• Title/Summary/Keyword: Flexible endoscopy

Search Result 23, Processing Time 0.031 seconds

Complications of Tracheotomy cannula and its prevention (기관 캐눌러에 의한 합병증과 예방법)

  • 손진호;강지원;이현석;전병규;신승헌;박재율;안욱수
    • Korean Journal of Bronchoesophagology
    • /
    • v.4 no.1
    • /
    • pp.35-42
    • /
    • 1998
  • The complications of a tracheotomy are caused by inappropriate surgical techniques, unsuitable cannula selections, and improper wound care. Among these, the solutions to problems of surgical technique and wound care have been reported in many articles. Detailed methods for preventing complications by the cannula are rare. The authors tried to find a way of preventing complications by the cannula Materials and Methods : The authors analized complications in 70 patients who had a temporary tracheotomy and were wearing a cannula. And the complications were compared between 4 commercial cannulas used in our institute. The examination methods used were a simple neck lateral radiogram and flexible endoscopy. Results: The order of most commonly found complications were as followed; at the suprastoma, end of cannula, level of tracheotomy, and infrastoma. Among 4 cannulas, a particular product had so many complications compared to the other 3 cannulas. The most common cause of complications was unsuitable cannula. All complications were cured with no sequelae. Flexible endoscopy is far superior to radiologic exam for detecting tracheal complications. Conclusion: Flexible endoscopy through the tracheostoma is very helpful for detecting complications early and determining if a proper cannula is used, which can prevent further complications such as stenosis or innominate artery rupture. The authors, therfore, recommend using the flexible endoscopy to all patients wearing tracheotomy tubes. Some complications can simply be prevented by replacing the one to another cannula properly fit for the individual patients. Various cannulas should be prepared at the hospital because the tracheal curvature and distance of skin to trachea are individualized.

  • PDF

A Review of Endoscopic Removal Methods in 127 Cases of the Esophageal Foreign Bodies (소아 식도 이물의 내시경적 적출방법 변화에 대한 고찰)

  • Kim, Jum Su;Yang, Jung Soo;Jung, Hae Sung;Lee, Min Hye;Park, Chan-Hoo;Choi, Myoung Bum;Woo, Hyang-Ok;Youn, Hee-Shang
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.4
    • /
    • pp.459-465
    • /
    • 2002
  • Purpose : The aim of this study was to evaluate the latest tendency of esophageal foreign body's extraction and to obtain a consensus from recent trends of indications and techniques of flexible endoscopy of esophageal FB in children. Methods : We retrospectively reviewed medical records of 127 cases with foreign bodies in esophagus at Dept. of Pediatrics and Otorhinolaryngology, Gyeongsang National University Hospital (GNUH) from Jun, 1987 to July, 2001. They were divided into two groups by the kinds of endoscopy : flexible endoscope(66 cases) or rigid endoscope(61 cases). Rigid endoscopy was performed under general anesthesia at Dept. of Otorhinolaryngology but flexible endoscopy was performed without general anesthesia or sedative drugs(midazolam or diazepam). Results : An annual number of cases of two groups were similar from 1991 to 1998. But from 1999, flexible endoscopy was performed actively. Asymptomatic cases were frequently observed in flexible endoscopy(28 cases/66 cases) but swallowing difficulties were frequently observed in the rigid endoscopy group(25 cases/61 cases). Other symptoms were vomiting, irritability, chest discomfort and abdominal pain. The total number of cases with underlying disease(esophageal stenosis, cerebral palsy) was 8. The total number of cases with complications (erosion, ulcer, bleeding, perforation) was 11. The above cases were not correlated between the two groups. In 55 cases(83.3%) of the flexible endoscopic group and 53 cases(86.8%) of the rigid endoscopic group, foreign bodies in the esophagus were removed within 24 hours. Conclusion : We could not find any benefit in rigid endoscopic technique. Flexible endoscopic FB removal can be performed safely and effectively in children by an experienced endoscopist.

New Diagnostic Techniques in Cancer of the Pharynx and Esophagus (인두암과 식도암의 새로운 진단내시경)

  • Cho, Joo Young;Cho, Won Young
    • Korean Journal of Bronchoesophagology
    • /
    • v.17 no.1
    • /
    • pp.14-18
    • /
    • 2011
  • The diagnosis and treatment of early gastrointestinal cancers is the gastroenterologists' mission because of national cancer screening program in South Korea. The detection of early cancers is emphasized, because these were previously treated with surgical treatment can be currently cured with endoscopic treatment. Gastroenterologists who achieved at least on some level can make an exact diagnosis regardless of what type of endoscopy, but generally, there are some required conditions for an optimal diagnosis. First, clinically important lesions have to be detected easily. Second, the border and morphology of lesions have to be characterized easily. Third, lesions have to be diagnosed exactly. Precancers and early cancers are often subtle and can pose a challenge to gastroenterologists to visualize using standard white light endoscopy. The use of dye solutions aids the diagnosis of early gastrointestinal cancers, however, it is a quite cumbersome to use dye solutions all the time and the solution often bothers the exact observation by pooling into the depression or ulceration of the lesion. To overcome this weakness, newer endoscopes are now developed so called "image enhanced endoscopy" using optical and/or electronic methods such as narrow band imaging (NBI), autofluorescence imaging (AFI), i-scan, flexible spectral imaging color enhancement (FICE) and confocal endomicroscopy (CLE).

