• 제목/요약/키워드: Floor Number Determination

검색결과 19건 처리시간 0.02초

공동주택의 관리비 추정모델 연구 (A Study on the Maintenance Cost Estimation Model of the Apartment Housing)

  • 이강희;양재혁;채창우
    • 한국주거학회논문집
    • /
    • 제21권2호
    • /
    • pp.59-67
    • /
    • 2010
  • The maintenance cost plays a important role to plan the scale of the apartment housing such as a number of household, building area and building type. Therefore, it is required to forecast the cost considering various maintenance characteristics. The maintenance characteristics are floor area, number of household, heating type, site area and etc.. In addition, the maintenance cost are classified into 5 area. These are a personal expense, facility maintenance cost, energy and water cost, insurance and sanitary cost. These five cost area are related with various characteristics and brought up the estimation model using the stepwise multiple regression analysis. The energy and heating cost share over the 50% in the total cost and the personal expense cost shares about 40%. The personal expense cost per area is 5,272 won/$m^2{\cdot}yr$ irregardless of heating type and the district heating type is a higher cost than other type. In facility maintenance cost, the central heating type is 2,015 won/$m^2{\cdot}yr$ and higher than other type. The estimation models have good statistics in each model. Most of the model have a determination coefficient over 0.7 and Durbin Watson value between 1.5 and 2.5.

Influence of infill walls on modal expansion of distribution of effective earthquake forces in RC frame structures

  • Ucar, Taner
    • Earthquakes and Structures
    • /
    • 제18권4호
    • /
    • pp.437-449
    • /
    • 2020
  • It is quite apparent that engineering concerns related to the influence of masonry infills on seismic behavior of reinforced concrete (RC) structures is likely to remain relevant in the long term, as infill walls maintain their functionalities in construction practice. Within this framework, the present paper mainly deals with the issue in terms of modal expansion of effective earthquake forces and the resultant modal responses. An adequate determination of spatial distribution of effective earthquake forces over the height of the building is highly essential for both seismic analysis and design. The possible influence of infill walls is investigated by means of modal analyses of two-, three-, and four-bay RC frames with a number of stories ranging from 3 to 8. Both uniformly and non-uniformly infilled frames are considered in numerical analyses, where infill walls are simulated by adopting the model of equivalent compression strut. Consequently, spatial distribution of effective earthquake forces, modal static base shear force response of frames, modal responses of story shears from external excitation vector and lateral floor displacements are obtained. It is found that, infill walls and their arrangement over the height of the frame structure affect the spatial distribution of modal inertia forces, as well as the considered response quantities. Moreover, the amount of influence varies in stories, but is not very dependent to bay number of frames.

The ground response curve of underwater tunnels, excavated in a strain-softening rock mass

  • Fahimifar, Ahmad;Ghadami, Hamed;Ahmadvand, Masoud
    • Geomechanics and Engineering
    • /
    • 제8권3호
    • /
    • pp.323-359
    • /
    • 2015
  • This paper presents an elasto-plastic model for determination of the ground response curve of a circular underwater tunnel excavated in elastic-strain softening rock mass compatible with a nonlinear Hoek-Brown yield criterion. The finite difference method (FDM) was used to propose a new solution to calculate pore water pressure, stress, and strain distributions on periphery of circular tunnels in axisymmetric and plain strain conditions. In the proposed solution, a modified non-radial flow pattern, for the hydraulic analysis, is utilized. To evaluate the effect of gravitational loads and variations of pore water pressure, the equations concerning different directions around the tunnel (crown, wall, and floor) are derived. Regarding the strain-softening behavior of the rock mass, the stepwise method is executed for the plastic zone in which parameters of strength, dilatancy, stresses, strains, and deformation are different from their elasto-plastic boundary values as compared to the tunnel boundary values. Besides, the analytical equations are developed for the elastic zone. The accuracy and application of the proposed method is demonstrated by a number of examples. The results present the effects of seepage body forces, gravitational loads and dilatancy angle on ground response curve appropriately.

