• Title/Summary/Keyword: Flexible Wall

Search Result 206, Processing Time 0.023 seconds

A Study of Dynamic Response in a Pipeline for Design of Hydraulic Circut (유압회로 설계를위한 유압관로에서의 동특성연구)

  • Kim, Ji-Hwan;Kim, Kwang-Ho;Shin, You-Hwan;You, Young-Tae
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.2024-2030
    • /
    • 2003
  • Design for a quite operation of fluid power system requires the understanding of noise and vibration characteristics of the system. This paper presents a dynamic response for design of hydraulic circuit. Experimental investigations on the attenuation characteristics of pressure ripple in automotive power steering hydraulic pipe with dynamic response of hydraulic pipe line is examined. Also, a mathematical model of hydraulic pipe is proposed to support design of the hydraulic circuit and analyze the attenuation characteristics of pressure ripples in a hydraulic pipe line. And analyze the impedance characteristics to determine the postion to construct accumulator for attenuation the pressure pulsation. The experimental results show that the pulsation attenuation characteristics of hydraulic hoses is remarkably affected by the flexible metal tube inserted coaxially inside a hydraulic hose with a finite length as well as viscoelastic properties of hose wall. It is also shown that the predicted results by the model proposed here agree well with the measured results over a wied range of frequency;

  • PDF

Rigid Bronchoscopic Treatment for an Adult Case of Multiple Squamous Papillomatosis in the Trachea (성인에서 발생한 다발성 기관 유두종증에 대한 경직성 기관지경을 이용한 치험 1 예)

  • Jung, Bock-Hyun;Lim, Jae-Min;Kim, Mi-Hye
    • Korean Journal of Bronchoesophagology
    • /
    • v.15 no.2
    • /
    • pp.81-86
    • /
    • 2009
  • A 57 year old human immune virus(HIV)-positive male presented with a progressive dyspnea for 6 months. Chest CT showed multiple polypoid masses arising from upper tracheal wall. Bronchoscopic examination revealed that multiple large cauliflower-like polypoid tumors was obstructing tracheal lumen. They were diagnosed as multiple squamous papillomas and were removed by Nd:YAG laser photocoagulation and rigid bronchoscopic treatment. The tumors were histologically diagnosed as squamous papilloma infected with human papilloma virus(HPV) type 6 and 11 in in-situ hybridization. Rigid bronchoscopy might be safer and more efficient than flexible bronchoscopy for the treatment of multiple tracheal papillomatosis obstructing tracheal lumen because of easy establishment of airway patency and direct use of rigid bronchoscope itself for tumor resection.

  • PDF

Compressibility and hydraulic conductivity of calcium bentonite treated with pH-responsive polymer

  • Choo, Hyunwook;Choi, Youngmin;Kim, Young-Uk;Lee, Woojin;Lee, Changho
    • Geomechanics and Engineering
    • /
    • v.22 no.4
    • /
    • pp.329-337
    • /
    • 2020
  • Polyacrylamide (PAM) possesses high water absorption capacity and a unique pH-dependent behavior that confer large potential to enhance the engineering performance of clays. In this study, calcium bentonite was treated with a nonionic PAM. Flexible-wall permeability test and the consolidation test were performed at different pH values to evaluate the effects of PAM treatment on the hydraulic and consolidation properties. Test results demonstrate that index properties are affected by the adsorbed PAM on clay surface: a decrease in specific gravity, a decrease in net zeta potential, and an increase in liquid limit are observed due to the PAM treatment. At a given pH, the compressibility of the treated clay is greater than that of the untreated clay. However, the compression indices of untreated and treated clays can be expressed as a single function of the initial void ratio, regardless of pH. Hydraulic conductivity is reduced by PAM treatment about 5 times at both neutral and alkaline pH conditions under similar void ratios, because of the reduction in size of the water flow channel by PAM expansion. However, at acidic pH, the hydraulic conductivity of the treated clay is slightly higher than the untreated clay. This reflects that the treated bentonite with PAM can be beneficially used in barrier system for highly alkaline residues.

Measurement of Flow Field Downstream of Polyurethane Artificial Heart Valve with Floating Valve Leaflet (열림판이 지지대에 고정되지 않은 폴리우레탄 인공판막 하류의 유동장 측정)

  • Kim, J.K.;Sung, J.;Chang, J.K.;Min, B.G.;Yoo, J.Y.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.247-248
    • /
    • 1998
  • The effect of unattached valve leaflet on flow field downstream of a floating and flapping polyurethane heart valve prosthesis was investigated. With a triggering system and a time-delay circuit the instantaneous velocity field downstream of the valve was measured by particle image velocimetry (PIV) in conjunction with the opening posture of a flexible valve leaflet during a cardiac cycle. Reynolds shear stress distribution was calculated from the velocity fields and wall shear stress was directly measured by hot-film anemometry (HFA). The floating motion of the valve leaflet resulted in the reduction of pressure drop and recirculating flow region downstream of the valve.

