• 제목/요약/키워드: Floor Slabs

검색결과 146건 처리시간 0.03초

바닥판의 휨강성이 고층건물의 지진거동에 미치는 영향 (The Effect of the flexural stiffness of Floor Slabs on The Seismic Response of Multi-story Building Structures)

  • 김현수
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2000년도 춘계 학술발표회 논문집 Proceedings of EESK Conference-Spring
    • /
    • pp.170-177
    • /
    • 2000
  • Recently many high-rise apartment buildings are constructed using the box system which is composed only of concrete walls and slabs. Commercial softwares such as ETABS used for the analysis of high-rise apartment buildings are employing the rigid diaphragm assumption for simplicity in the analysis procedure. In general the flexural stiffness of floor slabs are ignored in the analysis, This assumption may be reasonable for the estimation of seismic response of framed structures. But in the case of the box system used in the apartment buildings floor slabs has major effects on the lateral stiffness of the structure. So if the flexural stiffness of slabs in the box system is ignored the lateral stiffness may be significantly underestimated, For these reasons it is recommended to use plate elements to represent the floor slabs. In the study A typical frame structure and a box system structure are chosen as the example structure. When a 20 story frame structure is subjected to the static lateral loads the displacements of the roof are 15.33cm and 17.52cm for the cases with and without the flexural stiffness of the floor slabs. And in case of box system the roof displacement was reduced from 16.18cm to 8.61cm The model without the flexural stiffness of floor slabs turned out to elongate the natural periods of vibration accordingly.

  • PDF

A Study on Floor Impact Sound Insulation Performance of Cross-Laminated Timber (CLT): Focused on Joint Types, Species and Thicknesses

  • Yeon-Su HA;Hyo-Jin LEE;Sang-Joon LEE;Jin-Ae SHIN;Da-Bin SONG
    • Journal of the Korean Wood Science and Technology
    • /
    • 제51권5호
    • /
    • pp.419-430
    • /
    • 2023
  • In this study, the floor impact sound insulation performance of Korean domestic Cross-Laminated Timber (CLT) slabs was evaluated according to their joint types, species and thicknesses in laboratory experiments. The sound insulation performance of the CLT has not been investigated before, thus, this study was conducted to quantify basic data on floor impact sound insulation performance of CLT slabs. 5-ply and 150 mm thick CLT panels made of 2 species, Larix kaempferi and Pinus densiflora, were used for the study. The CLT panels were assembled by 3 types of inter-panel joints to form floor slabs: spline, butt and half-lap. And the 150 mm thick Larix CLT slabs were stacked to the thicknesses of 300 mm and 450 mm. The heavy-weight floor impact sound insulation performance of the 150 mm CLT slabs were evaluated to be 70 dB for the Larix slabs and 71.6 dB for the Pinus slabs, and the light-weight floor impact sound insulation performance, 78.3 dB and 79.6 dB, respectively. No significant difference in the sound insulation performance was found between the slabs of the 2 species or among the 3 types of joints. The reduction of 1 dB in the heavy-weight floor impact sound and 1.6 dB in the light-weight floor impact sound per 30 mm increase in thickness were confirmed through the experiments. This study can be viewed as the basic research for the evaluation of floor impact sound insulation performance of CLT.

건물바닥 슬래브의 동특성 분석을 위한 가진기와 Impact Hammer의 성능 비교 (Comparison of Performance of the Exciter and Impact Hammer Test for Dynamic Characteristics Analysis of Floor Slabs)

  • 안상경;문영종;오정근
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.117-120
    • /
    • 2007
  • The floor slabs of building structures are often subjected to the periodic force which is induced by vibrating machines or human activity(walking, jumping, running etc). These periodic forces cause excessive oscillation. In order to examine the dynamic characteristics of floor slabs, the dynamic characteristics test is accomplished. Generally, the Impact Hammer and Dynamic Exciter test is used to dynamic characteristics test. But the Impact Hammer test is not suitable to apply in building slabs. In this paper, It compared the performance of the Exciter and Impact Hammer test for dynamic characteristics analysis of floor slabs.

