• Title/Summary/Keyword: Floor Area Ratio Regulation

Search Result 15, Processing Time 0.031 seconds

Urban Tissue, Zoning and Achieved Floor Area Ratio (A-FAR) - Focused on Developed Floor Area Ratio (D-FAR) Compared to the Legal Floor Area Ratio (L-FAR) in Residential Area and Commercial Area in Seoul - (용적실현비(A-FAR)에 영향을 미치는 용도지역별 대지특성에 대한 분석 - 서울시 주거지역 및 상업지역에서 법정용적률(L-FAR) 대비 실현된 용적률(D-FAR)을 중심으로 -)

  • Kim, Soo Hyun;Choi, Chang Gyu
    • Journal of Korea Planning Association
    • /
    • v.54 no.2
    • /
    • pp.33-45
    • /
    • 2019
  • The Legal Floor Area Ratio (L-FAR) has been used as a major urban planning tool for efficient management of land use, landscape, and density. The Developed Floor Area Ratio (D-FAR) in each parcel is realized by such physical and institutional factors as urban tissue, local characteristics, and zoning with the L-FAR. The Achieved Floor Area Ratio (A-FAR), the ratio of the D-FAR to the L-FAR, is the relationship between realized density and the intended/desired outcomes of the regulations. The A-FAR informs the efficiency of L-FAR and its effect on parcels, and is an indicator of the demands of real estate developments under the zoning regulation. This study used detailed data of each parcel's characteristics, including parcel size, road width, and the number of roads bordered by a parcel, to identify the influencing factors on A-FAR. This analysis confirmed that the parcel size has a non-linear negative effect in the residential zone but a linear positive effect on A-FAR in the commercial zone. The width of the parcel's frontage in the commercial zone has a positive effect on the value, while in the residential zone the narrower width has higher A-FAR. In Seoul, the residential zone has higher A-FAR than the commercial zone, which means that the former has a relatively higher development pressure but a lower designated L-FAR. This result reflects that Seoul's residential zone absorbs the demand of commercial uses because of the significant permitting of mixed land use and has high-density residential buildings.

A Study on the Change of Architecture Density and Residential Environment according to Reconstruction (재건축에 따른 건축밀도 및 주거환경의 변화 연구)

  • Kim, Hong-Bae
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.19 no.1
    • /
    • pp.35-42
    • /
    • 2017
  • This study aims to investigate the change in building density and residential environment after the reconstruction of decrepit public rental housing complexes formed in accordance with the Land Readjustment Project during the 1970s-80s. The results of this study can be summarized as follows: First, in terms of change in residential environment after the reconstruction, floor plans that were limited to two to four types and to small apartments measuring $42.9m^2$(13py)-$56.1m^2$ (17py) became varied, presenting 5-6 types of floor plans and various sizes of apartments. In particular, the reconstructed apartments were mainly built in a size smaller than 85($m^2$) and in the 3LDK floor plan and staircase-style unit architectural structure in order to reflect the lifestyle of residents. Second, in terms of change in building density after the reconstruction, the building coverage ratio did not change a lot, but the floor area ratio showed great change depending on the complex, ranging from a minimum of 2.9 times (Singdong Complex) to a maximum of 5.4 times (Eoyangdong Complex). Such change is attributable to the reconstruction policy that aims to improve the residential environment for original residents, secure economic feasibility and efficiency, and reflect the lifestyle of residents while incorporating dividends assigned to the existing housing project members as well as the maximum floor area ratio allowed by the regulation. Additionally, in terms of change in the number of floors and building density after the reconstruction, the former 5-story apartments were changed to apartments with 16-28 stories. Accordingly, the number of households in each complex has also increased by 20%. Third, according to the characteristics of parking facilities in terms of the size and density of parking spaces, former apartment complexes had only aboveground parking lots, not underground parking area. The newly constructed apartment complexes have underground parking space, and the parking-housing ratio is 1.1-1.3 cars.