  • PDF

System Development of Removing Dust and Odor from Manufacturing Process of FRP Products (FRP제품 가공시 발생하는 분진 및 악취 제거 시스템 개발)

  • Yun, Huy Kwan;Kim, Jae Yong
    • Applied Chemistry for Engineering
    • /
    • v.20 no.5
    • /
    • pp.547-552
    • /
    • 2009
  • When fiber reinforced plastics (FRP) products are manufactured, dust and odor materials are inevitably generated in a workplace. To improve the bad condition of the workshop, we developed the Hybrid Bag Filter attached activated carbon fiber (ACF) and installed the system at two companies producing FRP goods. In order to raise the efficiency of dust collection, we set the ducts both on the ceiling and at the bottom of the wall and according to the circumstances of the workshop's space, moving dust collector also adopted as a different type of flexible duct. Pulse Jet Type Bag Filter is also equipped to operate the system more effectively, for the improved fine environment because of high dust removal efficiency. Finally, we investigated the removal tendency of the dust and odor when operating the System of Hybrid Bag Filter.

Material Auto-Transformation Plan using Steal House Method (스틸하우스 공법을 이용한 자재 자동 변환 방안)

  • Han, Jung-Soo;Kim, Gui-Jung
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.5
    • /
    • pp.25-31
    • /
    • 2011
  • In this paper, we propose virtual building construction plans. For this, we compose the construction materials with components and assemble components in pattern. When we change assembled constructions, we can design the building efficiently with patterns if the parts are selected. Also through information analysis of material components or patterns, we can provide information which is necessary to a reconstruction to the designer. Using steal house method, the assembly functions were comprised of a wall, a room, a window, a door, roof etc. Also We explained the materials automatic extraction method which applies steal house.

Prediction of Dynamic Behavior of Ice-Structure Interaction Process (빙-구조물 상호작용의 동적거동해석)

  • Chae-Whan Rim;Jong-Won Lee;Byung-Chun Shin
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.33 no.4
    • /
    • pp.87-96
    • /
    • 1996
  • The dynamic ice forces on a structure with vertical wall and the corresponding responses of the structure are predicted. The structure was simplified as a 1-degree-of freedom system which consists of spring-mass-damper. Ice was divided into two parts : near filed and far field. In the near field, ice sheet moves with constant speed. The results obtained from the numerical simulation using the model and the experiment of indentation with stiff and flexible structures are compared. The comparisons show that the model can predict the behavior of structure and ice load with accuracy.

  • PDF

On the Analytical Model of Automotive Steering Hoses Containing Tuner and Its Practical Application (튜너 내장 자동차 조향호스의 해석 모델과 실용적 응용)

  • Lee, J.C.;Oh, S.H.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.6 no.1
    • /
    • pp.1-9
    • /
    • 2009
  • This study presents an analytical model of an automotive steering hose containing tuner(flexible spiral metal tube) to reduce the ripple pressure induced by steering vane pump. The double-wall side branch composed in a steering hose containing tuner was analogically considered as a filter in a conduit. Specialized test equipment was manufactured for the estimation of speed of sound in a conduit and measurement of amplitude ratio between the propagated ripple pressures of inlet and outlet of the steering hose. Experimental data of entire frequency ranges can be obtained through the test once in short time. The results of three points' measurement method and cross-correlation method to estimate the speeds of sound in a hose, tuner, and side branch respectively reveal that cross-correlation method can be used practically. The results of simulation and experiment were so close, especially in the range of engine idling speed, that the proposed analytical model in this study was validated. Sensitivity analyses and experiments show that longer tuner is preferable, and that the positive-positive composition of the steering hoses containing tuner is superior to others to attenuate ripple pressure.

  • PDF

Heat Transfer Characteristics Around a Surface-Mounted Module Cooled by Piezoelectric Fan (압전세라믹 냉각홴에 의한 강제 공랭 모듈 주위의 열전달특성)

  • Park, Sang-Hee;Park, Gyu-Jin;Choi, Seong-Dae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.7
    • /
    • pp.780-788
    • /
    • 2004
  • This paper reports the fluid flow and heat transfer around a module cooled by forced air flow generated by a piezoelectric(PZT) cooling fan. The fluids are locally accelerated by a flexible PZT fan which deflects inside a fluid transport system of comparatively simple structure mounted on a PCB in a parallel-plate channel(450${\times}$80${\times}$700㎣). Input voltages of 20-100V and a resonance frequency of 23㎐ were used to vibrate the cooling fan. Input power to the module was 4W. The fluid flow around the module was visualized by using PIV system. The temperature distributions around a heated module were visualized by using liquid crystal film(LCF). The cooling effect using a PZT fan was independent of the vent area ratios at the channel inlet and was similar to the forced convection cooling. We found that the flow type was Y-shape and the cooling effect was increased by the wake generated by a piezoelectric cooling fan.

A Study on the Thermal Response Characteristics of Snow Removing Facilities using Heat Pipe (히트파이프식 제설설비의 열응답 특성에 관한 연구)

  • Lee, Yong-Soo;Jang, Yeong-Suk
    • Solar Energy
    • /
    • v.17 no.4
    • /
    • pp.45-56
    • /
    • 1997
  • The purpose of this research was to study the characteristics of heat transfer of snow removing facilities using heat pipe by experimental method. Heat pipes was constructed a flexible tube connected between evaporator and condenser ends for altitude adjustment of evaporator and it was constituted an internal diameter of 25.4mm, a length of 950mm for heating section and a length of 6000mm for condenser section with copper material for closed system. The results showed that the effect of heat transfer was increased when inclination angle and inlet temperature of heating water increased. Wall temperature response by inclined angle $4.5^{\circ}c-9^{\circ}c$ and working fluid amount 0.96 from to 1.3 times of evaporator volume were better than those of other working fluid and angle.

  • PDF