  • PDF

프리캐스트 콘크리트 바닥판의 수직진동 허용치 평가 (Performance Evaluation of Vertical Vibration of Precast Concrete Slabs)

  • 허석재;이상현;조승호;정란;김성배;박성순
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.662-667
    • /
    • 2009
  • In this study, the serviceability of Waffle shaped(WAS) and Double-Tee(DT) precast concrete slabs was evaluated and compared based on the vertical acceleration magnitude induced by walking and heel drop loads. Tests were conducted for practical building structures (a shopping mall in Hanam) of which floor systems used WAS and DT slabs. Natural frequencies of the slabs were similar to those obtained by using analytical models. The measured acceleration level was evaluated by vertical floor acceleration criteria presented by ISO-2631, AIJ(1991, Japan), and a previous study regarding floor vibration limit. Test results showed that both WAS and DT slabs satisfied all the criteria and the maximum acceleration level of WAS slabs was lower than that of DT slabs.

  • PDF

Structural Evaluation and Remediation of Floor Slab Deflection

  • Park, Ki-Dong;Kim, Dae-Young;Joung, Dae-Ki
    • 한국공간구조학회:학술대회논문집
    • /
    • 한국공간구조학회 2008년도 춘계 학술발표회 논문집
    • /
    • pp.61-65
    • /
    • 2008
  • A 4-story reinforced concrete structure built above an underground parking garage shows some slab deflections, and the deflections of the concrete floor slabs are proposed to be alleviated by the application of light-weight topping material in conjunction with localized strengthening of the slabs. The application of light-weight concrete topping on the existing slab has been simulated and its performance to anticipated loads has been analyzed. The application of light-weight topping material imposes additional weight on the exiting floor slabs. This added weight on the existing slabs causes over-stressing of the slabs. This over-stressing can be alleviated by enhancing the load carrying capacity of the existing slabs. Additional load carrying capacity in the existing slabs can be developed by localized strengthening of the slabs utilizing techniques such as the application of fiber-reinforced composites on the bottom surface of the slabs, and application of fiber-reinforced composites adequately complements the capacity of the existing slabs to bear the additional load imposed by light-weight leveling material. Additional moments in the beam and columns induced by the application of the light-weight topping material were tabulated and compared with capacity. The moment D/C ratios of the beam and columns are well the range of acceptable limits, and the beam and columns are not overstressed by the application of the surcharge.

  • PDF

Efficient models for analysis of a multistory structure with flexible wings

  • Moon, Seong-Kwon;Lee, Dong-Guen
    • Structural Engineering and Mechanics
    • /
    • 제13권5호
    • /
    • pp.465-478
    • /
    • 2002
  • This study lays emphasis on the development of efficient analytical models for a multistory structure with wings, including the in-plane deformation of floor slabs. For this purpose, a multistory structure with wings is regarded as the combination of multistory structures with rectangular plan and their junctions. In addition, a multistory structure with a rectangular plan is considered to be an assemblage of two-dimensional frames and floor slabs connecting two adjacent frames at each floor level. This modeling, concept can be easily applied to multistory structures with plans in the shape of L, T, Y, U, H, etc. To represent the in-plane deformation of floor slabs efficiently, a two-dimensional frame and the floor slab connecting two adjacent frames at each floor level are modeled as a stick model with two degrees of freedom per floor and a stiff beam with shear deformations, respectively. Three models are used to investigate the effect of in-plane deformation of the floor slab at the junction of wings on the seismic behavior of structures. Based on the comparison of dynamic analysis results obtained using the proposed models and three-dimensional finite element models, it could be concluded that the proposed models can be used as an efficient tool for an approximate analysis of a multistory structure with wings.

