• Title/Summary/Keyword: Floor heating

Search Result 397, Processing Time 0.026 seconds

Impact of Reinforced Standard for Envelope Insulation on the Regional Heating and Cooling Energy Consumption (강화된 건물 외피 단열기준의 지역별 냉난방에너지 감소 효과)

  • Moon, Jin-Woo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.10
    • /
    • pp.646-655
    • /
    • 2011
  • This study aimed at quantifying the impact of the reinforced standard for envelope insulation on heating and cooling energy consumption in a Korean detached house as well as at identifying the effect of regionally subdivided standards. For them, a series of simulations for application of the reinforced standard on respective walls, roof, floor, windows, and all envelopes were computationally conducted for a prototypical detached residential building. In addition, the subdivided standards were applied to each regions-central and southern regions, and the Jeju island. Analysis revealed that heat transfer through envelopes was the most significant source of building heat gain and loss; the reinforced standard effectively reduced heating energy consumptions, especially in central region; and the subdivided standards did not presented a clear difference in the amount of energy consumption for the southern region and the Jeju island, thus, a further study is required to investigate the necessity of regional subdivisions.

A Study on the Establishment of the Optimal Temperature Limits for Man's Thermal Comfort in an Asymmetric Radiant Space (불균등 복사공간의 쾌적온도범위 설정에 관한 연구)

  • Sohn, Jang-Yeul;Kong, Sung-Hoon;Yun, Yong-Jin
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.14 no.3
    • /
    • pp.187-199
    • /
    • 1985
  • The low-temperatured radiant heating System like a panel heating system is recognized as nice means to make comfortable indoor environment. Perhaps, 'Ondol' would be a typical example of the Panel heating system. Nevertheless. Occupants in a radiantly heated Space which has an asymmetric radiant field may feel thermally discomfort due to the asymmetric radiation. The aim of this Study is to suggest the fundamental technical data for establishing Standards of thermally comfortable environment when designing a radiant heating System. Thermal distribution of indoor environment and the skin temperature of the occupants were measured at experimental room in KIER (Korea Institute of Energy and Resources). Whole/Regional thermal and comfort Sensation votes of the occupants were taken simultaneously in order to investigate the relationships between thermal environmental factor and the occupants' responses. The effect of an asymmetric radiation on thermal environment and the occupants' responses was analyzed by using a v.r.t.(vector radiant temperature). By this means, the thermally neutral limits for the ambient air temperature and the floor surface temperature by the occupants' responses were Obtained. And the recommended temperature limits of the indoor surface were derived from the experimental work and the theory of radiant and will provide thermal neutrality for man without any discomfort on the part of the body.

  • PDF

A Historical Study on the Achitectural Cooking and Storing Spaces in Traditional Korean Houses (한국(韓國)의 전통적(傳統的) 식생활공간(食生活空間))

  • Joo, Nam-Chull
    • Journal of the Korean Society of Food Culture
    • /
    • v.2 no.2
    • /
    • pp.169-179
    • /
    • 1987
  • In the life style of the neolithic age, cooking and sleeping space was in one room dugout without differentiation of spaces, so to say one room system. Ro(a kind of primitive fire place) was used for both cooking and heating. However, in the early part of the Iron Age, the uses of Ro were separated into two major uses of cooking and heating. Especially, L-shaped Kudle(an unique under floor heating structure of Korea) was invented for the new system of heating, extending to Koguryo Period. The life style of Koguryo Dynasty could be seen through the mural paintings of tombs. For these mural paintings contain of cooking space(Kitchen), meat storage, and mill house drawing, we can recognize that houses were specialized many quaters according to their function. Also a kitchen fuel hole for preparing food was built without relation to L-shaped Kudle. But during Koryo Period, Kudle could be set up all over the room, the so-called Ondol(the unique Korean panel heating system) settled down. From this development of heating system, room could be adjacent to kitchen, and kitchen fuel hole and heating fuel hole be onething. This system was developed with variety, extending to Chosun Dynasty. In the period of Chosun Dynasty, a kitchen was made close to an Anbang(Woman's living room), and Anbangs Ondol was heated by the warmth of a cooking fireplace. Therefore Handae Puok, outer kitchen was used in summer. As for its storage space, it was seen that there were a pantry near the kitchen and a store house constructed as an independant building. In the latter, it was devided into a firewood storage, a Kimchi storage, and a rice storage, etc. Especially it is a unique feature that 'Handae-Duyju', an outer rice chest which keeps rice, was constructed as an isolated small building.

