• Title/Summary/Keyword: Flexor pollicis longus Tendon

Search Result 5, Processing Time 0.02 seconds

Delayed Rupture of Flexor Pollicis Longus by Plate for Fracture of the Distal Radius (요골골절에 사용된 금속판에 의한 장무지 굴곡건의 지연성 파열)

  • Hwang, So-Min;Ahn, Sung-Min;Oh, Kyoung-Seok;Kim, Jin-Hyeong;Lee, Jun-Ho
    • Archives of Plastic Surgery
    • /
    • v.35 no.6
    • /
    • pp.751-754
    • /
    • 2008
  • Purpose: Delayed rupture of flexor pollicis longus as a sequelae of the plate inserted for distal radius fracture is a very rare. This is the first case reported and published in Korea. Methods: A 48 years old female patient visited hospital, complaining flexor disturbance of interphalangeal joint of left thumb, which suddenly occurred without any external wound. We found that she had received operation of fixing plate for fracture of left distal radius 10 years ago. As operational opinion, we have checked that flexor pollicis longus tendon has been ruptured with oblique ways being stimulated by extended plate to palmar side over long period. Results: Authors performed tenorrhaphy of flexor pollicis longus without tendon graft and presented a successful active flexion of the left thumb interphalangeal joint 1 year after the operation. Conclusion: If the extruded part of the end plate is observed during the operation or follow-up, it is considered to be necessary to get rid of the plate as early as possible after the fracture healing.

An accessory muscle of flexor digitorum profundus with bipennate first lumbrical: a unique variation of clinical significance

  • Rohini Motwani;Ariyanachi Kaliappan;Mrudula Chandrupatla
    • Anatomy and Cell Biology
    • /
    • v.56 no.1
    • /
    • pp.150-154
    • /
    • 2023
  • During the deep dissection of the front of the forearm, an anomalous accessory muscle in relation to the flexor digitorum profundus (FDP) muscle was observed in the right forearm. The accessory muscle consisted of a spindle-shaped muscle belly with a long tendon underneath the flexor pollicis longus muscle. When followed distally, the accessory muscle tendon was found lateral to the FDP tendon for the index finger and entered the palm deep to the flexor retinaculum. In the palm, we encountered the first lumbrical muscle as a bipennate muscle taking origin from the adjacent sides of the middle of the tendons of FDP and accessory muscle tendon. After giving origin to first lumbrical muscle, the accessory muscle got merged with the tendon of FDP for index finger. Understanding this kind of variation is required for radiologists and hand surgeons for diagnostic purposes and while performing corrective surgical procedures.

Pollicization of the Middle Finger

  • Bahk, Sujin;Eo, Su Rak;Cho, Sang Hun;Jones, Neil Ford
    • Archives of Reconstructive Microsurgery
    • /
    • v.24 no.2
    • /
    • pp.62-67
    • /
    • 2015
  • Purpose: Pollicization typically involves surgical migration of the index finger to the position of the thumb. This procedure facilitates the conversion of a useless hand into a well-functioning one in patients who are not amenable to the toe-to-hand transfer. However, middle finger pollicization has been rarely reported. Materials and Methods: We reconstructed a thumb by immediate pollicization of the remnants of the middle finger in two patients who sustained a tumor and a trauma, respectively. The former, after cancer ablation was performed, has not been reported literally, and the latter involved free devitalized pollicization of the middle finger using a microsurgical anastomosis. The distal third extensor communis tendon was sutured to the proximal extensor pollicis longus tendon and the distal flexor digitorum superficialis and profundus were sutured to the proximal flexor pollicis longus. The abductor pollicis brevis tendon was sutured to the distal end of the first palmar interosseous muscle. Coaptation of the third digital nerve and the superficial radial nerve branch was performed. Results: Patients showed uneventful postoperative courses without complication such as infection or finger necrosis. Based on the principles of pollicization, a wide range of pinch and grasp movements was successfully restored. They were pleased with the functional and cosmetic results. Conclusion: Although the index finger has been the digit of choice for pollicization, we could also use the middle finger on specific occasions. This procedure provides an excellent option for the reconstruction of a mutilated thumb and could be performed advantageously in a single step.

