• Title/Summary/Keyword: Flow Assurance

Search Result 66, Processing Time 0.03 seconds

A Study on Implementing the QC Tools for Systematic Problem-Solving (문제해결을 위한 QC 도구의 체계적 활용방안에 대한 연구)

  • Yun, Tae-Hong;Kim, Chang-Yeol;Byun, Jai-Hyun
    • Journal of Korean Society for Quality Management
    • /
    • v.37 no.2
    • /
    • pp.68-77
    • /
    • 2009
  • There are many quality control(QC) tools useful for solving quality problems. In this paper, QC 7 tools, new QC 7 tools, and other quality tools are first compared with respect to their frequency of use. We suggest an integrated problem-solving procedure to systematically deal with various quality problems. For each step a streamlined flow chart is presented to help the practitioners to adopt relevant tools depending on certain situations they face. The procedure will help quality practitioners solve field quality problems.

Neural Network Approach to Automated Condition Classification of a Check Valve by Acoustic Emission Signals

  • Lee, Min-Rae;Lee, Joon-Hyun;Song, Bong-Min
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.6
    • /
    • pp.509-519
    • /
    • 2007
  • This paper presents new techniques under development for monitoring the health and vibration of the active components in nuclear power plants, The purpose of this study is to develop an automated system for condition classification of a check valve one of the components being used extensively in a safety system of a nuclear power plant. Acoustic emission testing for a check valve under controlled flow loop conditions was performed to detect and evaluate disc movement for valve failure such as wear and leakage due to foreign object interference in a check valve, It is clearly demonstrated that the evaluation of different types of failure types such as disc wear and check valve leakage were successful by systematically analyzing the characteristics of various AE parameters, It is also shown that the leak size can be determined with an artificial neural network.

Quality Assurance of Patients for Intensity Modulated Radiation Therapy (세기조절방사선치료(IMRT) 환자의 QA)

  • Yoon Sang Min;Yi Byong Yong;Choi Eun Kyung;Kim Jong Hoon;Ahn Seung Do;Lee Sang-Wook
    • Radiation Oncology Journal
    • /
    • v.20 no.1
    • /
    • pp.81-90
    • /
    • 2002
  • Purpose : To establish and verify the proper and the practical IMRT (Intensity--modulated radiation therapy) patient QA (Quality Assurance). Materials and Methods : An IMRT QA which consists of 3 steps and 16 items were designed and examined the validity of the program by applying to 9 patients, 12 IMRT cases of various sites. The three step OA program consists of RTP related QA, treatment information flow QA, and a treatment delivery QA procedure. The evaluation of organ constraints, the validity of the point dose, and the dose distribution are major issues in the RTP related QA procedure. The leaf sequence file generation, the evaluation of the MLC control file, the comparison of the dry run film, and the IMRT field simulate image were included in the treatment information flow procedure QA. The patient setup QA, the verification of the IMRT treatment fields to the patients, and the examination of the data in the Record & Verify system make up the treatment delivery QA procedure. Results : The point dose measurement results of 10 cases showed good agreement with the RTP calculation within $3\%$. One case showed more than a $3\%$ difference and the other case showed more than $5\%$, which was out side the tolerance level. We could not find any differences of more than 2 mm between the RTP leaf sequence and the dry run film. Film dosimetry and the dose distribution from the phantom plan showed the same tendency, but quantitative analysis was not possible because of the film dosimetry nature. No error had been found from the MLC control file and one mis-registration case was found before treatment. Conclusion : This study shows the usefulness and the necessity of the IMRT patient QA program. The whole procedure of this program should be peformed, especially by institutions that have just started to accumulate experience. But, the program is too complex and time consuming. Therefore, we propose practical and essential QA items for institutions in which the IMRT is performed as a routine procedure.

