Development of Optimal TACT Process for Eco-Friendly Demolition Works in Aged Housing Remodeling - Focus on Case Study - (친환경 리모델링 철거공사의 최적 TACT공정 개발 - 사례연구를 중심으로 -)

  • Woo, Joong-Pyung;Kim, Ki-Hyun;Hwang, Young-Gyu;Kim, Kyung-Rai;Cha, Hee-Sung
    • Korean Journal of Construction Engineering and Management
    • /
    • v.12 no.1
    • /
    • pp.3-12
    • /
    • 2011
  • Technology based civilization has made a sustained advancement, resulting in economic growth and material prosperity. The outcome was the beginning of environmental destruction. Especially, in regard to construction, it has been recognized as a key culprit for pollution. As such, the construction industry has recently shown interest in the environment, as it has been applying environment friendly method of construction and reducing wastes. As the number of old common housing increases in our country, reconstruction and remodeling are implemented as a means of improvement. However, it can be said that remodeling is the inevitable option because of cost and environmental problems associated with reconstruction. As part of its feature, remodeling work is preceded by removal work. And, removal work inevitably creates construction wastes. Treatment of wastes that takes into consideration environmental aspects is important and for this, removal work that is based on environment friendly remodeling to ensure selective separation must be implemented. Yet, a removal work based on environment friendly remodeling has a lower level of output compared to existing methods. Because remodeling work by its nature has a post construction work which proceeds after it, securing work efficiency is important as the removal work is a critical path activity. Thus, the present study improves the work process of a removal work that is based on environment friendly remodeling so that it becomes a work process that includes work efficiency. For this, as a case study, old common housing has been selected, and a TACT process has been developed which is based on data acquired from environment friendly removal work. And, this study develops an optimal TACT process which is based on environment friendly remodeling by conducting a simulation for a 15 floor apartment.

Study on the Application of Semi-open cut Top-Down Construction for Framework (세미 오픈컷 역타공법의 현장적용에 관한 연구)

  • Sho, Kwang-Ho
    • Journal of Korean Association for Spatial Structures
    • /
    • v.11 no.2
    • /
    • pp.129-138
    • /
    • 2011
  • Construction methods for underground structure are classified as bottom-up, up-up, and top-down methods depending on the procedure of construction related to a superstructure. In top-down construction methods, building's main structure is built from the ground level downwards by sequentially alternating ground excavation and structure construction. In the mean time, the main structure is also used as supporting structure for earth-retaining wall, which results in the increased stability of the earth-retaining wall due to the minimized deformation in adjacent structures and surrounding grounds. In addition, the method makes it easy to secure a field for construction work in the downtown area by using each floor slabs as working spaces. However top-down construction method is often avoided since an excavation under the slab has low efficiency and difficult environment for work, and high cost compared with earth anchor method. This paper proposes a combined construction method where semi-open cut is selected as excavation work, slurry as earth -retaining wall and CWS as top-down construction method. In the case study targeted for an actual construction project, the proposed method is compared with existing top-down construction method in terms of economic feasibility, construction period and work efficiency. The proposed construction method results in increased work efficiency in the transportation of earth and sand, and steel frame erection, better quality management in PHD construction, and reduced construction period.

Characteristics of Planting Design according to Parking Lots Type in Multi-family Housing Complex (공동주택단지의 주차장 유형에 따른 식재특성)

  • Hong, Seong-Rae;Jeong, Dae-Young;Shim, Sang-Ryul
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.37 no.1
    • /
    • pp.43-49
    • /
    • 2009
  • The number of registered vehicles increased to one million in 1985 and ten million in 1997, and the parking lots in multi-family housing complex that had been mainly constructed on the ground level began to be constructed in underground levels. Therefore, planting design in such complex were greatly changed. This study classifies the parking lots in multi-family housing complexes located in Cheongju into three categories: above-ground, mixture of above-ground and underground, and underground. The characteristics of planting design in each were then analyzed. The rate of parking per family increased by two or more in the type of mixture when compared to in the type of above-ground. As underground parking lots became dominant, the rate of parking per family increased to one car or more. The green area ratio did not change considerably when above-ground parking was combined with underground parking, but the green area per total floor space was reduced, which indicates the quality of green area became lower. Most of the parking lots in multi-family housing complexes since 2000 have been constructed underground, and the green area became larger. As for the species of trees used in planting design, trees that are vulnerable to damage by blight and harmful insects and may be repugnant have been reduced and replaced by trees whose shapes are beautiful and whose flowers and fruits can be appreciated, such as Chionanthus retusa, Malus floribunda, Styrax japonicus, Prunus mume, Lagerstroemia indica. Pine trees are variously planted with diversified standards, and, in particular, tall pine trees are being utilized as focal points. Herbaceous flowers began to be planted in underground parking lots constructed since 2000, and they are expected to be planted even more due to the appreciation of their flowers and their splendid appearance.

