• 제목/요약/키워드: Floor Field Model

검색결과 71건 처리시간 0.022초

화물유 펌프실의 환기특성에 관한 연구 (A Study on Ventilation Characteristics of Cargo-oil pump room)

  • 박찬수;조대환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제24권1호
    • /
    • pp.134-141
    • /
    • 2000
  • In this study, a scaled model chamber was built to investigate ventilation characteristics of the Under floor Air-conditioning System. Experimental study was performed in model for cargo-oil pump room with inlet and outlet by visualization equipment with laser apparatus. Instant simultaneous velocity vectors at whole field were measured by 2-D PIV system(CACTUS'2000) which adopted two-frame grey-level cross correlation algorithm. The flow pattern reveals the large scale counterclockwise forced-vortex rotation from upside louver to lower scupper toward diagonal corner and also found small eddies at bottom layer

  • PDF

IT용 초소형부품의 불량검출과 산업현장의 재해방지 효과 (The Effect of Disaster Prevention of Industrial Field and Failure Detection of Very Small Components for IT)

  • 박대영;정양근;최선미;변재영;최원식
    • 한국산업융합학회 논문집
    • /
    • 제18권1호
    • /
    • pp.18-29
    • /
    • 2015
  • This paper presents a feasibility study of a fresh air load reduction system by using an underground double floor space. The system was introduced into a real building and was examined by the field measurement. Judging from the measurements during three years(1999~2001), the state of the system operation was very stable through this period and it was clear that the system contributes to reduction of energy consumption for air-conditioning. Futhermore, a simulation model used the simple heat diffusion equation was developed to simulate its thermal characteristics and performances. The simulations resulted in air temperature in good agreement with the measurements. Also, from the result of numerical analysis, it is clear that the amount of heat supply by using this system is more than the amount of energy loss to the room above it. Therefore, it is concluded that this systems is very useful and the proposed numerical model can be used for the prediction of system thermal performance.

Tuned mass dampers for human-induced vibration control of the Expo Culture Centre at the World Expo 2010 in Shanghai, China

  • Lu, Xilin;Ding, Kun;Shi, Weixing;Weng, Dagen
    • Structural Engineering and Mechanics
    • /
    • 제43권5호
    • /
    • pp.607-621
    • /
    • 2012
  • The Expo Culture Centre is one of the permanent buildings at the World Expo 2010 in Shanghai, China. The main structure has an oval shape and consists of 36 radial cantilever steel trusses with different lengths and inner frames made of concrete-filled rectangular steel tube members. Tuned mass dampers are used to reduce the excessive vibrations of the sixth floor that are caused by human-induced resonance. A three-dimensional analytical model of the system is developed, and its main characteristics are established. A series of field tests are performed on the structure, and the test results show that the vertical vibration frequencies of most structural cantilevers are between 2.5 Hz and 3.5 Hz, which falls in the range of human-induced vibration. Twelve pairs of tuned mass dampers weighing 115 tons total were installed in the structure to suppress the vibration response of the system. These mass dampers were tuned to the vertical vibration frequency of the structure, which had the highest possibility of excitation. Test data obtained after the installation of the tuned mass dampers are used to evaluate their effectiveness for the reduction of the vibration acceleration. An analytical model of the structure is calibrated according to the measured dynamic characteristics. An analysis of the modified model is performed and the results show that when people walk normally, the structural vibration was low and the tuned mass dampers have no effect, but when people run at the structural vibration frequency, the tuned mass dampers can reduce the floor vibration acceleration by approximately 15%.

파랑-흐름의 상호작용 하에서 지형변동에 관한 3차원 연성 수치모델의 개발 (Development of a 3-D Coupled Hydro-Morphodynamic Model between Numerical Wave Tank and Morphodynamic Model under Wave-Current Interaction)

  • 이우동;허동수
    • 대한토목학회논문집
    • /
    • 제34권5호
    • /
    • pp.1463-1476
    • /
    • 2014
  • 본 연구에서는 파랑과 흐름이 공존하는 하구 주변의 수리특성 및 지형변동특성을 이해하기 위하여 새롭게 3차원 지형변동 모델을 개발함과 더불어 3차원 파동장 모델과 양방향 연성 수치모델을 제안하였다. 그리고 파랑-흐름 공존장에서의 파고분포, 연직유속분포, 해저파이프라인 저면의 지형변동 및 고립파 내습 시에 해빈 저면 부유사 농도의 시간분포에 관한 수리모형실험결과들과 비교 분석하여 개발한 연성 수치모델을 검증하였다. 이로써 본 연구에서 개발한 연성 수치모델의 타당성 및 유효성을 확보할 수 있을 뿐만 아니라, 이 연성 수치모델이 파랑과 흐름이 공존하는 하구지역의 지형변동 예측에 적용이 가능한 것을 확인하였다.

