• 제목/요약/키워드: Flotation process

Search Result 191, Processing Time 0.022 seconds

Treatment of Oil Contaminated Groundwater Using DAF and Fenton Oxidation Process (DAF와 펜톤 산화 공정을 이용한 유류 오염 지하수 처리)

  • Lee, Chaeyoung
    • Journal of the Korean GEO-environmental Society
    • /
    • v.11 no.10
    • /
    • pp.49-55
    • /
    • 2010
  • The oil spill occurred frequently due to probably the increased consumption of oil as the energy source and the raw materials of various chemicals. For the treatment of oil contaminated groundwater, DAF(Dissolved Air Flotation) is being used but the removal efficiency is low. Therefore it is necessary to reduce the free phase oil, oil-in water type or water-in oil type emulsified oil, and soluble oil which are the main sources of contaminated groundwater. In this study, treatment of contaminated groundwater was performed using the Fenton oxidation process. The optimum conditions for the removal of THP(Total Petroleum Hydrocarbon) were 3 of pH, 25mM of $H_2O_2$ concentration and 25mM of $Fe^{2+}$ concentration. THP and COD(Chemical Oxygen Demand) concentrations decreased less than 1.5mg/L and 40.0mg/L in 7 minutes using DAF and Fenton oxidation process. However it is necessary to install the settling basin as the sludge concentration increased approximately 5 times.

Pre-treatment of oily wastewater using a coagulation-DAF process with slit-nozzle (슬릿노즐기반 응집·공기부상공정을 통한 유류폐수 전처리)

  • Choi, Sangki;Kim, Youngmo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.6
    • /
    • pp.479-485
    • /
    • 2018
  • Large amounts of oily wastewater discharged from various industrial operations (petroleum refining, machinery industries and chemical industries) cause serious pollution in the aquatic environment. Although dissolved air flotation (DAF) separating oil pollutants using microbubbles represents current practice, bubble size cannot be selectively controlled, and lots of power is required to generate microbubbles. Therefore, to investigate performance of the DAF process, this study examined the distribution of different sizes of microbubbles resulting from changes in physical shear force via modifying shapes of a slit-nozzle without an additional power supply. Three types of slit-nozzles (different angle, shape and length of the slit-nozzle) were used to analyze the distribution of bubble size. At a slit angle of $60^{\circ}$, shear force was 4.29 times higher than a conventional slit, and particle size distribution (PSD) in the range between 2 and $20{\mu}m$ more than doubled. Treatment efficiency of synthetic oily wastewater through the coagulation-DAF process achieved 90% removal of COD by injecting $FeCl_3$ and PACl of 250 mg/L and 100 mg/L, respectively, and the same performance resulted using $FeCl_3$ of 200 mg/L and PACl of 80 mg/L employing a slit-nozzle angle of $60^{\circ}$. This study shows that a coagulation-DAF process using a modified slit-nozzle can improve the pre-treatment of oily wastewater.

A study on Flotation of Crystalline Graphite by Microbubble Column (Microbubble Column에 의한 인상흑연(鱗狀黑鉛)의 부선(浮選)에 관한 연구(硏究))

  • Han, Oh-Hyung;Kang, Hyun-Ho
    • Resources Recycling
    • /
    • v.15 no.2 s.70
    • /
    • pp.37-44
    • /
    • 2006
  • The total amount of graphite reserves in Korea is about 260 thousand tons. Graphite larks international competitiveness it is mined in only few mines, but recently the demand of portable electronic has increased. Therefore a research for manufacturing domestic high purity graphite is necessary because all of high purity graphite used electrode of 2nd batter depends on expensive importation. A preprocessing level for producing high purity graphite, flotation was conducted using microbubble column machine. In this research $D_{50}=10.314{\mu}m$ sample was used which was produced after grinding 29.50% F.C. primary crushing sample($D_{50}=69.393{\mu}m$) for 20 minutes through attrition mill. As a result using this sample, product above 95% F.C. with recovery over 90% was obtained with only after first stage process through the microbubble column.

A Comparative Study of Turbulence Models for Dissolved Air Flotation Flow Analysis (용존공기부상법 유동해석을 위한 난류모델 비교연구)

  • Park, Min A;Lee, Kyun Ho;Chung, Jae Dong;Seo, Seung Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.7
    • /
    • pp.617-624
    • /
    • 2015
  • The dissolved air flotation (DAF) system is a water treatment process that removes contaminants by attaching micro bubbles to them, causing them to float to the water surface. In the present study, two-phase flow of air-water mixture is simulated to investigate changes in the internal flow analysis of DAF systems caused by using different turbulence models. Internal micro bubble distribution, velocity, and computation time are compared between several turbulence models for a given DAF geometry and condition. As a result, it is observed that the standard ${\kappa}-{\varepsilon}$ model, which has been frequently used in previous research, predicts somewhat different behavior than other turbulence models.

