from classification results (i.e., benefits from correct prediction and costs from incorrect prediction) is more important than the accuracy rate of classification. The objective of this paper is to propose a new approach to building a classification model for detecting credit loan fraud based on an individual-level utility. Experimental results show that the model comes up with higher utility than the fraud detection models which do not take into account the individual-level utility concept. Also, it is shown that the individual-level utility computed by the model is more accurate than the mean-level utility computed by other models, in both opportunity utility and cash flow perspectives. We provide diverse views on the experimental results from both perspectives.

Determination Method of Signal Timing Plan Using Travel Time Data (통행시간 자료를 이용한 신호시간계획의 결정 방법)

  • Jeong, Young-Je
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.3
    • /
    • pp.52-61
    • /
    • 2018
  • This research suggested the traffic signal timing calculation model for signal intersections based on sectional travel time. A detection system that collects sectional travel time data such as Urban Transport Information System(UTIS) is applied. This research developed the model to calculate saturation flow rate and demand volume from travel time information using a deterministic delay model. Moreover, this model could determine the traffic signal timings to minimize a delay based on Webster model using traffic demand volume. In micro simulation analysis using VISSIM and its API ComInterface, it checked the saturation conditions and determined the traffic signal timings to minimize the intersection delay. Recently, sectional vehicle detection systems are being installed in various projects, such as Urban Transportation Information System(UTIS) and Advanced Transportation Management System(ATMS) in Korea. This research has important contribution to apply the traffic information system to traffic signal operation sector.

Validation and Determination of Glycyrrhizic Acid as a Marker Substance in Bu-Zhong-Yi-Qi-Tang by HPLC/DAD (HPLC/DAD에 의한 보중익기탕 중의 글리시리진산 정량분석법의 확립)

  • Baek, Ju-Hyun;Kim, Sun-Min;Ahn, Ji-Won;Cho, Chang-Hee;Oh, Mi-Hyune;Cho, Jung-Hee;Lee, Mi-Kyeong;Kim, Hyo-Jin
    • YAKHAK HOEJI
    • /
    • v.52 no.1
    • /
    • pp.7-11
    • /
    • 2008
  • A high performance liquid chromatographic (HPLC) method for the determination of glycyrrhizic acid was developed for the quality control of traditional herbal medicinal preparation Bu-Zhong-Yi-Qi-Tang (BZYQT), which is well-known herbal medicine used as tonic. RP-HPLC analysis was carried out using Capcell pak $C_{18}$ MG column $(5\;{\mu},\;150{\times}4.6\;mm)$ and a mobile phase consisting of acetonitrile and water containing 0.03% phosphoric acid (pH 2.46) at a flow rate of 1.0 ml/min. The optimum wavelength for the detection of the glycyrrhizic acid was found at 250 nm using diode-array UV/VIS detector. The glycyrrhizic acid in BZYQT shows good linearity $(r^2>0.999)$ in the range of $15\;{\mu}g/ml$ to 500 ${\mu}g/ml$. The limit of detection (LOD) was less than 5 ng and R.S.D for intra-day and inter-day reproducibility was less than 7%. The mean recovery of the glycyrrhizic acid was $97.3{\sim}113.0%$. These results suggest that the developed HPLC method is simple and efficient, and could be contributed for the quality control of commercial BZYQT products.

Design and Fabrication of Mold Insert for Injection Molding of Microfluidic tab-on-a-chip for Detection of Agglutination (응집반응 검출을 위한 미세 유체 Lab on a chip의 사출성형 금형 인서트의 디자인 및 제작)

  • Choi, Sung-Hwan;Kim, Dong-Sung;Kwon, Tai-Hun
    • Transactions of Materials Processing
    • /
    • v.15 no.9 s.90
    • /
    • pp.667-672
    • /
    • 2006
  • Agglutination is one of the most commonly employed reactions in clinical diagnosis. In this paper, we have designed and fabricated nickel mold insert for injection molding of a microfluidic lab-on-a-chip for the purpose of the efficient detection of agglutination. In the presented microfluidic lab-on-a-chip, two inlets for sample blood and reagent, flow guiding microchannels, improved serpentine laminating micromixer(ISLM) and reaction microwells are fully integrated. The ISLM, recently developed by our group, can highly improve mixing of the sample blood and reagent in the microchannel, thereby enhancing reaction of agglutinogens and agglutinins. The reaction microwell was designed to contain large volume of about $25{\mu}l$ of the mixture of sample blood and reagent. The result of agglutination in the reaction microwell could be determined by means of the level of the light transmission. To achieve the cost-effectiveness, the microfluidic lab-on-a-chip was realized by the injection molding of COC(cyclic olefin copolymer) and thermal bonding of two injection molded COC substrates. To define microfeatures in the microfluidic lab-on-a-chip precisely, the nickel mold inserts of lab-on-a-chip for the injection molding were fabricated by combining the UV photolithography with a negative photoresist SU-8 and the nickel electroplating process. The microfluidic lab-on-a-chip developed in this study could be applied to various clinical diagnosis based on agglutination.