Stochastic finite element based seismic analysis of framed structures with open-storey

  • Manjuprasad, M.;Gopalakrishnan, S.;Rao, K. Balaji
    • Structural Engineering and Mechanics
    • /
    • 제15권4호
    • /
    • pp.381-394
    • /
    • 2003
  • While constructing multistorey buildings with reinforced concrete framed structures it is a common practice to provide parking space for vehicles at the ground floor level. This floor will generally consist of open frames without any infilled walls and is called an open-storey. From a post disaster damage survey carried out, it was noticed that during the January 26, 2001 Bhuj (Gujarat, India) earthquake, a large number of reinforced concrete framed buildings with open-storey at ground floor level, suffered extensive damage and in some cases catastrophic collapse. This has brought into sharp focus the need to carry out systematic studies on the seismic vulnerability of such buildings. Determination of vulnerability requires realistic structural response estimations taking into account the stochasticity in the loading and the system parameters. The stochastic finite element method can be effectively used to model the random fields while carrying out such studies. This paper presents the details of stochastic finite element analysis of a five-storey three-bay reinforced concrete framed structure with open-storey subjected to standard seismic excitation. In the present study, only the stochasticity in the system parameters is considered. The stochastic finite element method used for carrying out the analysis is based on perturbation technique. Each random field representing the stochastic geometry/material property is discretised into correlated random variables using spatial averaging technique. The uncertainties in geometry and material properties are modelled using the first two moments of the corresponding parameters. In evaluating the stochastic response, the cross-sectional area and Young' modulus are considered as independent random fields. To study the influence of correlation length of random fields, different correlation lengths are considered for random field discretisation. The spatial expectations and covariances for displacement response at any time instant are obtained as the output. The effect of open-storey is modelled by suitably considering the stiffness of infilled walls in the upper storey using cross bracing. In order to account for changes in soil conditions during strong motion earthquakes, both fixed and hinged supports are considered. The results of the stochastic finite element based seismic analysis of reinforced concrete framed structures reported in this paper demonstrate the importance of considering the effect of open-storey with appropriate support conditions to estimate the realistic response of buildings subjected to earthquakes.

A Study on Minimum Cabin Crew Requirements for Korean Low Cost Air Carriers

  • Yoo, Kyung-In;Kim, Mun-Kyung
    • 항공우주정책ㆍ법학회지
    • /
    • 제33권2호
    • /
    • pp.291-314
    • /
    • 2018
  • 최근 3년간 우리나라의 저비용항공사는 총 6개사(소형항공운송업 항공사 포함 8개사)로서 국내시장 점유 뿐 아니라 일본, 중국, 동남아 및 미국령까지 그 영역을 확대하고 있다. 현재에도 약 3개 항공사가 저비용항공사로 출범하고자 항공운송사업증명을 신청한 상태로서 이 확장세는 지속될 전망이다. 이러한 국내 및 외국의 저비용항공사의 공격적인 항공사 운영 실태에 대응하며 경쟁력을 제고하고자 각 저비용항공사는 객실서비스 증진에 많은 전략을 강구하고 있다. 따라서 객실승무원의 업무량이 확장세에 비례하여 증가되어 안전업무 수행 능력과 직결되는 피로를 가중시키고 있다. 우리나라는 승객 좌석 50석 당 최소 1인의 객실승무원이 탑승하도록 항공안전법 시행규칙에 규정하고 있으며, 이를 기반으로 모든 저비용항공사에는 최소 객실승무원만 탑승하고 있다. 때로는 객실승무원의 주 업무인 비상 시 비상탈출에 필요한 비상구(창문형 비상구 제외)에 착석이 불가능하게 되어 비상 시 승객의 혼란을 야기할 수밖에 없는 상황에 처해 있다. 또한 최소 객실승무원 중 1인이 부상 등으로 업무수행 불능상태가 되면 비상탈출 업무를 수행하는데 큰 장애요소로 작용하게 되고, 정상상황에서도 최소 객실승무원의 성원을 이룰 수 없으므로 위규가 되어, 모든 승객이 다른 가용한 항공사 비행편으로 이동할 수밖에 없는 불편을 초래하게 된다. 국제민간항공협약 부속서 6에는 최소 객실승무원의 수를 정할 때 안전하고 신속한 비상탈출을 위하여 승객좌석 수 또는 탑승 승객 수만을 기반으로 정하도록 국제표준으로 규정하고 있다. 객실안전의 강화 및 승객의 편의를 위하여 객실승무원의 다양한 업무특성(서비스, 안전, 보안, 응급처치)에서 발생할 수 있는 피로 및 비상구 착석(창문형 비상구 제외)을 최소 객실승무원 수 산정에 고려할 필요가 있다. 정부의 항공사 관리.감독 차원에서도 저비용항공사 객실승무원의 업무량에 기인한 피로, 비상구 착석불가 상황 등을 검토하여 최소 객실승무원 수 규정에 반영함으로써 승객과 승무원의 객실안전을 강화할 필요가 있다고 사료된다.