Treatment of Contaminated Groundwater Containing Petroleum and Suspended Solids Using DAF and Mixed Coagulation Processes (DAF와 혼화응집공정을 이용한 현탁성 고형물 함유 유류 오염 지하수 처리)

  • Lee, Chaeyoung;Jang, Yeongsu
    • Journal of the Korean GEO-environmental Society
    • /
    • v.11 no.8
    • /
    • pp.25-32
    • /
    • 2010
  • Contamination of soil and groundwater by the compounds of hydrocarbon petroleum has been widely accepted as the main cause that harms the environments and health. To remove those pollutants, absorbing clothes, activated carbons, or oil-water separation devices with the gravity method are employed for treatment. However, those materials and devices cannot remove the emulsion pollutants despite of their efficiency for removing free products. Therefore, we investigated the problems which occur during the groundwater treatment for the highly concentrated suspended solid particles, which can be resulted from excavation, and to propose methods to remove TPH(Total Petroleum Hydrocarbon). After coagulation experiment with high molecular polymers, the concentration of SS(Suspended Solids) and COD(Chemical Oxygen Demand) turned to satisfy the groundwater quality criteria within 5 minutes while the concentration of TPH failed to meet the water quality standard of effluent. Consequently, the water quality criteria for effluent could not be met by single DAF(Dissolved Air Flotation) process. However all water quality criteria could be satisfied after 20 minutes when coagulation reactions are carried out simultaneously in the DAF reactor.

An Investigation into Ultrasonic Flotation Separation of Spent MgO-C Refractories Using Acetic Acid (아세트산을 활용한 폐 마그카본(MgO-C) 내화물의 초음파 부상 분리에 관한 연구)

  • Yunki Byeun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.12 no.1
    • /
    • pp.40-46
    • /
    • 2024
  • A novel approach is presented to address issues associated with the use of strong acidic solutions for the leaching of magnesium oxide (MgO) from spent magnesia-carbon refractories. An ultrasonic flotation and separation process is employed, with a mildly acidic solvent, acetic acid, used to selectively chelate MgO from the spent refractories. When using 2 M acetic acid as a solvent, the recovery of the graphite exhibited 99.7 % with high purity of 72.7 %, showing a significant improvement compared to using water as the solvent. Furthermore, the technology presented in this study offers a method for producing magnesium acetate through the reaction of MgO in spent refractory with acetic acid, providing a means for the purification and separation of graphite.

Development History and Direction of On-site Algae Collecting System with Flotation Technology (부상분리 기술을 이용한 현장형 조류수거시스템의 발전 과정 및 개발 방향)

  • Kim, Jong Ik;Han, Ihn Sup;Mei, Qi Wen;Cho, Chong Joo;Jung, Soon Woo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.4
    • /
    • pp.194-200
    • /
    • 2017
  • On-site Algae Collecting System (OACS) is one of urgent countermeasures to clean the raw water when the algae blooms severely. Rapid reaction capability, high efficiency and large capacity are required when applying OACS to large water areas. The total performance of OACS are always determined by unit process named Flotation, Trapping and Collection. The working efficiency and daily treatment quantity of OACS can be increased when it runs automatically. As the rapid development of OACS technology, in the first place, equipment are miniaturized and simple. And in the second place, automation process from Trapping to Collection are advanced. So, They produce results higher working efficiency, smaller residual sludge on treated water, system's advanced environmental friendly features and the increased amount of sludge by Collection process to achieve large capacity. Now OACS has overcome the algae multiplication rate to ensured the amount of removal algae. In another aspect, it is high economically feasible because of reducing operation cost against the large capacity.

