Development of Eco-friendly Woven Floor Mat with High Resilience II - Characterization of TPU Coating Yarn and Floor Mat - (고탄성 특성을 보유한 친환경 우븐 바닥재에 관한 연구(II) - TPU 코팅사 및 바닥재의 특성-)

  • Lee, Sun-Hee
    • Fashion & Textile Research Journal
    • /
    • v.14 no.4
    • /
    • pp.635-640
    • /
    • 2012
  • In this study, thermoplastic urethane (TPU) coating yarns were prepared at various extruding temperatures. The fine structure and mechanical properties of resultant TPU coating yarns examined by the wide angle X-ray diffractometer (WAXD), differential scanning calorimetry (DSC), dynamic mechanical thermal analysis (DMTA), and tensile test. TPU coating yarns (prepared at extruding temperatures at $175^{\circ}C$) were confirmed as a stable fine structure that obtained excellent tensile strength and flexibility. The C samples prepared by optimized conditions made by TPU woven floor mat. The structure of the woven mat is $4{\times}4$ basket weave and have laminated with the EVA foam to obtained final TPU woven floor mat products. The resultant TPU woven floor mat was obtained to 1.5MN of tensile strength, 22% of the elongation, and 0.2MN of tear strength. The weight loss abrasion and the resilience by the ball rebound of the TPU-woven floor mat was prior to those of the PVC subsequently, we were able to develop a woven floor mat with TPU coating yarn and produce an eco-friendly high valuable woven floor mat using an interior product.

Finite element study on composite slab-beam systems under various fire exposures

  • Cirpici, Burak K.;Orhan, Suleyman N.;Kotan, Turkay
    • Steel and Composite Structures
    • /
    • v.37 no.5
    • /
    • pp.589-603
    • /
    • 2020
  • This paper presents an investigation of the thermal performance of composite floor slabs with profiled steel decking exposed to fire effects from floor. A detailed finite-element model has been developed by representing the concrete slab with steel decking under of it and steel beam both steel parts protected by intumescent coating. Although this type of floor systems offers a better fire resistance, passive fire protection materials should be applied when a higher fire resistance is desired. Moreover, fire exposed side is so crucial for composite slab systems as the total fire behaviour of the floor system changes dramatically. When the fire attack from steel parts, the temperature rises rapidly resulting in a sudden decrease on the strength of the beam and decking. Herein this paper, the fire attack side is assumed from the face of the concrete floor (top of the concrete assembly). Therefore, the heat is transferred through concrete to the steel decking and reaching finally to the steel beam both protected by intumescent coating. In this work, the numerical model has been established to predict the heat transfer performance including material properties such as thermal conductivity, specific heat and dry film thickness of intumescent coating. The developed numerical model has been divided into different layers to understand the sensitivity of steel temperature to the number of layers of intumescent coating. Results show that the protected composite floors offer a higher fire resistance as the temperature of the steel section remains below 60℃ even after 60-minute Standard (ISO) fire and Fast fire exposure. Obtaining lower temperatures in steel due to the great fire performance of the concrete itself results in lesser reductions of strength and stiffness hence, lesser deflections.

INFLUENCE OF ROLLING LOADS BY CASTERS ON SEPARATION RESISTANCE OF SUBSTRATE CONCRETE AND SYNTHETIC RESIN FLOOR COATINGS (下地コンクリ-トと合成樹脂塗り床材の耐剝離性に及ぼす キャスタ一の走行荷重の影響)

  • Takamasa, Mikami;Choi, Soo-Kyung
    • Journal of the Korea Institute of Building Construction
    • /
    • v.3 no.4
    • /
    • pp.73-78
    • /
    • 2003
  • In this Study, we examined the influence of characteristics of rolling loads by casters on separation resistance of substrate concrete and synthetic resin floor coating. In the experiment, we first prepared floor samples having substrate concrete of various compressive strength, surface hardness and surface configurations, then put the coated samples to the test of separation resistance with Rolling Caster Loading Machine. Three loading conditions consisted of different kinds of casters, rolling conditions, and coating materials. Consequently, we clarified that the grade of separation resistance varied widely according to the characteristics of substrate concrete and rolling loads.

A Study on the Emission of VOCs in Parking Lot Floor Coating (주차장 바닥 코팅제의 휘발성유기화합물 배출에 관한 연구)

  • Lee, Seung-Chan;Yoon, Gil-Ho;Park, Yong-Soon;Kil, Bae-Su;Yoon, Hyun-Do
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.4
    • /
    • pp.152-158
    • /
    • 2019
  • Measure the type and content of VOCs for A-company epoxy coating and B-company floor coating(Type A, B), which are used as flooring materials for parking lots. Than the VOCs used gas detectors to measure gas emissions, assuming the worst environment to reduce errors in external environments in the formaldehyde, toluene and xylene harmful to workers and tenants. As a result, A-company epoxy coating has the largest amount of VOCs, and compared to A-company epoxy coating, B-company floor coating of A type represented about 79% less and B type about 96% less. In addition, A-company epoxy coating was also the highest in gas emission measurement for formaldehyde, toluene and xylene using gas detector after 1 hour and 8 hours in closed environment conditions. B-company floor coating A type was less than A-company epoxy coating, which was about 42.3% less measured. And type B satisfied all TWA even in closed environment conditions.