Applicable Building Range for the Introduction of the Building Separation and Dismantling System (건축물 분별해체 제도 도입을 위한 적용 대상 건축물 범위 설정)

  • Park, Ji-Sun;Song, Tae-Hyeob;Choi, Dong-Ho
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.1 no.3
    • /
    • pp.189-196
    • /
    • 2013
  • In order for efficient recycling and eco-friendly treatment of construction waste, there is a need to apply a building separation and dismantling technique early on in the stage of waste generation. This study was conducted to analyze the relevant domestic circumstances and propose the applicable range of buildings in order to introduce a building separation and dismantling system to Korea. For this purpose, related policies and systems implemented overseas and the current situation of buildings were examined, and the workability of separation and dismantling of buildings according to their uses was compared. Also, the economic impact of the separation and dismantling system was examined and a survey was conducted, seeking the opinions of the relevant companies regarding the need for the system and the selection criteria for eligible buildings. Based on the results, it was determined that it would be impossible to apply the separation and dismantling system to all buildings in Korea, considering the current technical power and economic situation, and that the system should be introduced in phases, according to the building classification determined based on floor area and use, as the cost may vary depending on a number of variables including the level of difficulty and field conditions.

Output-Only System Identification and Model Updating for Performance Evaluation of Tall Buildings (초고층건물의 성능평가를 위한 응답의존 시스템판별 및 모델향상)

  • Cho, Soon-Ho
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.12 no.4
    • /
    • pp.19-33
    • /
    • 2008
  • Dynamic response measurements from natural excitation were carried out for 25- and 42-story buildings to evaluate their inherent properties, such as natural frequencies, mode shapes and damping ratios. Both are reinforced concrete buildings adopting a core wall, or with shear walls as the major lateral force resisting system, but frames are added in the plan or elevation. In particular, shear walls in a 25-story building are converted to frames from the 4th floor level downwards while maintaining a core wall throughout, resulting in a fairly complex structure. Due to this, along with similar stiffness characteristics in the principal directions, significantly coupled and closely spaced modes of motion are expected in this building, making identification rather difficult. By using various state-of-the-art system identification methods, the modal parameters are extracted, and the results are then compared. Three frequency-domain and four time-domain based operational modal identification methods are considered. Overall, all natural frequencies and damping ratios estimated from the different identification methods showed a greater consistency for both buildings, while mode shapes exhibited some degree of discrepancy, varying from method to method. On the other hand, in comparison with analysis results obtained using the initial finite element(FE) models, test results exhibited a significant difference of about doubled frequencies, at least for the three lower modes in both buildings. To improve the correlation between test and analysis, a few manual schemes of FE model updating based on plausible reasons have been applied, and acceptable results are obtained. The advantages and disadvantages of each identification method used are addressed, and some difficulties that might arise from the updating of FE models, including automatic procedures, for such large structures are carefully discussed.

A Study on the Incidence of Carbon Monoxide Poisoning (연탄(煉炭)가스중독(中毒)의 발생실태(發生實態)에 관(關)한 연구(硏究))

