• Title/Summary/Keyword: Flat-Plates

Search Result 268, Processing Time 0.023 seconds

Numerical Analysis on the Effect of Long-crested Wave to the RCS of Marine Target (장파봉파가 해상표적의 RCS에 미치는 영향에 대한 수치해석)

  • Kim, Kook-Hyun;Cho, Dae-Seung;Kim, Jin-Hyeong;Lee, Jeong-Kwan
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.43 no.3 s.147
    • /
    • pp.384-391
    • /
    • 2006
  • RCS effects of long-crested wave surfaces to marine targets are numerically analyzed using a 4-path model and a direct analysis method, developed based on physical optics and a combined method of physical optics/geometric optics, respectively. Reflectivity of long-crested wave surfaces is described with 'Fresnel reflection coefficients' The MPM(modified Pierson-Moskowitz) ocean spectrum is adopted to simulate long-crested waves in the direct analysis method. A numerical analysis of a benchmark model assures the validity of both methods. The direct analysis method is applied to the RCS calculation of electromagnetically large marine targets, which are vertically oriented or slanted to the long crested wave surfaces randomly generated with various significant wave heights. The long-crested wave surface much highly increases the RCS of the marine target, but those effects are decreased as the significant wave height grows up. At low elevation angle, the vertical model has entirely high RCS comparing slanted model, and the RCS of vertical flat plate is the highest on the calm sea surface, while those of slanted flat plates are the lowest on the calm sea surface. The RCS of marine targets on continuously-varying sea surface is more coherent at lower elevation angles, as well.

Probability Based Determination of Slab Thickness Satisfying Floor Vibration Criteria (수직진동 사용성 기준을 고려한 바닥판 두께 제안)

  • Lee Min-Jung;Nam Sang-Wook;Han Sang-Whan
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.5 s.89
    • /
    • pp.687-694
    • /
    • 2005
  • In current design practice, the thickness of the floor slab has been determined to satisfy requirement for deflection control. However, previous study shows that the floor thicknesses in residential buildings may not satisfy the floor vibration criteria, even though the thickness is determined by the serviceability requirements in current design provisons. Thus it is necessary to develop the procedure to determine slab thickness that satisfies the floor vibration criteria. This study attempts to propose slab thickness for flat plate slab systems that satisfies floor vibration criteria against occupant induced floor vibration(heel drop load). Two boundary conditions(simple and fixed support), three square flat plates(4, 6, 8m), and five concrete strength($18\~30$ MPa) are considered. Since there are large uncertainties in loading and material properties, probabilistic approach is adopted using Monte-Carlo simulation procedures.

Natural Convection Heat Transfer Past an Outer Rectangular Corner (외부 직각모서리 부근에서의 자연대류 열전달)

  • 신순철;장근식;김승수
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.9 no.5
    • /
    • pp.598-605
    • /
    • 1985
  • Laminar natural convection heat transfer past an outer rectangular corner was experimentally investigated by using Mach-Zehnder interferometer. The present geometry represents the case when the plume from a vertical flat plate and that from a horizontal one merge into a single plume. the temperature distribution and the local heat flux were measured in the range of Grashof number 8 * 10$^{4}$$r_{LH}$ <1.25 * 10$^{6}$ . The effect of the geometric aspect ratio was also considered. Correlation for the average Nusselt number vs. Grashof number was obtained by using a newly determined characteristic length. To determine the interaction of the plumes, the present results were compared with the similarity solutions available from the isolated vertical and isolated horizontal flat plates.

