• Title/Summary/Keyword: Floor heating

Search Result 398, Processing Time 0.029 seconds

A Study on Characteristics of Koreans' Housing Life Living in China (중국 거주 한국인의 주생활특성 연구)

  • Cho, Sung-Heui;Son, Jin-Hee
    • Journal of the Korean housing association
    • /
    • v.16 no.6
    • /
    • pp.9-19
    • /
    • 2005
  • It is possible to explain the design, the meaning, and the use of domestic space by comparing different cultures. The characteristics of Koreans' housing life living in western cultures has already been studied extensively. Because of political reasons, however, the characteristics of Koreans' housing life living in Chinese culture has hardly been studied at all. The purpose of this study was to find out the characteristics of succession and transformation of domestic housing culture. The data was collected by questionnaire methods from fifty Korean households and eleven Chinese households. Individual interviews and actual surveys, including taking pictures were also used for data collection. The results of this study were as follows (1)An analysis of heating system usage behaviors showed the importance of heated floors, known as Ondol, is one of the enduring characteristics of domestic habits. (2)In the sitting style, the traditional sitting on the floor was shown in living room. (3)Regarding room usage behavior, Korean households were centered around the living room in chinese houses. (4)An analysis of space organization preferences with respect to common spaces revealed that Korean households tend to prefer the open plan of common spaces.

Characteristices of Temperature Distribution in a Closed Space with Heat Source and Porous Horizontal Partition (유공성 수평격판을 가진 열원이 있는 밀폐공간내의 온도분포 특성)

  • Park, Chan-Su;Cho, Dae-Hwan;Jeon, Cheol-Kyun
    • Journal of Ocean Engineering and Technology
    • /
    • v.13 no.3B
    • /
    • pp.29-37
    • /
    • 1999
  • Ventilation of the marine engine room is very important for the health of the workers as well as the normal operation of machines. To find proper ventilation conditions of this engine room, numerical simulation with standard k-${\epsilon}$ model was carried out. In the present study, the marine engine room is separated to two floors with porus horizontal partition and considered as a closed space with a heat source and forced ventilation ducts. The porosity of horizontal partition is found to be important. For the engine room with 2 supply ports & 2 exhaust ports, the increasing of the porosity of horizontal partition is effective to reduce the recirculation flow zone in the second floor. When the engine room is ventilated with three supply air ports & one exhaust port, the increasing of the porosity of horizontal partition is effective to reduce the recirculating flow zone in the exhaust air area, but there is a possibility of local extreme heating at the lower side of engine near bottom.

  • PDF

A Study on the amount of Co gas in the kitchen related to facility enviromental condition and fuel management (부엌공기 중에 함유되어 있는 가스량과 부엌 구조시설 연료관리와의 관계에 대한 연구)

  • 장명욱
    • Journal of the Korean Home Economics Association
    • /
    • v.8 no.1
    • /
    • pp.146-158
    • /
    • 1970
  • It is a matter of amazing to realize that contamination of air by fuel gas in recent daily life at home directly effects to health of Korean housewives. A study in finding the status and the amount of co gas in the kitchen was con-ductedrelating the size of kitchen, door of exit, ventilation window, constraction of built in-brick stove (Boo Tu Mack), fuel management, in order to extend beneficial and improved management of housing. From the result of study, it was pointed out that constractional improvement of built-in-brick stove, heating floor (Ondol), timny, and ventilation window would been emergently needed. Demonstration studies were obtained in finding differences of the amount of co gas respectively in cooking time as 50-55ppm, and in not cooking time as 50-80p,p,m in the kitchen both, original and improved. Definite differences were found depend upon the condition with, without, or direction of the ventilation window. In addition to all above results, significant influence on gas pulling power of Ondol tunnel was shown. Many houses of Apartment house for have middle and low income groups been recognized so poor for health as indicated over 100ppm of co gas if window were not opened because of poor ventilation and weak gas pulling power of Ondol tunnel.