EgresSIM을 이용한 대형건축물의 미시적 대피시뮬레이션 (Microscopic Evacuation Simulation in Large-scale Buildings using EgresSIM)

  • 곽수영;남현우;전철민
    • 한국시뮬레이션학회논문지
    • /
    • 제25권1호
    • /
    • pp.53-61
    • /
    • 2016
  • 본 논문은 미시적 대피시뮬레이션 소프트웨어인 'EgresSIM'을 소개한다. 본 논문에서 개발한 EgresSIM은 미시적 보행모델인 Floor Field Model과 이를 발전시킨 개선된 모델을 기반으로 하는 3차원 보행자 대피시뮬레이터이다. 이 소프트웨어는 많은 층과 계단, 방, 출입구 등이 있는 대형건축물에 대한 시뮬레이션이 가능하다. 또한, 수백, 수천 명의 보행자를 실내 공간에 배치하고 이들의 움직임을 3차원 뷰어를 통해 실시간으로 확인할 수 있고, 개별 보행자들이 어떤 경로로 이동하는지, 대피시간은 얼마나 소요되는지, 각각의 출구에 얼마나 많은 대피자들이 몰렸는지 등 대피 상황에 대한 상세한 결과를 산출한다. 시뮬레이션에 필요한 건물 데이터는 사전에 정의된 실내 데이터 모델에 따라 XML 파일로 구축되며, 시뮬레이션 결과 정보도 XML 로그파일로 생성된다. EgresSIM에서 지원하는 두 가지 보행모델의 민감도 파라미터를 조정함으로써 보행자들의 이동 패턴을 여러 가지로 나타낼 수 있다. 이를 통해 최단 거리 출구로 이동하는 상황, 정전이 일어난 암흑 상황 등 여러 상황을 가정한 대피시뮬레이션 수행이 가능하다.

Configuration assessment of MR dampers for structural control using performance-based passive control strategies

  • Wani, Zubair R.;Tantray, Manzoor A.;Iqbal, Javed;Farsangi, Ehsan Noroozinejad
    • Structural Monitoring and Maintenance
    • /
    • 제8권4호
    • /
    • pp.329-344
    • /
    • 2021
  • The use of structural control devices to minimize structural response to seismic/dynamic excitations has attracted increased attention in recent years. The use of magnetorheological (MR) dampers as a control device have captured the attention of researchers in this field due to its flexibility, adaptability, easy control, and low power requirement compared to other control devices. However, little attention has been paid to the effect of configuration and number of dampers installed in a structure on responses reduction. This study assesses the control of a five-story structure using one and two MR dampers at different stories to determine the optimal damper positions and configurations based on performance indices. This paper also addresses the fail-safe current value to be applied to the MR damper at each floor in the event of feedback or control failure. The model is mathematically simulated in SIMULINK/MATLAB environment. Linear control strategies for current at 0 A, 0.5 A, 1 A, 1.5 A, 2 A, and 2.5 A are implemented for MR dampers, and the response of the structure to these control strategies for different configurations of dampers is compared with the uncontrolled structure. Based on the performance indices, it was concluded that the dampers should be positioned starting from the ground floor, then the 2nd floor followed by 1st and rest of the floors sequentially. The failsafe value of current for MR dampers located in lower floors (G+1) should be kept at a higher value compared to dampers at top floors for effective passive control of multi-story structures.

The effect of impact with adjacent structure on seismic behavior of base-isolated buildings with DCFP bearings

  • Bagheri, Morteza;Khoshnoudiana, Faramarz
    • Structural Engineering and Mechanics
    • /
    • 제51권2호
    • /
    • pp.277-297
    • /
    • 2014
  • Since the isolation bearings undergo large displacements in base-isolated structures, impact with adjacent structures is inevitable. Therefore, in this investigation, the effect of impact on seismic response of isolated structures mounted on double concave friction pendulum (DCFP) bearings subjected to near field ground motions is considered. A non-linear viscoelastic model of collision is used to simulate structural pounding more accurately. 2-, 4- and 8-story base-isolated buildings adjacent to fixed-base structures are modeled and the coupled differential equations of motion related to these isolated systems are solved in the MATLAB environment using the SIMULINK toolbox. The variation of seismic responses such as base shear, displacement in the isolation system and superstructure (top floor) is computed to study the impact condition. Also, the effects of variation of system parameters: isolation period, superstructure period, size of seismic gap between two structures, radius of curvature of the sliding surface and friction coefficient of isolator are contemplated in this study. It is concluded that the normalized base shear, bearing and top floor displacement increase due to impact with adjacent structure. When the distance between two structures decreases, the base shear and displacement increase comparing to no impact condition. Besides, the increase in friction coefficient difference also causes the normalized base shear and displacement in isolation system and superstructure increase in comparison with bi-linear hysteretic behavior of base isolation system. Totally, the comparison of results indicates that the changes in values of friction coefficient have more significant effects on 2-story building than 4- and 8-story buildings.

