• 제목/요약/키워드: Flotation process

검색결과 190건 처리시간 0.026초

Fundamental Structure in Simultaneous Removal for Phytoplankton and Nutrient Salt in Lakes

  • SEKI, Tatsuhiro;ISHII, Yuuichi;ISHII, Toshio;TAKI, Kazuo
    • Environmental Engineering Research
    • /
    • 제14권4호
    • /
    • pp.220-225
    • /
    • 2009
  • The water quality in eutrophic lakes is affected by serious problems, such as abnormal increasing of Cyanobacteria. The purpose of this study was to investigate the possibility of a modified flotation system using a hybrid technique formed by chemical compounds and an electrostatic bridge. Therefore, experiments using the hybrid technique were performed to measure the zeta potential value on the phytoplankton surface and the removal efficiencies of phytoplankton, ammonia nitrogen, nitrate nitrogen and phosphoric acid. The results were as follows: Firstly, the zeta potential of M.aeruginosa was observed to approach charge neutralization due to adhesion of magnesium hydroxide precipitate on the phytoplankton surface in the pH range 10.5 to 11. Secondly, the concentration of chlorophyll-a decreased from about 150 to 20${\mu}g$g/L, with a maximum removal efficiency of 84% due to coagulation with pH values higher than 10. Thirdly, the N$H_4$-N concentration was observed to decrease from 0.62 to 0.54mg-N/L (13%), and the P$O_4$-P concentration, which is a limiting factor to the formation of algae blooms, decreased from 0.27 to 0.02mg-P/L (92%). These findings suggest that the modified flotation system can be applied for the purification of the raw water of numerous lakes containing high phytoplankton populations and elevated pH.

양이온성 고분자로 처리한 무기입자에 대한 플렉소그라피 잉크의 흡착 (Adsorption of Flexography Ink on Inorganic Particles Patched with Cationic Polymer)

  • 정영빈;김진우;오규덕;윤혜정;이학래
    • 펄프종이기술
    • /
    • 제44권5호
    • /
    • pp.8-13
    • /
    • 2012
  • The flexography ink has disadvantage in a deinking process because it tends to form too fine particles in alkali condition to be removed in flotation deinking. The influence of pH conditions on the particle size of phthalocyanine cyan ink used for flexo-printing was investigated to see the effect of pH conditions on flexography ink dispersion. Flexography ink particles prepared by grinding dried ink films were used in this experiment. Greater reduction of the ink particle size was noticed under alkaline pH condition, which was attributed to dissolution of resin component of the ink. Adsorption behavior of flexography ink onto pigment particles was examined using clay and talc as substrate pigments. Pretreatment of inorganic pigments with a cationic poly-DADMAC increased the surface adsorption of flexography ink particles, which improved the removal of the inks by centrifugal sedimentation of inorganic pigments. Most efficient removal of the ink particles was achieved when an optimal addition level of the cationic polymer was used for pretreatment of inorganic pigments, and this optimal addition level corresponds to the surface saturation point of the polyelectrolyte. Adsorption of flexography ink particles onto inorganic pigments improved the ink removal in flotation deinking since the pigment particles has the optimal particle size for flotation deinking.

DAF 공정에서 공기포화장치와 노즐 특성 별 미세기포 발생에 미치는 영향 (An Effect of the Micro Bubble Formation Depending on the Saturator and the Nozzle in the Dissolved Air Flotation System)

