콘크리트 슬래브와 바닥 상부구조가 일체된 바닥구조의 바닥충격음 (Floor Impact Noise Level for Concrete Slab Integrated with Floor Finishing Layers)

  • 문대호;오양기;정갑철;박홍근
    • 한국소음진동공학회논문집
    • /
    • 제26권2호
    • /
    • pp.130-140
    • /
    • 2016
  • Floating floor is most commonly used at apartment houses in Korea for thermal insulation and reducing impact noise. But it in proven that the floating floor is not effective for reducing the floor impact noise in low frequency range. In most cases, impact sound pressure level under 63 Hz frequency band were actually increased by the resonance of resilient material, lightweight concrete and the finishing mortar installed on it. In this paper, an integrated floor system consist of 70 mm light weight concrete and 40 mm finishing mortar successively installed on the concrete slab was suggested to avoid the resonance. Integrated floor system increases total flexural stiffness and mass per unit area. The natural frequencies of first and second vibration mode were increased and acceleration response and floor impact sound level was decreased in all measurement range.

음향모드를 고려한 공동주택 중량충격음 소음해석 (Numerical Analysis of Heavy-weight Impact Noise for Apartment Units Considering Acoustic Mode)

  • 문대호;박홍근;황재승;홍건호;임주혁
    • 한국소음진동공학회논문집
    • /
    • 제22권7호
    • /
    • pp.676-684
    • /
    • 2012
  • Numerical analysis was performed to investigate the heavy-weight impact noise of apartment houses. The FEM is practical method for prediction of low-frequency indoor noise. The results of numerical analysis, the shape of the acoustic modes in room-2 are similar to that of acoustic pressure field at the fundamental frequency of acoustic modes. And the acoustic pressure was amplified at the natural frequency of the acoustic modes and structural modes. The numerical analysis result of sound pressure level at 63 Hz and 125 Hz octave-band center frequency are similar to the test results, but at 250 Hz and 500 Hz have some errors. Considering most of bang-machine force spectrum exists below 100 Hz, the noise at 250 Hz and 500 Hz are not important for heavy-weight impact noise. Thus, the FEM numerical analysis method for heavy-weight impact noise can apply to estimate heavy-weight impact noise for various building systems.

국내 PC 아파트 접합부 누수 방지를 위한 마감상세 분석 (Analysis of finishing details to Prevent leakage of PC Apartment Joints in Korea)

  • 김태호;고효진
    • 한국공간구조학회논문집
    • /
    • 제21권4호
    • /
    • pp.81-89
    • /
    • 2021
  • Recently, interest in OSC(Off Site Construction) is increasing due to the trend of a decrease in skilled workers and an increase in labor costs. In this regard, PC(Precast Concrete) is being reviewed for apartments, the most common type of housing in Korea. As the biggest concern for PC apartment houses, civil complaints such as inter-floor noise and leakage were presented. In this study, the details of the joints were reviewed based on the past cases of PC apartments, and the details of the recently constructed or planned PC apartments were investigated. Through this, the leakage path in the past was analyzed through the existing research literature and data. And wall type RC and PC apartment joint leakage test was performed and we found the needs for a detail of waterproof steps, sealant. Also, joint details were investigated for a rahmen type apartment housing under construction. At last, A discussion was conducted on the direction for a detailed proposal of an improved joint in the future.

승강기 소음의 주파수 특성 분석 및 평가 방법 고찰 (Analysis of frequency characteristics and evaluation methods of elevator noise)

  • 강민우;오양기
    • 한국음향학회지
    • /
    • 제40권6호
    • /
    • pp.607-614
    • /
    • 2021
  • 승강기 소음에 대한 연구는 주로 발생 원인 및 저감 방안에 대한 것이 많았다. 승강기 소음을 정확하게 측정하고 평가하는 방법에 대해서는 아직 연구가 미비하다. 측정방법에 대해서는 국제표준으로 제정하여 측정 방법이 있지만 그것 또한 고층아파트에 적용하기 힘들고, 승강기 소음의 특성을 면밀히 반영하지 않은 것이 많다. 이러한 문제를 해결하고자 현행 규격에서 승강기 소음 측정 방법을 개선하는 연구가 이루어 졌다. 본 연구에서는 승강기 소음의 특성을 면밀히 파악하고자 하였다. 승강기 소음과 다른 설비기기와의 주파수 분석을 통해 승강기 소음이 다른 설비기기와는 다른 특성의 소음임을 검증 하였다. 승강기 소음은 구조전달소음으로 대표적인 구조전달소음인 중량바닥충격음과 비교 분석을 하였다. 승강기 소음과 중량바닥충격음과의 상관성은 0.9 수준으로 매우 높게 나타났다. 이 결과로 승강기 소음은 중 저주파대역이 주요한 구조전달소음이며 다른 설비기기와 함께 평가될 수 없음을 검증 하였다.

중량충격음 평가방법 변화에 따른 단일수치평가량 기여 주파수 대역 사례 분석 (Case study on frequency bands contributing the single number quantity for heavy-weight impact sound based on assessment method changes)

  • 신혜경;박상희;김경우
    • 한국음향학회지
    • /
    • 제42권6호
    • /
    • pp.565-571
    • /
    • 2023
  • 사후확인제 도입으로 현장에서의 바닥충격음 성능 측정이 의무화되고, 평가 방법이 변경되었다. 제도 변화에 따른 바닥충격음 성능 변화를 추적하기 위해서는 변경된 평가방법에 따라 중량충격음 특성이 어떻게 나타나는지에 대한 연구가 필요하다. 본 연구에서는 평면과 바닥구조가 동일한 하나의 아파트 건물에 위치한 59세대를 대상으로 충격원 및 평가지표에 따라 단일수치평가량을 결정하는 주파수 대역의 기여율을 분석하였다. 단일수치평가량에 따른 주파수대역별 기여도 산출방법이 상이하여 단순 비교는 어려우나, 사후확인제 도입 이전 평가방법(뱅머신 측정 및 L'i,Fmax,AW으로 평가)에서는 63 Hz가 미치는 기여율은 평균 80.8 %로 나타났으며, 125 Hz가 미치는 기여율은 평균 19.2 %으로 나타났다. 현행 평가방법(고무공 측정 및 L'iA,Fmax으로 평가) 에서는 기여율은 50 Hz ~ 80 Hz에서 평균 33.1 %, 100 Hz ~ 160 Hz에서 평균 58.7 %, 200 Hz ~ 315 Hz에서 평균 6.9 %, 400 Hz ~ 630 Hz에서 평균 1.3 %으로, 63 Hz 대역의 기여도가 낮아진 것으로 나타났다. 이 결과는 대상 공동주택에 대한 사례 분석 내용으로, 더 다양한 공동주택에 대한 측정 데이터를 분석할 필요가 있다.