  • PDF

Robotics for Advanced Therapeutic Colonoscopy

  • Wong, Jennie YY;Ho, Khek Yu
    • Clinical Endoscopy
    • /
    • v.51 no.6
    • /
    • pp.552-557
    • /
    • 2018
  • Although colonoscopy was originally a diagnostic imaging procedure, it has now expanded to include an increasing range of therapeutic interventions. These procedures require precise maneuvers of instruments, execution of force, efficient transmission of force from the operator to the point of application, and sufficient dexterity in the mobilization of endoscopic surgical instruments. The conventional endoscope is not designed to support technically demanding endoscopic procedures. In case of colonoscopy, the tortuous anatomy of the colon makes inserting, moving, and orientating the endoscope difficult. Exerting excessive pressure can cause looping of the endoscope, pain to the patient, and even perforation of the colon. To mitigate the technical constraints, numerous technically enhanced systems have been developed to enable better control of instruments and precise delivery of force in the execution of surgical tasks such as apposing, grasping, traction, counter-traction, and cutting of tissues. Among the recent developments are highly dexterous robotic master and slave systems, computer-assisted or robotically enhanced conventional endoscopes, and autonomously driven locomotion devices that can effortlessly traverse the colon. Developments in endoscopic instrumentations have overcome technical barriers and opened new horizons for further advancements in therapeutic interventions. This review describes examples of some of these systems in the context of their applications to advanced therapeutic colonoscopy.

Reconstruction of esophageal stenosis that had persisted for 40 years using a free jejunal patch graft with virtual endoscopy assistance

  • Fujisawa, Daisuke;Asato, Hirotaka;Tanaka, Katsunori;Itokazu, Tetsuo;Kojya, Shizuo
    • Archives of Plastic Surgery
    • /
    • v.47 no.2
    • /
    • pp.178-181
    • /
    • 2020
  • In this report, we present a case in which good results were achieved by treatment using a free jejunal patch graft with virtual endoscopy (VE) assistance in a patient whose swallowing had failed to improve for 40 years after he mistakenly swallowed sulfuric acid, despite pectoralis major myocutaneous flap grafting and frequent balloon dilatation surgery. During the last 20 years, virtual computed tomography imaging has improved remarkably and continues to be used to address new challenges. For reconstructive surgeons, the greatest advantage of VE is that it is a noninvasive modality capable of visualizing areas inaccessible to a flexible endoscope. Using VE findings, we were able to visualize the 3-dimensional shape beyond the stenosis. VE can also help predict the area of the defect after contracture release.

Alternative Treatment of Osteoma Using an Endoscopic Holmium-YAG Laser

  • Han, Ba Leun;Shin, Ho Seong
    • Archives of Plastic Surgery
    • /
    • v.39 no.4
    • /
    • pp.422-425
    • /
    • 2012
  • Osteoma is one of the most common tumors of the cranial vault and the facial skeleton. For osteoma in the facial region, endoscopic resection is widely used to prevent surgical scarring. Tumors in a total of 14 patients were resected using an endoscopic holmium-doped yttrium aluminium garnet (Ho:YAG) laser with a long flexible fiber. Aside from having the advantage of not leaving a scar due to the use of endoscopy, this procedure allowed resection at any position, was minimally invasive, and caused less postoperative pain. This method yielded excellent cosmetic results, so the endoscopic Ho:YAG laser is expected to emerge as a good treatment option for osteoma.

Gastrointestinal Foreign Bodies in Children -Experiences of 60 Cases in Kangwon, Korea- (소아 위장관 이물 -강원지역 소아 60례-)