  • 박상철;오호영;정몽규;송석용;안용희
    • 대한환경공학회지
    • /
    • 제35권12호
    • /
    • pp.929-936
    • /
    • 2013
  • DAF (Dissolved air flotation) 공정에서 공기포화장치(Saturator)와 미세기포 발생노즐은 미세기포 형성에 중요한 영향을 미치는 장치이다. 미세기포 발생 효율을 증가시키기 위해서는 공기포화장치 용기 안에서 기-액 접촉 효율을 증가시키고, 미세기포 발생노즐까지 이송 배관 내 압력을 일정하게 유지해 주어야 한다. 본 연구에서는 공기포화장치 내 순환수 유입 분사노즐과 포화수 이송 배관, 미세기포 발생노즐에 의한 미세기포 발생에 미치는 영향을 공기체적법과 기포 크기, 기포의 잔류시간 측정을 통해 비교해 보았다. 순환수 유입 분사노즐을 설치하고, 포화수의 이송 배관 내 압력손실이 발생하지 않는 구조, 미세기포 발생노즐의 통과유속을 증가시킬 경우 미세기포 발생 성능이 증가하였다.

전기응집/부상 공정을 이용한 염료 처리에 중심합성설계와 반응표면분석법의 적용 (Application of the Central Composite Design and Response Surface Methodology to the Treatment of Dye using Electrocoagulation/flotation Process)

  • 김동석;박영식
    • 한국물환경학회지
    • /
    • 제26권1호
    • /
    • pp.35-43
    • /
    • 2010
  • This experimental design and response surface methodology (RSM) have been applied to the investigation of the electrocoagulation/flotation of dye wastewater. The electrocoagulation/flotation reactions were mathematically described as a function of parameters current (A), NaCl concentration (B), initial RhB concentration (C) and time (D) being modeled by use of the central composite design (CCD). The application of RSM using the CCD yielded the following regression equation, which is an empirical relationship between the RhB removal (%) and test variables in RhB removal (%) = $-300.42+129.21{\cdot}Current+46.99{\cdot}NaCl-0.11{\cdot}RhB-+43.71{\cdot}Time-5.67{\cdot}Current{\cdot}NaCl-3.18{\cdot}Current{\cdot}Time-2.41{\cdot}NaCl{\cdot}Time-19.79{\cdot}Current^2-2.27{\cdot}NaCl^2-1.59{\cdot}Time^2$. the model predictions agreed well with the experimentally observed result ($R^{2}=0.9728$). The estimated ridge of maximum response and optimal conditions for RhB removal (%) using canonical analysis was 99.4% (A: 1,77 A, NaCl concentration: 2.23 g/L, RhB concentration: 56.12 mg/L, Time: 9.98 min). To confirm this optimum condition, three additional experiments were performed and RhB removal (%) were within range of 86.87% (95% PI low)~111.93% (95% PI high) obtained.

백운모광의 품위향상에 관한 연구 (A study on the Beneficiation of Muscovite Ore)

  • 이재장;최수용
    • 산업기술연구
    • /
    • 제9권
    • /
    • pp.29-41
    • /
    • 1989
  • A general study on the upgrading of mica minerals which are mainly found in pegmatite deposits was carried out for the purpose of developing a technique for recovering mica in form of comercial grade products. By the way the grade one of about 5~6% $K_2O$ still is not developed. The target of this research work is to be establish a process for the efficient concentration of muscovite, containing more than 10% $K_2O$. The tests are applied to incraese the recovery and grade of concentrates in term of variations of conditions. The test sample consists of mainly muscovite and gangue mineral such as quartz, pyrite and chlorite. Decantation and shaking table tests were ineffective to up-grade this low grade one, but flotation method gave satisfactory result. By means of grade one, but flotation method gave satisfactory result. By means of grindability tests, an optimum result could be obtained from the sample ground to -48mesh feed size. The flotation result indicates that the dodecyl ammonium chloride used as a cationic collector is effective on the negatively charged surface, while the sodium dodecyl sulfate as an anionic collector is effective on the positively charged surface. Muscovite was floated by petroleum sulfonate as well as amine type collector, it also floated by MIBC as well as pine oil frother under well condition. Fine muscovite concentrates of about 10.68% $K_2O$ was obtained with 22.4% yield, by decantation, the muscovite concentrates of 10.10% $K_2O$ was obtained with 23.54% yield, by table concentration, the muscovite concentrates of 11.51% $K_2O$ was obtained with 23.0% yield by flotation.