  • PDF

Analysis of impact factors affecting on the stack effect in high-rise building (고층빌딩 연돌 현상의 영향인자 분석)

  • Oh, Jin-Hwan;Song, Doo-Sam;Yoon, Sung-Min;Nam, Yujin
    • KIEAE Journal
    • /
    • v.16 no.3
    • /
    • pp.95-101
    • /
    • 2016
  • Purpose: Recently, high-rise buildings are popular in korea due to high rate of land usage and cost performance in urban area. However, high-rise building causes several problems such as safety issues, cooling/heating load, stack effect, disaster prevention etc. The stack effect is one of the representative problems. Even though there are many researches on stack effect, there are few studies on design guideline considering local condition. Method: This study focuses on the change of pressure distribution according to the design factors which affects the airflow in high-rise residential buildings by simulation analysis. In this study, city, building floor, stairwell door leakage area, elevator door leakage area and changes of layout were considered ad the design factor. Result: The simulation results indicate that building height and ambient air temperature are significant design factor for stack effect.

A Study on the Discourse for the Improvement of Living Conditions and Housing through Modern Women's Magazines (일제강점기 여성지에 나타난 생활개선 담론의 경향 고찰 - 주생활 및 부엌개량의 내용을 중심으로 -)

  • Kim, Young-Bum
    • Journal of the Korean housing association
    • /
    • v.22 no.4
    • /
    • pp.51-61
    • /
    • 2011
  • This study aimed to grasp trends of the discourse for improving living conditions carried out since 1920's, when the sense for mending the irrationality of conventional living emerged in various magazines. Among the movement, women intellectuals played an important roles to discuss reforming daily life and unhealthy, inconvenient houseworks. This study found the ideological background and direction of this discourse, and estimated its important role for housing improvement, analyzing the contents of articles published in representative womens' magazines of the modern times. In the discourse, they thought that it was most important to make houseworks brief and efficient, and concentrated on building rational environment for houseworks. As reforming kitchen system, heating system (Ondol) should be separated from cooking system to improve hygienic and economical condition of houseworks. Reformed kitchen would be equipped with new installations for effectiveness, lightened by sunlight through windows, and finished floor with cement and drainage for sanitation. Also, they suggested new ways of living, planning modern houses with reformed kitchen system, thinking about moving path and distance of housewives. This discourse would be a foundation to the change of kitchen system up to now.

Actual conditions on the Living Environment of Small-scale Group-homes for the Elderly (고령자용 소규모 그룹홈의 생활환경 실태)

  • Kim, Hyun-Jin;An, Ok-Hee
    • Journal of the Korean housing association
    • /
    • v.19 no.3
    • /
    • pp.21-29
    • /
    • 2008
  • To investigate the actual conditions on the living environment of group-homes for the elderly and their living environment, 4 group-homes were surveyed. As the results, conditions of location for the group-home of the elderly looked positive, on the other hand, safety for criminal prevention, accessability and convenient facilities were not on level satisfied. The average area of each space in the group-home indicated that the bed room was $11.21\;m^2$, the living room $28.13\;m^2$, the kitchen $23.59\;m^2$, and the bath room had an integrated type of bath room and toilet $7.63\;m^2$. The physical environments of each space in the group-home were investigated, In bed room, door, windows and illumination were relatively good but safety was extremely inferior. Living room mostly looked good except the doorsill which needs refurbishment. In kitchen, cooking table, windows, illumination, ventilator were somewhat satisfactory but gas-warning device should have been installed. In addition, in bath room and toilet, location, door, window, illumination and finished material were satisfactory. But the stepped difference between the bath room and other space, safety-bar, emergency bell and floor heating system were seriously deteriorated and must be improved for the safety of the elderly. Conclusively, living environment of group-home for the elderly is mainly satisfactory but it was necessary to take a consideration for their safety.

A Study on the Eco-Tecnique of EcoCenter - Focused on the Building Material and Solar System - (에코센터의 생태건축기술에 관한 연구 - 건축재료와 태양에너지활용시스템을 중심으로 -)

  • Choi, Young-Ho;Shim, Woo-Gab
    • KIEAE Journal
    • /
    • v.4 no.2
    • /
    • pp.65-72
    • /
    • 2004
  • Ecological architecture enables people to recycle and reuse architectural resources within the category of ecosystem and also to minimize the effect on environment in a whole process, including architectural planning, usage and exhaustion to use sustainable energies. Rammed earth wall construction method utilized in EcoCenter located in Crystalwaters ecological village in Austrailia is a good example, which maximizes its advantages and also covers its limits to use soil and wood as structural resources. In a case of wood, they used non-treated timber to minimize environmental load and utilized used materials in openings. In the roofs, aluminum coated steel which is plated with zinc collects rain effectively even though it is not regenerable. Nontoxic finishes and insulation in floor and ceiling with used papers are able to minimize its environmental load. Solar energy system applied in EcoCenter enables them to market extra energy with electricity companies as well as support needs of its own buildings to utilize photovoltaic panel system with PV panels. Passive solar system is planned effectively in heating and cooling to apply regenerative walls in a use of rammed earth wall construction and natural ventilation systems through openings.