An Visual Density Index for the Housing Landscape Evaluation Focused on the Elevation Coverage Index (공동주택 경관평가를 위한 시각밀도 지표에 관한 연구 입면차폐도와 규제지침을 중심으로)

  • 강인호;이승미
    • Journal of the Korean housing association
    • /
    • v.15 no.3
    • /
    • pp.53-62
    • /
    • 2004
  • Recently the landscape of housing has been emphasized. This trend seems to reflect the negative aspects of housing landscape in urban area. Throughout the analysis on the various visual density index, the following findings were obtained; 1) Elevation blockage ratio(EBR) was permitted differently according to the types of housing blocks, and the preference of block layout was different to the location of site. 2) EBR regulation level was acceptable. But 40m level of general area should be stepped up to the 35m level. 3) The correlation between the floor area ratio(FAR) and the EBR was not high. Therefore it is reasonable to regulate the EBR to the location. 4) Elevation coverage ratio(ECR) was highly correlated with the FAR. It means that FAR can substitute for the ECR, and ECR should be regulated to the level of FAR.

An Analysis of the Policy Effect on the Change of Application Standard of Floor Area Ratio for Land Covering Two or More Zoning Area - Focused on Gangnam-gu - (둘 이상의 용도지역 등에 걸치는 대지에 대한 용적률 적용기준 변경의 정책적 효과분석 - 강남구를 중심으로 -)

  • Yu, Myeong-Han;Lee, Chang-Moo
    • Journal of Cadastre & Land InformatiX
    • /
    • v.48 no.2
    • /
    • pp.121-135
    • /
    • 2018
  • The ministry of land, Infrastructure and transport has revised the "National Land Planning and Utilization Act" in 2012. As a result, the regulation of floor area ratio for land covering two or more zoning area has been changed. This study conducted an analysis of the policy effects of changes in the criteria for the application of the floor area ratio by revising the "National Land Planning and Utilization Act". Land covering two or more zoning area means a street side commercial area and street side residential area that is generally understood. This study analyzed the policy effects in Gangnam-gu which has relatively large areas of street side commercial area and street side residential area. The 468 office building transaction cases were analyzed in Gangnam-gu from 2007 to 2017. The result shows that the office building, which has received incentive for policy changes, reported a 19.08% rise in price compared to the one that did not. It means that the economic effects of change of application standard were significant. The existing policy also served as a restriction on land use by landowners, which in turn contributed to the devaluation of the asset's intrinsic value. Therefore, this study may have contributed to the rational use of land and to provide an empirical basis for the change in policy to be assessed for its intrinsic value.

A Study on Present Condition and Adjustment of the Minmium Height Regulation District in Busan Metropolitan City (부산시 최저고도지구 실태 및 기준조정에 관한 연구)

  • Lee, Dong-Hyun;Baek, Tae-Kyung
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.11 no.2
    • /
    • pp.51-60
    • /
    • 2008
  • The Purpose of this study is to find the adjustment of the minimum height regulation district in Busan metropolitan city. For this purpose, data of buildings in the minimum height regulation district are collected and analysed. Especially, detailed data of buildings in CBD are analysed. The results of this study provide that CBD's average building height is the fourth floor and the ratio that a building less than the fourth floor holds in total building is 51%. In the case of central area, CBD's building height should be maintained and it is necessary to make the policy that reinforce limited height for the high land use and landscape management. Based on these findings this study suggests that the limit building height should put it up more than the seventh floor.

  • PDF

A Study on Management Plans through Case Analysis of Residential Complexes in Commercial Areas in Daejeon (대전시 상업지역 주거복합건축물 사례 분석을 통한 관리방안 연구)

  • Ryu, Kyungsoo
    • Journal of the Korean Regional Science Association
    • /
    • v.39 no.2
    • /
    • pp.63-76
    • /
    • 2023
  • Recently, due to the location of residential complexes in commercial areas of large cities, the urban function is shifting from commercial to residential.In order to improve the use volume system in the commercial area of Daejeon Metropolitan City, the system of special and metropolitan cities was compared and analyzed, and problems were derived by analyzing 8 cases. First, use classification of mixed-residential buildings, Second, unbalance of urban planning for functional loss of commercial area, Thrid, damage on urban environment due to difference of development density. Accordingly, improvement measures include First, securing the ratio of residential function and mixed use at least 10%, Second, securing urban competitiveness by inducing facilities that combine various uses and functions. The overall floor area ratio of housing is applied, Third, the development density is presented through the establishment of the district unit plan and consultation.