  • Cho, Soo-Hun;Shin, Young-Soo;Lee, Doek-Hyoung;Kim, Yong-Ik;Yun, Dork-Ro
    • Journal of Preventive Medicine and Public Health
    • /
    • v.18 no.1
    • /
    • pp.1-11
    • /
    • 1985
  • A decade ago a survey on the population-base incidence rate of anthracite coal gas (mainly carbon monoxide) poisonig in Seoul area was investigated, resulting in the incidence rate of 306/10,000 risk population and 1 death/10,000. Another survey on the carbon monoxide poisoning was investigated during 1 year period from Apr. 1983 to Mar. 1984. Total subjects of risk population were 67,740 households covering 353,287 persons. The major findings of this survey are as follows: 1. Household-base incidence rate was 8.4% spell-base 10.4%. 2. The incidence rate was the highest in houses having each of slate roof, cement wall, vinyl floor of bedroom and direct 'ondol' heating system. 3. Average 2.1 person was attacked from one incidence of the poisoning; severity-wise person-base incidence rates per 10,000 were 352 in mild poisoning, 54 in severe poisoning and 1.4 in death-overall incidence rate 407. Several facts were identified which supported that this figure was moderately underestimated. As the incidence of the poisoning is affected by socioeconomic and environmental factors, it is natural that one expects the incidence will decrease in proportion to genernal improvement of the above factors. Thus the results of these two surveys seemed preposterous. But further study suggested that the incidence rate (306/10,000) decade before had been significantly underestimated and corrected-rate should have been 478/10,000 level. 4. Age and sex distribution by the degree of the poisoning was uniform with little statistical difference; overall incidence rates by sex were 339/10,000 in male and 475/10,000 in female with significant statistical difference(p<.01). 5. 5.3% of the patients were treated at hospital or local clinic; 3.0% of the patients were hospitalized. Admission rate in comatose patient(severe poisoning) was 14.2%. In conclusion, carbon monoxide poisoning remains a major health problem by now.

  • PDF

A Study on the Characteristics of the Vegetation Structure and Location Environment of the Albizzia kalkora Community (왕자귀나무군락의 식생구조 및 입지환경 특성 연구)

  • Kim, Ji-Suk;Park, Seok-Gon
    • Korean Journal of Environment and Ecology
    • /
    • v.30 no.4
    • /
    • pp.783-792
    • /
    • 2016
  • The purpose of this study is to investigate the characteristics of the vegetation structure and the location environment of Albizzia kalkora (AK) growing in Mt. Yudal located in Mokpo city and in the nearby islands. The AK community in Mt. Yudal in Mokpo city (Community I) is located in a region which is relatively high above the sea level. The average age of the major kinds of trees found in the region is about 30 years. The vegetation structure in the community shows an early stage of vegetation development due to continued disturbance. In Community IV, on the sandy soil in the flatland near the seashores, the average age of the major kinds of trees is about 9 years. In this community, a pure forest is presumed to have been formed in a poor environment which is artificially disturbed in relatively recent times even as AK with its strong adoptability was introduced into the region. In other communities (II, III), the vegetation state shows a competition between AK and deciduous oak trees, and the average age of the major kinds of trees is about 13 to 30 years. AK communities with a better developed vegetation structure are located on the higher steep slopes near the seashore. In the early stage of vegetation development, the forest floor received more effective light for photosynthesis, and thus more seedlings of AK emerged and grew. The probability of AK appearing in the damaged or sterile soil near the seashore was high because of its strong adaptability. However, as the vegetation structure developed further and the soil fertility increased, the domination of AK in the vegetation structure decreased as deciduous oak trees won the competition with AK.

Study on Fatigue Behavior and Rehabilitation of Stringer with Coped Section(I) -Experimental Study on Static and Fatigue Behavior- (절취부를 갖는 세로보의 피로거동과 보수·보강에 관한 연구(I) -정적거동 및 피로거동의 실험적 고찰-)

  • Hwang, Yoon Koog;Chang, Dong Il
    • Journal of Korean Society of Steel Construction
    • /
    • v.9 no.3 s.32
    • /
    • pp.363-375
    • /
    • 1997
  • This study encompasses the performance of static and fatigue test for the 8 large scale test specimens to clarify the fatigue behavior of coped stringer and the effect of the repair and strengthening on the damaged stringer of the floor system in steel railway bridges. For the purpose of the research, the actual stress wave for the existing bridge was measured, the basic stress range frequency histogram was made and the equivalent stress range was calculated. Using the result from the equivalent stress range made by adjusting the stress range, the static and fatigue test was carried out by identifying the previous rehabilitation and after. As the result of the static tests, it was revealed that the level of local stress under the S1 specimen test of the real equivalent stress range was similar to tensile strength of the test material, and it was consistent with the requirement of the initiation condition of the fatigue crack. Through the various rehabilitation methods to the damaged specimens, the effects of the repair and reinforcement were analyzed. According to the results of the repair of effect, bolting the high tension bolt over the stop hole was confirmed to be more adequate method than drilling only stop hole to delay the fatigue crack growth. Futhermore, in case of the stringer subjected by bending moment, the reinforcement over the upper flange side was determined to be a useful strengthening method, and the reinforcement to the web of the stringer was not appropriate to accomodate as a adequate strengthening method. Also it was confirmed that the category of the fatigue design for the coped stringer met with the category E specified on the fatigue design criteria of the Highway Standard Specification in Korea.