A RANS modeling of backward-facing step turbulent flow in an open channel (개수로에서의 후향단차 난류 흐름 RANS 수치모의)

  • Kim, Byungjoo;Paik, Joongcheol
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.2
    • /
    • pp.147-157
    • /
    • 2022
  • The backward-facing step (BFS) is a benchmark geometry for analyzing flow separation occurred at the edge and resulting development of shear layer and recirculation zone that are occupied by turbulent flow. It is important to accurately reproduce and analyze the mean flow and turbulence statistics of such flows to design physically stable and performance assurance structure. We carried out 3D RANS computations with widely used, two representative turbulence models, k-ω SST and RNG k-ε, to reproduce BFS flow at the Reynolds number of 23,000 and the Froude number of 0.22. The performance of RANS computations is evaluated by comparing numerical results with an experimental measurement. Both RANS computations with two turbulence models appear to reasonably well reproduce mean flow in the shear layer and recirculation zone, while RNG k-ε computation results in about 5% larger velocity between the outer edge of boundary layer and the free surface above the recirculation zone than k-ω SST computation and experiment. Both turbulence models underestimate the shear stress distribution experimentally observed just downstream of the sharp edge of BFS, while shear stresses computed in the boundary layer downstream of reattachment point are agree reasonably well with experimental measurement. RNG k-ε modeling reproduces better shear stress distribution along the bottom boundary layer, but overestimates shear shear stress in the approaching boundary layer and above the bottom boundary layer downstream of the BFS.

Building Transparency on the Total System Performance Assessment of Radioactive Repository through the Development of the FEAS Program (FEAS 프로그램 개발을 통한 방사성폐기물 처분장 종합 성능 평가(TSPA) 투명성 증진에 관한 연구)

  • 서은진;황용수;강철형
    • Tunnel and Underground Space
    • /
    • v.13 no.4
    • /
    • pp.270-278
    • /
    • 2003
  • Transparency on the Total System Performance Assessment (TSPA) is the key issue to enhance the public acceptance for a permanent high level radioactive repository. Traditionally, the study on features, events and processes (FEPs) and associated scenarios has been regarded as the starting point to open the communicative discussion on TSPA such as what to evaluate, how to evaluate and how to translate outcomes into more friendly language that many stakeholders can easily understand and react with. However, in most cases, it has been limited to one way communication, because it is difficult for stakeholders outside the performance assessment field to assess the details on the story of the safety assessment, scenario and technical background of it. Fortunately, the advent of the internet era opens up the possibility of two way communication from the beginning of the performance assessment so that every stakeholder can exchange their keen opinions on the safety issues. To achieve it, KAERI develops the systematic approach from the FEPs to Assessment methods flow chart. All information is integrated into the web based program named FEAS (FEp to Assessment through Scenario development) under development in KAERI. In parallel, two independent systems are also under development the web based QA(Quality Assurance) system and the PA(Performance Assessment) input database. It is ideal to integrate the input data base with the QA system so that every data in the system can checked whenever necessary. Throughout the next phase R&D starting from the year 2003, these three systems will be consolidated into one unified system.

A Study of Carry Over Contamination in Chematology (이월오염에 대한 연구)

  • Chang, Sang-Wu;Kim, Nam-Yong;Lyu, Jae-Gi;Jung, Dong-Jin;Kim, Gi-You;Park, Yong-Won;Chu, Kyung-Bok
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.37 no.3
    • /
    • pp.178-184
    • /
    • 2005
  • Carry over contamination has been reduced in some systems by flushing the internal and external surfaces of the sample probe with copious amount of diluent. It between specimens should be kept as small as possible. A built-in, continuous-flow wash reservoir, which allows the simultaneous washing of the interior and exterior of the syringe needles, addresses this issue. In addition, residual contamination can further be prevented through the use of efficient needle rinsing procedures. In discrete systems with disposable reaction vessels and measuring cuvets, any carry over is entirely caused by the pipetting system. In analyzers with reuseable cuvets or flow cells, carry over may arise at every point through which high samples pass sequentially. Therefore, disposable sample probe tips can eliminate both the contamination of one sample by another inside the probe and the carry over of in specimen into the specimen in the cup. The results of the applicative carry over experiment studied on 21 items for total protein (TP), albumin (ALB), total bilirubin (TB), alkaline phosphatase (ALP), aspratate aminotranferase (AST), alanine aminotranferase (ALT), gamma glutamyl transferase (GGT), creatinine kinase (CK), lactic dehydrogenase (LD), creatnine (CRE), blood urea nitrogen (BUN), uric acid (UA), total cholesterol (TC), triglyceride (TG), glucose (GLU), amylase (AMY), calcium (CA), inorganic phosphorus (IP), sodium (Na), potassium (K), chloride (CL) tests in chematology were as follows. Evaluation of process performance less than 1% in all tests was very good, but a percentage of ALB, TP, TB, ALP, CRE, UA, TC, GLU, AMY, IP, K, Na, and CL was 0%, implying no carry over. Other tests were ALT(-0.08%), GGT(-0.09%), CK(0.08%), LD(0.06%), BUN(0.12%), TG (-0.06%), and CA(0.89%).

