• Title/Summary/Keyword: Floor density

Search Result 199, Processing Time 0.027 seconds

HEATING FLOOR FOR POULTRY : THEORETICAL AMD TECHNOLOGICAL INVESTIGATIONS

  • Narushin, Valery G.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1996.06c
    • /
    • pp.1090-1100
    • /
    • 1996
  • Heating floor is the most profitable system of air heating at poultry houses. THe tubes with heating elements inside are laid into the layer of concrete. To prevent lossese of heat penetration deep into the ground the layer of isolation material is laid below the tubes . The depth of isolation laying in every point of the heating floor may be calculated according to the author's formula using the data of temperature on the floor surface and the tube, the distance between tow nearest tubes, and the distance between the tube and the floor surface. Technological investigations allow to estimate the optimal density for greese and ducks when they are bred on the heatuing floor.

  • PDF

A Study on the Change of Architecture Density and Residential Environment according to Reconstruction (재건축에 따른 건축밀도 및 주거환경의 변화 연구)

  • Kim, Hong-Bae
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.19 no.1
    • /
    • pp.35-42
    • /
    • 2017
  • This study aims to investigate the change in building density and residential environment after the reconstruction of decrepit public rental housing complexes formed in accordance with the Land Readjustment Project during the 1970s-80s. The results of this study can be summarized as follows: First, in terms of change in residential environment after the reconstruction, floor plans that were limited to two to four types and to small apartments measuring $42.9m^2$(13py)-$56.1m^2$ (17py) became varied, presenting 5-6 types of floor plans and various sizes of apartments. In particular, the reconstructed apartments were mainly built in a size smaller than 85($m^2$) and in the 3LDK floor plan and staircase-style unit architectural structure in order to reflect the lifestyle of residents. Second, in terms of change in building density after the reconstruction, the building coverage ratio did not change a lot, but the floor area ratio showed great change depending on the complex, ranging from a minimum of 2.9 times (Singdong Complex) to a maximum of 5.4 times (Eoyangdong Complex). Such change is attributable to the reconstruction policy that aims to improve the residential environment for original residents, secure economic feasibility and efficiency, and reflect the lifestyle of residents while incorporating dividends assigned to the existing housing project members as well as the maximum floor area ratio allowed by the regulation. Additionally, in terms of change in the number of floors and building density after the reconstruction, the former 5-story apartments were changed to apartments with 16-28 stories. Accordingly, the number of households in each complex has also increased by 20%. Third, according to the characteristics of parking facilities in terms of the size and density of parking spaces, former apartment complexes had only aboveground parking lots, not underground parking area. The newly constructed apartment complexes have underground parking space, and the parking-housing ratio is 1.1-1.3 cars.

Economic Feasibility Study for Providing Co-generation System in various Type of Apartment Complexes (아파트단지의 특성에 따른 열병합발전도입의 경제성 비교연구)

  • Gi, Woo-Bong;Kim, Gwang-Ho;Lim, Hee-Jin;Yoon, Kyung-Shick;Jang, Hyuk-Bong;Kim, Dong-Hwan
    • New & Renewable Energy
    • /
    • v.3 no.1 s.9
    • /
    • pp.27-37
    • /
    • 2007
  • This study is to analyse the feasibility for providing Co-generation plant in Apartment Complex for 4 typical Apartment Complexes located Seoul metropolitan area, The selected complexes are three midium-large size Apartment[nearby 35pyoug of floor area] and one complex of small size Apartment[below 25 pyoung of floor area] for comparison. The necessary data for the study were collected with visitation of each site. The study showed very positive result for the three medium-large size Apartment Complexes of which the average floor area is more than 25 pyoungs, while negative result for the Complex of which average floor area is less than 25 pyoungs. Other than floor size it was found that the electric consumption density also influence the economic feasibility. In study the unit fixed cost of the energy produced from Co-generation plant is one third of the unit variable cost[fuel cost] and it seems better to select high thermal efficiency machine for Co-generation plant even with some higher cost of the plant.

