• Title/Summary/Keyword: Flotation

Search Result 398, Processing Time 0.028 seconds

Numerical Analysis on Dynamic Behavior Characteristics of an Amphibious Assault Vehicle during Water Entry (상륙돌격장갑차의 진수 중 동적 거동 수치 해석)

  • Youngmin Heo;Taehyung Kim
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.26 no.2
    • /
    • pp.159-170
    • /
    • 2023
  • In the present study, the dynamic behavior characteristics of an amphibious assault vehicle during water entry were analyzed using STAR-CCM+, a commercial computational fluid dynamics(CFD) code. All computations were performed using an overset mesh system and a RANS based flow-solver coupled with dynamic fluid-body interaction(DFBI) solver for simulating three degrees of freedom motion. For numerical validation of the solver, a water entry simulation of inclined circular cylinder was conducted and it was compared between an existing experiment data and CFD results. The pitch angle variation and the trajectory of the circular cylinder during water entry shows good agreement with previous experimental and numerical studies. For the water entry simulations of the amphibious assault vehicle, the analysis of dynamic behaviors of the amphibious assault vehicle with different slope angles, submerged depths and initial velocities were conducted. It is confirmed that the steep slope angle increases the submerged volume of the amphibious assault vehicle, so the buoyancy acting on the vehicle is increased and the moved distance for the re-flotation is decreased. It is also revealed that the submerged volume is increased, bow-up phenomenon occur earlier.

Evaluation of microplastics reduction effects using Dissolved Air Floatation and Brown-gas (용존공기부상법과 브라운가스를 이용한 미세플라스틱 저감효과 평가)

  • Kim, Taekyoung;Jeong, Hanseok
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.474-474
    • /
    • 2022
  • 미세플라스틱이 물 환경으로 배출되는 주요 경로로는 하수처리장 방류수와 강우유출수가 있다. 하수처리장 및 유역에서 배출된 미세플라스틱은 하천과 하구역을 거쳐 해양과 같은 대규모 수역으로 이동하는데, 이 과정에서 해양뿐만 아니라 담수호, 저수지 등과 같은 공공수역에도 미세플라스틱이 지속적으로 축적되고 있다. 특히 강우유출수에 포함된 미세플라스틱은 적절한 처리 과정 없이 하천으로 유입되는 경우가 많아 공공수역 내 미세플라스틱 저감 기술의 필요성이 증가하고 있다. 그러나 미세플라스틱 관련 기존 연구는 미세플라스틱의 분포 등 현황에 대한 모니터링 및 환경위해성과 관련한 것이 대부분이며, 미세플라스틱 저감기술 관련 연구 또한 일부 정수처리 및 하수처리 공정을 대상으로 하는 초기 단계의 연구가 진행되고 있을 뿐 공공수역에서의 미세플라스틱 저감기술 개발 관련 연구는 전무한 실정이다. 따라서, 본 연구에서는 기존의 물리·화학적 수처리 공정인 용존공기부상법(Dissolved Air Flotation, DAF)에 물의 전기분해 시발생하는 브라운가스를 활용하여 응집된 물질을 빠르게 부상시켜 수체 내 오염물질을 제거할 수 있는 기술을 통해 수체 내 미세플라스틱 저감효과를 분석하였다. 또한, 해당 기술을 공공수역인 저수지에 적용하여 오염물질과 함께 미세플라스틱을 제거할 수 있는지 검토하였다.