  • PDF

Flotation-Spectrophotometric Determination of Ag(I) at the 10-7 mol L-1 Level Using Iodide and Ferroin as an Ion-associate

  • Hosseini, Mohammad Saeid;Hashemi-Moghaddam, Hamid
    • Bulletin of the Korean Chemical Society
    • /
    • 제26권10호
    • /
    • pp.1529-1532
    • /
    • 2005
  • A simple and cost effective method for separation and preconcentration of Ag(I) at the $10^{-7}\;mol\;L^{-1}$ level in the environmental and mineral samples is present. The method is based on the flotation of Ag(I)-iodide complex as an ion-associate with ferroin in pH of 4 from a large volume of an aqueous solution (500 mL) using nheptane. The floated layer was then dissolved in dimethylsulfoxide (DMSO) for the subsequent spectrophotometric determination. Beer's law was obeyed over a range of 2.0 ${\times}$ $10^{-7}$-4.0 ${\times}$ $10^{-6}$ mol $L^{-1}$ with the apparent molar absorptivity of 2.67 ${\times}$ $10^5$ L $mol^{-1}\;cm^{-1}$. The detection limit (n = 5) was 4 ${\times}$ $10^{-8}$ mol $L^{-1}$, and RSD (n = 5) obtained for 2.0 ${\times}$ $10^{-6}$ mol $L^{-1}$ of Ag(I) was 2.2%. The interference effects of a number of elements was studied and found that only $Hg^{2+}$ at low concentration, and $Pb^{2+}$, $Cd^{2+}$, $Cu^{2+}$, and $Fe^{3+}$ ions at moderately high concentrations were interfered. To overcome on these interference effects, the solution was treated with EDTA at a buffering pH of 4 and passed through a column containing Amberlite IR-120 ionexchanger resin, just before the flotation process. The proposed method was applied to determine of Ag(I) in a synthetic waste water, a photographic washing sample and a geological sample and the results was compared with those obtained from the flame atomic absorption spectrometry. The results were satisfactorily comparable with together, so that the applicability of the proposed method was confirmed in encountering with the real samples.

Recovery Process for the Recycling of Waste Carbon Black

  • Lee, Sungoh;Nampyo Kook;Tam Tran;Bangsup Shin;Kim, Myongjun
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 The 6th International Symposium of East Asian Resources Recycling Technology
    • /
    • pp.215-219
    • /
    • 2001
  • Impurities removal from waste carbon black was carried out to produce high-grade carbon black. A lot of hydrophilic carbon black is produced as a byproduct of the hydrogen production process by flame decomposition of water. Due to its impurity content such as sulphur, iron, ash and etc., it can only be used as low-grade carbon or burnt out. High-grade hydrophilic carbon black is 3-5 times more expensive than oil-based carbon black because of its process difficulties and requires pollutant treatment. Hydrophilic carbon is normally used far conductive materials for batteries, pigment for plastics, electric wire covering, additives for rubber, etc.. In these applications, hydrophilic carbon must maintain its high purity. In this study magnetic separation, froth flotation and ultrasonic treatment were employed to remove impurities from the low-grade hydrophilic carbon black. As results, the ash, iron and sulphur content of product decreased to less than 0.01wt.%, 0.0lwt.% and 0.3wt.% respectively, and the surface area of product was about 930 $m^2$/g.

