BF인증을 위한 바닥 마감재 미끄럼 성능기준 및 측정방법에 대한 연구 (A Study on Floor Slip Resistance Standard and Test Method for BF Certification)

  • 신동홍;성기창;박광재
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제25권3호
    • /
    • pp.75-83
    • /
    • 2019
  • Purpose: There are no clear criteria for slip performance in the BF certification process, so the evaluator relies on subjective judgments depending on the field situation. Physical criteria for determining the slip performance of various floor finishes are not clear. C.S.R., the only criterion currently being used to check slip performance, may raise questions about its coverage, feasibility and reliability. Method: For an analysis of domestic standards and status, KS L 1001, KS M 3510, and KS F 2375. External standards are analyzed for ADA Standard, ANSI Standard, and BS EN Standard. Analyze the test methods and evaluation criteria of O-Y-PSM, BPT, and the dynamic slip resistance test used in these criteria. It also presents an improvement plan for the rational presentation of standards. Results: To date, various kinds of test methods and measuring devices of the slip resistance coefficient have been developed, but there are not many ways to trust useful results related to user safety. Reliability and thoroughly verified test methods and criteria should be used to assess the slip performance of the floor. In order to improve the standard for the evaluation of slip performance in Korea, the existing standard should first be raised to the same level as the overseas standard, and the application of the discriminatory standard should be applied considering the characteristics and usage patterns of each space. Implication: Currently, Korean standards propose various test methods, but the proper use of test methods, scope and assessment criteria are not established, so improvement of the comprehensive standard is necessary.

점도변화에 따른 바닥 오염물질의 미끄러짐 저항 특성 (Slip Resistance of Contaminants on the Floor for Variation of Viscosity)

  • 박재석;오환섭
    • 한국안전학회지
    • /
    • 제27권5호
    • /
    • pp.185-189
    • /
    • 2012
  • While there is no standards on slip risk for contaminants on surface, glycerol is described in standard contaminant for measuring coefficient of friction(COF) and slip resistance such as ISO 13287. But that is just used to measure the slip resistance of surface materials and shoes not to evaluate the contaminant materials. Therefore the objective of this study was to find out the relationship between standard contaminant and the contaminants used usually at the workplaces. For this, some measurement criteria were acquired from the analysis based on biomechanics and kinetics of human gait during slips. The slip resistance according to viscosity of the contaminants was measured applying the criteria and slip probability was determined by the gait analysis. Some factors which should be considered when measuring the slip resistance were identified. The velocity, acceleration, contact time and contact pressure should be 1 m/sec, 10 $m/sec^2$, 350 kPa and less than 0.5sec respectively. The variation of viscosity according to temperature for working oils was different from that of standard contaminant. The static coefficient of friction (SCOF) of working oils was almost 0.5 times as large as the SCOF of standard contaminant. So it was assumed to be difficult to compare the contaminants at the workplaces with the glycerol as a standard contaminant for estimating the slip risk.

Direct shear behavior of concrete filled hollow steel tube shear connector for slim-floor steel beams

  • Hosseinpour, Emad;Baharom, Shahrizan;Badaruzzaman, Wan Hamidon W.;Shariati, Mahdi;Jalali, Abdolrahim
    • Steel and Composite Structures
    • /
    • 제26권4호
    • /
    • pp.485-499
    • /
    • 2018
  • In this paper, a hollow steel tube (HST) shear connector is proposed for use in a slim-floor system. The HST welded to a perforated steel beam web and embedded in concrete slab. A total of 10 push-out tests were conducted under static loading to investigate the mechanical behavior of the proposed HST connector. The variables were the shapes (circular, square and rectangular) and sizes of hollow steel tubes, and the compressive strength of the concrete. The failure mode was recorded as: concrete slab compressive failure under the steel tube and concrete tensile splitting failure, where no failure occurred in the HST. Test results show that the square shape HST in filled via concrete strength 40 MPa carried the highest shear load value, showing three times more than the reference specimens. It also recorded less slip behavior, and less compressive failure mode in concrete underneath the square hollow connector in comparison with the circular and rectangular HST connectors in both concrete strengths. The rectangular HST shows a 20% higher shear resistance with a longer width in the load direction in comparison with that in the smaller dimension. The energy absorption capacity values showed 23% and 18% improvements with the square HST rather than a headed shear stud when embedded in concrete strengths of 25 MPa and 40 MPa, respectively. Moreover, an analytical method was proposed and predicts the shear resistance of the HST shear connectors with a standard deviation of 0.14 considering the shape and size of the connectors.