Establishment of the Measurement Model about the Adequate Urban Development Density using System Dynamics (시스템다이내믹스를 활용한 도시개발밀도의 적정성 평가 모델 구축 연구)

  • 전유신;문태훈
    • Proceedings of the Korean System Dynamics Society
    • /
    • 2003.08a
    • /
    • pp.1-24
    • /
    • 2003
  • The purpose of this paper was developing a development density control model for urban growth management, using system dynamics modeling. The density control model was developed to see how urban growth, transition, and decay occur depending on the interaction among population, houses, industry structure, land and urban infrastructure such as road, water supply, and sewage treatment facilities. Suggesting adequate level of development density control using the model was another purpose of this paper. The model was applied to An'yang city to estimate the maximum number of population, industry structures, houses, and cars that can be adequately sustained with the current An'yang city's infrastructur capacity. The computer simulation results shows that the city is overpopulated by some 90,000 people. To reduce the population to the adequate level that the current urban infrastructure can sustain, the current city regulation on floor area ratio are needed to be strengthened at least 20 to 35%.

  • PDF

An Analysis of Locational Factors to Affect Residential Improvement Projects in Busan Metropolitan City (부산의 주거정비사업 추진에 미치는 영향요인 분석)

  • Kim, Jung-Don;Oh, Se-Kyung;Lim, Jae-Moon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.1
    • /
    • pp.125-132
    • /
    • 2012
  • Busan metropolitan city faced with very low completion rate of residential environment improvement projects. Main reason is to designate proposed residential environment improvement areas without careful analysis of the possibilities of the improvement project completion. This study aims to clarify and analyze the phase characteristics of residential environment improvement process by using 12 variables representing 5 locational characteristics such as place factors, topological factors, size factors, location condition factors and regulation factors. From results of the analysis, this study finds that business floor area ratio, improvement type and site size affect significantly the completion rate of residential redevelopment projects. However, business floor ratio, improvement type, width of frontage road and slope are significant variables to affect the completion rate of residential rebuilding projects.

Study on Improvement Measures of Green Standard for Energy and Environmental Design for Expansion of Applying Green Roof - Focused on LEED in the USA and BREEAM in the UK - (옥상녹화 적용확대를 위한 녹색건축인증제도 개선방안 연구 - 미국 LEED 및 영국 BREEAM의 비교·분석을 중심으로 -)

  • Kim, Ji-Hyeon;Kwon, Hyuck-Sam;Kim, Jung-Gon;Lee, Bum-Sik
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.2
    • /
    • pp.75-82
    • /
    • 2018
  • Green roof in Korea has been recognized as part of landscape area and local governments enacted municipal ordinance for supporting green roof thereby assisting part of expenses spent for green roof within a range of budget for buildings which are eligible for the green roof support of existing buildings. However, it is necessary to enforce a regulation of mandatory green roof for new buildings in order to expand green roof application and provide a variety of assistances such as subsidy payment, tax relief, and mitigation of floor area ratio-related regulation as done in other advanced nations. In particular, LEED(Leadership in Environmental and Energy Design) in the USA applies additional point directly for green roof in terms of the reduction in heat island effects. For example, the following items are beneficial to have additional points: habitat preservation or restoration, external space, rainwater management, reduction in outdoor water usage, minimum energy performance, and optimum energy performance. In addition, the BREEAM(Building Research Establishment Environmental Assessment Method) in the UK specifies green roof as one of assessment items to be complied in terms of diversity of species. As such, LEED and BREEAM reflect direct and indirect effects of green roof on assessment criteria, which suggest a direction to green building certification criteria in Korea where only additional points are given for green roof according to soil depth.

Improvement of Small-size Multi-housing Area Reconstruction Project Using AHP Analysis (AHP분석을 통한 가로주택정비사업의 개선방안)

  • Kim, Suk-Joon;Lee, Sang-Ho;Huh, Young-Ki
    • Korean Journal of Construction Engineering and Management
    • /
    • v.20 no.2
    • /
    • pp.79-85
    • /
    • 2019
  • The policy introduced recently in order to promote small-size reconstruction housing projects for rehabilitating downtown area consists of aged multi houses has been little practiced, as preferential provisions for such projects are more likely applicable for large projects. Several expert interviews and surveys were conducted to find efficient clauses to overcome the problems and their relative weights. As the results, it is revealed that 'relation of floor area ratio' and 'relaxation of building height limit criteria' are the most effective whereas 'purchasing and operating of residents' common facilities with public fund' is little. The study results would be a great interests for public institutions to rebuild aged housing area without destroying local communities and to provide socially disadvantaged class with rental housing at the same time.