  • PDF

DAF 펌프를 이용한 실규모 용존공기부상 공정의 전처리 조건 (Pretreatment Condition in the Full Scale Dissolved Air Flotation Process Using a DAF Pump)

  • 이창한;안대명;김성수;조석호;안갑환
    • 대한환경공학회지
    • /
    • 제31권1호
    • /
    • pp.58-63
    • /
    • 2009
  • 용존공기부상(Dissolved Air Flotation)은 조류, 휴믹물질, 및 저밀도 입자가 포함된 원수의 처리에서 침전지보다 우수한 성능을 가지는 공정이다. 본 연구는 실험실과 실규모의 DAF 펌프형 시스템을 이용하여 정수처리공정의 전처리(응집/응결) 조건에 따른 처리효율을 비교하여 나타하였다. 실규모 DAF 펌프형 시스템(Full scale DAF pump system ; F-DAF)은 처리용량과 수력학적 부하량을 각각 5,000 톤/일과 10 m/hr이며, F-DAF는 D 정수장의 원수에서 전처리(혼화/응집) 및 운전성능을 최적화하기 위해 운전하였다. 실험실 규모의 실험결과는 원수 탁도 13.8~56.3 NTU에서 최적 PSO-M 주입량은 2.7~4.5 mL/$m^3$/NTU이었다. 이와같이 최적 응집제 주입 조건에서 유출수의 탁도를 1.0 NTU 이하로 1개월 동안 유지하며 F-DAF의 운전이 가능하였다.

인쇄용지 재활용을 위한 형광증백제 탈착에 대한 기초연구 (Study on the Detachment of Fluorescent Whitening Agents from White Waster Papers)

  • 이지영;김철환;김은혜;박태웅
    • 펄프종이기술
    • /
    • 제48권2호
    • /
    • pp.5-12
    • /
    • 2016
  • White waste papers are very important resources in the paper industry, but their use is limited because of the residual of fluorescent whitening agent (FWA). So the removal of FWAs from waste paper is an important task in the recycling process to improve the use of recycled resources. In this study, we focused on the FWAs used for surface treatments and carried out physical and chemical treatments to remove them from white waste papers. The white waste papers were disintegrated with a surfactant in different pH and temperature conditions, and then handsheets were made for the measurement of the fluorescence index, which is proportional to the amount of FWAs on papers. The effect of the flotation process on the removal of FWAs after disintegration was also investigated. The fluorescence index decreased as the disintegration time increased, but over a relatively long time, the fluorescence index increased again, which indicated the readsorption of the FWAs detached from the cellulosic fibers of the white waste papers. The lowest fluorescence index was shown when the waste papers were disintegrated with a 0.3% surfactant addition at pH 10 and at $45^{\circ}C$. However, the flotation treatment was not effective, because the flotation induced contact between the detached FWAs and the cellulosic fibers, and re-adsorption occurred.

메시형 알루미늄 전극을 이용한 전기응집/부상 공정에서 Kaoline의 탁도 제거 (Turbidity Removal of Kaolin in an Electrocoagulation/Flotation Process Using a Mesh-type Aluminum Electrode)

  • 정창;김동석;박영식
    • 한국환경과학회지
    • /
    • 제26권5호
    • /
    • pp.563-572
    • /
    • 2017
  • The Electrocoagulation-Flotation (ECF) process has great potential in wastewater treatment. ECF technology is effective in the removal of colloidal particles, oil-water emulsion, organic pollutants such as microalgae, and heavy metals. Numerous studies have been conducted on ECF; however, many of them used a conventional plate-type aluminum anode. In this study, we determined the effect of changing operational parameters such as power supply time, applied current, NaCl concentration, and pH on the turbidity removal efficiency of kaoline. We also determined the effects of different electrolyte types (NaCl, $MgSO_4$, $CaCl_2$, $Na_2SO_4$, and tap water), as well as the differences caused by using a plate-type and mesh-type aluminum anode, on the turbidity removal efficiency. The results showed that the optimal values of ECF time, applied current, NaCl concentration, and pH were 5 min, 0.35 A, 0.4 g/L NaCl in distilled water, and pH 7, respectively. The results also revealed that the turbidity removal efficiency of kaoline in different electrolytes decreased in the following sequence, given the same conductivity: tap water > $CaCl_2$ > $MgSO_4$ > NaCl > $Na_2SO_4$. The turbidity removal efficiency of the mesh-type aluminum anode was significantly greater than the plate-type aluminum anode.