A thirty-month-old male Moluccan Cockatoo (Cacatua moluccansis) with mild anorexia was referred. Through physical examination, fireign body was palpated at the crop region. Radiopaque, lineal foreign body was visualized on the lateral radiographs of the thoracic esophageal region. The patient was definitively diagnosed esophageal foreign body which is ingested feeding tube. The foreign body removal was undertaken using a flexible endoscope and a grasping forcep without any other complications. This case report demonstrated that successful esophageal foreign body removal with endoscopy in birds.
Purpose: The aim of our study was to establish a safe and convenient diagnostic method for acute gastrointestinal (GI) graft-versus-host disease (GVHD) in children by determining the sensitivity and negative predictive values of upper and lower endoscopic biopsies for children suspected of GI GVHD. Methods: Patients suspected of GI GVHD who received endoscopic evaluation within 100 days after stem cell transplantation and endoscopies between January 2012 and March 2014 in Seoul National University Children's Hospital were included in our study. Results: Fifteen patients with a total of 20 endoscopic procedures were included in our study. Sensitivity at the esophagus, stomach, and duodenum were 22.2%, 30.0%, and 80.0%, respectively. Negative predictive values at the esophagus, stomach, and duodenum were 22.2%, 30.0%, and 60.0%, respectively. Overall sensitivity and negative predictive values of upper endoscopic biopsy for GVHD were 77.8% and 50.0%, respectively. Overall sensitivity and negative predictive values of lower endoscopic biopsy for GVHD were 88.9% and 66.7%, respectively. Conclusion: We recommend flexible sigmoidoscopy as a safe and accurate diagnostic tool for GVHD, similar to other studies reported previously. However, if there is no evidence of GVHD on sigmoidoscopy with high index of suspicion of GI bleeding, full colonoscopy and upper endoscopy should be considered.
Foreign body (FB) ingestion of children is a common pediatric emergency requiring medical attention. Pediatric emergency physicians and gastroenterologists often encounter nervous and distressed situations, because of children presenting with this condition in the common clinical practice. When determining the appropriate timing and indications for intervention, physicians should consider multiple patient- and FB-related factors. The utilization of a flexible endoscopy is considered safe and effective to use in these cases, with a high success rate, for the effective extraction of FBs from the gastrointestinal tract of a child. Additionally, a Foley catheter and a magnet-attached Levin tube have been used for decades in the case of FB removal. Although their use has decreased significantly in recent times, these instruments continue to be used for several indications. Using a Foley catheter for this purpose does not require special training and does not necessarily require sedation of the patient or fluoroscopy, which serve as advantages of utilizing this method for foreign object retrieval. An ingested magnet or iron-containing FB can be retrieved using a magnet-attached tube, and can be effective to retrieve an object from any section of the upper gastrointestinal tract that can be reached. Simple and inexpensive devices such as Foley catheters and magnetattached tubes can be used in emergencies such as with the esophageal impaction of disk batteries if endoscopy cannot be performed immediately (e.g., in rural areas and/or in patients presenting at midnight in a facility, especially in those without access to endoscopes or emergency services, or in any situation that warrants urgent removal of a foreign object).
Purpose: There have been a few data about esophageal length in children and previous data are improper for application to various procedures. Because of the variability in height and weight of each the individuals especially in children, measurable external parameters are needed. Methods: We measured distance from upper incisor to esophago-gastric junction using a flexible endoscope and compared these data with age, height and weight in 262 children who underwent upper gastrointestinal endoscopy. Results: The mean age was $9.0{\pm}3.6year$ (from 2 days to 16 year of age), mean height was $132.89{\pm}23.49cm$ and mean length from upper incisor to esophago-gastric junction was $33.34{\pm}5.42cm$. Correlation between distance from upper incisor to esophago-gastric junction and height was the mostly predictable indicator of the esophageal length (Pearson correlation=0.944). We propose a formula [Esophageal length=4.419+($0.218{\times}height$)] as a indicator of the esophageal length (p=0.000, $R^2=0.891$). Conclusion: The esophageal length in children and for application to various procedures can be reliably predicted by using the height.