  • PDF

Online analysis of iron ore slurry using PGNAA technology with artificial neural network

  • Haolong Huang;Pingkun Cai;Xuwen Liang;Wenbao Jia
    • Nuclear Engineering and Technology
    • /
    • v.56 no.7
    • /
    • pp.2835-2841
    • /
    • 2024
  • Real-time analysis of metallic mineral grade and slurry concentration is significant for improving flotation efficiency and product quality. This study proposes an online detection method of ore slurry combining the Prompt Gamma Neutron Activation Analysis (PGNAA) technology and artificial neural network (ANN), which can provide mineral information rapidly and accurately. Firstly, a PGNAA analyzer based on a D-T neutron generator and a BGO detector was used to obtain a gamma-ray spectrum dataset of ore slurry samples, which was used to construct and optimize the ANN model for adaptive analysis. The evaluation metrics calculated by leave-one-out cross-validation indicated that, compared with the weighted library least squares (WLLS) approach, ANN obtained more precise and stable results, with mean absolute percentage errors of 4.66% and 2.80% for Fe grade and slurry concentration, respectively, and the highest average standard deviation of only 0.0119. Meanwhile, the analytical errors of the samples most affected by matrix effects was reduced to 0.61 times and 0.56 times of the WLLS method, respectively.

Collecting of Hanji Fibrous Sludge with Surfactant (계면활성제를 이용한 한지 섬유질 슬러지의 제거)

  • Choi, Hee-Seon;Kim, Tai-Jin
    • Analytical Science and Technology
    • /
    • v.14 no.2
    • /
    • pp.167-172
    • /
    • 2001
  • The technique that could collect efficiently the hanji fibrous sludge from wastewater using surfactants was developed. When fibrous sludge of which concentration was about 80mg/L, was floated and collected, the optimum concentration of sodium oleate, the pore size of glass filter and the air flow rate were 10mg/L, $5-10{\mu}m$ and 200mL/min., respectively. The behavior of sodium oleate might be interfered by polyvalent cations such as $Ca^{2+}$. But when the concentration of $Ca^{2+}$ was less than 100mg/L, the interference effect did not appear. And when a typical cationic surfactant, cetyltrimethylammonium bromide(CTAB), was used, the collecting yield was less than that of sodium oleate, and the amount of foam was higher than sodium oleate. When 1mg/L of CTAB was added to the hanji sludge sample contained 1mg/L of $PAMID^{(R)}$, a dispersant, fibrous sludge was effectively coagulated, the flotation time was very short and the collecting yield was above 95%. But in the case, sodium oleate was inefficient.

  • PDF

A Study on the Treatment of Soil Flushing Effluent Using Electrofloatation : Effects of Electrolyte and pH (전기부상을 이용한 토양세정 유출수 처리에 관한 연구 : 전해질 및 pH의 영향)

  • 소정현;최상일;조장환
    • Journal of Soil and Groundwater Environment
    • /
    • v.8 no.3
    • /
    • pp.56-60
    • /
    • 2003
  • The optimal operation conditions of electrofloatation for oil-water separation of soil flushing effluent including electrolyte and pH were investigated. The reactor (200 ${\times}$ 10 ${\times}$ 15 cm) for the experiment was constructed by using acrylic plate. Diesel concentration was 1,000 mg/L in the 1 % mixed surfactant solution ($POE_5$: $POE_{14}$ 1: 1). Titanium coated electrode was used as cathode and stainless steel electrode as anode. Reaction time was 62 minutes (reaction time: 60 min., flotation time: 2 min.) and voltage was 6 V. The separation efficiency of electrofloatation was improved to 40% by electrolyte addition. Furthermore, NaCl (1N) added as electrolyte was showed enhanced efficiency compared to NaOH (1N). While, the effect of both NaCl and NaOH was sequentially increased in the range of 0.2∼1.0% (0.02∼0.1 M). The equilibrium time was found as 20 min. in the range of 0.4∼1.0% (0.04∼0.1M) for both of them.