Seismic behavior of RC building by considering a model for shear wall-floor slab connections

  • Soleimani-Abiat, Mehdi;Banan, Mohammad-Reza
    • Computers and Concrete
    • /
    • 제16권3호
    • /
    • pp.381-397
    • /
    • 2015
  • Connections are the most important regions in a structural system especially for buildings in seismic zones. In R.C. structures due to large dimensions of members and lack of cognition of the stress distribution in a connection, reaching a comprehensive understanding of the connection behaviors becomes more complicated. The shear wall-to-floor slab connections in lateral load resisting systems have a potential weakness in transferring loads from slabs to shear walls which might change the path of load transformation to shear walls. This paper tries to investigate the effects of seismic load combinations on the behavior of slabs at their connection zones with the shear walls. These connection zones naturally are the most critical regions of the slabs in RC buildings. The investigation carried on in a simulated environment by considering three different structures with different shear wall layout. The final results of our study reveal that layout of shear walls in a building significantly affects the magnification of forces developed at the shear wall-floor slab connections.

Experimental investigation of longitudinal shear behavior for composite floor slab

  • Kataoka, Marcela N.;Friedrich, Juliana T.;El Debs, Ana Lucia H.C.
    • Steel and Composite Structures
    • /
    • 제23권3호
    • /
    • pp.351-362
    • /
    • 2017
  • This paper presents an experimental study on the behavior of composite floor slab comprised by a new steel sheet and concrete slab. The strength of composite slabs depends mainly on the strength of the connection between the steel sheet and concrete, which is denoted by longitudinal shear strength. The composite slabs have three main failures modes, failure by bending, vertical shear failure and longitudinal shear failure. These modes are based on the load versus deflection curves that are obtained in bending tests. The longitudinal shear failure is brittle due to the mechanical connection was not capable of transferring the shear force until the failure by bending occurs. The vertical shear failure is observed in slabs with short span, large heights and high concentrated loads subjected near the supports. In order to analyze the behavior of the composite slab with a new steel sheet, six bending tests were undertaken aiming to provide information on their longitudinal shear strength, and to assess the failure mechanisms of the proposed connections. Two groups of slabs were tested, one with 3000 mm in length and other with 1500 mm in length. The tested composite slabs showed satisfactory composite behavior and longitudinal shear resistance, as good as well, the analysis confirmed that the developed sheet is suitable for use in composite structures without damage to the global behavior.

천장구조를 이용한 공동주택 바닥충격음 차단성능 개선에 관한 연구 (A Study on the Improvement Floor Impact Sound Insulation by Ceiling Structure in Apartment Houses)

  • 기노갑;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.1038-1042
    • /
    • 2007
  • The factors influencing the floor impact sound insulation include floor finishing materials, shock absorbing floors (slabs included), and ceiling structures. The ceilings of the apartment houses, currently built in Korea, are set up with lower parts of slabs and paper finishing, or with double floors for protecting against floor impact sounds in order to improve the sound insulating performance. The most common the method of ceiling structure construction consists of 'wood boarded frames + Gypsum boards + ceiling papers', which is called the wood boarded frame method. This study aimed to measures and evaluates floor impact sound insulation by which the ceiling space are widened according to suppression system is added in apartment house ceiling structure.

  • PDF

와플형과 더블티형 프리캐스트 콘크리트 바닥판의 수직진동 사용성 평가 (Serviceability Performance Evaluation of Vertical Vibration of Waflle Shape and Duble-Tee Precast Concrete Slabs)

  • 신재상;정란
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제14권4호
    • /
    • pp.62-69
    • /
    • 2010
  • 본 연구는 PC 부재인 와플형상을 갖는 슬래브와 더블티형 슬래브에 대하여 보행 및 발뒤꿈치 가진등의 수직진동 하중을 대한 실험과 해석을 수행하여, 각각의 사용성을 비교 검토하였다. 수직진동하중에 대한 실험은 와플형 및 더블티형 슬래브가 모두 시공된 하남시에 위치한 상업시설을 대상으로 수행하였다. 실험결과에 대한 사용성 검토는 국제표준화기구의 ISO 2631-2와 일본건축학회의 건축물의 진동에 관한 거주성능 평가지침 동해설에서 제시한 기준을 바탕으로 평가하였다. 실험결과, 와플형 및 더블티형 슬래브 모두 각 기준에 제시된 상업시설 바닥진동 제한범위에 만족하는 것으로 나타나 사용성이 우수한 것으로 나타났으나, 최대가속도 응답은 와플형 슬래브가 더블티형 슬래브보다 낮게 발생하였다.