Study on Phosphorus Removal in the Secondary Effluent by Flotation Using Microbubble Liquid Film System (미세기포 액막화 부상법을 이용한 하수 2차 처리수의 인 제거에 관한 연구)

  • Lee, Shun-Hwa;Kang, Hyun-Woo;Lee, Se-Han;Kwon, Jin-Ha;Jung, Kye-Joo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.1
    • /
    • pp.42-48
    • /
    • 2012
  • In this study, experiment on phosphorus removal was performed by using microbubble liquid film flotation tank with microbubble module. After dissolving gas and liquid in dissolving tank, microbubble liquid film system created microbubbles in equal size under fixed low pressure. After being passed through $A_2O$ and m-$O_3$ process, secondary treatment wastewater was used as influent in phosphorus removal process. When the T-P concentration of influent was 2.89 mg/L, alum(8%, 30 mg/L) was injected into a microbubble flotation tank, the treatment resulted 94% of T-P removal rate. Remaining T-P concentration was less than 0.2 mg/L, which is in accord with the effluent quality standard. Seasonal variations in water temperature showed no differences in T-P removal property. When the inflow concentration of SS was 1.0 mg/L or more, it served as coagulation nuclei in the coagulation process. In that condition, average T-P removal rate was higher than 97%. When 50% of floated scum was returned, coagulator Al included in scum assisted the injected coagulator and maximized the coagulation efficiency of pollutant. In such treatment, the T-P concentration was measured as 0.18 mg/L and satisfied the outflow water quality standard, which is 0.2 mg/L or less.

Treatment Characteristics and Application of DAF Process for Effective Solid Separation in BNR Municipal Wastewater Treatment System (BNR 하수처리시스템에서 효과적 고형물 분리를 위한 DAF 공정의 적용과 처리특성)

  • Kwak, Dong-Heui;Rhu, Dae-Hwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.3
    • /
    • pp.267-276
    • /
    • 2010
  • Many plants have been improved to adapt the target of the biological treatment processes changed from organics to nutrients since the water quality criteria of effluent was reinforced and included T-N and T-P for the municipal wastewater treatment plant. To meet the criteria of T-N and T-P, the conventional biological reactor such as aeration tank in activated sludge system is changed to the BNR (biological nutrient removal) processes, which are typically divided into three units as anaerobic, anoxic and oxic tank. Therefore, the solid separation process should be redesigned to fit the BNR processes in case of the application of the DAF (dissolved air flotation) process as an alternatives because the solid-liquid separation characteristics of microbial flocs produced in the BNR processes are also different from that of activated sludge system as well. The results of this study revealed that the microbial floc of the anaerobic tank was the hardest to be separated among the three steps of the unit tanks for the BNR processes. On the contrary, the oxic tank was best for the removal efficiency of nutrients as well as suspended solid. In addition, the removal efficiency of nutrients was much improved under the chemical coagulation treatment though coagulation was not indispensable with a respect to the solid separation. On the other hand, in spited that the separation time for the microbial floc from the BNR processes were similar to the typical particles like clay flocs, over $2.32{\times}10^3$ ppm of air volume concentration was required to keep back the break-up of the bubble-floc agglomerates.

A Study on the Elimination of Microcystis sp. using Microbubble (미세기포를 이용한 Microcystis sp. 제거에 관한 연구)

  • Hyung, Sung-Hee;Lee, Kap-Du;Park, Sang-Won
    • Journal of Environmental Science International
    • /
    • v.25 no.3
    • /
    • pp.425-438
    • /
    • 2016
  • This study carried out zeta potential measurements of the Microcystis sp. under various solutions condition and investigated the characteristics of Microcystis sp. through the size control of microbubbles to eliminate algae that causes problems in aquatic ecosystems and human activities. DAF process was adopted and several coagulants were used to remove the Microcystis sp. CCD Camera was used to measure and analyze the size of microbubble, and fluorescent microscope was used to observe the particle, algae species and community. Zeta potential behavior of the algae was analyzed by using ELS-Z. Lab-scale and pilot-scale experiments were conducted to test flotation process. Polyaluminium chloride(PAC) coagulant was used, and the removal efficiency of the algae was assessed through Chlorophyll-a analysis. In the Lab-scale experiment, 2.2 ppm, 11 ppm, 22 ppm, and 44 ppm of polyaluminium chloride was injected to coagulate the algae. The coagulated algae was floated by the microbubble. The microbubbles in the experiments were generated at a air pressure of 450 ~ 550 kPa. The microbubble size was controlled in $36{\mu}m$, $100{\mu}m$, and $200{\mu}m$, respectively by using different diffuser. The results of lab-scale experiments on flotation plant indicated that the average removal rate was about 90% or above for 11 ppm, 22 ppm, and 44 ppm of polyaluminium chloride. On the other hand, in the pilot-scale experiment, the removal efficiency was in the range of 85% to 95% in all dose ranges of polyalumium chloride and aluminium sulfate coagulants.