  • PDF

Application of HACCP for Hygiene Control in University Foodservice Facility - Focused on Vegetable Dishes (Sengchae and Namul) - (대학급식시설의 위생관리개선을 위한 HACCP 적용에 관한 연구 - 생.숙채류를 중심으로 -)

  • 허영수;이복희
    • Journal of Food Hygiene and Safety
    • /
    • v.14 no.3
    • /
    • pp.293-304
    • /
    • 1999
  • The purpose of this study was to evaluate the microbiological quality, and to assure the hygienic safety of the food production in the university food service facility located in Seoul in accordance with the Hazard Analysis Critical Control Point(HACCP) concepts. In the hygienic state assessment of kitchen, it has revealed that it was very important to remove water from the kitchen floor and to establish standard method for disinfection of cooking utensils. And foodservice workers were required to have training program for the safe handling of food and utensils since they did treat food without hygienic gloves. The kitchen layout had to be improved because the near distance of table with heating unit and shelf might cause the growth of microorganisms when prepared food was kept on the shelf. In terms of the timetemperature measurement and microbiological quality assessment during each of the food production phases, most of sengchae (raw vegetable dish) and namul (cooked vegetable dish) were treated within danger zone for food safeness ($5~60^{\circ}C$). It has shown that the microbiological quality of raw materials was very much inferior at the time of receiving based on the TPC($10^{5}~10^{7}$), coliform($10^{3}~1O^{6}$), which was not acceptable level(TPC:$10^{6}$, coliform:$10^{3}$) suggested by Solberg. Microbiological growth has increased in the both of sengchae and namul considerably during most of food production phase. Therefore, it is extremely important to reduce holding and serving time and to avoid treating food within the danger zone for food safeness. In addition, the prevention of cross-contamination during mixing the ingredients with improper equipments and with insanitary treatments by workers was also important to keep the food safety in this speciqic university foodservice facility.

  • PDF

Effects of Pyridoxine on Growth Performance and Plasma Aminotransferases and Homocysteine of White Pekin Ducks

  • Xie, Ming;Tang, Jing;Wen, Zhiguo;Huang, Wei;Hou, Shuisheng
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.27 no.12
    • /
    • pp.1744-1748
    • /
    • 2014
  • A dose-response experiment with seven supplemental pyridoxine levels (0, 0.66, 1.32, 1.98, 2.64, 3.30, and 3.96 mg/kg) was conducted to investigate the effects of pyridoxine on growth performance and plasma aminotransferases and homocysteine of White Pekin ducks and to estimate pyridoxine requirement for these birds. A total of 336 one-day-old male White Pekin ducks were divided to 7 experimental treatments and each treatment contained 8 replicate pens with 6 birds per pen. Ducks were reared in raised wire-floor pens from hatch to 28 d of age. At 28 d of age, the weight gain, feed intake, feed/gain, and the aspartate aminotransferase, alanine aminotransferase, and homocysteine in plasma of ducks from each pen were all measured. In our study, the pyridoxine deficiency of ducks was characterized by growth depression, decreasing plasma aspartate aminotransferase activity and increasing plasma homocysteine. The ducks fed vitamin $B_6$-deficient basal diets had the worst weight gain and feed/gain among all birds and this growth depression was alleviated (p<0.05) when pyridoxine was supplemented to basal diets. On the other hand, plasma aspartate aminotransferase and homocysteine may be the sensitive indicators for vitamin $B_6$ status of ducks. The ducks fed basal diets had much lower aspartate aminotransferase activity and higher homocysteine level in plasma compared with other birds fed pyridoxine-supplemented diets (p<0.05). According to quadratic regression, the supplemental pyridoxine requirements of Pekin ducks from hatch to 28 days of age was 2.44 mg/kg for feed/gain and 2.08 mg/kg for plasma aspartate aminotransferase and the corresponding total requirements of this vitamin for these two criteria were 4.37 and 4.01 mg/kg when the pyridoxine concentration of basal diets was included, respectively. All data suggested that pyridoxine deficiency could cause growth retardation in ducks and the deficiency of this vitamin could be indicated by decreasing plasma aspartate aminotransferase activity and increasing plasma homocysteine.