Property Characterization and Lipid - Compositional Analysis of Lipid Granules Isolated from an Oleaginous Yeast Rhodotorula glutinis

  • Ham, Kyung-Sik;Rhee, Joon-Shick
    • Preventive Nutrition and Food Science
    • /
    • v.3 no.3
    • /
    • pp.211-215
    • /
    • 1998
  • Preparative isolation of lipid granules from Fhodotorula glutinis, which has been studied for long time to produce edible lipids, was carried out by flotation method in Ficoll-Linear density gradient. When the isolated lipid granules were suspended in a series of solutions containing varying concentration of osmotic stabilizer (sorbitoal and mannitol) ranging from 0.8M to 0M, the lipid granules appeared to be disrupted at a concentration between 0.8M and 0.7, and again at a concentration below 0.1M, suggesting that lipid granules have a membraneous structure and that at least two types of lipid granules are present. Compositional analysis of lipids from lipid granules revealed that lipids are composed mainly of neutral lipids (87.8% of total lipids), predominantly as triacylglycerols (71.89%). Marked differences were observed inphospholipids between lipids of lipid granules and those of whole cells . The major components of phospholipids in lipid granules and inwhole cells are phosphatidylcholine(38.6%) and phosphatidylserine(42.8%), respectively. In addition, significant differences were also observed in the fatty acid composition of phospholipids. As phospholipids are important structural components of membranes, these differences lead to the suggesting that the membrane of lipid granules may be distinct functionally and structurally from other membranes of yeast cells. The major fatty acid components of neutral lipidss of whole cells and lipid granules are palmitic , oleic and linoleic acid. However , degreeof fatty acid unsaturation of neutal lipids of lipid granules was much lower than that of neutral lipids of whole cells.

  • PDF

A Rat Liver Lysosomal Membrane Flavin-Adenine Dinucleotide Phosphohydrolase

  • Shin, Hae-Ja;Lim, Woon-Ki
    • BMB Reports
    • /
    • v.29 no.3
    • /
    • pp.253-260
    • /
    • 1996
  • An enzyme that hydrolyzes flavin-adenine dinucleotide (FAD) was found to be present in rat liver lysosomal membrane prepared from Triton WR-1339 filled lysosomes (tritosomes) purified by flotation on sucrose. This FAD phosphohydrolase (FADase) exhibited optimal activity at pH 8.5 and had an apparent Km of approximately 3.3 mM. The activity was decreased 50~70% by dialysis against EDTA and this was restored by $Zn^{2+}$, $Mg^{+2}$, $Hg^{+2}$, and $Ca^{+2}$ ions inhibited the enzyme, but $F^-$ and molybdate had no effect. The enzyme was also inhibited by p-chloromercuribenzoate (pCMB), reduced glutathione and other thiols, cyanide, and ascorbate. The presence of ATP, ADP, AMP. ${\alpha}-{\beta}-methylene$ ATP, AMP-p-nitrophenyl phosphate (PNP), GMP, and coenzyme A (CoA) decreased the activity on FAD, but pyrimidine nucleotides, adenosine, adenine, or $NAD^+$ were without effect. Phosphate stimulated the activity slightly. FAD phosphohydrolase activity was separated from ATPase and inorganic pyrophosphatase activities by solubilization with detergents and polyacrylamide gel electrophoresis and by linear sucrose density gradient centrifugation suggesting that the enzyme is different from ATPase, inorganic pyrophosphatase, and soluble lysosomal FAD pyrophosphatase. Paper chromatography showed that FAD was hydrolyzed to flavin mononucleotide (FMN) and AMP which were further hydrolyzed to riboflavin and AMP by phosphatases known to be present in lysosomal membranes. Incubation of the intact Iysosomes with pronase showed that the active site of FAD phosphohydrolase must be oriented to the cytosol. The FAD hydrolyzing activity was detected in Golgi, microsome, and plasma membrane, but not in mitochondria or soluble lysosomal preparations.