다중 회귀분석 기반 도시형 생활주택의 공사기간 산정 모델 개발 (Development of a Model for Calculating the Construction Duration of Urban Residential Housing Based on Multiple Regression Analysis)

  • 김준상;김영석
    • 토지주택연구
    • /
    • 제12권4호
    • /
    • pp.93-101
    • /
    • 2021
  • 국내 소규모 가구가 점차적으로 증가함에 따라 소규모 가구를 위한 주거공급 정책에 대한 중요성이 높아지고 있다. 이러한 중요성에 따라 정부에서는 소규모 가구를 위한 도시형 생활주택을 지속적으로 공급해오고 있다. 도시형 생활주택은 공동주택, 일반 업무시설과 동일하게 분양 및 임대 사업이므로 발주자는 프로젝트 기획단계에서 적정공사기간을 산정하는 것은 중요하다. 그러나, 선행연구에서는 대규모 건축물의 공사기간을 산정할 수 있는 모델이 존재하나 도시형 생활주택과 같은 소규모 건축물에 대한 적정 공사기간 산정 모델은 부재한 것으로 분석되었다. 따라서 본 연구의 목적은 기획단계에서 발주자가 적정 공사기간을 산정할 수 있는 다중 회귀분석 기반 도시형 생활주택의 공사기간 산정 모델을 개발 및 검증하는 것이다. 개발된 모델에 입력되는 독립변수는 연면적, 수도권, 지하층수, 지상층수, 주 건축물 수, 강원권의 총 6개이며, 개발된 모델의 수정된 결정계수(Ra2)는 0.547로 분석되었다. 개발된 모델의 성능은 RMSE의 경우 171.26일, MAPE의 경우 26.53%로 도출되었다. 본 연구를 통해 개발된 모델은 발주자에게 신뢰성 있는 공사기간 산정 결과를 제공할 수 있을 것으로 기대된다.

다중 카메라 네트워크 가상의 관심선(Line of Interest)을 활용한 건물 내 재실자 인원 계수 방법론 개발 (Developing an Occupants Count Methodology in Buildings Using Virtual Lines of Interest in a Multi-Camera Network)

  • 천휘경;박찬혁;지석호;노명일
    • 대한토목학회논문집
    • /
    • 제43권5호
    • /
    • pp.667-674
    • /
    • 2023
  • 건물에서 재난이 발생할경우, 건물 내 인원을 신속히 구조하여 사상자를 최소화하는 것은 단연 최우선순위가 된다. 이러한 구조활동을 위해서는 건물내 어디에 몇 명이 있는지를 알아야 하는데, 실시간으로 알기가 어렵다보니 주로 건물주나 경비원 등 관계자의 진술이나 층별 면적, 수용 인원과 같은 기초자료에 의존하는 실정이다. 따라서 빠르고 정확하게 재실인원 정보를 파악하여 현장에 대한 불확실성을 낮추고 골든타임내 효율적인 구조활동을 지원하는 것이 반드시 필요하다. 본 연구는 컴퓨터 비전 알고리즘을 활용하여 이미 건물에 설치되어 있는 여러대의 CCTV 가 촬영한 이미지 로부터 건물 위치별 재실인원을 계수하는 방법론을 제시한다. 계수 방법론은 (1)카메라별 관심선(LOI) 설정을 통한 다중카메라 네트워크 환경구축, (2)딥러닝을 활용한 모니터링 구역내 사람 탐지 및 추적, (3)다중 카메라 네트워크 환경을 고려한 인원 합산 세단계로 구성된다. 제안된 방법론은 5층 건물을 대상으로 세 개의 시간대 별로 수행된 현장 실험을 통해 검증되었다. 최종 결과는 89.9%의 정확도로 재실자를 인식하는 것으로 나타났으며, 층별, 구역별 합산결과도 93.1%, 93.3%의 정확도로 우수했다. 층별 평균MAE와 RMSE는 각각 0.178과 0.339이었다. 이 처럼 실시간으로 제공하는 건물내 재실자 정보는 초기 재난 대응단계에 신속하고 정확한 구조활동을 지원 할 수있다.