Synthesis and Charcterization of UV-curable Polyurethane Acrylates Coating Composition for PVC Tiles (PVC 바닥상재용 광경화형 폴리우레탄 아크릴 수지의 합성 및 특성고찰)

  • Zhao, Hong;Ha, Jin-Wook
    • Proceedings of the KAIS Fall Conference
    • /
    • 2009.12a
    • /
    • pp.80-83
    • /
    • 2009
  • Application of UV curing technique for poly vinyl chloride (PVC) floor tiles coating has improved the quality of PVC floor. Various formulations including acrylated oligomers based on a polyurethane were blended with reactive monomers, photoinitiators and other additives. The used oligomers are commercial aliphatic urethane acrylates. Thin films were prepared on PVC tiles by bar coating with different formulations using UV radiation. The coating resins were characterized by FTIR. The properties of UV-cured films such as gloss grade and adhesion were examined. The properties of UV-cured films dependent on the influence of composition and processing conditions was studied. The investigation was conducted to achieve an optimal domain of composition and desired coating effect.

  • PDF

Synthesis and Characterization of UV-curable Polyurethane Acrylates Coating Resins for PVC Tiles (PVC 바닥상재용 광경화형 폴리우레탄 아크릴 수지의 합성 및 특성고찰)

  • Zhao, Hong;Ha, Jin-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.5
    • /
    • pp.1773-1777
    • /
    • 2010
  • The Application of UV curing technique for poly (vinyl chloride) (PVC) floor tiles coating has improved the quality of PVC floor. Several formulations were made including acrylated oligomers based on a polyurethane were blended with reactive monomers, photoinitiators and other additives. The used oligomers are commercial aliphatic urethane acrylates. Thin films were prepared on PVC tiles by bar coating with different formulations using UV radiation. The coating resins were characterized by FTIR. The properties of UV-cured films such as gloss and adhesion were examined. The properties of UV-cured films dependent on the influence of composition and processing conditions was studied.

A Study on Properties of PVA/$SiO_2$ Organic-inorganic Hybrid Materials Barrier Layer Coated on Flexible Substrate (PEN)

  • Koo, Tae-Wook;Farva, Umme;Yu, Eric S.H.;Kim, Yun-Su;Park, Chin-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.657-659
    • /
    • 2008
  • Barrier coating properties of PVA/$SiO_2$ on the flexible substrates (PEN) have been investigated. Thin layer of PVA/$SiO_2$ organic-inorganic hybrid materials were deposited on PEN substrate by the spin-coating. The optical properties and surface roughness of barrier layer on flexible substrate were characterized by AFM, UV-Vis and WVTR/ OTR.

  • PDF

Diagnosis of Coating Deviation in Continuous Galvanizing Line (연속용융아연 도금라인의 도금편차 진단)

  • 배용환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.26 no.2
    • /
    • pp.192-199
    • /
    • 2002
  • In continuous galvanizing process, the mass of zinc deposited and its distribution are controlled by the air pressure, effective distance from the air knife nozzle to the steel strip surface and line speed. Coating defects are resulted from the unbalance of these control factors and the inaccuracy of coating equipments. This paper investigates the main cause of coating deviation and a new air knife system for control of coating thickness was developed. We investigate dynamic pressure variation by air knife types. It is found that the coating deviation is caused by the unbalance of dynamic pressure, the irregularity of strip position, and the strip vibration. Formulating a useful coating model by using present working condition, an optimal working condition is suggested. The productivity and coating quality are improved by applying the result of this research at the shop floor.

Characteristics of Fancy Veneer Plywood Floor using Green Tea Leaves Powder (녹차잎분말을 사용한 마루판의 특성)

  • Kang, Seog-Goo;Lee, Hwa-Hyoung
    • Journal of the Korea Furniture Society
    • /
    • v.21 no.4
    • /
    • pp.284-292
    • /
    • 2010
  • This research was carried out to examine the properties of fancy cherry veneer overlaid on the PF resin bonded Meranti plywood floor, which 2.5% green tea leaf powder was applied in the UV varnishes and the adhesives for scavenging the volatile organic compounds. The results were as follows: 1. The various properties of the treated samples, such as density, moisture content, thickness swelling, bending strength(MOR), adhesion shear strength, surface abrasion, curling, cyclic delamination test with boiling water, boiling property, cold-resistance and heat resistance, acid resistance and alkali resistance, and anti-contamination property showed no significant difference between the properties of the control samples. 2.5% green tea leaf powder treated floor gave a little better results than the control for surface scratch test. 2. In case of QUV and weathering test, no difference between the treated sample and control was found. 3. The floor was discolored by adding 10% green tea leaf powder to UV coating, and the floor was also discolored to light green during by the soaking test. The color of floor was not changed up to 5% addition level.

  • PDF

Optimum of Parts Design in Large Floor Hinge (대형 플로어 힌지 부품의 최적화)

  • Lim, Hwoa-Seob;Chung, Han-Shik;Jeong, Hyo-Min;Huh, Sun-Chul
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.815-820
    • /
    • 2001
  • According as industry is complex, architecture is changing into the complex and diverse style and also customer's demands are becoming diversified. Among these, a door field is very important as much as saying nothing of more explanation. In this paper, in order to develop large floor hinge, mechanical properties of component parts are measured by vickers hardness tester, microstructure analysis and at the same time, these are designed by the FEM analysis.

  • PDF