  • PDF

Urban Tissue, Zoning and Achieved Floor Area Ratio (A-FAR) - Focused on Developed Floor Area Ratio (D-FAR) Compared to the Legal Floor Area Ratio (L-FAR) in Residential Area and Commercial Area in Seoul - (용적실현비(A-FAR)에 영향을 미치는 용도지역별 대지특성에 대한 분석 - 서울시 주거지역 및 상업지역에서 법정용적률(L-FAR) 대비 실현된 용적률(D-FAR)을 중심으로 -)

  • Kim, Soo Hyun;Choi, Chang Gyu
    • Journal of Korea Planning Association
    • /
    • v.54 no.2
    • /
    • pp.33-45
    • /
    • 2019
  • The Legal Floor Area Ratio (L-FAR) has been used as a major urban planning tool for efficient management of land use, landscape, and density. The Developed Floor Area Ratio (D-FAR) in each parcel is realized by such physical and institutional factors as urban tissue, local characteristics, and zoning with the L-FAR. The Achieved Floor Area Ratio (A-FAR), the ratio of the D-FAR to the L-FAR, is the relationship between realized density and the intended/desired outcomes of the regulations. The A-FAR informs the efficiency of L-FAR and its effect on parcels, and is an indicator of the demands of real estate developments under the zoning regulation. This study used detailed data of each parcel's characteristics, including parcel size, road width, and the number of roads bordered by a parcel, to identify the influencing factors on A-FAR. This analysis confirmed that the parcel size has a non-linear negative effect in the residential zone but a linear positive effect on A-FAR in the commercial zone. The width of the parcel's frontage in the commercial zone has a positive effect on the value, while in the residential zone the narrower width has higher A-FAR. In Seoul, the residential zone has higher A-FAR than the commercial zone, which means that the former has a relatively higher development pressure but a lower designated L-FAR. This result reflects that Seoul's residential zone absorbs the demand of commercial uses because of the significant permitting of mixed land use and has high-density residential buildings.

Analysis of Influence Factors on Dynamic Properties of Floor Impact Noise Insulation Materials (바닥충격음 완충재의 동적특성에 영향을 미치는 요인 분석)

  • Kim, Heung-Sik;Joo, Si-Woong;Kim, Dae-Jun;Kim, Byeung-Jin
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.946-949
    • /
    • 2005
  • In this paper, influence factors on dynamic properties of floor impact noise insulation materials are suggested. For this purpose measurements on the dynamic stiffness and the loss factor of resilient materials are carried out by Korea standard (KS F 2868) according to the change of density, thickness, design pattern, and composition of materials. As a result the values of dynamic stiffness was decreased at high density and thick thickness, and that of loss factor was increased at low density. For dynamic properties, the pattern of lattice and waffle type material is better than that of plat type, and the mixed composition of materials is better than the composition of double layer materials at same thickness.

  • PDF

A Study on the Reduction of Noise and Vibration in Ship Cabins by Using floating Floor (뜬바닥구조를 이용한 선박 격실의 소음.진동 저감에 관한 연구)

  • Kim, Hyun-Sil;Kim, Jae-Seung;Kang, Hyun-Ju;Kim, Bong-Ki;Kim, Sang-Ryul
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.9 s.114
    • /
    • pp.949-957
    • /
    • 2006
  • In this Paper, reduction of noise and vibration in ship cabins by using floating floor is studied. Two theoretical models are presented and predicted insertion losses of floating floor are compared to experimental results, where measurements have been done in mock-up built for simulating typical ship cabin structures. In ships, mineral wool is usually used as the impact absorbing materials. The first model (M-S-Plate Model) is that upper plate and mineral wool are assumed as a one-dimensional mass-spring system, which is in turn attached to the simply supported elastic floor. The second model (Wave-Plate Model) is that mineral wool is assumed as an elastic medium for wave propagation. The comparisons show that M-S-Plate model is in good agreement with experimental results when density of mineral wool is 140K, and fiber direction is horizontal. For higher density and vertical fiber direction, Wave-Plate model shows good agreements with measurements. It is found that including the elastic behavior of the floor is essential in improving accuracy of the prediction for low frequency ranges below $100{sim}200Hz$.

Development of Traffic Accident Forecasting Models Considering Urban-Transportation System Characteristics (토지이용 및 교통특성을 반영한 교통사고 예측모형 개발 연구)

  • Park, Jun-Tae;Jang, Il-Jun;Son, Ui-Yeong;Lee, Su-Beom
    • Journal of Korean Society of Transportation
    • /
    • v.29 no.6
    • /
    • pp.39-56
    • /
    • 2011
  • This study proposed a traffic accident prediction model developed based on administrative districts of Seoul. The model was to find the relationship between accident rates and the representative land usage of the districts (development density) - the higher the development density (building floor area) is, the higher the traffic accident rate is. The findings showed that traffic accident statistics differ from (1) residential building floor area, (2) commercial building floor area and (3) business building floor area.