주차장 램프의 종단곡선 제원 산정에 관한 연구 (Determination of Dimension of Vertical Curve Elements at Parking Lot Ramps)

  • 권성대;김윤미;홍정표;하태준
    • 대한토목학회논문집
    • /
    • 제35권3호
    • /
    • pp.607-616
    • /
    • 2015
  • 최근 설치되는 주차장은 한정된 지상공간 및 건축물의 대형화, 지하화로 인하여 옥상이나 지하에 설치하는 것이 일반화되었으며 주차장 램프의 경사를 17%이하로 규제하고 있다. 하지만 주차장 램프 진입시 램프의 종단경사가 다소 급한 경우에 자동차의 차체와 경사로 바닥이 부딪치는 현상을 경험하거나 또는 경사로 바닥이 손상된 흔적을 자주 접하게 된다. 이에 본 연구는 주차장 램프의 시 종점부에 대한 종단해석을 통하여 자동차 및 경사로 바닥과 접촉되지 않는 적정한 종단곡선의 제원을 제시하여 구조물의 손상을 방지하고 운전자 및 동승자의 승차감과 안전성 확보하는데 도움이 되고자 한다. 본 연구에서는 첫 번째로 불특정 다수가 많이 이용하는 대형 건축물 주차장 램프를 대상으로 현장조사를 실시하여 문제점을 도출하였다. 두 번째로 주차장의 시점부 및 종점부에 대한 이론적 분석으로 상호 접촉여부를 평가하였으며 마지막으로 주차장 램프의 종단곡선 제원 산정을 위한 종단곡선 해석과 제원을 제시하였다. 또한, 종단곡선의 길이에 대한 분석 값과 일반식을 이용한 산정 값이 최소 0.4mm에서 최대 5mm이내의 차이로 적은 오차를 보이는 것을 검증하였다. 향후 본 연구를 통해 제시된 종단곡선을 적용할 경우 자동차 및 구조물의 손상을 방지하고 운전자의 승차감 및 안전성 확보는 물론 주차장 램프의 종단 설치기준이 재정립 될 것으로 기대된다.

다단식 벼육묘시설을 활용한 고온기 어린잎채소 재배 적정 위치 선발 (Determination of Appropriate Location for Baby Leaf Vegetable in Multi Bench System of Rice Seedling Nursery Facility During High Temperature Periods)

  • 김재경;김일섭;강호민;최기영
    • 생물환경조절학회지
    • /
    • 제28권4호
    • /
    • pp.286-292
    • /
    • 2019
  • 본 실험은 벼 육묘장에 설비된 시설과 장비를 이용하여 어린잎채소 재배 가능성을 검토하면서 층위에 따른 적합한 품종을 선발하기 위해 수행하였다. 공시 작물은 국화과 3종('진빨롤라', '로메인화이트', 왕고들빼기), 배추과 2종(다채, 적다채) 및 아마란스이며, 고온기에 벼육묘판($L60{\times}W30{\times}H2cm$)에서 재배하였다. 파종된 벼육묘판은 벼 다단재배상($L120{\times}W60{\times}H195cm$, 10층)의 저층(지면으로부터 15cm, 1층), 중간층(지면 115cm, 4층), 고층(지면 175cm, 7층)에 임의 배치하였다. 관수는 자동 관수시스템을 이용하여 하루 2~3회 스프레이 관수하였고, 생육조사는 어린잎채소 적정 크기에(초장 10cm 이내) 도달하는 시점에 수확하여 생육과 색도를 조사하였다. 재배 기간 동안(2016년 6월 30일~7월 31일) 주간 온도는 $27.4{\sim}28.1^{\circ}C$로 층위 간 차이가 없었으나, 고층 일사량은 저층, 중간층보다 약 37%, 22% 높았다. 공시작물의 엽장, 엽폭, 엽수는 중, 고층에서 높은 경향을 보였으나 품종별 생체중은 층위에 따라 차이를 보였다. 누적 광량에 따른 생육 상관성을 분석한 결과 아마란스는 모든 생육 요소가 누적 광량과 높은 상관성을 보인 반면, 나머지 품종들은 생육 요소에 따라 차이를 보였다. 엽생육, 생체중 및 엽색도를 분석한 결과 벼 다단 재배상의 층위에 따른 어린잎채소의 적정 층위로 고층에서는 아마란스와 적다채, 왕고들빼기와 다채는 중간층과 고층에서, '로메인화이트'는 중간층 재배가 적합하였다. '진빨롤라'는 저층에서 엽장과 생체중이 가장 좋았으나, 적색 발현이 낮아 고층 재배가 적합하였다.