Damage Assessment of Curved Composite Laminate Structures Subjected to Low-Velocity Impact (곡률을 가진 적층복합재 구조에서의 저속충격손상 평가)

  • 전정규;권오양;이우식
    • Composites Research
    • /
    • v.14 no.2
    • /
    • pp.22-32
    • /
    • 2001
  • Damage induced by low-velocity impact on the curved composite laminates was experimentally evaluated for CFRP cylindrical shells with the radius of curvatures of 50, 150, 300, and 500 mm. The result was then compared with that of flat laminates and with the results by nonlinear finite-element analysis. The radius of curvatures and the effective shell stiffness appeared to considerably affect the dynamic impact response of curved shells. Under the same impact energy level, the maximum contact force increased with the decreasing radius of curvatures, with reaching 1.5 times that for plates at the radius of curvature of 50 mm. Since the maximum contact farce is directly related to the impact damage, curved laminates can be more susceptible to delamination and less resistant to the low-velocity impact damage. Delamination was distributed rather evenly at each interface along the thickness direction of curved laminates on the contrary to the case of flat laminates, where delamination is typically concentrated at the interfaces away from the impact point. This implies that the effect of curvatures has to be considered for the design of a curved composite laminate.

  • PDF

Development of a Garlic Peeling System Using High-Pressure Water Jets (I) - Peeling tests with high-pressure plunger pumps and flat-spray nozzles - (습식 마늘박피 시스템 개발 (I) - 고압 플런저 펌프와 부채꼴 분사노즐을 이용한 박피 실험 -)

  • 양규원;배영환;백성기
    • Journal of Biosystems Engineering
    • /
    • v.29 no.3
    • /
    • pp.217-224
    • /
    • 2004
  • This research was conducted to test the feasibility of utilizing high-pressure water jets of over 1.0㎫ as a means of breaking and peeling garlic bulbs. High-pressure plunger pumps and flat-spray nozzles of varying orifice diameters and spray angles were utilized to supply water jets into a prototype peeling chamber made of transparent acrylic plates. Water jets were discharged from a total of six nozzles installed in such a way that three parallel nozzles face the other three. The cross-sectional area of the peeling chamber and the installation angle of the nozzles had critical effects on peeling performance. Small cross-sectional area was required so that total impact force of water jets on garlic could be increased. The optimum installation angles were around 4, 8, and 16$^{\circ}$ for the nozzles having 15, 40, and 65$^{\circ}$ spray angles, respectively. Best performance with 61.4% of completely-peeled garlics was obtained at a pressure of 1.94㎫ and a flow rate of 9.07 $\ell$/min for each nozzle. The peeling efficiency of the system was generally unsatisfactory due to the limited flow rate of the plunger pumps utilized. For better performance, it is recommended to increase flow rate while reducing operating pressure by utilizing other type of pumps.

Particle removal characteristics of high-velocity electrostatic mist eliminator (정전 고속 미스트 엘리미네이터의 포집 효율 특성)

  • Kim, Jin-seon;Kim, Hak-Joon;Han, Bangwoo;Woo, Chang Gyu;Kim, Yong-Jin;Lee, Sangrin;Moon, Sangchul
    • Particle and aerosol research
    • /
    • v.14 no.4
    • /
    • pp.121-133
    • /
    • 2018
  • In this study, we developed a flat-plate type wet electrostatic precipitator that generates stable corona discharge compared to wire type discharge electrode. In order to compare the particle removal efficiency according to the shape of the discharge electrode such as the variation of the horizontal and vertical distance between spiked edges, and the variation of the height of discharge pin support were tested. As a result, when the horizontal distance between spiked edges was increased up to 36 mm, the vertical distance between spiked edges was increased up to 54 mm, and the height of the discharge pin support was increased up to 76 mm, the removal efficiency of PM10 was maintained at approximate 60.0%. Furthermore, the removal efficiency of particles over $5{\mu}m$ was about 80% or more. When the flow rate was 4 m/s, the gap between collection plates was 60 mm, and -14 kV was applied to the discharge electrode. The particle removal efficiency of the flat-plate type electrostatic precipitator was maintained when the horizontal and vertical distance between spiked edges, and the height of the discharge pin support was below a certain level. Those variables may be the important design factors for the shape of the discharge electrode. Therefore, when designing the electrostatic precipitator with multiple channels, the horizontal and vertical distance between spiked edges, and the height of discharge pin support must be selected in consideration of the weight of the discharge electrode and the processing cost.