Suggestion of the Characteristics of Element Technology and the Standard Model through the Comparison of Domestic Zero-energy Houses (국내 에너지제로하우스 비교를 통한 요소기술 특성 및 표준 모델 제시에 관한 연구)

  • Lee, Chung-Kook;Lee, Jeong-Cheol;Kim, Sang-Su;Suh, Seung-Jik
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.8 no.2
    • /
    • pp.27-35
    • /
    • 2012
  • Five zero energy house models developed in Korea for the purpose of the energy performance were compared and analyzed in the study. The standard passive house model applying common technology and efficient energy performance elements was proposed. Standard passive house 5 models have been developed commonly aiming at 100% energy saving, applying high-performance and high-efficiency exterior thermal insulation, using 3 low-e coated window system, and targeting average 0.65 ACH to enhance privacy. Energy recovery ventilators and dry and cold radiant heating floor has been partially applied. Eco-design techniques such as the awning device, heat insulating door, using natural light have been used. Solar and geothermal systems as the application of renewable energy technologies have been commonly applied. And fuel cells were applied to a partial model. The standard model based on common technical elements and average performance of each element and obtained from five model analysis has been proposed in the study.

An Investigation on Determinants of Apartment Price in Ilsan Area (일산지역의 공동주택 평당매매 가격결정 특성에 관한 연구)

  • Jang, Han-Sub;Yoo, Seon-Jong
    • Journal of the Korean housing association
    • /
    • v.18 no.6
    • /
    • pp.35-44
    • /
    • 2007
  • The purpose of this paper is to find out the factors affecting the apartment price given three sets of variables such as characteristics of apartment building, apartment site, and location. Data of 1,579 housing units in 224 apartment complex sites in Ilsan city were selected from the housing information of four public and private housing sources in 2006. The first set of variables for physical features include housing size (pyoung), preferring-floor, building orientation, heating system and structure of entrance. The second set of variables for building were number of housing units, built year and rank of construction company. The third set of variables for location were distance from number of school, the subway station, distance of department store and park. For the analysis, the hedonic price model, which was one of the methods to estimate social convenience, was used along with the SPSS statistical program and regression analysis. The results are as follows, Firstly, in the structural characteristic variables, it was analyzed that all of the variables except facing affected the apartment price. Secondly, In the site characteristic variables, unusually all of the variables were not affected the apartment price in Ilsan city. Finally, the locational characteristic variables number of school, the subway station, distance of department store and park affected the apartment price. In case of Ilsan city, educational facilities was likely to positively contribute to the price of apartment.

An Experimental Study of Precast concrete Alters Cement Types of High-Strength Concrete (시멘트종류를 변화시킨 프리캐스트 고강도 콘크리트의 실험적 연구 - 수화열 온도특성을 중심으로 -)

  • Park, Heung-Lee;Kim, Sung-Jin;Paik, Min-Su;Lee, Seung-Hoon;Park, Byung-Keun;Jung, Sang-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.05b
    • /
    • pp.119-122
    • /
    • 2009
  • As architectures have recently become high-risers and mega-structured, stable high strength products have been ensured. Accordingly, use of precast concrete accouplement has been increased in order to facilitate air compression and rationalize construction. Since not only external heating but a1so internal temperature rise caused by the accumulation of cement hydration heat in manufacturing process, precast concrete members with large cross-section used for high-rise mega-structure's columns and beams may exhibit different temperature history compared to the precast concrete members for wall and sub-floor with relatively small cross-sections. Therefore, this study aims to elucidate the characteristics of temperature history of mass concrete members cast with high-strength concrete fur precast concrete application. In this study, large cross-sectional precast concrete mock-up, unit cement quantity, and temperature histories in manufacturing precast concrete member under different curing condition were inclusively investigated.

  • PDF