실내환경에서의 2 차원/ 3 차원 Map Modeling 제작기법 (A 2D / 3D Map Modeling of Indoor Environment)

  • 조상우;박진우;권용무;안상철
    • 한국HCI학회:학술대회논문집
    • /
    • 한국HCI학회 2006년도 학술대회 1부
    • /
    • pp.355-361
    • /
    • 2006
  • In large scale environments like airport, museum, large warehouse and department store, autonomous mobile robots will play an important role in security and surveillance tasks. Robotic security guards will give the surveyed information of large scale environments and communicate with human operator with that kind of data such as if there is an object or not and a window is open. Both for visualization of information and as human machine interface for remote control, a 3D model can give much more useful information than the typical 2D maps used in many robotic applications today. It is easier to understandable and makes user feel like being in a location of robot so that user could interact with robot more naturally in a remote circumstance and see structures such as windows and doors that cannot be seen in a 2D model. In this paper we present our simple and easy to use method to obtain a 3D textured model. For expression of reality, we need to integrate the 3D models and real scenes. Most of other cases of 3D modeling method consist of two data acquisition devices. One for getting a 3D model and another for obtaining realistic textures. In this case, the former device would be 2D laser range-finder and the latter device would be common camera. Our algorithm consists of building a measurement-based 2D metric map which is acquired by laser range-finder, texture acquisition/stitching and texture-mapping to corresponding 3D model. The algorithm is implemented with laser sensor for obtaining 2D/3D metric map and two cameras for gathering texture. Our geometric 3D model consists of planes that model the floor and walls. The geometry of the planes is extracted from the 2D metric map data. Textures for the floor and walls are generated from the images captured by two 1394 cameras which have wide Field of View angle. Image stitching and image cutting process is used to generate textured images for corresponding with a 3D model. The algorithm is applied to 2 cases which are corridor and space that has the four wall like room of building. The generated 3D map model of indoor environment is shown with VRML format and can be viewed in a web browser with a VRML plug-in. The proposed algorithm can be applied to 3D model-based remote surveillance system through WWW.

  • PDF

A comparative study on different walking load models

  • Wang, Jinping;Chen, Jun
    • Structural Engineering and Mechanics
    • /
    • 제63권6호
    • /
    • pp.847-856
    • /
    • 2017
  • Excessive vibrations can occur in long-span structures such as floors or footbridges due to occupant?s daily activity like walking and cause a so-called vibration serviceability issue. Since 1970s, researchers have proposed many human walking load models, and some of them have even been adopted by major design guidelines. Despite their wide applications in structural vibration serviceability problems, differences between these models in predicting structural responses are not clear. This paper collects 19 popular walking load models and compares their effects on structure?s responses when subjected to the human walking loads. Model parameters are first compared among all these models including orders of components, dynamic load factors, phase angles and function forms. The responses of a single-degree-of-freedom system with various natural frequencies to the 19 load models are then calculated and compared in terms of peak values and root mean square values. Case studies on simulated structures and an existing long-span floor are further presented. Comparisons between predicted responses, guideline requirements and field measurements are conducted. All the results demonstrate that the differences among all the models are significant, indicating that in a practical design, choosing a proper walking load model is crucial for the structure?s vibration serviceability assessment.

Stochastic finite element based seismic analysis of framed structures with open-storey

  • Manjuprasad, M.;Gopalakrishnan, S.;Rao, K. Balaji
    • Structural Engineering and Mechanics
    • /
    • 제15권4호
    • /
    • pp.381-394
    • /
    • 2003
  • While constructing multistorey buildings with reinforced concrete framed structures it is a common practice to provide parking space for vehicles at the ground floor level. This floor will generally consist of open frames without any infilled walls and is called an open-storey. From a post disaster damage survey carried out, it was noticed that during the January 26, 2001 Bhuj (Gujarat, India) earthquake, a large number of reinforced concrete framed buildings with open-storey at ground floor level, suffered extensive damage and in some cases catastrophic collapse. This has brought into sharp focus the need to carry out systematic studies on the seismic vulnerability of such buildings. Determination of vulnerability requires realistic structural response estimations taking into account the stochasticity in the loading and the system parameters. The stochastic finite element method can be effectively used to model the random fields while carrying out such studies. This paper presents the details of stochastic finite element analysis of a five-storey three-bay reinforced concrete framed structure with open-storey subjected to standard seismic excitation. In the present study, only the stochasticity in the system parameters is considered. The stochastic finite element method used for carrying out the analysis is based on perturbation technique. Each random field representing the stochastic geometry/material property is discretised into correlated random variables using spatial averaging technique. The uncertainties in geometry and material properties are modelled using the first two moments of the corresponding parameters. In evaluating the stochastic response, the cross-sectional area and Young' modulus are considered as independent random fields. To study the influence of correlation length of random fields, different correlation lengths are considered for random field discretisation. The spatial expectations and covariances for displacement response at any time instant are obtained as the output. The effect of open-storey is modelled by suitably considering the stiffness of infilled walls in the upper storey using cross bracing. In order to account for changes in soil conditions during strong motion earthquakes, both fixed and hinged supports are considered. The results of the stochastic finite element based seismic analysis of reinforced concrete framed structures reported in this paper demonstrate the importance of considering the effect of open-storey with appropriate support conditions to estimate the realistic response of buildings subjected to earthquakes.