Artificial Mass Culture of Flat Oyster Larvae, Ostrea denselamellosa, and Collection Rates according to Various Spat Collection Methods (벗굴, Ostrea denselamellosa, 유생의 인공대량사육과 채묘방법에 따른 채묘율)

  • 양문호;김형섭;이재용;한창희
    • The Korean Journal of Malacology
    • /
    • v.17 no.1
    • /
    • pp.35-44
    • /
    • 2001
  • This research was conducted to develop seedling production techniques in flat oyster, Ostrea dense lamellosa. The cultivation of larvae, artificial spat and spats collection in natural conditions rate were examined. In the mass culture tank (3 tons), average growth rates of the D Shape larvae of initial shell length (153.4 ㎛) and shell height (153.4 ㎛) were 202.6% and 212.9% at 16 days and 227.1%, 241.8% at 20 days, respectively. Instantaneous death and survival rate of the larvae were 0.160 and 54.8% at 16 days and 0.057 and 43.2% at 20 days, respectively. Collection rate of flat oyster from bottom using various collectors with oyster shell, scallop shell, ark shell and PVC plates were 32.9%, 24.1%, 16.8% and 10.0%, respectively. and the greatest collecting rate was 131.9 individuals/shell (32.9%) in laid collectors on the bottom. The collecting rate of the oyster larvae were better in laid collectors on the bottom 83.8 individuals/collection than in the suspended string 54.2 individuals/collection. in all collecting substrates. Early spats settled on collectors were grew to 2.38 $\pm$ 0.97 ㎜ in shell length and 2.16 $\pm$ 0.86 ㎜ In shell height at 26 days. The spats were grew to 28.58 $\pm$ 2.39 ㎜ in shell length and 31.65 $\pm$ 2.03 ㎜ in shell height during the 4 month mid-term cultivation. In the period of cultivation, the mean number of spats attached to collectors were 10.3 individuals at oyster shells, 5.8 scallop shells, 4.0 ark shells and 1.5 PVC plates, respectively.

  • PDF

Development on the lungs of fetuses and neonates in Korean native goats (한국 재래산양의 태아 및 신생아의 폐 발달에 관하여)

  • 서득록;이국천;이순선;김종섭
    • Korean Journal of Veterinary Service
    • /
    • v.20 no.1
    • /
    • pp.55-67
    • /
    • 1997
  • The morphological development of lungs in fetuses of 60, 90 and 120 days of gestation and neonates of Korean native goats was investigated by light, scanning and transmission electron mictroscope. The results were summarized as follows ; 1. Gross findings ; In the 60-days-old fetus, the lung was developed and differentiated into six lobes. 2. Light microscopic findings : The gland-like bronchioles were formed in loose mesenchyme at 60 days of gestation and the bronchial wall contained smooth muscles. The loose mesenchyme had been replaced by compact parenchymal tissue at 90 days of gestation and the cartilage plates appeared in bronchial wall which contained blood vessels, submucosal glands and smooth muscles. The lung parenchyma consisted of a fine network of alveoli at 120 days of gestation and the bronchial wall contained well-developed blood vessels, submucosal glands, cartilage plates and smooth muscles. In neonates, the lung tissue was similar to the mature lung tissue and the bronchial wall contained well developed cartilage plates. 3. Scanning electron microscopic findings : The epithelial cells lining the tubules were composed of cuboidal or columnar at 60 days of gestation and the epithelial cells lining the large airways were often ciliated : some were covered with stubby microvilli. The epithelial cells lining the canals were cuboidal at 90 days of gestation and the epithelial cells lining the bronchioles were ciliated cells or nonciliated(clara) cells, The clara cells contained row microvilli. The alvealor development of this stage was rapidly progressed ; the subdivision of canals by alveolar crests and assosiated wall attenuation resulted alveoli at 120 days of gestation and the respiratory bronchioles were lined by ciliated or nonciliated epithelial cells. In neonates, the epithelial cells lining the alveolar walls were mainly covered with pneumocyte type I ; Some were covered with pneu-mocyte type II. 4. Transmission electron microscopic findings : The epithelial cells lining the tubules were adhered with tight junction at apical borders of the adjacent cells at 60 days of gestation, which contained few organells and glycogen. The epithelial cells lining the canals were composed mostly of cuboidal cell at 90 days of gestation and the epithelial cells lining of the bronchioles were ciliated of nonciliated cell, which contained few organelles and abundant glycogen. The epithelial cells lining the alveolar walls were composed of pneumocyte type I and a few pneumocyte type II at 120 days of gestation. The epithelial cells lining of the bronchioles were ciliated or nonciliated cells. In neonates, pneumocyte type I was observed as flat and thin cytoplasmic extension in shape. Otherwise, pneumocyte type II was observed as cuboidal type with apical microvilli and contained osmiophillic lamellar inclusion bodies. Putting these various experiment results together, the lung development was slowly progressed at early stage, which was rapidly progressed in the late stage of gestation.