  • PDF

A Study on the Proper Quantity of Ventilation through Changing Floor Temperature in Sleeping (수면시 바닥표면온도에 따른 적정 환기량에 관한 연구)

  • Kim, Dong-Gyu;Lee, Sung;Kim, Se-Hwan
    • KIEAE Journal
    • /
    • v.10 no.1
    • /
    • pp.19-24
    • /
    • 2010
  • Modern people are spending most of time in interior area. Indoor air environmental problem is one of the most effective factors influenceable to human health. Furthermore, saving energy and making ventilation system for pleasant indoor environment are necessary when it is faced shortage of energy over the world. In our country's case, it is already imposed that required quantity of air ventilation in buildings is 0.7 times per hour on "The regulation on building engineering system". As on the rise of the interests about Indoor air environment, Heat and Carbon dioxide emissions from User's metabolism, activity, furniture, and construction materials etc. could be the causes of Indoor air pollution. If these materials stays in Indoor air for so long, it could directly influence the user's health condition with a disease. As of building's sterilization improved that raised more mechanical ventilation. It also leads much energy waste in a period of high price of fossil fuel. Therefore, the way that saves energy and effective control of indoor ventilation is urgently needed. So, this study places the purpose on validating volume of indoor ventilation and user's comfortable degree by comparison CO2 emission rate through changing floor temperature.

Improvement and Standardization of Rural Korean Kitchen Space: Field Survey on Architectural Elements and Facilities(1) (농촌부엌의 개선 및 표준화에 관한 연구(I) -부엌의 물리적 측면을 중심으로-)

  • Chi, Soon;Yoon, Bocha;Yoon, Chung-Sook;Yoo, Young-Hee;Choi, Byoung-Sook
    • Journal of the Korean Home Economics Association
    • /
    • v.29 no.1
    • /
    • pp.71-96
    • /
    • 1991
  • The purpose of this study was to identify kitchen space needs in regard to the architectural elements and facilities of rural houses. Three rural villages, Kum-Sung Ri, Young-San 1 Ri, and Yu-Bang 2.5 Ri were selected for this study. The present and past condition of the kitchen space was investigated by the field survey method. The major findings were that: 1) The interior floor materials of the kitchen had been changed from mostly mudplastered floor to linoleum, and the former low level of the kitchen floor had been lifted to the same level of the house plane. This change was made possible by the separation of the cooking from the heating system. 2) Western style kitchen, work centers and kitchen cabinets had been installed in the most of the rural houses. 3) On the basis of this study, the rural Korean kitchen space was classified into six types.

  • PDF

A Study on the Loft in Korean Traditional Houses - Focused on the Chun-Buk Province - (전통주택의 다락에 관한 연구 - 전북지방을 중심으로 -)

  • 최인호
    • Journal of the Korean housing association
    • /
    • v.8 no.2
    • /
    • pp.1-15
    • /
    • 1997
  • This study is purpose to analyze and adjust structure and composition methodology for Loft of korean traditional houses and than studying correlation about housing plan, according to middle-story structure like Loft form housing architecture. The Loft is composited to level by condition of location, using a rise of stair by expanding of span by function. We can divide to condition of location flatland and slant. In the flatland case, Loft is so heating that the kitchen floor make a lowly and in the slant case, Loft is composited a part of wing using height attitude of floor when the house build type and ㅁ type. Through this study. the Loft is various form of this structural forming then is affect the house facade. The composite of wall is come with the existence of Loft and the wall divided by the lintel and wall line.