Study on the Anatomical Pericardium Meridian Muscle in Human (수궐음 심포경근의 해부학적 고찰)

  • Park, Kyoung-Sik
    • Korean Journal of Acupuncture
    • /
    • v.22 no.1
    • /
    • pp.67-74
    • /
    • 2005
  • Objectives : This study was carried to identify the component of the Pericardium Meridian Muscle in human. Methods : The regional muscle group was divided into outer, middle, and inner layer. The inner part of body surface were opened widely to demonstrate muscles, nerve, blood vessels and to expose the inner structure of the Pericardium Meridian Muscle in the order of layers. Results We obtained the results as follows; He Perfcardium Meridian Muscle composed of the muscles, nerves and blood vessels. In human anatomy, it is present the difference between terms (that is, nerves or blood vessels which control the muscle of the Pericardium Meridian Muscle and those which pass near by the Pericardium Meridian Muscle). The inner composition of the Pericardium Meridian Muscle in human is as follows ; 1) Muscle P-1 : pectoralis major and minor muscles, intercostalis muscle(m.) P-2 : space between biceps brachialis m. heads. P-3 : tendon of biceps brachialis and brachialis m. P-4 : space between flexor carpi radialis m. and palmaris longus m. tendon(tend.), flexor digitorum superficialis m., flexor digitorum profundus m. P-5 : space between flexor carpi radialis m. tend. and palmaris longus m. tend., flexor digitorum superficialis m., flexor digitorum profundus m. tend. P-6 : space between flexor carpi radialis m. tend. and palmaris longus m. tend., flexor digitorum profundus m. tend., pronator quadratus m. H-7 : palmar carpal ligament, flexor retinaculum, radiad of flexor digitorum superficialis m. tend., ulnad of flexor pollicis longus tend. radiad of flexor digitorum profundus m. tend. H-8 : palmar carpal ligament, space between flexor digitorum superficialis m. tends., adductor follicis n., palmar interosseous m. H-9 : radiad of extensor tend. insertion. 2) Blood vessel P-1 : lateral cutaneous branch of 4th. intercostal artery, pectoral br. of Ihoracoacrornial art., 4th. intercostal artery(art) P-3 : intermediate basilic vein(v.), brachial art. P4 : intermediate antebrachial v., anterior interosseous art. P-5 : intermediate antebrarhial v., anterior interosseous art. P-6 : intermediate antebrachial v., anterior interosseous art. P-7 : intermediate antebrachial v., palmar carpal br. of radial art., anterior interosseous art. P-8 : superficial palmar arterial arch, palmar metacarpal art. P-9 : dorsal br. of palmar digital art. 3) Nerve P-1 : lateral cutaneous branch of 4th. intercostal nerve, medial pectoral nerve, 4th. intercostal nerve(n.) P-2 : lateral antebrachial cutaneous n. P-3 : medial antebrachial cutaneous n., median n. musrulocutaneous n. P-4 : medial antebrachial cutaneous n., anterior interosseous n. median n. P-5 : median n., anterior interosseous n. P-6 : median n., anterior interosseous n. P-7 : palmar br. of median n., median n., anterior interosseous n. P-8 : palmar br. of median n., palmar digital br. of median n., br. of median n., deep br. of ulnar n. P-9 : dorsal br. of palmar digital branch of median n. Conclusions : This study shows some differences from already established study on meridian Muscle.

  • PDF

The Clinical usefulness of the tangential projection view of Radius groove after Distal Radius Fracture operation using the T-type Plat (전방 잠금형 금속판을 이용한 요골 원위부 골절수술 후 요골구 접선방향 촬영법의 임상적 유용성)

  • Seo, Sun-Youl;Cho, Jeong-Hee;Han, Man-Seok;Kim, Tae-Hyung;Yoo, Se-Jong;Kim, Yong-Kyun;Han, Dong-Kyoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.6
    • /
    • pp.2760-2766
    • /
    • 2013
  • Introduction : The projection method to check existence and nonexistence of radius groove penetration of screw after distal radius fracture operation clinical using the T-type plate and the radiation of radial groove tangential is to propose a new test. Material and Methods : On the tangential projection view of radius groove, elevation angle of distal radius is 2.5, 5, 7.5, 10 degree. and forearm and radiation detector of angle is 60, 70, 80, degree each changed. that analyzed check existence and nonexistence of radius groove penetration of screw. Results : For the image of Radial groove tangential. the case of not radius groove penetration of screw(63.95%, n=55), medial penetration of radius groove(10.47%, n=9) or lateral penetration of radius groove(25.58%, n=22) was analysis. The radius groove penetrating of screw length was a range of 0.43 ~ 2.72mm, the average was 1.06mm. the check existence and nonexistence of radius groove penetration of medial or lateral was analysis that it accurate for the image of Radial groove tangential. the radiography of radial groove is well described elevation angle of distal radius 2.5 to 7.5 degree(90% over), forearm and radiation detector of angle 70degree(80%over) Conclusion : It is elevation angle of distal radius is 5degree, forearm and radiation detector of angle 70degree recommended.