  • PDF

An experimental study on the factors to improve the formation performance of gas hydrate (가스하이드레이트 제조성능 향상을 위한 영향인자 검토 연구)

  • Shin, Chang-Hoon;Kim, Yu-Na;Kwon, Ok-Bae;Park, Seung-Su;Han, Jeong-Min;Lee, Jeong-Hwan
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2989-2994
    • /
    • 2007
  • Gas hydrates are ice-like crystalline compounds that form under low temperature and elevated pressure conditions. Although hydrate formation can pose serious flow-assurance problems in the gas pipelines or facilities, gas hydrates present a novel means for natural gas storage and transportation with potential applications in a wide variety of areas. An important property of hydrates that makes them attractive for use in gas storage and transportation is their very high gas-to-solid ratio. In addition to the high gas content, gas hydrates are remarkably stable. The main barrier to development of gas hydrate technology is the lack of an effective method to mass produce gas hydrate in solid form. The first objective of this study is investigating the characteristics of gas hydrate formation related to several factors such as pressure, temperature, water-to-storage volume ratio, concentration of SDS, heat transfer and whether stirred or not respectively. And the second objective is clarifying the relation between the formation efficiency and each factor in order to find the proper way or direction to improve the formation performance.

  • PDF

A Study on the Selection of Test Scope and the Prioritization of Test Case Based on Modification Method for Regression Testing (변경 메서드 기반의 회귀 테스트 검증 범위 선택 및 검증 항목 우선순위 선정에 관한 연구)

  • Jung, Woo-Jin;Rah, Sang-Rin;Choi, Yong-Lak
    • Journal of Information Technology Services
    • /
    • v.14 no.2
    • /
    • pp.129-142
    • /
    • 2015
  • The purpose of this study is to suggest an effective regression testing method in order to minimize the scope of test resulting from the modification of software and to prevent mismatch of test case and test objects. As a way to improve the efficiency of regression testing which uses a change-centric testing technique, the method flow is analyzed and grasped through a static analysis based on source code in order to identify modified parts. After the order of priority is set according to the results of user action log-based dynamic analysis on identified regression testing objects, test effect can be raised by adjusting the order of priority using code complexity. Quality assurance coverage can be checked using the user action log suggested in this study, and the progress of test and whether or not each function has been verified can be checked, too. In addition, by minimizing test parts and adjusting the order of test, costs and time can be saved, making it possible to conduct regression testing effectively.

Characteristic evaluation of waxy oil behavior using vane rheometer (베인 레오미터를 이용한 왁스오일의 특성 연구)

  • Oh, Kyeong-Seok
    • Journal of the Korean Applied Science and Technology
    • /
    • v.32 no.3
    • /
    • pp.497-504
    • /
    • 2015
  • Apart from hydrates, asphaltenes, and inorganic minerals, paraffinic waxes are also very important in flow assurance area. Evaluation of wax gel behavior has been important as off-shore oil recovery becomes more popular in oil production. Restart after either planned or emergency shutdown requires pump operation in high pressure since a waxy oil forms troublesome gel. In this paper, vane method is introduced to determine wax gel strength by determining yield stress. Prediction of gel strength are discussed in qualitative and quantitative manners.

A Study on the Experimental Relation between Parameters for Determining Dry Film Thickness in the Application of Anti Corrosive Paint using Hydraulic Plural Component (이액형 도장기기를 이용한 방식 도장 시 건도막두께 결정인자들에 대한 실험적 상관관계 연구)

  • Yun, Won-Jun;Choi, Min-Gu;Lee, Sung-Goun;Lee, Yun-Sig;Heo, Byung-Dong
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.49 no.5
    • /
    • pp.433-439
    • /
    • 2012
  • Anticorrosive paint is the most widely used in shipbuilding and the dry film thickness is very important in terms of productivity and assurance of anticorrosive performance. However, it is difficult to achieve the recommended target film thickness because the dry film thickness depends on labor's skill in practice and is affected by a number of parameters, such as spray pressure, paint flow rate, tip size, spray distance, SVR(Solid Volume Ratio), etc. Present paper derives an empirical equation through the correlation analysis of parameters selected by spray experiments of anti corrosive painting in order to predict the coated status. Comparing the calculated results with practical data, we show that the empirical equation can successfully expect DFT(Dry Film Thickness).