  • Lee, Young-Sub;Kang, Kae-Wool;Choi, Won-Kyu
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.4 no.2
    • /
    • pp.148-154
    • /
    • 2001
  • Purpose: Ingested foreign bodies present a common clinical problem. It is well known that most of them pass uninterrupted through the gastrointestinal tract. We evaluated the role of endoscopy and Foley catheter for removal of foreign bodies in the gastrointestinal tract. Methods: We investigated retrospectively 60 cases with foreign bodies in the gastrointestinal tract. They had been treated at Wonju Christian Hospital, Yonsei University of Korea, from January, 1996 through December, 1999. Results: The age of the patients ranged from 7 months to 13 years. Patients under 5 years were 57 cases (97%) and there was no significant difference in sex (M : F=1.07 : 1). 45 cases of the patients had no symptom. The most common foreign bodies were coins (43 cases). The most common location was esophagus (31 cases). The number of foreign body removal using flexible endoscopy and Foley catheter was 22 (36.7%) and 18 (30.0%) cases, respectively. In 18 cases (30.0%), foreign bodies passed spontaneously. Only 1 case (1.7%), curtain pin impaction at ileocecal region, required surgery. Conclusion: Early foreign body removal from esophagus and stomach is recommended to lessen the morbidity and complication. Fluoroscopic foley catheter technique and flexible endoscopy for removal of esophageal foreign bodies in children is safe and effective.

  • PDF

FHD Flexible Endoscopy Design Using Wedge Prism (Wedge Prism을 이용한 FHD급 연성 내시경 광학계 설계)

  • Park, Sung-Woo;Jung, Mee-Suk
    • Korean Journal of Optics and Photonics
    • /
    • v.33 no.6
    • /
    • pp.295-302
    • /
    • 2022
  • In this paper, a wedge prism application method was studied to design a full-high-definition (FHD)-class high-resolution flexible endoscope. In the case of the conventional flexible endoscope optical system, the F number is made large or a liquid lens is applied to obtain the same imaging performance in a wide depth of field. However, there is a problem in that the diameter of the optical system increases because an additional light guide and equipment are required. To solve this problem, two wedge prisms were applied to the flexible endoscope optical system to adjust the image distance for each object distance. First, two wedge prisms were symmetrically placed on the designed endoscopic optical system. An image distance satisfying the target imaging performance according to each objective distance was derived. Next, the wedge prism decenter value for controlling the image distance was derived. By combining these two data, a wedge prism decenter value that satisfied the target imaging performance at each object distance was applied in multi configurations. As a result of the optimal design applied with the wedge prism, a target imaging performance of more than 20% of the modulation transfer function for a resolution of 178 cycles/mm was satisfied in the entire depth of field of 100 mm-7 mm.

Endoscopic Removal of Esophageal Foreign Body in a Moluccan Cockatoo (Cacatua moluccensis) (몰루칸 앵무새에서의 내시경을 이용한 식도 이물 제거 일례)

  • Lee, So-Young;Yoo, Jong-Hyun;Park, Chul;Park, Hee-Myung
    • Journal of Veterinary Clinics
    • /
    • v.24 no.1
    • /
    • pp.29-31
    • /
    • 2007
  • A thirty-month-old male Moluccan Cockatoo (Cacatua moluccansis) with mild anorexia was referred. Through physical examination, fireign body was palpated at the crop region. Radiopaque, lineal foreign body was visualized on the lateral radiographs of the thoracic esophageal region. The patient was definitively diagnosed esophageal foreign body which is ingested feeding tube. The foreign body removal was undertaken using a flexible endoscope and a grasping forcep without any other complications. This case report demonstrated that successful esophageal foreign body removal with endoscopy in birds.

Stepwise Endoscopy Based on Sigmoidoscopy in Evaluating Pediatric Graft-versus-Host Disease

  • Lee, Kyung Jae;Choi, Shin Jie;Yang, Hye Ran;Chang, Ju Yuong;Kang, Hyoung Jin;Shin, Hee Young;Kang, Gyeong Hoon;Ko, Jae Sung;Moon, Jin Soo
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.19 no.1
    • /
    • pp.29-37
    • /
    • 2016
  • Purpose: The aim of our study was to establish a safe and convenient diagnostic method for acute gastrointestinal (GI) graft-versus-host disease (GVHD) in children by determining the sensitivity and negative predictive values of upper and lower endoscopic biopsies for children suspected of GI GVHD. Methods: Patients suspected of GI GVHD who received endoscopic evaluation within 100 days after stem cell transplantation and endoscopies between January 2012 and March 2014 in Seoul National University Children's Hospital were included in our study. Results: Fifteen patients with a total of 20 endoscopic procedures were included in our study. Sensitivity at the esophagus, stomach, and duodenum were 22.2%, 30.0%, and 80.0%, respectively. Negative predictive values at the esophagus, stomach, and duodenum were 22.2%, 30.0%, and 60.0%, respectively. Overall sensitivity and negative predictive values of upper endoscopic biopsy for GVHD were 77.8% and 50.0%, respectively. Overall sensitivity and negative predictive values of lower endoscopic biopsy for GVHD were 88.9% and 66.7%, respectively. Conclusion: We recommend flexible sigmoidoscopy as a safe and accurate diagnostic tool for GVHD, similar to other studies reported previously. However, if there is no evidence of GVHD on sigmoidoscopy with high index of suspicion of GI bleeding, full colonoscopy and upper endoscopy should be considered.