Simulation of Elastic Wave Propagation in Anisotropic Materials (이방성 재료에서의 탄성파 전파 과정에 대한 시뮬레이션)

  • Kim, Young-H.;Lee, Seung-S.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.17 no.4
    • /
    • pp.227-236
    • /
    • 1997
  • Quantitative analysis and imaging of elastic wave propagation are very important for the materials evaluation as well as flaw detection. The elastic wave propagation in an anisotropic media is more complex, and analysis and imaging become essential for flaw detection and materials evaluation. In the anisotropic media, the wave velocity is dependent on the propagation direction. In addition, the direction of group velocity is different from that of phase velocity, the direction of energy flow is not same as the propagation direction of wavefront (beam skewing effect). Especially, this effect becomes critical for the large anisotropic media such as fiber composite materials, and the results using elastic waves for those materials have to be analyzed considering the wave propagation mechanism. Since the analytical approach for the wave propagation in the anisotropic materials is limited, the numerical analysis such as finite difference method (FDM) have been used for these case. Therefore, 2-dimensional FDM program for the elastic wave propagation is developed, and wave propagation in anisotropic media are simulated.

  • PDF

Statistical Techniques based Computer-aided Diagnosis (CAD) using Texture Feature Analysis: Applied of Cerebral Infarction in Computed Tomography (CT) Images

  • Lee, Jaeseung;Im, Inchul;Yu, Yunsik;Park, Hyonghu;Kwak, Byungjoon
    • Biomedical Science Letters
    • /
    • v.18 no.4
    • /
    • pp.399-405
    • /
    • 2012
  • The brain is the body's most organized and controlled organ, and it governs various psychological and mental functions. A brain abnormality could greatly affect one's physical and mental abilities, and consequently one's social life. Brain disorders can be broadly categorized into three main afflictions: stroke, brain tumor, and dementia. Among these, stroke is a common disease that occurs owing to a disorder in blood flow, and it is accompanied by a sudden loss of consciousness and motor paralysis. The main types of strokes are infarction and hemorrhage. The exact diagnosis and early treatment of an infarction are very important for the patient's prognosis and for the determination of the treatment direction. In this study, texture features were analyzed in order to develop a prototype auto-diagnostic system for infarction using computer auto-diagnostic software. The analysis results indicate that of the six parameters measured, the average brightness, average contrast, flatness, and uniformity show a high cognition rate whereas the degree of skewness and entropy show a low cognition rate. On the basis of these results, it was suggested that a digital CT image obtained using the computer auto-diagnostic software can be used to provide valuable information for general CT image auto-detection and diagnosis for pre-reading. This system is highly advantageous because it can achieve early diagnosis of the disease and it can be used as supplementary data in image reading. Further, it is expected to enable accurate medical image detection and reduced diagnostic time in final-reading.

Generation of Anti-HLA-DR4 Specific Antibodies by Immunization of the Recombinantly Expressed Allelic Subtype-Specific Region of the $HLA-DRB1^*0405$ Molecules

  • Park, Jung-Hyun;Cho, Eun-Wie;Lee, Yun-Jung;Chung, Jin;Hahm, Kyung-Soo;Kim, Kil-Lyong
    • BMB Reports
    • /
    • v.31 no.2
    • /
    • pp.111-116
    • /
    • 1998
  • HLA-DR4 is the dominant allele of MHC class II genes in Koreans. In particular, the $DRB1^*0405$ subtype has been reported to be almost exclusively expressed in Far East Asians, and has also been observed to be strongly associated with rheumatoid arthritis in Koreans and the Japanese. Identification of this specific allele has been mainly performed by PCR-based methods, which is often time consuming, costly, and involves tedious procedures such as the isolation of genomic DNA, PCR, and gel electrophoresis. To develop a more convenient tool for screening vast amounts of samples as well as to generate reagents which might also be used in other applications, in this study, antibodies were produced against this specific HLA subtype. By PCR, an allelespecific region covering the ${\beta}1$ domain of $DRB1^*0405$ was amplified and recombinantly expressed in E.coli. Immunization of Lewis rats with the purified protein yielded an allele specific antiserum. Western blot analysis showed the selective detection of the HLA-DR ${\beta}-chain$. Using this antiserum, established cell lines and peripheral blood lymphocytes were analyzed on their HLA haplotype by fluorescence activated flow cytometry. These novel antibodies will provide a powerful tool in the detection and investigation of DR4 alleles.