  • PDF

Air Pollution Protection onboard by Seawater and Electrolyte

  • An Suk-Heon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.1
    • /
    • pp.93-101
    • /
    • 2006
  • This research makes a new attempt to apply the activated seawater by electrolysis in the development of two-stage wet scrubber system to control the exhaust gas of large marine diesel engines. First, with using only seawater that is naturally alkaline (pH typically around 8.1). the $SO_2\;and\;SO_3$ are absorbed by relatively high solubility compared to other components of exhaust pollutants, and PM (Particulate Matter) is removed through direct contact with sprayed seawater droplets. Besides, the electrolyzed alkaline seawater by electrolysis, which contains mainly NaOH together with alkali metal ions $(i.e.\;Na^+,\;Mg^{2+},\;Ca^{2+})$, is used as the absorption medium of NOx and $CO_2$. Especially, to increase NOx absorption rate into the alkaline seawater. nitric oxide (NO) is adequately oxidized to nitrogen dioxide $(NO_2)$ in the acidic seawater, which means both volume fractions are adjusted to identical proportion. The results found that the strong acidic seawater was a valid oxidizer from NO to $NO_2$ and the strong alkaline seawater was effective in $CO_2$ absorption In the scrubber test, the SOx reduction of nearly $100\%$ could be achieved and also led to a sufficientPM reduction. Hence, the author believes that applying seawater and its electrolyte would bring the marine air pollution control system to an economical measure. Additionally it is well known that NOx and SOx concentration has a considerable influence on the $N_2O$ emission of green house gas. Although the $N_2O$ concentration exhausted from diesel engines is not as high, the green house gas effect is around 300 times greater than an equivalent volume of $CO_2$. Therefore, we investigated the $N_2O$ removal efficiency with using the electrolyzed seawater too. Finally this research would also plan to treat the effluent by applying electro-dialysis and electro-flotation technique s in the future.

Development of the Air Floating Conveyor System for the Large Glass Sheet (대평판 글라스 이송용 공기 부상 이송장치의 개발)

  • Lee, Tae Geol;Yu, Jin Sik;Jung, Hyo Jae;Kim, Jong-Hyeong;Kim, Joon Hyun
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.4
    • /
    • pp.635-642
    • /
    • 2013
  • We have prepared a DEMO conveyor device for conveying a large 8G class glass sheet using ahorizontal air-cushion system. This device consists of the body frame and the driving frame that are combined to realize a frame for conveying glass without any contact.The driving frame comprises an air flotation table (bed), drive roller supported at both ends, and ASU. Part of the ASU serves to control the airflow as the chamber consists of a porous pad and fan. Fiber filters replace the porous pad and axial fans serve as an air compressor. In addition, to determine the appropriate glass levitation from the air table, this study examined the design specifications of the applied filter (discharge speed of HEPA and ULPA filters, and flow rate) as well as the height of the and the proper supporting roller height (14mm). Then, after adjusting the position of the ASU and the number of ASUs required to configure the UNIT air floating C/V, we analyzed the height and flatness of the glass and derived the appropriate layout (1140-mm distance between ASUs).

Use of Home Nursing Therapy and Need of Home Care Equipments (가정간호환자의 치료적 간호서비스 제공과 의료기구 사용 및 요구도)

  • Ryu, Ho-Shin;Park, Chai-Soon;Kim, In-A;Kwon, Young-Dae;Kang, Sung-Wook
    • Research in Community and Public Health Nursing
    • /
    • v.19 no.2
    • /
    • pp.157-166
    • /
    • 2008
  • This study was conducted with whole home care nurses nationwide to provide secondary analyzed data to understand on their usage of medical equipments and their need of them for a month. This study found that treatments given by home care nurses were nelaton catheterization, bladder washing/urethral washing, newborn care, exchange and care for nasogastric tube and suction in that order of frequency. Second, instruments and equipments used for home care were reported to be stethoscope, patient monitor, blood pressure measuring equipment, air flotation mattresses, beds for patients, mattresses, suctioning device sets, enteral feeding equipment and dressing set in that oder of frequency. Moreover, need assessment of medical instruments and equipments showed renal dialysis was most needed and patient monitor, blood pressure measuring equipment, enteral feeding equipment, solution and other supplies for renal dialysis and beds for patient were necessary in that order. In conclusion, the results of this study investigating special treatments and medical instruments and equipments used for home care patients and analyzing patients' need, were expected to be useful for expansion of application of long-term care insurance for the elderly and health insurance as well as for quality control of home care and development of medial instruments and equipments used at home.

  • PDF