  • PDF

Ecological Characteristics of Usonian Houses of Frank Lloyd Wright (프랭크 로이드 라이트의 유소니언 주택의 생태적 특성)

  • Yoon, Jiyoung
    • KIEAE Journal
    • /
    • v.10 no.3
    • /
    • pp.17-26
    • /
    • 2010
  • This study aims at exploring the characteristics of the Usonian houses of Frank Lloyd Wright from an ecological viewpoint. After considering the definition and application of ecological architecture through literature review, 28 Usonian houses were selected and analyzed for the study. Also, nine Usonian houses, which clearly have ecological and historical importance, were visited and more thoroughly analyzed. The result shows that Usonian houses are ecological in terms of 1) the relationship among nature, landscape and house, 2) the orientation, natural light and natural ventilation, 3) the use of natural local materials including wood, stones and bricks, 4) the use of floor heating (the On-dol system inKorea), 5) the human scale, 6) the use of the board and batten unit (an early system of prefabrication), and 7) the openness and flexibility of floor plans.

A Study on the Dry-Shrinkage Properties For Floor Mortar With Crack-Reducing (균열저감형 바닥마감전용 모르터의 건조수축특성 연구)

  • 이종렬;이웅종;채재홍;박경상;김기수
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.175-180
    • /
    • 1999
  • The heating system of korea apartment house is called Ondol. The surface finishing mortar of this floor system typically used the cement based mortar, where the surface finishing mortar easily appears the crack. To order to crack control, the cement that added expansive additive used to reducing dry-shrinkage. For the surface finishing mortar, the types of shrinkage is known as plastic shrinkage, dry-shrinkage and autogenous This experimental study is to investigate the difference on dry-shrinkage of the cement that added expansive additives and OPC. The test method is varied the ration of water/cement (W/C) and the ratio of sand/cement(S/C). For OPC, The increase of the ratio of S/C is reduced dry-shirnkage but for the cement that added expansive additives, the increase of the ratio of S/C is augmented dry-shrinkage For OPC, The increase of the ratio of W/C is augmented dry-shrinkage but for the cement that added expensive, the increased of the ratio of W/C is reduced dry-shrinkage.

  • PDF

A Study on the Quality Properties of the Expansive For Dry-Shrinkage Compensation of the Floor Mortar (온돌바닥 모르터의 건조수축보상을 위한 팽창제의 품질특성 연구)

  • 이웅종;이종열;정연식;이순기;정성철
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10a
    • /
    • pp.155-160
    • /
    • 2000
  • In this paper, we investigated quality properties for the expansive of the CaO-$CaSO_4$ family which used to compensate dry-shrinkage in the floor mortar of On-Dol heating System. This experimental study established the mix condition with quantity of the expansive and is to investigate the relativity between the compress strength and the length change and the relativity between the chemical properties and the length change with the analysis of the physical and chemical properties. As a result of the study, the expansive is controlled by more the CaO than the $CaSO_4$. The relativity between the compress strength and the length change is expressed by exponential function, showing that if the expansive performance is increased, the compress strength is decreased. And the relativity between the chemical properties and the length change is only relative the quantity of the F-CaO among the chemical properties, is expressed by the second order function, showing that if the F-CaO is increased, the expansive performance is increased.

  • PDF

A Study on the Control of Water Flow and Water Temperature in the Radiant Cooling System through Simulations (시뮬레이션을 통한 바닥복사냉방 시스템의 공급유량 및 냉수온도 제어에 관한 연구)

  • 김용이;윤혜림;여명석
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.6
    • /
    • pp.532-540
    • /
    • 2001
  • The objectives of this study are to analyze the control variables according to condensation occurrence, to find the range in floor surface temperature and frequency of condensation, and to evaluate the control methods through simulations when the radiant heating system is used for cooling. Through the simulation analysis the control methods such as on/off control, variable flow control and outdoor reset with indoor temperature feedback control are evaluated and compared. The results show that the lowest floor surface temperature is around $23^{\circ}C$, the surface condensation can be prevented by controlling indoor humidity within 20g/kg(DA0, and that outdoor reset with indoor temperature feedback control is more appropriate than on/off control and variable flow control with regard to prevention of the condensation and thermal comfort.

  • PDF