  • PDF

Measurement of Spatial Traffic Information by Image Processing (영상처리를 이용한 공간 교통정보 측정)

  • 권영탁;소영성
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.2 no.2
    • /
    • pp.28-38
    • /
    • 2001
  • Traffic information can be broadly categorized into point information and spatial information. Point information can be obtained by chocking only the presence of vehicles at prespecified points(small area), whereas spatial information can be obtained by monitoring large area of traffic scene. To obtain spatial information by image processing, we need to track vehicles in the whole area of traffic scene. Image detector system based on global tracking consists of video input, vehicle detection, vehicle tracking, and traffic information measurement. For video input, conventional approaches used auto iris which is very poor in adaptation for sudden brightness change. Conventional methods for background generation do not yield good results in intersections with heave traffic and most of the early studies measure only point information. In this paper, we propose user-controlled iris method to remedy the deficiency of auto iris and design flame difference-based background generation method which performs far better in complicated intersections. We also propose measurement method for spatial traffic information such as interval volume/lime/velocity, queue length, and turning/forward traffic flow. We obtain measurement accuracy of 95%∼100% when applying above mentioned new methods.

  • PDF

Rapid Quantitative Analysis of Vancomycin in Human Plasma and Urine Using LC-MS/MS (LC - MS/MS를 이용한 혈장과 뇨중에서 Vancomycin의 빠른정량분석)

  • Kim, Hohyun;Roh, Hyeongjin;Han, Sang-Beom
    • Analytical Science and Technology
    • /
    • v.15 no.5
    • /
    • pp.410-416
    • /
    • 2002
  • In this study, a new quantitative analytical method has been developed for the rapid determination of vancomycin in human plasma and urine using liquid chromatography/tandem mass spectrometry (LC - MS/MS). Chromatography was carried out on a $C_{18}$ XTerra MS column ($2.1{\times}30mm$) with a particle size of $3.5{\mu}m$. The mobile phase was 0.25% formic acid in 10% acetonitrile and the flow rate was $250{\mu}L/min$. Vancomycin and caffeine (internal standard) were detected by MS/MS using multiple reaction monitoring (MRM). Vancomycin gives a predominant doubly protonated precursor molecule ($[M+2H]^{2+}$) at m/z 725.0 and a corresponding product ion of m/z 100.0. Detection of vancomycin was good, accurate and precise, with a limit of detection of 1 nM in plasma. The calibration curves for vancomycin in human plasma was linear in a concentration range of $0.01{\mu}M$ - $100{\mu}M$ for plasma. This method has been successfully applied to determine the concentration of vancomycin in human plasma and urine from pharmacokinetic study and relative studies.

Simultaneous Determination of Six Components in the Traditional Herbal Medicine 'Oryeongsan' by HPLC-DAD and LC-MS/MS

  • Lee, Jiwoo;Weon, Jin Bae;Lee, Bohyoung;Yun, Bo-Ra;Eom, Min Rye;Ma, Choong Je
    • Natural Product Sciences
    • /
    • v.19 no.1
    • /
    • pp.20-27
    • /
    • 2013
  • A simple high performance liquid chromatography - diode array detector (HPLC-DAD) method has been developed and validated for simultaneous determination of the six components (cinnamic acid, cinnamaldehyde, eugenol, atractylenolide I, atractylenolide III, and ergosterol) in Oryeongsan. In addition, identification of six marker compounds was conducted by a LC-MS/MS analysis. The six compounds in Oryeongsan were separated on Shishedo $C_{18}$ column (5 ${\mu}m$, $4.6{\times}250$ mm) at a column temperature of $30^{\circ}C$. The mobile phase was a mixture of 0.1% trifluoroacetic acid (TFA) water and acetonitrile employing gradient elution at a flow rate of 1.0 mL/min. The detection wavelength was set at 205, 250, 280, and 330 nm. The developed method had good linearity ($R^2$ > 0.9997) and the limit of detection (LOD) and limit of quantification (LOQ) were observed within the ranges 0.01~0.15 and 0.05~0.45 ${\mu}g/mL$, respectively. The relative standard deviation (RSD) values of intra- and inter-day testing were indicated that less than 3% and 90.31~103.31% of accuracy. The results of recovery test were 90.56~106.72% and RSD range was measured from 0.84 to 2.95%. In conclusion, this HPLC-DAD method has been successfully applied to the simultaneous determination of six compounds in Oryeongsan samples.