  • PDF

Improvement of Flexural Performance for Deep-Deck Plate using Cap Plate (캡플레이트를 이용한 장스팬용 춤이 깊은 데크의 휨성능 개선)

  • Park, K.Y.;Nam, Y.S.;Choi, Y.H.;Kim, Y.H.;Choi, S.M.
    • Journal of Korean Society of Steel Construction
    • /
    • v.25 no.5
    • /
    • pp.555-567
    • /
    • 2013
  • Slim floor system using deep decks has been developed and employed in Europe to reduce the floor height of steel structures. Although long span buildings involving the issue of reducing floor height are being increasingly built in Korea, employing deep decks in more than 7m long span structures is likely to cause problems associated with excessive deflection. This study is applied to the long-span concrete casting of the deep deck plate usability of deflection due to bending and torsional instability of open cross-section, as a way to improve the problem of cap plates are suggested, and the optimum length of reinforcement and location are derived from theoretic estimation. The cap plates are placed on the deep decks with regular intervals to overcome the instability of open sections, improve the stiffness of the sections and control the deflection at the centers. The improvement in flexural capacity associated with the location of the cap plates and the length of reinforcement are verified through analysis and test.

Development of Flat Plate Type Small Cooling Device (Flat Plate Type 소형 냉각소자 개발)

  • Moon, Seok-Hwan;Hwang, Gunn;You, In-Kyu;Cho, Kyoung-Ik;Yu, Byoung-Gon
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.170-174
    • /
    • 2008
  • Recently, a problem related to the thermal management in portable electronic and telecommunication devices is becoming issued. That is due to the trend of slimness of the devices, so it is not easy to find the optimal thermal management technology for the devices. From now on, a pressed circular type cooling device has been mainly used, however the cooling device with thin thickness is becoming needed by the inner space constraint. In the present study, the silicon and metal flat plate type cooling device with the separated vapor and liquid flow path was designed and fabricated. Through the experimental study, the normal isothermal characteristic by vapor-liquid phase change was confirmed and the cooling device with 70mm of total length showed 6.8W of the heat transfer rate within the range of $4{\sim}5^{\circ}C$/W of thermal resistance. In the meantime, the metal cooling device was developed for commercialization. The device was designed to have all structures of evaporator, vapor flow path, liquid flow path and condenser in one plate. And an envelope of that could be completed by combining the two plates of same structure and size. And the simplicity of fabrication process and reduction of manufacturing cost could be accomplished by using the stamping technology for fabricating large flow paths relatively. In the future, it will be possible to develop the commercialized cooling device by revising the fabrication process and enhancing the thermal performance of that.

  • PDF