Effect of Different Housing System on the Performance, Bone Mineral Density and Yolk Fatty Acid Composition in Laying Hen

  • Hassan, Md. Rakibul;Sultana, Shabiha;Choe, Ho Sung;Ryu, Kyeong Seon
    • Korean Journal of Poultry Science
    • /
    • v.39 no.4
    • /
    • pp.261-267
    • /
    • 2012
  • Different housing systems have considerable influence on performance in poultry production. Therefore, the present study was undertaken to investigate the impact of different housing systems on the performance, bone mineral density and egg yolk fatty acid composition in laying hen. Hy-line brown pullets (n=450) of 12 weeks age were randomly divided into 3 housing systems with 6 replicates of 25 birds in each room. A diet with 2,750 kcal/kg ME and 16.5% CP was assigned to all birds. The pullets provided free access to feed and water. Significantly (P<0.05) higher values for egg production, egg mass and feed conversion efficiency were found in battery cages, however egg weight, egg shell color and breaking strength was remarkably (P<0.05) higher in floor system. The albumin height and Haugh unit were significantly higher (P<0.05) in battery cages which was statistically similar to aviary housing system. The egg yolk fatty acids concentration of linoleic acid and linolenic acids were significantly higher in aviary and in floor system, respectively, however both values were lower in battery cages. Saturated and unsaturated fatty acid content (%) in egg yolk did not influence by any housing systems. Bone mineral density was significantly higher (P<0.05) in floor and aviary housing system than that of battery cage system. It was concluded that in battery cages the egg production and composition maximized, however higher bone mineral density and yolk fatty acids content can be improved in the laying hen reared on floor and aviary housing systems.

A Study on the Relationship Analysis Model between Visibility and Evacuation Time by User's Movement in the Lower Floor of General Hospital (종합병원 저층부에서의 이용자 이동에 따른 가시성과 피난 시간의 상관관계 분석 모델에 관한 연구)

  • Jung, Gi Hyun;Kweon, Jihoon
    • Journal of the Regional Association of Architectural Institute of Korea
    • /
    • v.21 no.3
    • /
    • pp.11-21
    • /
    • 2019
  • The purpose of this study was to present an analysis model for finding the correlation between visibility and evacuation time as users move in the outpatient department of the general hospital. The spatial scope of the study was limited to the first floor and second floor which are used for the outpatient department. Traffic density in outpatient departments was surveyed on site. Based on the surveyed traffic density, the evacuation simulation model was established for calculating the escape route and evacuation time for an individual user. The traffic density of the outpatient department as per the evacuation time was also calculated. With using evacuation simulations, the flow of evacuees was calculated through the density of traffic over the time of evacuation. Visibility data were set in the simulation model for users' escape routes. A correlation analysis between the product of evacuation flow measure and visibility measure of the evacuation population and evacuation time was performed. The analysis result showed negative correlation within a specific distance range. This study presented an analysis model showing that the evacuation condition considering spatial visibility in the outpatient department of general hospital visibility was negatively related to the analyzed evacuation time at the design stage.

Effects of Housing Systems on Physiological and Immunological Parameters in Laying Hens

  • Kang, Sung-Young;Ko, Young-Hyun;Moon, Yang-Soo;Sohn, Sea-Hwan;Jang, In-Surk
    • Journal of Animal Science and Technology
    • /
    • v.55 no.2
    • /
    • pp.131-139
    • /
    • 2013
  • The aim of this study was to assess the effects of housing systems on physiological and immunological responses as stress indicators in laying hens. A total of 500 White Leghorn aged 16 weeks were allotted into ten conventional cages (10 birds/cage and 810 $cm^2$/bird) and four floor pens (100 birds/pen and 2,800 $cm^2$/bird) for 24 weeks. The hens housed in conventional cages with higher stocking density resulted in a significantly (P<0.05) lower BW compared with those housed in floor pens with lower stocking density without affecting the relative weights of immune organs between housing conditions. In plasma biochemical values, cholesterol and corticosterone were significantly (P<0.05) lower in the hens housed in floor pens compared with those housed in conventional cages. In pro-inflammatory cytokines, hepatic interleukin (IL)-10 and interferon-gamma (IFN-${\gamma}$) levels were significantly (P<0.05) higher in the hens housed in conventional cages compared with those kept in floor pens. Splenic and thymic IFN-${\gamma}$ expression was significantly (P<0.05) up-regulated in the hens kept in conventional cages compared with those kept in floor pens without affecting IL-1, IL-10, lipopolysaccharide- induced tumor necrosis factor-${\alpha}$ factor (LITAF) and inducible nitric oxide synthase (iNOS). In the bursa of Fabricius, IL-10 and iNOS expression of the hens housed in conventional cages were significantly (P<0.05) higher compared with those of the hens housed in floor pens. In conclusion, layers housed in conventional cages enhanced plasma cholesterol, corticosterone and some pro-inflammatory cytokines in the immune organs compared with those in floor pens.