OBJECTIVE : To study the management (diagnostic and therapeutic) of esophageal foreign bodies with rigid esophagoscopy. MATERIAL AND METHODS : All 100 patients admitted to the Dankook University Hospital for ingestion of foreign bodies between May 1994 and July 1999. The outcome for each patient was determined by examining hospital records of demographic information, identification of the foreign body and the removal procedure used. RESULTS : Rigid esophagoscopy was performed for suspected foreign bodies in 100 cases an impacted. The most frequent location was the upper third of the esophagus (68%). The most common type of foreign body was fish bones in adult(61%) and coins in children(70%). In 12 patients. flexible endoscopy had failed previously to remove the foreign body and 4 cases were migrated esophageal metal stent in esophageal stenosis. CONCLUSIONS : The rigid esophagoscopy is appropriate techniques for managing esophageal foreign bodies.
This BEF will be resolved with tissue adhesive application The bronchoesophageal fistula[BEF] is a rare lesion in thoracic surgical diseases & is difficult to be closed surgically. Tissue adhesives has been used widely in surgical fields, or in endoscopy, for some time and seems to be potentially useful in cardiothoracic surgery. We have experienced the closure of BEF with tissue adhesive Tisseel in 2 cases recently. One is 60 years old male who had taken the closure of BEF with Tisseel through right bronchotomy. The other is 57 years old female who had taken the closure of BEF with Tisseel with flexible gastrofiberscopy. The postoperative courses are uneventful for 4 months to now.
Unintentional foreign body ingestion is common in children, and coins are the most common foreign body ingested. Foreign body remaining in the esophagus may be associated with mucosal ulceration or esophageal obstruction and can potentially lead to significant morbidity and even death. Removal of esophageal foreign body is therefore generally recommended. Several methods are utilized including esophagoscopy in operating room, flexible endoscopy in out patient setting, fluoroscopic Foley catheter technique, and advancement using bougienage. We report two cases of esophageal foreign body(paduk stone) which were hard to be removed by usual esophagoscopic removal. Successful removal was accomplished with the aid of Fogarty catheter under the general anesthesia.
Lee, John Jae Woon;Cho, Wan Seok;Lee, Dong Hoon;Yoon, Tae Mi
Korean Journal of Head & Neck Oncology
/
v.30
no.1
/
pp.28-30
/
2014
Foreign bodies in upper aerodigestive tract migrating into retropharyngeal space are rarely encountered emergent cases in otolaryngologic fields. A 60-years-old female presented throat pain and lump sense after a meal. Computer tomography showed metallic foreign body impacted in the retropharyngeal space. A hypopharyngeal perforation was suspected by through flexible laryngoscopy and gastrointestinal endoscopy. It was successfully removed by external cervical approach, and we report this case with a review of the related literatures.
A 5-year-old, intact female, Pomeranian was presented with a persistent vomiting for 5 days after swallowing a chicken bone. The dog was diagnosed with an esophageal foreign body, and a small perforation was found after the endoscopic removal of the chicken bone. The dog was determined to be treated with a non-operative management, and a complete closure of the perforation was confirmed by a flexible endoscopy 3 weeks after removal of a chicken bone. This paper reports the case of esophageal perforation caused by foreign body in esophagus managed with the non-operative therapy instead of surgical correction.
The majority of esophageal Foreign body ingestions occur in the pediatric population. In adults, true foreign object ingestion occurs more commonly among those with psychiatric disorders, mental impairment. The management of esophageal foreign bodies is influenced by the age, clinical condition of ingested material, anatomic location and technical abilities of the endoscopist. Recently the therapeutic endoscopy is becoming wider and more rational in application. We evaluated the role of endoscopy for removal of esophageal foreign bodies during the period of 4 years from January 2000 to December 2003 at the Department of Otolaryngology and Gastroenterology, Seonam University Hospital. The results were as follow, 1) The age ranged from 21 to 74 years old (mean 50.5), most frequent age group was between 61-70 years old and male to female ratio was 1:1.4. 2) Fish bone was the most frequent foreign body in the esophagus ($47.1\%$), food material ($23.5\%$) and meats ($17.6\%$) were next frequent foreign bodies. The most frequent site of lodgement was the first ($78.4\%$), second ($17.6\%$) and third narrowing ($3.9\%$) in order. 3) The most common symptom was foreign body sensation (28.6%). the next common symptoms were chest discomfort($23.8\%$) and dysphagia($19\%$). 4) In duration of lodgement, 49cases ($96.1\%$) were lodged for less than one day. 5) The foreign bodies of esophagus were removed successfully by flexible endoscope with basket, snare, forceps, overtube and endoscopic variceal ligation cap. There were only 3 cases of minimal complications, esophageal mucosal tearing. In conclusion, endoscopic esophageal foreign body removal is useful and safe with minimal or no complications.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.